4x70mm2+1x35mm2 Fire Resistant Cable 1KV 1.2KV Bare Copper Mineral Insulated Cable
Product Summary
Product Details
4x70mm2+1x50mm2 fire resistant cable
,fire resistant cable 1kv
,1.2kv bare copper mineral insulated cable
Product Description
Heavy Duty Fire Cable BTTRZ 4x70mm²+1x35mm² Mineral Insulated 0.6/1kV
Cable Designation & Meaning
|
Code |
Meaning |
|---|---|
|
BTTRZ |
Flexible mineral-insulated copper-sheathed fire-resistant cable |
|
4×70 mm² |
Four cores of 70 mm² copper conductor (3 phase + 1 neutral) |
|
+1×35 mm² |
One core of 35 mm² copper conductor (earth/protective conductor) |
Construction: Multiple flexible copper strands per core, wrapped with mineral insulation (MgO compound), enclosed in a continuous copper sheath, with colour-coded cores (typically by insulation tape or outer marking).
Note: BTTRZ employs Class 5 fine-stranded flexible copper conductors. Each core is insulated with fire-resistant mica tape plus XLPE (or ceramic silicone rubber). Cores are assembled with mineral fillers and enclosed in a continuously welded corrugated copper tube sheath, which serves simultaneously as armour, water barrier, and PE conductor. The 4+1 configuration is designed for TN-S three-phase five-wire systems; the PE conductor is 50 mm². Per GB/T 16895 / IEC 60364, for phase conductor S > 35 mm², PE ≥ S/2. Since phase = 70 mm², S/2 = 35 mm², thus PE = 50 mm² exceeds the minimum requirement and is fully compliant (many projects specify PE = phase for added safety margin).


BTTRZ 4×185 mm²+1×95 mm² — Flexible Mineral Fire-Resistant Cable — Specification
1. Overview & Ratings. BTTRZ 4×185+1×95 is a large-section flexible mineral-insulated fire-resistant cable rated 0.6/1 kV, 90 °C working, maintaining live circuit at 950 °C for 180 min. Four 185 mm² power cores plus a central 95 mm² PE, mica-wrapped, thick sealed copper tube, teal low-smoke outer. OD ≈ 53.5 mm, ≈ 8600 kg/km, ≈ 430 A — the largest in this family, for main fire loops.
2. Construction Stack (Inner → Outer).
| Layer | Build | Function |
|---|---|---|
| Power cores | 4×185 compacted Cu, Class 2, mica wrap | L1/L2/L3/N, fire barrier |
| Earth core | 1×95 compacted Cu, mica wrap (center) | PE continuity |
| Copper sheath | Thick sealed copper tube | Moisture / EMI shield |
| Fire-resistant outer | Zero-halogen, deep teal | Low-smoke protection |
3. Electrical Characteristics. 185 core R ≤ 0.0991 Ω/km; 95 core R ≤ 0.206 Ω/km @20 °C. Test 3.5 kV AC / 5 min; nominal ≈ 430 A (air, 30 °C); short-circuit ≈ 16.4 kA / 1 s.
Insulation Data
|
Property |
Value |
|---|---|
|
Insulation material |
Mineral compound (MgO-based), non-combustible |
|
Outer sheath material |
Copper tube/tape (continuous), optional PVC/LSZH outer coating |
|
Long-term service temp. |
90 °C (continuous, mineral insulation) |
|
Max. conductor temp. (normal) |
90 °C |
|
Short-circuit temp. (≤5 s) |
1083 °C (Cu melting point) |
|
Emergency overload temp. |
130 °C (short term, ≤1 h) |
|
Test voltage AC (5 min) |
3.5 kV (routine test, 0.6/1 kV class) |
|
Dielectric strength |
≥ 20 kV/mm (room temp., mineral insulation) |
|
Volume resistivity @20 °C |
≥ 1×10¹⁴ Ω·cm |
|
Shield |
Copper sheath provides natural electromagnetic shielding |
Electrical Parameters
|
Parameter |
Value |
Note |
|---|---|---|
|
Rated voltage U₀/U |
0.6 / 1 kV |
GB/T 13033.1 / IEC 60702-1 |
|
Max. system voltage |
1.2 kV AC |
— |
|
Test voltage AC (5 min) |
3.5 kV |
Routine test (conductor-to-sheath) |
|
DC resistance @20 °C (70 mm²) |
≤ 0.268 Ω/km |
GB/T 3956 Class 5 Cu max |
|
DC resistance @20 °C (35 mm²) |
≤ 0.524 Ω/km |
GB/T 3956 Class 5 Cu max |
|
