Polyolefin Single Core Earth Cable ZR-YJV 1 X 35mm2 Single Conductor 0.6/1kV Indoor Power

Polyolefin Single Core Earth Cable ZR-YJV 1 X 35mm2 Single Conductor 0.6/1kV Indoor Power

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
ZR-YJV 1*35mm²

Trading Properties

moq
100 meters
payment method
L/C,T/T
supply capacity
100000 meters per month

Product Summary

Polyolefin Single Core Earth Cable ZR-YJV 1 X 35mm2 Single Conductor 0.6/1kV Indoor Power Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 1×35 mm² One core of 35 mm² copper conductor Construction: ...

Product Details

Highlight:

Polyolefin single core earth cable

,

single core earth cable ZR-YJV

,

0.6/1kV 35mm single core cable

Conductor:
Bare Annealed Copper, Class 2 Stranded Circular, 7×∅2.52 Mm​ (typical), Conductor Ø ≈ 7.5 Mm
Conductor nominal area:
35 Mm²
Conductor construction:
Class 2, 7×∅2.52 Mm,min. 7 Wires Per GB/T 3956 (≤35 Mm²)
Conductor diameter (approx.):
7.5 Mm
Insulation:
XLPE Compound, Extruded
Insulation thickness (nominal):
0.9 Mm​ (GB/T 12706.1, 25–35 Mm² Class)
Diameter over insulation (approx.):
9.3 Mm(7.5 + 2×0.9)
Sheath nominal thickness:
1.4 Mm,single-core (some Makers 1.5)
Outer sheath:
Polyolefin (PO) Compound, Flame-retardant Grade (ZR)​
Filler / binder:
Flame-retardant (FR) Non-hygroscopic Tape / PP Mesh​
Long-term service temperature:
90 °C
Short-circuit temperature (≤5 s):
250 °C
Emergency overload:
105–130 °C (limited Duration)
Routine test:
3.5 KV AC / 5 Min; Type Test 4.0 KV
Volume resistivity @90 °C:
≥ 10¹² Ω·cm
Insulation resistance constant:
≈ 3.67 MΩ·km @90 °C

Product Description

Polyolefin Single Core Earth Cable ZR-YJV 1 X 35mm2 Single Conductor 0.6/1kV Indoor Power

Cable Designation & Meaning

Code

Meaning

ZC

Flame retardant Class C

YJ

Cross-linked polyethylene (XLPE) insulation

V

Polyvinyl chloride (PVC) sheath

1×35 mm²

One core of 35 mm² copper conductor


Construction: Single copper conductor, XLPE insulation, PVC outer sheath. No metallic screen/armour as standard (can be added on request).


Polyolefin Single Core Earth Cable ZR-YJV 1 X 35mm2 Single Conductor 0.6/1kV Indoor Power


ZC-YJV 1×35 mm² — LV Flame-Retardant Power Cable — Specification

1. Overview & Ratings. ZC-YJV 1×35 is a compact single-core LV power cable rated 0.6/1 kV (Um 1.2), 90 °C working, with a ZC class C flame-retardant PVC sheath. One compacted 35 mm² copper core, XLPE insulation, unscreened. OD ≈ 12.5 mm, ≈ 430 kg/km, ≈ 120 A (air, 30 °C) — a lighting-branch, socket-ring and small-power feed; ZC self-extinguishes but is not a 950°C fire-rated circuit.


2. Construction Stack (Inner → Outer).

Layer Build Function
Conductor 1×35 compacted Cu, Class 2, ≈7 strands Power core
XLPE insulation Cross-linked PE, ≈1.0 mm 90 °C dielectric
PVC ZC sheath Flame-retardant class C, ≈1.4 mm Protection, self-extinguish


3. Electrical Characteristics. Core R ≤ 0.524 Ω/km @20 °C. Test 3.5 kV AC / 5 min; nominal ≈ 120 A (air, 30 °C); short-circuit ≈ 3.1 kA / 1 s; 50/60 Hz; unscreened; insulation resistance high and stable.

Insulation & Sheath Data

Property

Value

Insulation material

XLPE (cross-linked polyethylene)

Outer sheath material

PVC (ST₂)

Long-term service temp.

