Polyolefin Single Core Earth Cable ZR-YJV 1 X 35mm2 Single Conductor 0.6/1kV Indoor Power
Product Summary
Product Details
Polyolefin single core earth cable
,single core earth cable ZR-YJV
,0.6/1kV 35mm single core cable
Product Description
Polyolefin Single Core Earth Cable ZR-YJV 1 X 35mm2 Single Conductor 0.6/1kV Indoor Power
Cable Designation & Meaning
|
Code |
Meaning |
|---|---|
|
ZC |
Flame retardant Class C |
|
YJ |
Cross-linked polyethylene (XLPE) insulation |
|
V |
Polyvinyl chloride (PVC) sheath |
|
1×35 mm² |
One core of 35 mm² copper conductor |
Construction: Single copper conductor, XLPE insulation, PVC outer sheath. No metallic screen/armour as standard (can be added on request).

ZC-YJV 1×35 mm² — LV Flame-Retardant Power Cable — Specification
1. Overview & Ratings. ZC-YJV 1×35 is a compact single-core LV power cable rated 0.6/1 kV (Um 1.2), 90 °C working, with a ZC class C flame-retardant PVC sheath. One compacted 35 mm² copper core, XLPE insulation, unscreened. OD ≈ 12.5 mm, ≈ 430 kg/km, ≈ 120 A (air, 30 °C) — a lighting-branch, socket-ring and small-power feed; ZC self-extinguishes but is not a 950°C fire-rated circuit.
2. Construction Stack (Inner → Outer).
| Layer | Build | Function |
|---|---|---|
| Conductor | 1×35 compacted Cu, Class 2, ≈7 strands | Power core |
| XLPE insulation | Cross-linked PE, ≈1.0 mm | 90 °C dielectric |
| PVC ZC sheath | Flame-retardant class C, ≈1.4 mm | Protection, self-extinguish |
3. Electrical Characteristics. Core R ≤ 0.524 Ω/km @20 °C. Test 3.5 kV AC / 5 min; nominal ≈ 120 A (air, 30 °C); short-circuit ≈ 3.1 kA / 1 s; 50/60 Hz; unscreened; insulation resistance high and stable.
Insulation & Sheath Data
|
Property |
Value |
|---|---|
|
Insulation material |
XLPE (cross-linked polyethylene) |
|
Outer sheath material |
PVC (ST₂) |
|
Long-term service temp. |
90 °C (continuous) |
|
Max. conductor temp. (normal) |
90 °C |
|
Short-circuit temp. (≤5 s) |
250 °C |
|
Emergency overload temp. |
130 °C (≤1 h) |
|
Test voltage AC (5 min) |
3.5 kV |
|
Dielectric strength |
≥ 20 kV/mm |
|
Volume resistivity @20 °C |
≥ 1×10¹⁴ Ω·cm |
|
Shield |
None as standard (can be added) |
Electrical Parameters
|
Parameter |
Value |
Note |
|---|---|---|
|
Rated voltage U₀/U |
0.6 / 1 kV |
GB/T 12706.1 / IEC 60502-1 |
|
Max. system voltage |
1.2 kV AC |
— |
|
Test voltage AC (5 min) |
3.5 kV |
Routine test |
|
DC resistance @20 °C |
≤ 0.524 Ω/km |
GB/T 3956 Class 2 Cu max |
|
AC resistance @90 °C (est.) |
≈ 0.672 Ω/km |
— |
|
Current rating in air (30 °C) |
Phase: 150 A |
single-core, touching, in free air |
|
Current rating in tray (30 °C) |
Phase: 165 A |
single-core, spaced 2×OD |
|
Current rating buried in ground (20 °C, thermal resistivity 1.2 K·m/W) |
Phase: 155 A |
direct buried |
|
Current rating in conduit (30 °C) |
Phase: 135 A |
— |
|
Short-circuit current (1 s, Cu, 250 °C) |
≈ 3.9 kA (3,900 A) |
— |
|
Capacitance (core-to-sheath, approx.) |
≈ 0.15 µF/km |
XLPE |
|
Inductive reactance (approx.) |
≈ 0.07 Ω/km |
at 50 Hz |
|
Frequency |
50/60 Hz AC |
— |
Reference values: 1×35 at 150 A, single-phase 230 V → max load ≈ 34 kW (cos φ = 0.8). Suitable for control circuits, small power distribution, and lighting feeders.
4. Thermal & Flame. 90 °C continuous, 250 °C short-time; ZC class C self-extinguishing on removal of flame — flame retardancy, not 950°C integrity; ambient 0~+40 °C; indoor/tray/conduit; use UV grade if exposed.