AC resistance @90 °C (est., 70 mm²) |
≈ 0.344 Ω/km |
— |
|
AC resistance @90 °C (est., 35 mm²) |
≈ 0.672 Ω/km |
— |
|
Current rating in air (30 °C) |
Phase: 230 A |
4-core + 1 earth, touching, in free air |
|
Current rating in tray (30 °C) |
Phase: 215 A |
spaced 2×OD |
|
Current rating buried in ground (20 °C, thermal resistivity 1.2 K·m/W) |
Phase: 200 A |
direct buried |
|
Current rating in conduit (30 °C) |
Phase: 190 A |
— |
|
Short-circuit current (1 s, Cu, 1083 °C, 70 mm²) |
≈ 7.7 kA (7,700 A) |
limited by copper sheath |
|
Short-circuit current (1 s, Cu, 1083 °C, 35 mm²) |
≈ 3.9 kA (3,900 A) |
limited by copper sheath |
|
Capacitance (core-to-sheath, approx.) |
≈ 0.18 µF/km (70 mm²), ≈ 0.14 µF/km (35 mm²) |
mineral insulation |
|
Inductive reactance (approx.) |
≈ 0.10 Ω/km |
at 50 Hz |
|
Frequency |
50/60 Hz AC |
— |
Reference values: 4×70+1×35 at 230 A, three-phase 400 V → max load ≈ 138 kW (cos φ = 0.8). Suitable for small-to-medium fire pumps, emergency lighting, smoke extraction, and critical life-safety systems.
Temperature Characteristics
|
Property |
Value |
|---|---|
|
Max. conductor operating temp. |
90 °C (continuous) |
|
Max. short-circuit temp. (≤5 s) |
1083 °C (copper sheath melting point) |
|
Emergency overload temp. |
130 °C (≤1 h, not recommended for continuous) |
|
Min. installation ambient temp. |
−15 °C (flexible mineral cable) |
|
Service ambient range |
−20 °C to +90 °C (mineral insulation, copper sheath) |
|
Flexing temp. range |
−15 °C to +90 °C |
|
Fire survival |
950 °C, 180 min circuit integrity (BS 6387 Category CWZ) |
4. Thermal Response & Flame Behaviour. Mica insulation sustains a 90 °C continuous conductor temperature, with short-circuit capability up to 250 °C for ≤ 5 s. The cable is rated for service ambients between −15 and +70 °C. The defining property is fire resistance: under GB/T 19216.21 / IEC 60331-21, the cable maintains circuit integrity at rated voltage for at least 90 minutes when directly exposed to a 950 °C open flame. The corrugated copper sheath provides both a fire barrier and a mechanical shield against flame penetration. The LSZH outer jacket emits low smoke and no acid gas (halogen-free), meeting the requirements for tunnels, metro systems, hospitals and high-rise public buildings.
Fire Performance (BTTRZ — Mineral Insulated)
|
Property |
Value / Requirement |
|---|---|
|
Fire resistance (circuit integrity) |
BS 6387 Category CWZ: 950 °C, 180 min, water spray, mechanical shock — circuit remains intact |
|
Flame retardant |
IEC 60332-1-2 (single cable, self-extinguishing) |
|
Halogen content |
Zero halogen (mineral insulation + copper sheath) |
|
Smoke density |
Low smoke (IEC 61034, light transmittance ≥ 80%) |
|
Corrosivity |
Non-corrosive (mineral + copper) |
|
Toxicity |
Non-toxic (no PVC, no halogens) |
|
EMI shielding |
Excellent (continuous copper sheath) |
5. Installation Practice & Handling. Bends must not fall below 15 times the actual outer diameter — about 585 mm for this size. The corrugated copper sheath must be earthed at both ends to provide protective-earth continuity. Special sealing glands and termination kits are required at both ends to keep moisture out of the hygroscopic mica layer — improperly terminated ends are the most common failure point on mineral-insulated cables. Reels held below 0 °C in storage must be warmed indoors before uncoiling. The 220 A reference requires derating whenever ambient temperature, grouping or burial depth deviates from reference conditions. At about 250 kg per 100 m, the cable requires drum jacks, rated pulling gear and at least four fitters.
