"flat sheathed wires flat electrical sheathed wires"
Please try a different search term or browse our product categories.
1.0mm2 Condutor de cobre sólido Annealed 18 Awg Barre de cobre
BV 1.0 mm² / 18 AWG — Technical Specification Category Parameter Value / Description Product Identity Model Number BV (equivalent to 60227 IEC 01 / IEC 05) Product Name Copper Conductor PVC Insulated Single-Core Building Wire Standards Compliance GB/T 5023.3-2008, JB/T 8734.2-2016 Certification CCC ...
Cabo Solar Principal PV1-F 6.0mm² TUV 1500V DC Fio Fotovoltaico PV Pesado
Solar Main Cable PV1-F 6.0mm² TUV 1500V DC Heavy Duty PV Photovoltaic Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor, ...
Cabo PV String PV1-F 4.0mm² TUV 1500V DC Fio de Painel Solar Resistente a UV
PV String Cable PV1-F 4.0mm² TUV 1500V DC UV Resistant Solar Array Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 4.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor, ...
XLPE Aluminum Power Cable YJLV22 3x50mm2 8.7/15kV Armored 3 Core MV
XLPE Aluminum Power Cable YJLV22 3x50mm² 8.7/15kV Armored 3 Core MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...
Cabo de alimentação principal do centro de transporte YJV22 3x240mm2 8.7/15kV MV XLPE blindado
Transport Hub Main Power Cable YJV22 3x240mm² 8.7/15kV Armored MV XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...
Cabos de transmissão ultra pesados YJV22 3x185mm2 8.7/15kV Cabos de transmissão blindados XLPE
Ultra Heavy MV Cable YJV22 3x185mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...
Cabo MV de Bitola Pesada YJV22 3x150mm² 8.7/15kV Cabo de Energia Blindado XLPE
Heavy Gauge MV Cable YJV22 3x150mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...
Cabo à Prova de Fogo 4x185mm2+1x150mm2 0.6KV 1KV Cabo de Cobre com Isolamento Mineral
Super Fire Cable BTTRZ 4x185mm²+1x150mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...