logo
Anhui Tongdu International Trade Co., Ltd.
온라인 서비스

온라인 서비스

담당자
+86 19056002718
위챗 QR 코드
따라와

내화성 케이블

품질 BTTRZ X50mm2 + 1x25mm2 방화 케이블 광물 비상 전력 구리 껍질 케이블 공장

BTTRZ X50mm2 + 1x25mm2 방화 케이블 광물 비상 전력 구리 껍질 케이블

BTTRZ x50mm²+1x25mm² Mineral Insulated Fire Resistant Copper Sheathed Cable for Emergency Power Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire/power cable) T Copper conductor (Tong = copper) T Copper sheath (Tong = copper) R Flexible (Rou = flexible) Z Heavy ...

품질 BTLY 방화용 케이블 4x35mm2 + 1x16mm2 알루미늄 껍질 케이블 비상용 공장

BTLY 방화용 케이블 4x35mm2 + 1x16mm2 알루미늄 껍질 케이블 비상용

NG-A BTLY 4x35+1x16mm2 Mineral Insulated Fire Resistant Aluminum Sheath Cable for Emergency Cable Designation & Meaning Code Meaning NG-A New Generation A-class fire-resistant (Chinese designation) (BTLY) Building wire, Thin copper conductor, Lightweight Y— alternative naming convention indicating: ...

품질 4x185mm2 + 1x150mm2 방화 케이블 0.6KV 1KV 광물 단열 구리 케이블 공장

4x185mm2 + 1x150mm2 방화 케이블 0.6KV 1KV 광물 단열 구리 케이블

Super Fire Cable BTTRZ 4x185mm²+1x150mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...

품질 BTTRZ 불 retardant 케이블 4x150mm2 + 1x120mm2 미네랄 격리 케이블 공장

BTTRZ 불 retardant 케이블 4x150mm2 + 1x120mm2 미네랄 격리 케이블

Ultra Fire Cable BTTRZ 4x150mm²+1x120mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...

품질 4+1 코어 내화 케이블 120mm2+1x95mm2 BTTRZ 내화 변전소 케이블 공장

4+1 코어 내화 케이블 120mm2+1x95mm2 BTTRZ 내화 변전소 케이블

Fire Substation Cable 4+1 Core 120mm²+1x95mm² BTTRZ Fire Resistant Mineral Insulated Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6...

품질 대형 내화 전선 4x95mm2+1x70mm2 미네랄 절연 난방 케이블 공장

대형 내화 전선 4x95mm2+1x70mm2 미네랄 절연 난방 케이블

Large Fire Cable BTTRZ 4x95mm²+1x70mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV ...

품질 4x70mm2 + 1x50mm2 방화 케이블 1KV 1.2KV 광물 단열 케이블 공장

4x70mm2 + 1x50mm2 방화 케이블 1KV 1.2KV 광물 단열 케이블

Heavy Duty Fire Cable BTTRZ 4x70mm²+1x50mm² Mineral Insulated 0.6/1kV Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV Rated ...

품질 병원용 내화 미네랄 케이블 3200kg/km MI 히팅 케이블 공장

병원용 내화 미네랄 케이블 3200kg/km MI 히팅 케이블

Hospital Critical Cable BTTRZ 4x35mm²+1x16mm² Mineral Insulated Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV ...

품질 25mm2 방화력 케이블 4x25mm2 + 1x16mm2 광물 단열 구리 공장

25mm2 방화력 케이블 4x25mm2 + 1x16mm2 광물 단열 구리

0.6/1kV Mineral Insulated Cable BTTRZ 4x25mm²+1x16mm² Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV Rated ...

이전 1 2 다음