90 °C (continuous)

Max. conductor temp. (normal)

90 °C

Short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Test voltage AC (5 min)

3.5 kV

Dielectric strength

≥ 20 kV/mm

Volume resistivity @20 °C

≥ 1×10¹⁴ Ω·cm

Shield

None as standard (can be added)

Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

GB/T 12706.1 / IEC 60502-1

Max. system voltage

1.2 kV AC

—

Test voltage AC (5 min)

3.5 kV

Routine test

DC resistance @20 °C

≤ 0.524 Ω/km

GB/T 3956 Class 2 Cu max

AC resistance @90 °C (est.)

≈ 0.672 Ω/km

—

Current rating in air (30 °C)

Phase: 150 A​

single-core, touching, in free air

Current rating in tray (30 °C)

Phase: 165 A​

single-core, spaced 2×OD

Current rating buried in ground (20 °C, thermal resistivity 1.2 K·m/W)

Phase: 155 A​

direct buried

Current rating in conduit (30 °C)

Phase: 135 A​

—

Short-circuit current (1 s, Cu, 250 °C)

≈ 3.9 kA (3,900 A)

—

Capacitance (core-to-sheath, approx.)

≈ 0.15 µF/km

XLPE

Inductive reactance (approx.)

≈ 0.07 Ω/km

at 50 Hz

Frequency

50/60 Hz AC

—


Reference values: 1×35 at 150 A, single-phase 230 V → max load ≈ 34 kW​ (cos φ = 0.8). Suitable for control circuits, small power distribution, and lighting feeders.


4. Thermal & Flame. 90 °C continuous, 250 °C short-time; ZC class C self-extinguishing on removal of flame — flame retardancy, not 950°C integrity; ambient 0~+40 °C; indoor/tray/conduit; use UV grade if exposed.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

90 °C (continuous)

Max. short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Min. installation ambient temp.

0 °C (below 0 °C requires preheating)

Service ambient range

−20 °C to +90 °C

Flexing temp. range

0 °C to +90 °C

Fire Performance (ZC-YJV — Flame Retardant C)

Property

Value / Requirement

Flame retardant

GB/T 18380.12 / IEC 60332-1-2​ (single cable, self-extinguishing)

Flame retardant class

Class C​ (ZC) per GB/T 19666

Halogen content

Contains halogen (PVC sheath)

Smoke density

Not low-smoke (PVC)

Corrosivity

Corrosive (PVC)

Toxicity

Toxic fumes when burned (PVC)

EMI shielding

None (no metallic screen/armour)


5. Installation Practice & Handling. Standard Cu lugs and glands; bend ≥ 15×OD ≈ 188 mm; derate in bundled conduit/tray; light reel suits short branch pulls; continuity and insulation after laying; cold bending not below 0 °C.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 15 × OD → ≈ 203 mm at Ø13.5 mm

single-core unarmoured

Max. pulling tension

525 N (35 mm² × 15 N/mm²)

Cu conductor limit

Direct burial

Suitable (with sand bedding)

—

Surface mounting

Excellent (cable tray, ladder, cleats)

—

Conduit ID

≥ 20 mm

—

Fixing

cable ties, cleats

—

Impact resistance

Moderate

—

Water resistance

Good (PVC sheath)

—

UV resistance

Fair (PVC degrades outdoors, use UV-resistant PVC or conduit)

—

Flex life

Good (Class 2 stranded)

fixed installation

Termination note

Standard compression lugs or mechanical connectors

—


6. Typical Service Applications. Lighting branches, socket ring mains, small power feeds, panel internal runs, sub-distribution branches, general indoor LV wiring.


Polyolefin Single Core Earth Cable ZR-YJV 1 X 35mm2 Single Conductor 0.6/1kV Indoor Power


7. Testing & QA Regime (14 items). Routine: DC resistance, 3.5 kV withstand, insulation resistance, continuity, sheath/insulation thickness, dimensional check, conductor construction, insulation eccentricity, sheath appearance, printing legibility, mass per unit length. Type: ZC class C flame test, short-circuit rating.


