"flat sheathed wires flat electrical sheathed wires"
Please try a different search term or browse our product categories.
Conductor de cobre sólido de 2,5 mm2, tierra, sólido, ignífugo THHN
Yellow Green BV 2.5mm² Ground Earth Wire PVC Insulated Copper Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain copper conductor (solid or stranded)...
Conductor de cobre sólido rojo PVC aislado de cobre de núcleo único
Red BV 2.5mm² PVC Insulated Single Core Copper Live Wire 450/750V Electrical Building Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain copper ...
Cable eléctrico unipolar de cobre blanco con aislamiento de PVC para edificios
BV 2.5mm2 White PVC Insulated Single Core Copper Building Wire 450/750V Household Electrical Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain ...
Cable solar DC (PV) H1Z2Z2-K 4.0 mm2 de núcleo único de cobre enlatado XLPE/XLPO aislado
DC (PV) Solar Cable H1Z2Z2-K 4.0 mm² Single Core Tinned Copper XLPE/XLPO Insulated H1Z2Z2-K 1×4.0 mm² Photovoltaic (PV) DC Solar Cable. H = Harmonised EU designation · 1Z2Z2 = halogen-free (HFFR) insulation + halogen-free (HFFR) sheath, both cross-linked · K = flexible Class 5 conductor · 1×4...
Cable de potencia MV Giant YJV22 3x400mm² 8.7/15kV blindado XLPE
Giant MV Cable YJV22 3x400mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV; Uₘ = ...
Cable de Potencia Blindado XLPE MV Super Pesado YJV22 3x300mm² 8.7/15kV
Super Heavy MV Cable YJV22 3x300mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...
Cable de potencia MV blindado de 3 núcleos YJV22 3x50mm² 8.7/10kV 8.7/15kV XLPE
3 Core Armored MV Cable YJV22 3x50mm² 8.7/10kV 8.7/15kV XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...
Cable Mineral Aislado BTTRZ Ignífugo 4x150mm2+1x120mm2
Ultra Fire Cable BTTRZ 4x150mm²+1x120mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...