Cable resistente al fuego
Cable ignífugo BTTRZ de 50 mm2 + 1x25 mm2 para emergencia de energía con revestimiento de cobre
BTTRZ x50mm²+1x25mm² Mineral Insulated Fire Resistant Copper Sheathed Cable for Emergency Power Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire/power cable) T Copper conductor (Tong = copper) T Copper sheath (Tong = copper) R Flexible (Rou = flexible) Z Heavy ...
BTLY Cable calificado para incendios 4x35mm2 + 1x16mm2 Cable de cubierta de aluminio para emergencias
NG-A BTLY 4x35+1x16mm2 Mineral Insulated Fire Resistant Aluminum Sheath Cable for Emergency Cable Designation & Meaning Code Meaning NG-A New Generation A-class fire-resistant (Chinese designation) (BTLY) Building wire, Thin copper conductor, Lightweight Y— alternative naming convention indicating: ...
Cable ignífugo 4x185mm2+1x150mm2 0.6KV 1KV de cobre con aislamiento mineral
Super Fire Cable BTTRZ 4x185mm²+1x150mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...
Cable Mineral Aislado BTTRZ Ignífugo 4x150mm2+1x120mm2
Ultra Fire Cable BTTRZ 4x150mm²+1x120mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...
4+1 Cable de base resistente al fuego 120mm2+1x95mm2 BTTRZ Cable de subestación de incendios
Fire Substation Cable 4+1 Core 120mm²+1x95mm² BTTRZ Fire Resistant Mineral Insulated Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6...
Cables de calefacción aislados por minerales de 4x95 mm2 + 1x70 mm2
Large Fire Cable BTTRZ 4x95mm²+1x70mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV ...
4x70mm2 + 1x50mm2 Cable resistente al fuego 1KV 1.2KV Cable aislado de cobre mineral desnudo
Heavy Duty Fire Cable BTTRZ 4x70mm²+1x50mm² Mineral Insulated 0.6/1kV Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV Rated ...
Cable de calefacción Mi mineral ignífugo crítico para hospitales de 3200 kg/km
Hospital Critical Cable BTTRZ 4x35mm²+1x16mm² Mineral Insulated Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV ...
Cable ignífugo de 25 mm2 4x25 mm2 + 1x16 mm2 de cobre con aislamiento mineral
0.6/1kV Mineral Insulated Cable BTTRZ 4x25mm²+1x16mm² Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV Rated ...