Equipment Grounding Cord RVV 3x1.0mm² PVC Stranded Copper Flexible
Cable Designation & Meaning
|
Code |
Meaning |
|---|---|
|
RVV |
R = Flexible copper conductor (Class 5), V = PVC insulation, V = PVC sheath |
|
300/500 V |
Rated voltage U₀/U = 300/500 V; Uₘ = 500 V |
|
3×1.0 mm² |
Three flexible cores, each 1.0 mm² copper conductor |
Construction: Light PVC sheathed flexible cord, round profile (3-core)


RVV 3×1.0 mm² — Cable Specification & Engineering Data (English)
1. Product Overview & Rating Summary. RVV 3×1.0 is a three-core flexible PVC-insulated PVC-sheathed cord rated at 300/500 V AC (50 Hz) and 70 °C conductor temperature, built around three 1.0 mm² annealed copper Class 5 flexible conductors — each PVC-insulated and collectively jacketed in a second PVC oversheath. Manufactured and type-tested to GB/T 5023.5 (60227 IEC 52) / IEC 60227-5, with flexible conductors per GB/T 3956. Finished diameter is about 7.9 mm and nominal mass about 110 kg/km (≈ 11 kg per 100 m), supplied on 100 m reels or cartons. With all three cores energised, the cord carries about 10 A in free air at 25 °C (engineering estimate) — a step up in current capacity versus the 3×0.75 variant.
2. Layer-by-Layer Construction (Conductor to Jacket).
| Layer | Construction | Wall | Diameter |
|---|---|---|---|
| Conductor (Cu) × 3 | Annealed Cu, Class 5 flexible stranded, 32 × 0.20 mm (1+6+12+13) each | — | ≈ 1.4 mm |
| Insulation (PVC) × 3 | PVC compound, PVC/C (TI1) | 0.60 mm | ≈ 2.6 mm |
| Core assembly | Three insulated cores cabled in triangular lay-up; interstices filled by sheath extrusion | — | ≈ 6.3 mm (derived) |
| Outer sheath (PVC) | PVC compound, PVC/ST5, black or custom | 0.80 mm | ≈ 7.9 mm (finished) |
3. Electrical Characteristics. Each 1.0 mm² conductor is held to a maximum DC resistance of 19.5 Ω/km at 20 °C, rising to around 24.8 Ω/km at the 70 °C operating point. Every length survives the routine 2.0 kV AC power-frequency proof held for five minutes. Finished-cable insulation resistance remains above 0.011 MΩ·km at 70 °C, and typical figures include capacitance ≈ 100 nF/km and 50 Hz AC impedance ≈ 19.5 Ω/km (resistance-dominant). With all three cores energised, reference loading is about 10 A in free air at 25 °C (engineering estimate), and the loop voltage drop at 10 A is about 0.39 V per metre.
Electrical Parameters
|
Parameter |
Value |
Note |
|---|---|---|
|
Rated voltage U₀/U |
300 / 500 V |
Uₘ = 500 V |
|
Test voltage AC (5 min) |
2.0 kV |
Routine |
|
Type-test voltage |
2.5 kV |
IEC 60227 |
|
DC resistance @20 °C (per core) |
≤ 19.5 Ω/km |
GB/T 3956 Class 5 max, 1.0 mm² |
|
AC resistance @70 °C (est.) |
≈ 24.9 Ω/km |
per core |
|
Current rating in air (single-phase, 30 °C, L+N) |
≈ 8 – 12 A |
total current on L, N carries return |
|
Current rating (design, per core) |
≈ 10 A |
conservative, per GB/T 16895 |
|
Current rating (3-phase, balanced) |
≈ 7 – 10 A per phase |
derated due to bundling |
|
Direct buried |
Not applicable |
light cord, not for direct burial |
|
Short-circuit current (1 s, Cu, 160 °C) |
≈ 0.10 kA (100 A) |
1.0 mm² reference |
|
Frequency |
50/60 Hz AC or DC |
— |
4. Thermal Response & Flame Behaviour. PVC insulation sustains a 70 °C continuous conductor temperature. The cord is rated for service ambients between −15 and +70 °C, must not be uncoiled below 0 °C without pre-conditioning, and uses 25 °C as the reference ambient for ampacity. Flame behaviour meets the single-cable vertical test GB/T 18380.12 (IEC 60332-1), meaning the cord self-extinguishes when the flame source is removed. Because both insulation and sheath are halogenated PVC, the cord emits smoke and hydrogen chloride in a fire; low-smoke zero-halogen projects must specify an LSZH variant.