Cable Parameter


ZC-YJV 1×35 mm² — LV Flame-Retardant Power Cable — Full Parameter Sheet 
Cu conductor / XLPE insulation / PVC sheath · ZC flame-retardant class C · 0.6/1 kV · ≈ 12.5 mm · lighting branch, socket & small power feed
Parameter Value Unit Remarks / Standard
01 · Identification
Cable type ZC-YJV — Cu / XLPE / PVC, flame-retardant class C — LV power
Rated voltage (U0/U) 0.6/1 kV Low voltage
Maximum operating voltage (Um) 1.2 kV Phase-to-earth
Core configuration 1×35 — Single core
Conductor material Compacted stranded annealed copper — Class 2
Insulation XLPE cross-linked polyethylene — 90°C
Sheath PVC, flame-retardant class C (ZC) — Warm graphite
Flame retardancy ZC class C (self-extinguishing, not fire-rated) — Flame retardant
Suitable for Fixed indoor wiring, tray, conduit, trunking — Power
Application Lighting branch, socket ring, small power feed — General
02 · Conductors
Power core 1 × 35 mm² Single
Conductor type Compacted stranded Cu, Class 2 — Round
DC resistance (35) @ 20°C ≤ 0.524 Ω/km Cu 35
Stranding Layer-compacted, concentric — Stable OD
Strands (nom., est.) ≈ 7 compacted — Class 2
Surface Bare copper, tinned optional — Contact
03 · Insulation
Insulation material XLPE (cross-linked PE) — 90°C rated
Insulation thickness (nom.) ≈ 1.0 mm Single-core
Working conductor temp. 90 °C Normal
Short-circuit temp. 250 °C Max, short time
Insulation resistance High and stable MΩ·km XLPE
Color Natural / phase color on request — Identification
04 · Sheath & Flame Retardancy
Sheath material PVC, flame-retardant ZC — Class C
Sheath thickness (nom.) ≈ 1.4 mm Overall
Finished outer diameter ≈ 12.5 mm Single core
Flame behavior Self-extinguishing, class C — Not 950°C fire-rated
Sheath color Warm graphite (other on request) — Marking
05 · Electrical
Rated voltage (U0/U) 0.6/1 kV LV
Max voltage (Um) 1.2 kV Phase-to-earth
Nominal current (35 core) ≈ 120 A Air, 30°C
Test voltage (AC) 3.5 kV / 5 min — Routine
Insulation resistance High, XLPE MΩ·km Stable
Short-circuit current (35, 1s) ≈ 3.1 kA Copper
Frequency 50 / 60 Hz General
06 · Thermal & Environment
Normal conductor temp. 90 °C Continuous
Installed ambient 0 ~ +40 °C Indoor/tray
Min install temp. 0 °C Cold bending
Burning Self-extinguishing, ZC class C — Flame retardant
Outdoor / UV Indoor preferred; use UV grade if exposed — PVC limit
Oil / chemicals Resistant to common oils; check aggressive media — General
07 · Mechanical & Construction
Min bending radius (fixed) ≥ 15 × OD ≈ 188 mm Single-core
Flexibility Flexible stranded, compact, easy to pull — Handy
Shielding None (unscreened power) — General
Cable weight per km ≈ 430 kg/km Light Cu core
Circularity Compacted round, stable OD — Conduit fit
08 · Factory Advantages
Fine compacted core Small strand bundle lays round for tight conduit — Easy route
Stable XLPE cure Even cross-linking, consistent 90°C dielectric — Reliable insulation
Dosed ZC compound Flame-retardant PVC self-extinguishes to class C — Safety margin
Length-on-demand Cut to exact meter, sealed ends, minimal offcut — No waste
Batch resistance log Per-core DC R recorded against lot number — Traceable
Continuous print line Voltage, size, ZC, meter length along jacket — Clear ID
Phase-color option Insulation/jacket color matched to phase code — Fast wiring
Light & hand-pull 430 kg/km reel suits short branch pulls — Fast install
09 · Installation
Laying Tray, conduit, trunking, lighting branch — Power
Connectors Cu lugs, standard glands — General
Bend radius ≥ 15×OD ≈ 188 mm — Single-core
Parallel runs Derate when bundled in conduit/tray — Load
Site test Continuity + insulation post-laying — Commissioning
10 · Packing & Applications
Supply length Custom / wooden drum or coil m Light
Reel type Standard wooden drum / coil — Handy
Surface marking ZC-YJV, 1×35, 0.6/1kV, ZC, length — Marking
Typical use Lighting branch, socket ring, small power feed — Power