Mechanical & Installation Parameters
|
Parameter |
Value |
Remarks |
|---|---|---|
|
Minimum bending radius |
≥ 6 × OD → ≈ 207 mm at Ø34.5 mm |
flexible mineral cable |
|
Max. pulling tension (70 mm²) |
1,050 N (70 mm² × 15 N/mm²) |
Cu conductor limit |
|
Max. pulling tension (35 mm²) |
525 N (35 mm² × 15 N/mm²) |
Cu conductor limit |
|
Direct burial |
Suitable (copper sheath corrosion-resistant with outer coating) |
— |
|
Surface mounting |
Excellent (cable tray, ladder, cleats) |
— |
|
Conduit ID |
≥ 50 mm |
— |
|
Fixing |
heavy-duty cleats, cable clamps |
— |
|
Impact resistance |
High (copper sheath) |
— |
|
Water resistance |
Excellent (continuous copper sheath, waterproof) |
— |
|
UV resistance |
Excellent (copper sheath does not degrade) |
outdoor use OK |
|
Flex life |
Good (Class 5 flexible, suitable for limited flexing) |
fixed installation preferred |
|
Termination note |
Special mineral cable lugs and seals required; compression terminal with sealing cap |
— |
6. Typical Service Applications. This 4×70+1×50 BTTRZ cable is the fire-rated main feeder for large emergency and safety-critical circuits: main fire-pump and sprinkler-pump feeds up to about 55 kW, main smoke-exhaust and pressurisation fan feeds up to about 18 kW, emergency main switchboard risers, fire-alarm system main power loops, emergency elevator main power supply, hospital emergency main switchboard feeders, metro and tunnel emergency power main distribution, high-rise building fire-fighting main risers, data-centre UPS main emergency feeders, oil and gas platform fire-resistant power cables, stadium and large-venue emergency main distribution, industrial furnace and oven emergency main power, and any circuit where continued operation during a 90-minute fire event is mandated by building code. Approved installation methods include heavy-duty cable tray, direct tray in fire-protected zones, and fire-rated conduit.

7. Testing & Quality Assurance Regime. Routine tests on every length include conductor DC resistance verification (70 mm² ≤ 0.268; 50 mm² ≤ 0.387 Ω/km) at 20 °C, the 3.5 kV AC / 5 min withstand, insulation resistance ≥ 36.7 MΩ·km, conductor continuity across all five cores, corrugated copper sheath electrical continuity, and dimensional inspection covering mica ≈ 0.7 mm, Cu sheath ≈ 0.4 mm, LSZH jacket ≥ 2.0 mm and overall diameter ≈ 39 mm. Sample and type tests comprise the 950 °C / 90 min fire-resistance test (GB/T 19216.21), vertical flame spread GB/T 18380.34 class A, smoke density GB/T 17651, halogen acid gas content GB/T 17650, sheath moisture-tightness / water-immersion leak test, bending at ≥ 15 × OD, short-circuit to 250 °C, and voltage re-test after fire exposure. A factory test certificate accompanies each drum.
Cable Parameters
| BTTRZ 4×70 mm²+1×35 mm² — Flexible Mineral Fire-Resistant Cable — Full Parameter Sheet | |||
| Cu conductor / mica insulation / sealed copper sheath / fire-resistant sheath · 950°C integrity · 0.6/1 kV · ≈ 36.5 mm · rolling shutters & small exhaust branches | |||
| Parameter | Value | Unit | Remarks / Standard |
| 01 · Identification | |||
| Cable type | BTTRZ — flexible mineral fire-resistant cable | — | Fire rated |
| Rated voltage (U0/U) | 0.6/1 | kV | Safety power |
| Core configuration | 4×70 + 1×35 | — | 3P+N+PE |
| Conductor material | Compacted stranded annealed copper | — | Class 2 |
| Insulation | Mica tape wrap (mineral) | — | Fire barrier |
| Sheath | Sealed copper sheath + fire-resistant outer | — | Deep burgundy |
| Fire resistance | 950 °C / 180 min | — | Circuit integrity |
| Application | Fire shutters, small exhaust branches, zone alarm power | — | Life safety |
| 02 · Conductors | |||
| Power cores | 4 × 70 | mm² | L1/L2/L3/N |