5. Installation Practice & Handling. Bends must not fall below 6 times the actual outer diameter — about 50 mm for this size. Termination requires stripping 10–12 mm and always using a ferrule on the flexible Class 5 strands to prevent wire fraying. Reels held below 0 °C in storage must be warmed indoors before uncoiling; pulling tension should stay within 60 N, and the cord must never be used as a pulling rope. The 10 A reference requires derating whenever ambient temperature or bundling deviates from reference conditions. This cord is not for direct burial, outdoor UV exposure or continuous repetitive flexing — for those duties choose an armoured cable, a UV-stabilised jacket or a continuous-flex (trunking) cable respectively.
Cable Cross Section Structure


Cable Construction Description

6. Typical Service Applications. This cord serves light-to-medium three-wire power and control duties: appliance supply leads up to about 10 A, small tool and vacuum-cleaner power cords, luminaire and lighting-circuit wiring with earth, office equipment and peripheral leads, router/modem and small UPS supply cords, control panel and sensor interconnect, low-current industrial signal/power drops, and extension cord internal wiring. Approved installation methods include fixed wiring inside appliances, cable trunking and indoor ducting in dry locations, both indoors and in covered sheltered spaces.

7. Testing & Quality Assurance Regime. Routine tests on every length include conductor DC resistance verification (≤ 19.5 Ω/km at 20 °C), the 2.0 kV AC / 5 min withstand, conductor continuity across all three cores, and dimensional inspection covering insulation ≥ 0.60 mm, sheath ≥ 0.80 mm and overall diameter ≈ 7.9 mm. Sample and type tests comprise PVC insulation and sheath tensile strength (≥ 10 MPa) with elongation (≥ 100 % insulation / ≥ 125 % sheath), PVC heat deformation at 80 °C, PVC shrinkage at 150 °C, the single-cable vertical flame test, bending and cold-bend tests at −15 °C, and the voltage test after flexing. A factory test certificate accompanies each reel.
Cable Parameters

Cable Test Parameters

8. Standards & Conformity. Design and production are governed by GB/T 5023.5 and IEC 60227-5 for 300/500 V flexible cords (60227 IEC 52). Conductors satisfy GB/T 3956 / IEC 60228 Class 5 — the 1.0 mm² conductor as thirty-two wires of 0.20 mm with R ≤ 19.5 Ω/km. Flame behaviour is proven by GB/T 18380.12. General test methods follow GB 5023.1 / GB 5023.3, while surface marking complies with GB/T 6995. Cables can also be supplied to IEC, BS, DIN, UL or VDE requirements on request. Because the PVC jacket contains halogen, tunnels, metro systems, hospitals and other confined public areas call for an LSZH variant.
Standards System
|
Standard |
Type |
Scope |
Key Requirement |
|---|---|---|---|
|
GB/T 19666-2019 |
Product |
General rules for flame retardant & fire resistant wires/cables |
Defines ZA, ZB, ZC, ZD classifications |
|
GB/T 18380.31~36-2022 |
Test Method |
Flame propagation test for bunched wires/cables |
Test method for ZA~ZD rating |
|
GB 31247-2014 |
Fire Class |
Combustion performance classification of cables in buildings |
Defines A, B1, B2, B3 classes (different from ZA~ZD) |
|
IEC 60332-3 |
Test Method |
Tests on electric cables under fire conditions |
International equivalent of GB/T 18380 |
|
IEC 60754-1/2 |
Test Method |
Test on gases evolved during combustion |
Halogen acid gas emission test |
|
IEC 61034-2 |
Test Method |
Measurement of smoke density |
Light transmittance test |
|
GB/T 12666.1~7 |
Test Method |
Various burning tests |
Single vertical, horizontal, etc. |
9. Packaging, Storage & Logistics. Standard delivery is 100 m per reel or carton, with bespoke cut lengths available on request. Each reel carries type, voltage, supplier identity, production year and sequential metre marking per GB/T 6995. Storage should be in dry, covered premises at −15 to +40 °C, shielded from direct sunlight, moisture, oils and sharp objects; reels remain sealed until installation. In cold conditions, condition reels indoors to ≥ 0 °C before uncoiling. During transit, reels must be secured against rolling and impact, and the cord must never be dragged across abrasive ground or sharp edges.