Temperature Characteristics
|
Property |
Value |
|---|---|
|
Max. conductor operating temp. |
90 °C (continuous) |
|
Max. short-circuit temp. (≤5 s) |
250 °C |
|
Emergency overload temp. |
130 °C (≤1 h) |
|
Min. installation ambient temp. |
0 °C (below 0 °C requires preheating) |
|
Service ambient range |
−20 °C to +90 °C |
|
Flexing temp. range |
0 °C to +90 °C |
Fire Performance (ZC-YJV — Flame Retardant C)
|
Property |
Value / Requirement |
|---|---|
|
Flame retardant |
GB/T 18380.12 / IEC 60332-1-2 (single cable, self-extinguishing) |
|
Flame retardant class |
Class C (ZC) per GB/T 19666 |
|
Halogen content |
Contains halogen (PVC sheath) |
|
Smoke density |
Not low-smoke (PVC) |
|
Corrosivity |
Corrosive (PVC) |
|
Toxicity |
Toxic fumes when burned (PVC) |
|
EMI shielding |
None (no metallic screen/armour) |
5. Installation Practice & Handling. Standard Cu lugs and glands; bend ≥ 15×OD ≈ 188 mm; derate in bundled conduit/tray; light reel suits short branch pulls; continuity and insulation after laying; cold bending not below 0 °C.
Mechanical & Installation Parameters
|
Parameter |
Value |
Remarks |
|---|---|---|
|
Minimum bending radius |
≥ 15 × OD → ≈ 203 mm at Ø13.5 mm |
single-core unarmoured |
|
Max. pulling tension |
525 N (35 mm² × 15 N/mm²) |
Cu conductor limit |
|
Direct burial |
Suitable (with sand bedding) |
— |
|
Surface mounting |
Excellent (cable tray, ladder, cleats) |
— |
|
Conduit ID |
≥ 20 mm |
— |
|
Fixing |
cable ties, cleats |
— |
|
Impact resistance |
Moderate |
— |
|
Water resistance |
Good (PVC sheath) |
— |
|
UV resistance |
Fair (PVC degrades outdoors, use UV-resistant PVC or conduit) |
— |
|
Flex life |
Good (Class 2 stranded) |
fixed installation |
|
Termination note |
Standard compression lugs or mechanical connectors |
— |
6. Typical Service Applications. Lighting branches, socket ring mains, small power feeds, panel internal runs, sub-distribution branches, general indoor LV wiring.

7. Testing & QA Regime (14 items). Routine: DC resistance, 3.5 kV withstand, insulation resistance, continuity, sheath/insulation thickness, dimensional check, conductor construction, insulation eccentricity, sheath appearance, printing legibility, mass per unit length. Type: ZC class C flame test, short-circuit rating.
Cable Parameter
| ZC-YJV 1×35 mm² — LV Flame-Retardant Power Cable — Full Parameter Sheet | |||
| Cu conductor / XLPE insulation / PVC sheath · ZC flame-retardant class C · 0.6/1 kV · ≈ 12.5 mm · lighting branch, socket & small power feed | |||
| Parameter | Value | Unit | Remarks / Standard |
| 01 · Identification | |||
| Cable type | ZC-YJV — Cu / XLPE / PVC, flame-retardant class C | — | LV power |
| Rated voltage (U0/U) | 0.6/1 | kV | Low voltage |
| Maximum operating voltage (Um) | 1.2 | kV | Phase-to-earth |
| Core configuration | 1×35 | — | Single core |
| Conductor material | Compacted stranded annealed copper | — | Class 2 |
| Insulation | XLPE cross-linked polyethylene | — | 90°C |
| Sheath | PVC, flame-retardant class C (ZC) | — | Warm graphite |
| Flame retardancy | ZC class C (self-extinguishing, not fire-rated) | — | Flame retardant |
| Suitable for | Fixed indoor wiring, tray, conduit, trunking | — | Power |
| Application | Lighting branch, socket ring, small power feed | — | General |
| 02 · Conductors | |||
| Power core | 1 × 35 | mm² | Single |
| Conductor type | Compacted stranded Cu, Class 2 | — | Round |
| DC resistance (35) @ 20°C | ≤ 0.524 | Ω/km | Cu 35 |
| Stranding | Layer-compacted, concentric | — | Stable OD |
| Strands (nom., est.) | ≈ 7 compacted | — | Class 2 |
| Surface | Bare copper, tinned optional | — | Contact |
| 03 · Insulation | |||
| Insulation material | XLPE (cross-linked PE) | — | 90°C rated |
| Insulation thickness (nom.) | ≈ 1.0 | mm | Single-core |
| Working conductor temp. | 90 | °C | Normal |
| Short-circuit temp. | 250 | °C | Max, short time |
| Insulation resistance | High and stable | MΩ·km | XLPE |
| Color | Natural / phase color on request | — | Identification |
| 04 · Sheath & Flame Retardancy | |||