Cable Test Parameters


Test Parameters — ZC-YJV 1×35 LV Flame-Retardant Cable 
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance 20 °C, core 35 ≤0.524 Ω/km Routine
2 Voltage test (AC) 3.5 kV AC, 5 min No breakdown Routine
3 Insulation resistance XLPE, 20°C High & stable Routine
4 Continuity Core Continuous Routine
5 Flame retardancy Class C vertical test Self-extinguish Type
6 Sheath thickness Micrometer Nominal ≥1.4 mm Routine
7 Insulation thickness Micrometer Nominal ≥1.0 mm Routine
8 Dimensional check Caliper OD ≈ 12.5 mm Routine
9 Conductor construction Visual / strand count Class 2 compacted Routine
10 Short-circuit rating Calculated / type 3.1 kA / 1 s Type
11 Insulation eccentric test Cross-section measure Within tolerance Routine
12 Sheath appearance Visual Smooth, no flaw Routine
13 Printing legibility Visual Marking readable Routine
14 Mass per unit length Weigh / calculate ≈ 430 kg/km Routine


Cable Cross Section Structure


Polyolefin Single Core Earth Cable ZR-YJV 1 X 35mm2 Single Conductor 0.6/1kV Indoor Power

ZC-YJV 1×35 — Cross-Section Construction Diagram (Schematic)
Cu core / XLPE insulation / PVC ZC sheath · 0.6/1 kV · ZC class C flame retardant · ≈ 12.5 mm · lighting branch & socket ring
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor 1×35 compacted Cu, Class 2, ≈7 strands — ≈ 8 Power core
2 XLPE insulation Cross-linked PE ≈ 1.0 ≈ 10.5 90°C dielectric
3 PVC sheath ZC flame-retardant ≈ 1.4 ≈ 12.5 Protection
Key Dimensions & Properties (expanded)
Finished cable diameter ≈ 12.5 mm Single core
Approx. cable mass ≈ 430 kg/km Light Cu core
Nominal voltage rating 0.6/1 kV LV
Max voltage (Um) 1.2 kV Phase-earth
Normal conductor temp. 90 °C Continuous
Short-circuit temp. 250 °C Short time
Flame retardancy ZC class C, self-extinguishing — Not fire-rated
Min bending radius (fixed) ≥ 15 × OD ≈ 188 mm Single-core
DC resistance (35) ≤ 0.524 Ω/km Cu 35
Nominal current (35 core) ≈ 120 A Air, 30°C
Short-circuit rating (1s) ≈ 3.1 kA 35 Cu
Frequency 50 / 60 Hz General
Core configuration 1×35 — Single
Application Lighting, socket, small power — Power
Schematic — not to exact scale. OD ≈12.5 mm and weight ≈430 kg/km from cross-referenced industry samples. ZC-YJV 1×35 is a general LV flame-retardant power cable for lighting branches, socket rings and small power feeds; ZC class C self-extinguishes but is not 950°C fire-rated. Values marked (est.) require confirmation against the factory test certificate.


Cable Construction Description


Construction Description — ZC-YJV 1×35 LV flame-retardant power cable
Cu core / XLPE insulation / PVC ZC sheath · 0.6/1 kV · ZC class C · 90°C · ≈12.5 mm · lighting branch & socket ring
1. Product Identity & Ratings
ZC-YJV 1×35 rated 0.6/1 kV (Um 1.2), 90°C working, ZC class C flame retardant. OD ≈12.5 mm, ≈430 kg/km, ≈120 A, drum or coil.
2. Copper Conductor (1×35)
Single 35 mm² compacted Class 2 Cu core, ≈7 concentric strands; DC R ≤0.524 Ω/km @20°C; tinned optional.
3. XLPE Insulation
Cross-linked PE ≈1.0 mm gives a stable 90°C dielectric; short-circuit limit 250°C; phase color on request.
4. PVC ZC Sheath
Flame-retardant PVC ≈1.4 mm, self-extinguishing class C; warm graphite finish; indoor/tray use.
5. Factory Advantages
• Fine compacted round core, tight conduit.  • Stable XLPE cure.  • Dosed ZC self-extinguish.  • Cut to exact meter.  • Per-batch resistance log.  • Continuous clear print.  • Phase-color option.  • Light & hand-pull at 430 kg/km.
6. Site Handling Notes
• Bend 15×OD (≈188 mm).  • Cu lugs, standard glands.  • Derate in conduit.  • Indoor; UV grade if exposed.  • Continuity + insulation after laying.


8. Factory Advantages.

  • Fine compacted core — the small strand bundle lays round for a tight conduit fit.
  • Stable XLPE cure — even cross-linking keeps the 90°C dielectric consistent lot to lot.
  • Dosed ZC compound — flame-retardant PVC self-extinguishes to class C with a safety margin.
  • Length-on-demand — cut to the exact meter with sealed ends and minimal offcut.
  • Batch resistance log — per-core DC R recorded against the lot number for traceability.
  • Continuous print line — voltage, size, ZC, and meter length marked along the jacket.
  • Phase-color option — insulation or jacket color matched to the phase code for fast wiring.
  • Light & hand-pull — at 430 kg/km the reel suits short branch pulls with standard handling.

