"flat sheathed wires flat electrical sheathed wires"
Please try a different search term or browse our product categories.
Przewód elastyczny RVV 5x4.0mm2 5-żyłowy z PVC, wielożyłowy, linka miedziana
RVV 5x4.0mm2 5 Core Flexible PVC Stranded Copper Cable 300/500V Multi Circuit Cable Designation & Meaning Code Meaning R Flexible conductor (Class 5 fine-stranded copper) V PVC (polyvinyl chloride) insulation V PVC (polyvinyl chloride) outer sheath 5×4.0 mm² Five cores, each 4.0 mm² flexible copper ...
Kabel fotowoltaiczny TUV 1kV H1Z2Z2-K 4mm2 Pv
1500V DC Solar Wire H1Z2Z2-K 4.0mm² TUV XLPE Photovoltaic Cable Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) Z Halogen-free ...
Płyty słoneczne fotovoltaiczne miedziane
Solar Panel Cable H1Z2Z2-K 4.0mm² TUV 1500V DC UV Resistant PV Wire Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) Z Halogen...
Kabel średniego napięcia 3x400mm2 XLPE opancerzony XLPE 26KV 35kV
YJLV22 3x400mm² Aluminum XLPE Armored HV Cable 26/35kV for Urban Power Distribution Cable Designation & Meaning Code Meaning 26/35 kV Rated voltage: U₀ = 26 kV (phase-to-earth), U = 35 kV (phase-to-phase) YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Lü = aluminium) V PVC ...
3x240mm2 Elastyczny kabel średniego napięcia 8,7kV 15kV 3-żyłowy
XLPE Medium Voltage Aluminum Cable YJLV22 3x240mm2 8.7/15kV Armored 3 Core Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 ...
Ciężki kabel MV YJV22 3x150mm2 8,7/15kV Cable XLPE
Heavy Gauge MV Cable YJV22 3x150mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...
Mega Industrial Main Cable YJV22 3x120mm2 8,7/15kV Pancerny MV XLPE
Mega Industrial Main Cable YJV22 3x120mm² 8.7/15kV Armored MV XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV; U...
3 rdzenia Cable Pancerny MV YJV22 3x50mm2 8.7/10kV 8.7/15kV XLPE Kabel zasilania
3 Core Armored MV Cable YJV22 3x50mm² 8.7/10kV 8.7/15kV XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...