| Earth core | 1 × 35 | mm² | PE |
| Conductor type | Compacted stranded Cu, Class 2 | — | Flexible |
| DC resistance (70) @ 20°C | ≤ 0.268 | Ω/km | Cu 70 |
| DC resistance (35) @ 20°C | ≤ 0.524 | Ω/km | Cu 35 |
| 03 · Insulation & Fire Barrier | |||
| Insulation | Mica tape wrap on each core | — | Mineral barrier |
| Fire integrity | 950 °C / 180 min | — | Live under fire |
| Working conductor temp. | 90 | °C | Normal operation |
| Smoke / halogen | Low smoke, zero halogen | — | Evacuation safe |
| 04 · Sheath | |||
| Copper sheath | Sealed copper tube | — | Moisture proof |
| Outer sheath | Fire-retardant, deep burgundy | — | Low smoke |
| Finished outer diameter | ≈ 36.5 | mm | Overall |
| 05 · Electrical | |||
| Rated voltage (U0/U) | 0.6/1 | kV | LV |
| Max voltage (Um) | 1.2 | kV | Phase-to-earth |
| Nominal current (70 core) | ≈ 215 | A | Air, 30°C |
| Test voltage (AC) | 3.5 kV / 5 min | — | Routine |
| Insulation resistance | High, fire stable | MΩ·km | Mineral |
| Short-circuit current (70, 1s) | ≈ 6.2 | kA | Copper |
| 06 · Thermal & Fire | |||
| Normal conductor temp. | 90 | °C | Continuous |
| Fire exposure | 950 °C | °C | 180 min integrity |
| Acid gas | Low acid, halogen free | — | Life safety |
| Ambient range | -40 ~ +90 | °C | Wide |
| 07 · Mechanical & Construction | |||
| Min bending radius (fixed) | ≥ 15 × OD ≈ 548 | mm | Multi-core |
| Flexibility | Flexible mineral, compact section | — | Handy |
| Shielding | Copper sheath = continuous shield | — | EMI + moisture |
| Cable weight per km | ≈ 3600 | kg/km | Cu sheath |
| 08 · Factory Advantages | |||
| Handy section | Compact OD eases tight risers and shutter boxes | — | Easy route |
| Consistent mica pitch | Tape head held at one lay angle across small cores | — | Uniform barrier |
| Clean copper seal | Light wall tube, uniform weld | — | Moisture proof |
| Quick reeling | Lighter mass speeds loading and short pulls | — | Fast job |
| Color-zone cores | Printed L1/L2/L3/N/PE for panel-side identification | — | Less wiring error |
| Bulk cut lengths | Supplied to requested segment, ends sealed | — | No waste |
| Compact QA pack | Resistance, continuity and fire sheet in one bundle | — | Fast handover |
| 09 · Installation | |||
| Laying | Shutter duct, riser, small exhaust branch | — | Safety circuits |
| Connectors | Fire-rated Cu glands, sealed end caps | — | Integrity kept |
| Bend radius | ≥ 15×OD ≈ 548 mm | — | Multi-core |
| Site test | Continuity + insulation post-laying | — | Commissioning |
| 10 · Packing & Applications | |||
| Supply length | Custom / wooden drum | m | Handy |
| Reel type | Standard wooden drum | — | Lighter mass |
| Surface marking | BTTRZ, 4×70+1×35, 0.6/1kV, fire-rated | — | Marking |
| Typical use | Fire shutters, exhaust branches, zone alarm power | — | Life safety |
Cable Test Parameters
| Test Parameters — BTTRZ 4×70+1×35 Fire-Resistant Cable | ||||
| No. | Test Item | Test Condition / Method | Requirement | Type |
| 1 | Conductor DC resistance | 20 °C, each core | 70 ≤0.268 / 35 ≤0.524 Ω/km | Routine |
| 2 | Voltage test (AC) | 3.5 kV AC, 5 min | No breakdown | Routine |
| 3 | Fire integrity | 950 °C / 180 min | Circuit maintained | Type |
| 4 | Continuity | Each core | Continuous | Routine |
| 5 | Insulation resistance | Mineral insulation | High & stable | Routine |
| 6 | Sheath seal | Visual / moisture | No leak | Routine |
| 7 | Mica wrap coverage | Cross-section | Full overlap | Routine |
| 8 | Smoke / halogen | Material check | Zero halogen | Type |
| 9 | Bending test | 15× OD, cycles | No crack | Type |
| 10 | Dimensional check | Caliper | OD ≈ 36.5 mm | Routine |
| 11 | Short-circuit rating | Calculated / type | 6.2 kA / 1 s | Type |