| Sheath material | PVC, flame-retardant ZC | — | Class C |
| Sheath thickness (nom.) | ≈ 1.4 | mm | Overall |
| Finished outer diameter | ≈ 12.5 | mm | Single core |
| Flame behavior | Self-extinguishing, class C | — | Not 950°C fire-rated |
| Sheath color | Warm graphite (other on request) | — | Marking |
| 05 · Electrical | |||
| Rated voltage (U0/U) | 0.6/1 | kV | LV |
| Max voltage (Um) | 1.2 | kV | Phase-to-earth |
| Nominal current (35 core) | ≈ 120 | A | Air, 30°C |
| Test voltage (AC) | 3.5 kV / 5 min | — | Routine |
| Insulation resistance | High, XLPE | MΩ·km | Stable |
| Short-circuit current (35, 1s) | ≈ 3.1 | kA | Copper |
| Frequency | 50 / 60 | Hz | General |
| 06 · Thermal & Environment | |||
| Normal conductor temp. | 90 | °C | Continuous |
| Installed ambient | 0 ~ +40 | °C | Indoor/tray |
| Min install temp. | 0 | °C | Cold bending |
| Burning | Self-extinguishing, ZC class C | — | Flame retardant |
| Outdoor / UV | Indoor preferred; use UV grade if exposed | — | PVC limit |
| Oil / chemicals | Resistant to common oils; check aggressive media | — | General |
| 07 · Mechanical & Construction | |||
| Min bending radius (fixed) | ≥ 15 × OD ≈ 188 | mm | Single-core |
| Flexibility | Flexible stranded, compact, easy to pull | — | Handy |
| Shielding | None (unscreened power) | — | General |
| Cable weight per km | ≈ 430 | kg/km | Light Cu core |
| Circularity | Compacted round, stable OD | — | Conduit fit |
| 08 · Factory Advantages | |||
| Fine compacted core | Small strand bundle lays round for tight conduit | — | Easy route |
| Stable XLPE cure | Even cross-linking, consistent 90°C dielectric | — | Reliable insulation |
| Dosed ZC compound | Flame-retardant PVC self-extinguishes to class C | — | Safety margin |
| Length-on-demand | Cut to exact meter, sealed ends, minimal offcut | — | No waste |
| Batch resistance log | Per-core DC R recorded against lot number | — | Traceable |
| Continuous print line | Voltage, size, ZC, meter length along jacket | — | Clear ID |
| Phase-color option | Insulation/jacket color matched to phase code | — | Fast wiring |
| Light & hand-pull | 430 kg/km reel suits short branch pulls | — | Fast install |
| 09 · Installation | |||
| Laying | Tray, conduit, trunking, lighting branch | — | Power |
| Connectors | Cu lugs, standard glands | — | General |
| Bend radius | ≥ 15×OD ≈ 188 mm | — | Single-core |
| Parallel runs | Derate when bundled in conduit/tray | — | Load |
| Site test | Continuity + insulation post-laying | — | Commissioning |
| 10 · Packing & Applications | |||
| Supply length | Custom / wooden drum or coil | m | Light |
| Reel type | Standard wooden drum / coil | — | Handy |
| Surface marking | ZC-YJV, 1×35, 0.6/1kV, ZC, length | — | Marking |
| Typical use | Lighting branch, socket ring, small power feed | — | Power |
Cable Test Parameters
| Test Parameters — ZC-YJV 1×35 LV Flame-Retardant Cable | ||||
| No. | Test Item | Test Condition / Method | Requirement | Type |
| 1 | Conductor DC resistance | 20 °C, core | 35 ≤0.524 Ω/km | Routine |
| 2 | Voltage test (AC) | 3.5 kV AC, 5 min | No breakdown | Routine |
| 3 | Insulation resistance | XLPE, 20°C | High & stable | Routine |
| 4 | Continuity | Core | Continuous | Routine |
| 5 | Flame retardancy | Class C vertical test | Self-extinguish | Type |
| 6 | Sheath thickness | Micrometer | Nominal ≥1.4 mm | Routine |
| 7 | Insulation thickness | Micrometer | Nominal ≥1.0 mm | Routine |
| 8 | Dimensional check | Caliper | OD ≈ 12.5 mm | Routine |
| 9 | Conductor construction | Visual / strand count | Class 2 compacted | Routine |
| 10 | Short-circuit rating | Calculated / type | 3.1 kA / 1 s | Type |
| 11 | Insulation eccentric test | Cross-section measure | Within tolerance | Routine |
| 12 | Sheath appearance | Visual | Smooth, no flaw | Routine |
| 13 | Printing legibility | Visual | Marking readable | Routine |
| 14 | Mass per unit length | Weigh / calculate | ≈ 430 kg/km | Routine |
Cable Cross Section Structure

| ZC-YJV 1×35 — Cross-Section Construction Diagram (Schematic) | |||||
