耐火性ケーブル
BTTRZ X50mm2+1x25mm2 耐火ケーブル ミネラル 緊急電源 銅被覆ケーブル
BTTRZ x50mm²+1x25mm² Mineral Insulated Fire Resistant Copper Sheathed Cable for Emergency Power Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire/power cable) T Copper conductor (Tong = copper) T Copper sheath (Tong = copper) R Flexible (Rou = flexible) Z Heavy ...
BTLY 耐火ケーブル 4x35mm2 + 1x16mm2 アルミニウム被覆ケーブル 緊急用
NG-A BTLY 4x35+1x16mm2 Mineral Insulated Fire Resistant Aluminum Sheath Cable for Emergency Cable Designation & Meaning Code Meaning NG-A New Generation A-class fire-resistant (Chinese designation) (BTLY) Building wire, Thin copper conductor, Lightweight Y— alternative naming convention indicating: ...
0.6KV 1KV耐火ケーブル 0.6KV 1KV鉱物絶縁銅ケーブル 4x185mm2+1x195mm2
Super Fire Cable BTTRZ 4x185mm²+1x95mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ Flexible mineral-insulated copper-sheathed fire-resistant cable 4×185 mm² Four cores of 185 mm² copper conductor (3 phase + 1 neutral) +1×95 mm² One core of 95 mm² copper ...
BTTRZ難燃ケーブル 4x150mm2+1x70mm2 ミネラル絶縁ケーブル
Ultra Fire Cable BTTRZ 4x150mm²+1x70mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ Flexible mineral-insulated copper-sheathed fire-resistant cable 4×150 mm² Four cores of 150 mm² copper conductor (3 phase + 1 neutral) +1×70 mm² One core of 70 mm² copper ...
4+1 コア耐火ケーブル 120mm2+1x70mm2 BTTRZ 消防変電所ケーブル
Fire Substation Cable 4+1 Core 120mm²+1x70mm² BTTRZ Fire Resistant Mineral Insulated Cable Designation & Meaning Code Meaning BTTRZ Flexible mineral-insulated copper-sheathed fire-resistant cable 4×120 mm² Four cores of 120 mm² copper conductor (3 phase + 1 neutral) +1×70 mm² One core of 70 mm² ...
大型耐火電線 4x95mm2+1x50mm2 ミネラル絶縁ヒーティングケーブル
Large Fire Cable BTTRZ 4x95mm²+1x50mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ Flexible mineral-insulated copper-sheathed fire-resistant cable 4×95 mm² Four cores of 95 mm² copper conductor (3 phase + 1 neutral) +1×50 mm² One core of 50 mm² copper ...
4x70mm2+1x35mm2 1KV 1.2KV 耐火ケーブル 裸銅鉱物絶縁ケーブル
Heavy Duty Fire Cable BTTRZ 4x70mm²+1x35mm² Mineral Insulated 0.6/1kV Cable Designation & Meaning Code Meaning BTTRZ Flexible mineral-insulated copper-sheathed fire-resistant cable 4×70 mm² Four cores of 70 mm² copper conductor (3 phase + 1 neutral) +1×35 mm² One core of 35 mm² copper conductor ...
病院用防火ケーブル BTTRZ 4x35mm²+1x16mm² ミネラル加熱ケーブル
Hospital Critical Fire Proof Cable BTTRZ 4x35mm²+1x16mm² Mineral Mi Heating Cable Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...
25mm2耐火ケーブル 4x25mm2+1x16mm2 ミネラル絶縁銅
0.6/1kV Mineral Insulated Cable BTTRZ 4x25mm²+1x16mm² Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV Rated ...