0.6/1kV ZC-YJV 1x185mm² Stranded Copper Conductor XLPE Insulation PVC Outer Sheath Fire Resistant C Level
Technical Datasheet — ZC-YJV 0.6/1 kV 1×185 mm²
1. Cable Designation & Meaning
|
Code |
Meaning |
|---|---|
|
ZC |
Flame retardant, Class C (bundled combustion test) |
|
YJ |
XLPE (cross-linked polyethylene) insulation |
|
V |
PVC (polyvinyl chloride) outer sheath |
|
0.6/1 kV |
Rated voltage U₀/U = 600/1000 V; max. system voltage Uₘ = 1.2 kV |
|
1×185 mm² |
Single core, nominal copper conductor area 185 mm² |
|
Construction |
Unarmoured, non-screened, round cable |
2. Applicable Standards
- GB/T 12706.1-2020 (equivalent to IEC 60502-1) — Extruded insulation power cables ≤ 1 kV
- GB/T 3956 / IEC 60228 — Conductors
- GB/T 19666-2019 — Flame retardant & fire resistant cables
- GB/T 18380.3 — Bundled flame propagation test (Class C)

3. Product Components / Construction (inside → outside)
- Conductor — Bare annealed copper, Class 2 stranded compacted circular (37 wires typical; GB/T 3956 requires min. 30 wires for compacted round 185 mm²)
- Conductor screen — Not required for 0.6/1 kV Class 2; normally omitted
- Insulation — XLPE compound, extruded (black / red / blue etc. on request)
- Insulation thickness (nominal) — 1.6 mm (GB/T 12706 for 185–240 mm² at 0.6/1 kV)
- Filler / binder — Generally none for single-core; thin non-hygroscopic binder tape optional per factory process
- Outer sheath — Flame-retardant PVC compound (ZC grade)
- Sheath thickness (nominal) — 1.7 mm
- Sheath colour — Black (standard); red / yellow-green / blue / brown available
- Armour — None
- Metallic screen — None

4. Dimensional Data
|
Item |
Typical value |
Remarks |
|---|---|---|
|
Conductor nominal area |
185 mm² |
— |
|
Conductor construction |
Class 2 compacted stranded Cu, 37×∅2.50 mm (typical) |
|
|
Conductor diameter (approx.) |
16.5 mm |
|
|
Insulation nominal thickness |
1.6 mm |
|
|
Diameter over insulation (approx.) |
19.7 mm |
16.5 + 2×1.6 |
|
Sheath nominal thickness |
1.7 mm |
|
|
Overall cable diameter |
22.0 – 24.0 mm |
Typical ~23.9 mm; Nexans 22.0 mm, Libo 22.66 mm, Alfanar 23.2 mm, Class 5 24.0 mm |
|
Approx. weight |
1750 – 1944 kg/km |
1750 (Nexans), 1885 (structure table), 1944 (ZC-YJV62 sample) |
|
Cable shape |
Round |
— |

