"flat sheathed wires flat electrical sheathed wires"
Please try a different search term or browse our product categories.
4.0mm2 単線銅導体 450V 750V 単線銅線
BV 4.0mm² Solid Copper PVC Insulated Building Wire 450/750V Easy Pull Electrical Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 4.0 mm² Nominal cross-sectional area of conductor Construction: Plain copper conductor ...
黒 BV 2.5mm2 固体銅コア 管の設置用 PVCワイヤ
Black BV 2.5mm² Solid Copper Conductor PVC Wire for Conduit Installation Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain copper conductor (solid or ...
1.0mm2 軟銅導体 焼きなまし 18 AWG 無被覆銅線
BV 1.0 mm² / 18 AWG — Technical Specification Category Parameter Value / Description Product Identity Model Number BV (equivalent to 60227 IEC 01 / IEC 05) Product Name Copper Conductor PVC Insulated Single-Core Building Wire Standards Compliance GB/T 5023.3-2008, JB/T 8734.2-2016 Certification CCC ...
H1Z2Z2-K 4.0mm2 ソーラーケーブル TUV 1500V XLPE銅ケーブル
H1Z2Z2-K 4.0mm² TUV 1500V DC Solar Cable UV Resistant Halogen Free XLPE Copper Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) Z ...
単芯太陽光発電ケーブル 6.0mm2 TUV XLPE Cuケーブル
1500V DC Solar Wire PV1-F 6.0mm² TUV XLPE Copper Photovoltaic Cable Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction: Tinned copper conductor, halogen...
3x400mm2 中圧電力ケーブル アルミニウム XLPE 鎧付き MVケーブル 8.7kV
YJLV22 3x400mm² Aluminum XLPE Armored MV Cable 8.7/15kV Cost Effective Underground Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Lü = aluminium) V PVC outer sheath 22 Steel tape armoured (double steel tape) 3×400 mm² Three cores, each ...
3コア 中圧電源ケーブル 重用 185mm2 装甲型XLPEケーブル
Heavy Duty Aluminum Cable 3 Core 185mm² YJLV22 8.7/10kV Armored XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...
輸送ハブ 主電源ケーブル YJV22 3x240mm² 8.7/15kV アーマード MV XLPE
Transport Hub Main Power Cable YJV22 3x240mm² 8.7/15kV Armored MV XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...