Polyolefin Single Core Earth Cable ZR-YJV 1 X 35mm2 Single Conductor 0.6/1kV Indoor Power


9. Packaging, Storage & Logistics. Standard wooden drum or coil; continuous marking (ZC-YJV, 1×35, 0.6/1kV, ZC, length). Store dry, indoor; avoid UV; light reels handle easily.


Polyolefin Single Core Earth Cable ZR-YJV 1 X 35mm2 Single Conductor 0.6/1kV Indoor Power


10. Procurement Specification. State "ZC-YJV 1×35", length, class C, and phase-color need; note it is flame retardant, not fire-rated; request the per-batch resistance log.


Polyolefin Single Core Earth Cable ZR-YJV 1 X 35mm2 Single Conductor 0.6/1kV Indoor Power



ZC-YJV 1×35 mm² Power Cable
Frequently Asked Questions (FAQ)
Flame-Retardant Class C · XLPE Insulated · PVC Sheathed · Copper Conductor · 0.6/1 kV

Product Basics

Q1. What does the model “ZC-YJV” mean?
“Z” stands for flame-retardant, “C” denotes Class C flame-retardant performance, “YJ” means XLPE (cross-linked polyethylene) insulation, and “V” means PVC sheath. ZC-YJV is a copper-core, Class C flame-retardant, XLPE-insulated, PVC-sheathed low-voltage power cable.
Q2. What does “1×35 mm²” indicate?
“1” means a single-core cable. “35 mm²” is the nominal cross-sectional area of the copper conductor. This size is commonly used for main power feeders, medium-sized motor circuits, and distribution board incoming lines in commercial and industrial installations.
Q3. What is the rated voltage?
The rated voltage U₀/U is 0.6/1 kV (0.6 kV phase-to-earth, 1 kV phase-to-phase), designed for low-voltage power transmission and distribution systems.
Q4. What materials are used in construction?
Conductor: plain copper, Class 2 stranded. Insulation: cross-linked polyethylene (XLPE). Outer sheath: flame-retardant PVC. Standard ZC-YJV is unarmored. For direct burial or locations requiring mechanical protection, armored variants such as ZC-YJV22 (double steel tape) or ZC-YJV32 (fine steel wire) are available.

Technical Specifications

Q5. What is the maximum operating temperature?
The maximum continuous conductor temperature is 90 °C. During short-circuit events, the conductor may reach up to 250 °C for no more than 5 seconds. XLPE insulation provides superior thermal and electrical performance compared with traditional PVC-insulated (VV) cables.
Q6. What is the typical current-carrying capacity?
For a 1×35 mm² copper XLPE cable, the ampacity is approximately 135–165 A when installed in free air at 30 °C ambient. Lower ratings apply when buried, grouped with other cables, or at elevated ambient temperatures. For precise engineering design, consult the manufacturer's ampacity tables (GB/T 16895 / IEC 60364) and apply appropriate derating factors.
Q7. What is the conductor DC resistance?
The maximum DC resistance of a 35 mm² Class 2 copper conductor at 20 °C is approximately 0.534 Φ/km (annealed copper), per GB/T 3956 / IEC 60228. The exact value should be verified against the factory test report for each production batch.

Installation & Applications

Q8. What is the minimum bending radius?
For single-core unarmored cables, the minimum bending radius is 15–20 times the cable outer diameter (15D–20D) during installation. Proper bending radius prevents insulation damage and ensures long-term reliability. D = actual outer diameter of the cable.
Q9. What are the typical applications?
Common uses include: main power feeders in commercial buildings; supply circuits for medium-sized motors, compressors, and large HVAC systems; distribution board incoming and outgoing feeders; and industrial plant power distribution where Class C flame-retardant performance is required by electrical codes.
Q10. Which standards and certifications apply?
Manufactured in accordance with GB/T 12706 (equivalent to IEC 60502), with conductor compliance to GB/T 3956 / IEC 60228 and flame-retardant testing per GB/T 18380 / IEC 60332-3. Common certifications include CCC (China), CE (Europe), ISO 9001, RoHS, and VDE/TUV for specific international markets.