| 12 | Printing legibility | Visual | Marking readable | Routine |
Cable Cross Section Structure

| BTTRZ 4×70+1×35 — Cross-Section Construction Diagram (Schematic) | |||||
| Cu cores / mica wrap / sealed copper sheath / fire-resistant outer · 950°C/180min · 0.6/1 kV · ≈ 36.5 mm | |||||
| No. | Layer | Material / Construction | Nominal Thickness (mm) | Diameter (mm) | Function / Remarks |
| 1 | Power cores | 4×70 compacted Cu, Class 2, mica wrap | — | ≈ 19 each | 950°C fire barrier |
| 2 | Earth core | 1×35 compacted Cu, mica wrap (center) | — | ≈ 13 | PE continuity |
| 3 | Copper sheath | Sealed copper tube | ≈ 0.6 | ≈ 35.3 | Moisture/shield |
| 4 | Fire-resistant outer | Fire-retardant, deep burgundy | ≈ 1.2 | ≈ 36.5 | Low smoke |
| Key Dimensions & Properties (expanded) | |||||
| Finished cable diameter | ≈ 36.5 | mm | Overall | ||
| Approx. cable mass | ≈ 3600 | kg/km | Handy Cu sheath | ||
| Nominal voltage rating | 0.6/1 | kV | LV safety | ||
| Normal conductor temp. | 90 | °C | Continuous | ||
| Fire exposure | 950 °C / 180 min | — | Circuit integrity | ||
| Min bending radius (fixed) | ≥ 15 × OD ≈ 548 | mm | Multi-core | ||
| DC resistance (70) | ≤ 0.268 | Ω/km | Cu 70 | ||
| DC resistance (35) | ≤ 0.524 | Ω/km | Cu 35 | ||
| Nominal current (70 core) | ≈ 215 | A | Air, 30°C | ||
| Smoke / halogen | Low smoke, zero halogen | — | Evacuation | ||
| Short-circuit rating (1s) | ≈ 6.2 | kA | 70 Cu | ||
| Core configuration | 4×70 + 1×35 | — | 3P+N+PE | ||
| Application | Shutters, exhaust, alarm power | — | Safety | ||
| Schematic — not to exact scale. OD ≈36.5 mm and weight ≈3600 kg/km from cross-referenced industry samples. BTTRZ 4×70+1×35 serves fire shutters, small exhaust branches and zone alarm power with 950°C/180min integrity. Values marked (est.) require confirmation against the factory fire-test certificate. | |||||
Cable Construction Description
| Construction Description — BTTRZ 4×70+1×35 flexible mineral fire-resistant cable | |||
| Cu cores / mica wrap / sealed copper sheath / fire-resistant outer · 950°C/180min · 0.6/1 kV · 90°C · ≈36.5 mm | |||
| 1. Product Identity & Ratings | |||
| BTTRZ 4×70+1×35 rated 0.6/1 kV, 90°C working, 950°C/180min integrity. OD ≈36.5 mm, ≈3600 kg/km, ≈215 A, standard wooden drum. | |||
| 2. Copper Conductors (4×70 + 1×35) | |||
| Four 70 mm² power cores (L1/L2/L3/N) + central 35 mm² PE, compacted Class 2 Cu. 70 R ≤0.268, 35 R ≤0.524 Ω/km @20°C. | |||
| 3. Mica Wrap Fire Barrier | |||
| Mica tape at consistent pitch around each compact core keeps the circuit live at 950°C for 180 min. | |||
| 4. Copper Sheath & Outer | |||
| Sealed copper tube (moisture/EMI shield) + deep burgundy low-smoke fire-resistant outer. | |||
| 5. Factory Advantages | |||
| • Compact OD for tight routes. • Consistent mica pitch. • Clean light-wall copper seal. • Quick reeling at 3600 kg/km. • Color-zone printed cores. • Bulk cut lengths, sealed ends. • Compact QA pack in one bundle. | |||
| 6. Site Handling Notes | |||
| • Bend 15×OD (≈548 mm). • Fire-rated sealed glands. • Light reel, easy short pull. • Continuity + insulation after laying. |
8. Factory Advantages.
- Handy section — compact OD eases tight risers and shutter boxes for an easy route.
- Consistent mica pitch — tape head held at one lay angle across the small cores for a uniform barrier.
- Clean copper seal — light-wall tube with a uniform weld keeps moisture out.
- Quick reeling — lighter 3600 kg/km mass speeds loading and short pulls.
- Color-zone cores — printed L1/L2/L3/N/PE for panel-side identification, fewer wiring errors.
- Bulk cut lengths — supplied to the requested segment with sealed ends, no waste.
- Compact QA pack — resistance, continuity and fire sheet bundled in one for fast handover.

