Cáp chống cháy
BTTRZ X50mm2 + 1x25mm2 Cáp chống cháy Cáp điện khẩn cấp khoáng sản đồng
BTTRZ x50mm²+1x25mm² Mineral Insulated Fire Resistant Copper Sheathed Cable for Emergency Power Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire/power cable) T Copper conductor (Tong = copper) T Copper sheath (Tong = copper) R Flexible (Rou = flexible) Z Heavy ...
BTLY Cáp Chống Cháy 4x35mm2 + 1x16mm2 Vỏ Nhôm Dùng Cho Tình Huống Khẩn Cấp
NG-A BTLY 4x35+1x16mm2 Mineral Insulated Fire Resistant Aluminum Sheath Cable for Emergency Cable Designation & Meaning Code Meaning NG-A New Generation A-class fire-resistant (Chinese designation) (BTLY) Building wire, Thin copper conductor, Lightweight Y— alternative naming convention indicating: ...
Cáp chống cháy 4x185mm2+1x150mm2 0.6KV 1KV Cáp đồng cách điện khoáng
Super Fire Cable BTTRZ 4x185mm²+1x150mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...
Cáp chống cháy BTTRZ 4x150mm2+1x120mm2 Cáp cách điện khoáng
Ultra Fire Cable BTTRZ 4x150mm²+1x120mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...
4 + 1 Cáp chống cháy lõi 120mm2 + 1x95mm2 BTTRZ Cáp trạm phụ lửa
Fire Substation Cable 4+1 Core 120mm²+1x95mm² BTTRZ Fire Resistant Mineral Insulated Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6...
Cáp sưởi nhiệt cách nhiệt khoáng sản lớn 4x95mm2 + 1x70mm2
Large Fire Cable BTTRZ 4x95mm²+1x70mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV ...
Cáp chống cháy 4x70mm2+1x50mm2 1KV 1.2KV Cáp cách điện khoáng đồng trần
Heavy Duty Fire Cable BTTRZ 4x70mm²+1x50mm² Mineral Insulated 0.6/1kV Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV Rated ...
Cáp chống cháy bệnh viện quan trọng khoáng sản 3200kg/Km Mi Cáp sưởi ấm
Hospital Critical Cable BTTRZ 4x35mm²+1x16mm² Mineral Insulated Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV ...
25 mm2 Cáp chống cháy 4x25mm2 + 1x16mm2 đồng cách nhiệt khoáng sản
0.6/1kV Mineral Insulated Cable BTTRZ 4x25mm²+1x16mm² Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV Rated ...