4.0mm2 Solid Tembaga Konduktor 450V 750V Single Stranded Wire Tembaga
BV 4.0mm² Solid Copper PVC Insulated Building Wire 450/750V Easy Pull Electrical Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 4.0 mm² Nominal cross-sectional area of conductor Construction: Plain copper conductor ...
Konduktor Tembaga Padat 2,5mm2 Ground Earth Solid Thhn Tahan Api
Yellow Green BV 2.5mm² Ground Earth Wire PVC Insulated Copper Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain copper conductor (solid or stranded)...
Kabel Surya Fotovoltaik Tembaga Berlapis Surya Panel Surya Tahan UV Kawat PV
Solar Panel Cable H1Z2Z2-K 4.0mm² TUV 1500V DC UV Resistant PV Wire Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) Z Halogen...
4.0mm2 Kabel fotovoltaik TUV Kabel fotovoltaik non-korosif 1500V
H1Z2Z2-K 4.0mm² TUV Certified Solar Cable 1500V DC Photovoltaic Wire Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) Z Halogen...
Kabel Surya DC 6.0mm² PV1-F TUV Tahan UV Kabel Fotovoltaik Kabel Utama String PV
DC Solar Wire 6.0mm² PV1-F TUV UV Resistant Photovoltaic Cable PV String Main Cable Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper ...
3x400mm2 Kabel Tegangan Menengah XLPE Armored XLPE Wire 26KV 35kV
YJLV22 3x400mm² Aluminum XLPE Armored HV Cable 26/35kV for Urban Power Distribution Cable Designation & Meaning Code Meaning 26/35 kV Rated voltage: U₀ = 26 kV (phase-to-earth), U = 35 kV (phase-to-phase) YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Lü = aluminium) V PVC ...
Kabel Aluminium Ringan 3 Inti 35mm2 YJLV22 8.7/10kV XLPE Lapisan
Lightweight Aluminum Cable 3 Core 35mm² YJLV22 8.7/10kV Armored XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...
Heavy Gauge MV Cable YJV22 3x150mm2 8.7/15kV Armored XLPE Power Cable
Heavy Gauge MV Cable YJV22 3x150mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...