10. Procurement Specification. State "RVV 300/500 V 3×1.0" together with the required length or reel arrangement, insulation colour combination and marking preferences. Specify the sheath colour (black is standard) and any special colour-coding (e.g. brown/blue/yellow-green for 230 V supply with earth). Always request the factory test certificate to confirm the actual diameter (≈ 7.9 mm), weight (≈ 110 kg/km) and conductor resistance for the production batch. Where low-smoke zero-halogen or continuous-flex construction is needed, order the LSZH or H05VV5-F variant respectively.
11. Cable Industry FAQ.
- Q1: How does 3×1.0 differ from 3×0.75? Conductor area grows from 0.75 to 1.0 mm² per core: stranding changes from 24×0.20 to 32×0.20, resistance falls from 26.0 to 19.5 Ω/km, finished diameter rises from 7.1 to 7.9 mm, weight from 85 to 110 kg/km and ampacity from 6 to 10 A. Voltage rating, temperature rating and sheath/insulation material stay the same.
- Q2: Why a three-core cord with 1.0 mm²? The third core is the protective earth conductor (PE), while the 1.0 mm² cross-section supports up to about 10 A — enough for small appliances, tools and lighting branches rather than just signal circuits.
- Q3: What does Class 5 flexible conductor mean? Class 5 (GB/T 3956) is made of many thin wires (32 × 0.20 mm at 1.0 mm²), giving the cord its flexibility and bend endurance. Class 2 (used in power cables like YJV) uses fewer thicker wires and is much stiffer — never mix them up when ordering.
- Q4: Can RVV be used outdoors? Not in its standard form: the PVC jacket is not UV-stabilised and will degrade under prolonged sunlight. For outdoor use specify a UV-stabilised jacket or an armoured cable. For burial, use a steel-tape armoured power cable.
- Q5: How is the conductor cross-section chosen for an appliance lead? Selection follows (a) full-load current after derating, (b) permissible voltage drop (typically ≤ 5 % for appliance leads), and (c) coordination with the upstream fuse or circuit breaker. A 1.0 mm² cord supports up to about 10 A; higher loads require 1.5 or 2.5 mm².
- Q6: Copper or tinned copper conductor? Bare annealed copper (this RVV) is standard for fixed appliance leads and gives the lowest resistance. Tinned copper is preferred where the conductor may be exposed to moisture or where solder termination is used, because it resists oxidation.
- Q7: Why can PVC only run at 70 °C while XLPE runs at 90 °C? PVC is a thermoplastic that softens and deforms at elevated temperature; XLPE is cross-linked into a thermoset network that retains its shape up to 90 °C. This is why RVV (PVC) is limited to 70 °C and YJV (XLPE) to 90 °C.
- Q8: What is the difference between RVV and RVVP? RVV is the plain unshielded round flexible cord. RVVP adds a tinned-copper braid screen for electromagnetic interference rejection — choose the shielded variant when the circuit carries low-level signals or is routed near noisy equipment.
- Q9: Why does finished diameter vary between manufacturers for the same nominal size? Standards set minimum insulation and sheath thicknesses plus electrical performance, but not a precise overall diameter. Stranding compaction, filler design and sheath tolerance differ between plants — published 3×1.0 figures cluster around 7.9 mm — so the actual measured diameter must be used when sizing glands and clips.
- Q10: Which tests confirm acceptability on delivery and before energisation? At delivery, verify the factory test certificate (resistance ≤ 19.5 Ω/km, 2.0 kV/5 min withstand, dimensions ≈ 7.9 mm), jacket legibility and reel integrity. After installation, complete an insulation-resistance test plus a 2.0 kV AC / 5 min withstand, then confirm all three conductors identified correctly before energising.
- Q11: What service life can be expected? When installed and operated within the stated temperature and voltage limits, PVC flexible cords are designed for a service life of around 10–15 years in dry indoor conditions; sustained overload, repeated flexing beyond the 6 × OD minimum radius, ultraviolet exposure, or operation above 70 °C will materially shorten that life.