5. Insulation Data
- Material: XLPE (cross-linked polyethylene)
- Nominal thickness: 1.6 mm (GB/T 12706, 185–240 mm² class)
- Long-term service temperature rating: 90 °C
- Short-circuit temperature rating (≤5 s): 250 °C
- Emergency overload temperature: 105 °C (limited duration)
- Dielectric strength: Pass 3.5 kV AC / 5 min routine test; 4.0 kV type test
- Volume resistivity @90 °C: ≥ 10¹² Ω·cm (typical XLPE)
- Insulation resistance constant (R₀·L @90 °C): ≈ 3.67 MΩ·km
6. Electrical Parameters
|
Parameter |
Value |
Source / Note |
|---|---|---|
|
Rated voltage U₀/U |
0.6 / 1 kV |
Uₘ = 1.2 kV |
|
Test voltage AC (5 min) |
3.5 kV |
Routine test |
|
Type-test voltage |
4.0 kV |
IEC 60502 practice |
|
DC resistance @20 °C (Class 2 Cu) |
≤ 0.0991 Ω/km |
GB/T 3956 / IEC 60228 max |
|
AC resistance @90 °C (est.) |
≈ 0.126 Ω/km |
Copper temp. coefficient |
|
Recommended current rating — in air (30 °C, single circuit, single-core) |
≈ 530 A |
Common Chinese sample |
|
In air — flat spaced (IEC makers) |
510 – 661 A |
510 (Nexans), 533 (Nexans AE), 661 (Nexans flat) |
|
In air — trefoil |
335 – 510 A |
depends on formation |
|
Direct buried (20 °C, soil thermal res. 1.0 K·m/W, depth 0.7 m) |
≈ 480 A |
Common Chinese sample |
|
Buried/duct (20–30 °C) |
324 – 486 A |
324 (Nexans AE), 486 (Nexans CL) |
|
Short-circuit current capacity (1 s adiabatic, Cu, 250 °C) |
≈ 21.4 kA |
reference; ∝ cross-section |
|
Frequency |
50/60 Hz AC (DC usable) |
— |
7. Temperature Characteristics
- Max. conductor operating temperature (continuous): 90 °C
- Max. conductor temp. during short circuit (≤5 s): 250 °C
- Emergency overload temperature: 105 °C (limited duration, general XLPE practice)
- Min. ambient temperature during installation: 0 °C (below 0 °C requires pre-heating)
- Service ambient temperature range: −20 °C to +90 °C (sheath/environment)
- Flame retardant class: Category C, bundled flame test, self-extinguishing, limited flame spread per GB/T 19666
8. Mechanical & Installation Parameters
- Minimum bending radius (single-core unarmoured): ≥ 20 × overall diameter → ≈ 440–480 mm at Ø22–24 mm
- Maximum pulling tension (copper conductor only): 50 N/mm² × 185 mm² = 9250 N
- PVC sheath pulling limit: significantly lower — avoid direct sheath grip; use conductor pulling eye
- Direct burial: Allowed in non-aggressive soil without heavy impact; use sand bed + warning tape, deeper layout or conduit under roads
- Magnetic conduit warning (AC single-core): Must NOT be laid in magnetic steel pipe/conduit in AC circuits; use non-magnetic conduit or trefoil/flat arrangement to avoid eddy-current heating
- Elevation difference: No limitation for XLPE insulated cable.

9. Scope of Application / Usage Range
The ZC-YJV 0.6/1 kV 1×185 mm² cable is intended for fixed installation in low-voltage power distribution & transmission systems up to 1.2 kV system voltage, where basic flame-retardant (Class C) performance is required but fire-survival (fire-resistant) function is not mandated.
Typical applicable locations:
- Indoor power distribution rooms, switchboards, busbar risers in high-rise buildings
- Cable trays, cable ducts, cable trenches & shafts in commercial / residential buildings
- Fixed wiring in industrial plants, warehouses, light/medium machinery feeders
- Direct buried routes in non-aggressive soil with low mechanical impact
- Street lighting, PV inverter AC output / combiner circuits, EV fast-charger feeders (DC side requires polarity check)
- Metro/rail auxiliary power, stations, general civil engineering projects requiring ZC flame-retardant grade
Not suitable for:
- Heavy tensile / armour-protected routes → use YJV22 / ZC-YJV22
- Fire-survival emergency circuits → use NH-ZC-YJV
- Highly corrosive / hydrocarbon-rich environments without extra barrier
- Magnetic conduit AC single-core runs (eddy-current risk)
- Oil-filled / submerged without dedicated design.

Key engineering notes for this size
- Insulation thickness jumps at 185 mm² — it is 1.6 mm (the 120 mm² value of 1.2 mm does not apply here). This is a common design error to avoid.
- Current rating is formation-dependent — single-core 185 mm² in air ranges 510–661 A depending on flat/trefoil/spaced; always state laying method. For budget design, 530 A (air) / 480 A (buried) is conservative.
- Weight is ~1.9 t/km — plan drum handling and tray loading accordingly.
- DC resistance 0.0991 Ω/km is the hard compliance limit (GB/T 3956 Class 2); real cables typically 5–15 % below.