9. Packaging, Storage & Logistics. Standard delivery is 500 m or 1000 m per wooden-steel drum, with bespoke cut lengths available on request. Each drum carries type, voltage, size, supplier identity, production year and sequential metre marking per GB/T 6995. Storage should be in dry, covered premises at −15 to +40 °C, shielded from direct sunlight, moisture, oils and sharp objects; drum end seals must remain intact until installation. Because mica is hygroscopic, any drum whose end seal has been damaged must be re-tested for insulation resistance before use. During transit, drums must be secured against rolling and impact.

10. Procurement Specification. State "BTTRZ 0.6/1 kV 4×70+1×50" together with the required length or drum arrangement, and specify whether the corrugated copper sheath is to be used as the protective earth (PE) or whether a separate green-yellow 50 mm² conductor is required. Always order the matching sealing gland and termination kit at both ends. Always request the factory test certificate, which must include the 950 °C / 90 min fire-resistance report, to confirm the actual diameter (≈ 39 mm), weight (≈ 2500 kg/km) and conductor resistances for the production batch.
11. Cable Industry FAQ.
- Q1: When should I choose 70 mm² over 35 mm² for fire-rated circuits? Choose 70 mm² when the emergency load carries up to about 220 A (vs about 140 A for 35 mm²), such as main fire pumps up to 55 kW, large smoke-exhaust fans up to 18 kW, or main emergency switchboard risers where voltage drop is critical. 35 mm² is sufficient for branch-level fire-rated feeders.
- Q2: Why is the neutral/earth core only 50 mm² while phases are 70 mm²? In typical three-phase balanced loads the neutral carries little current, so it is derated to 50 mm². The corrugated copper sheath additionally provides a continuous protective-earth path, so the separate 50 mm² core serves primarily as a system neutral.
- Q3: What does "950 °C / 90 min" actually guarantee? During the GB/T 19216.21 / IEC 60331-21 test, the cable is laid in a test furnace, energised at rated voltage, and directly exposed to a 950 °C flame for 90 minutes. The cable must continue to carry the load without electrical breakdown. This is the rating that justifies its use on fire pumps, emergency lighting and escape-route circuits.
- Q4: Why is the corrugated copper sheath necessary? The copper sheath serves three purposes: (i) physical flame barrier protecting the mica layer; (ii) moisture barrier — mica is hygroscopic and must stay dry; (iii) continuous electrical path that can double as the protective earth (PE).
- Q5: Why is the jacket LSZH instead of PVC? In a fire, PVC releases dense smoke and hydrochloric acid gas, which are the dominant causes of death in fires. LSZH jacket releases low smoke and no acid gas — essential in tunnels, metros, hospitals and high-rise public buildings where evacuation is slow.
- Q6: Why must the termination kit be special? Mica tape is hygroscopic: if moisture enters the cable end, the insulation resistance collapses. Standard PVC cable glands are not air- and moisture-tight. The BTTRZ termination kit uses a sealed brass gland with epoxy sealing compound and a heat-shrink boot.
- Q7: Can the copper sheath replace the separate earth conductor? Yes — the corrugated copper sheath is electrically continuous and can be sized as the protective earth (PE), provided its cross-sectional area and fault-current capacity meet the installation code.
- Q8: How heavy is this cable compared to ordinary PVC? At ≈ 2500 kg/km it is roughly twice the mass of an ordinary RVV 4×70 flexible cord, because of the corrugated copper sheath and mica layers. This is normal for fire-rated cables and must be planned for in tray loading and pulling.
- Q9: Can BTTRZ be used outdoors or buried directly? Yes — the LSZH jacket is UV-resistant and the copper sheath is an effective moisture barrier, so BTTRZ can be installed outdoors, in trays or directly in buried trenches.
- Q10: Which tests confirm acceptability on delivery and before energisation? At delivery, verify the factory fire-resistance certificate (950 °C / 90 min), conductor resistance (70 ≤ 0.268; 50 ≤ 0.387 Ω/km), dimensions (≈ 39 mm), and the drum end-seal integrity. After installation, complete an insulation-resistance test, a 3.5 kV AC / 5 min withstand, and verify both ends of the corrugated copper sheath are properly earthed before energising.
- Q11: What service life can be expected? When installed, terminated and operated within the stated temperature, voltage and fire ratings, BTTRZ cable is designed for a service life of around 30–40 years in fixed installation. The two failure modes to watch are moisture ingress through improperly sealed terminations and mechanical damage to the corrugated sheath.