"flat sheathed wires flat electrical sheathed wires"
Please try a different search term or browse our product categories.
Cavo media tensione 3x400mm2 Armato XLPE Filo XLPE 26KV 35kV
YJLV22 3x400mm² Aluminum XLPE Armored HV Cable 26/35kV for Urban Power Distribution Cable Designation & Meaning Code Meaning 26/35 kV Rated voltage: U₀ = 26 kV (phase-to-earth), U = 35 kV (phase-to-phase) YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Lü = aluminium) V PVC ...
Cavo MV a neutra concentrica in alluminio 3x95mm2 Cavo armato in alluminio a 3 conduttori
Main Distribution Aluminum Cable YJLV22 3x95mm² 8.7/15kV Armored MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...
Cavo XLPE in alluminio YJLV22 3x70mm2 8.7/15kV Cavo di alimentazione MV blindato
Aluminum XLPE Cable YJLV22 3x70mm² 8.7/15kV Armored MV Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...
Cavo di alimentazione principale del centro di trasporto YJV22 3x240mm² 8.7/15kV Armored MV XLPE
Transport Hub Main Power Cable YJV22 3x240mm² 8.7/15kV Armored MV XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...
Cavo MV Ultra Pesante YJV22 3x185mm² 8.7/15kV Cavo di Alimentazione Armato XLPE
Ultra Heavy MV Cable YJV22 3x185mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...
Cavo di distribuzione primario 3 Core 70mm2 YJV22 8.7/10kV XLPE corazzato
Primary Distribution Cable 3 Core 70mm² YJV22 8.7/10kV Armored XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV; ...
BTLY Cavo Resistente al Fuoco 4x35mm2 + 1x16mm2 Cavo con Guaina in Alluminio per Emergenza
NG-A BTLY 4x35+1x16mm2 Mineral Insulated Fire Resistant Aluminum Sheath Cable for Emergency Cable Designation & Meaning Code Meaning NG-A New Generation A-class fire-resistant (Chinese designation) (BTLY) Building wire, Thin copper conductor, Lightweight Y— alternative naming convention indicating: ...
Cavo ignifugo 4x70mm2+1x50mm2 1KV 1.2KV Cavo minerale isolato in rame nudo
Heavy Duty Fire Cable BTTRZ 4x70mm²+1x50mm² Mineral Insulated 0.6/1kV Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV Rated ...