| Cu core / XLPE insulation / PVC ZC sheath · 0.6/1 kV · ZC class C flame retardant · ≈ 12.5 mm · lighting branch & socket ring | |||||
| No. | Layer | Material / Construction | Nominal Thickness (mm) | Diameter (mm) | Function / Remarks |
| 1 | Conductor | 1×35 compacted Cu, Class 2, ≈7 strands | — | ≈ 8 | Power core |
| 2 | XLPE insulation | Cross-linked PE | ≈ 1.0 | ≈ 10.5 | 90°C dielectric |
| 3 | PVC sheath | ZC flame-retardant | ≈ 1.4 | ≈ 12.5 | Protection |
| Key Dimensions & Properties (expanded) | |||||
| Finished cable diameter | ≈ 12.5 | mm | Single core | ||
| Approx. cable mass | ≈ 430 | kg/km | Light Cu core | ||
| Nominal voltage rating | 0.6/1 | kV | LV | ||
| Max voltage (Um) | 1.2 | kV | Phase-earth | ||
| Normal conductor temp. | 90 | °C | Continuous | ||
| Short-circuit temp. | 250 | °C | Short time | ||
| Flame retardancy | ZC class C, self-extinguishing | — | Not fire-rated | ||
| Min bending radius (fixed) | ≥ 15 × OD ≈ 188 | mm | Single-core | ||
| DC resistance (35) | ≤ 0.524 | Ω/km | Cu 35 | ||
| Nominal current (35 core) | ≈ 120 | A | Air, 30°C | ||
| Short-circuit rating (1s) | ≈ 3.1 | kA | 35 Cu | ||
| Frequency | 50 / 60 | Hz | General | ||
| Core configuration | 1×35 | — | Single | ||
| Application | Lighting, socket, small power | — | Power | ||
| Schematic — not to exact scale. OD ≈12.5 mm and weight ≈430 kg/km from cross-referenced industry samples. ZC-YJV 1×35 is a general LV flame-retardant power cable for lighting branches, socket rings and small power feeds; ZC class C self-extinguishes but is not 950°C fire-rated. Values marked (est.) require confirmation against the factory test certificate. | |||||
Cable Construction Description
| Construction Description — ZC-YJV 1×35 LV flame-retardant power cable | |||
| Cu core / XLPE insulation / PVC ZC sheath · 0.6/1 kV · ZC class C · 90°C · ≈12.5 mm · lighting branch & socket ring | |||
| 1. Product Identity & Ratings | |||
| ZC-YJV 1×35 rated 0.6/1 kV (Um 1.2), 90°C working, ZC class C flame retardant. OD ≈12.5 mm, ≈430 kg/km, ≈120 A, drum or coil. | |||
| 2. Copper Conductor (1×35) | |||
| Single 35 mm² compacted Class 2 Cu core, ≈7 concentric strands; DC R ≤0.524 Ω/km @20°C; tinned optional. | |||
| 3. XLPE Insulation | |||
| Cross-linked PE ≈1.0 mm gives a stable 90°C dielectric; short-circuit limit 250°C; phase color on request. | |||
| 4. PVC ZC Sheath | |||
| Flame-retardant PVC ≈1.4 mm, self-extinguishing class C; warm graphite finish; indoor/tray use. | |||
| 5. Factory Advantages | |||
| • Fine compacted round core, tight conduit. • Stable XLPE cure. • Dosed ZC self-extinguish. • Cut to exact meter. • Per-batch resistance log. • Continuous clear print. • Phase-color option. • Light & hand-pull at 430 kg/km. | |||
| 6. Site Handling Notes | |||
| • Bend 15×OD (≈188 mm). • Cu lugs, standard glands. • Derate in conduit. • Indoor; UV grade if exposed. • Continuity + insulation after laying. |
8. Factory Advantages.
- Fine compacted core — the small strand bundle lays round for a tight conduit fit.
- Stable XLPE cure — even cross-linking keeps the 90°C dielectric consistent lot to lot.
- Dosed ZC compound — flame-retardant PVC self-extinguishes to class C with a safety margin.
- Length-on-demand — cut to the exact meter with sealed ends and minimal offcut.
- Batch resistance log — per-core DC R recorded against the lot number for traceability.
- Continuous print line — voltage, size, ZC, and meter length marked along the jacket.
- Phase-color option — insulation or jacket color matched to the phase code for fast wiring.
- Light & hand-pull — at 430 kg/km the reel suits short branch pulls with standard handling.

9. Packaging, Storage & Logistics. Standard wooden drum or coil; continuous marking (ZC-YJV, 1×35, 0.6/1kV, ZC, length). Store dry, indoor; avoid UV; light reels handle easily.

10. Procurement Specification. State "ZC-YJV 1×35", length, class C, and phase-color need; note it is flame retardant, not fire-rated; request the per-batch resistance log.