3+1 Core Flame Retardant 4 Cores Cable For Factory Three Phase Main Power

3+1 Core Flame Retardant 4 Cores Cable For Factory Three Phase Main Power

Basic Properties

country of origin
China
brand name
TD
certificate
CE/ISO/CCC
product model
ZR-YJV 3x16mm²+1x10mm²

Trading Properties

moq
100 meters
payment method
L/C,T/T
supply capacity
10000 meters per month

Product Summary

ZR-YJV 3+1 Core Flame Retardant Copper Cable 3x16mm²+1x10mm² for Factory Three-Phase Main Power Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC ...

Product Details

Highlight:

Three Phase 4 Cores Cable

,

4 Cores Cable 1.5mm sheath

,

10 sq mm copper cable 4 core

Phase conductor (×3):
Bare Annealed Copper, Class 2 Stranded, 7×∅1.70 Mm, Conductor Ø ≈ 5.1–5.5 Mm
Neutral conductor (×1):
Bare Annealed Copper, Class 2 Stranded, 7×∅1.35 Mm, Conductor Ø ≈ 4.1–4.5 Mm
Phase conductor nominal area:
16 Mm²
Neutral conductor nominal area:
10 Mm²
Number of cores:
4 (3+1)
Phase conductor construction:
Class 2, 7×∅1.70 Mm,IEC 60228 / GB/T 3956
Neutral conductor construction:
Class 2, 7×∅1.35 Mm,IEC 60228 / GB/T 3956
Phase conductor diameter (approx.):
5.1–5.5 Mm
Neutral conductor diameter (approx.):
4.1–4.5 Mm
Insulation (×4):
XLPE
Insulation thickness:
0.7 Mm (16 Mm² Class)
Diameter over phase insulated core:
6.5–6.9 Mm
Diameter over neutral insulated core:
5.5–5.9 Mm
Filler / binder:
FR PP Filler + FR Tape
Outer sheath:
Flame-retardant PVC (ZR Grade)
Sheath thickness:
1.5 Mm (GB/T 12706 Multi-core Small Section)
Overall cable diameter:
14.5 – 17.5 Mm
Design outer diameter:
≈ 16.0 Mm
Approx. weight:
320 – 420 Kg/km
Design weight:
≈ 360 Kg/km
Cable shape:
Round

Product Description

ZR-YJV 3+1 Core Flame Retardant Copper Cable 3x16mm²+1x10mm² for Factory Three-Phase Main Power

 

Cable Designation & Meaning

 

Code

Meaning

ZR

Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC).

YJ

XLPE (cross-linked polyethylene) insulation

V

PVC outer sheath — flame-retardant grade, contains halogen (Cl)

0.6/1 kV

Rated voltage U₀/U = 600/1000 V; Uₘ = 1.2 kV

3×16+1×10 mm²

Three phase cores of 16 mm² copper + one reduced neutral core of 10 mm² copper

 

3+1 Core Flame Retardant 4 Cores Cable  For Factory Three Phase Main Power

ZR-YJV 3×16+1×10 mm² — Cable Specification & Engineering Data

1. Overview & Ratings. ZR-YJV 3×16+1×10 — flame-retarding 3+1-core cable, three 16 mm² Cu phase conductors + one 10 mm² Cu neutral conductor, XLPE insulation, one ST2 PVC sheath, rated 0.6/1 kV (Um = 1.2 kV), 50 Hz; built and proof-tested per GB/T 12706.1 / IEC 60502-1, stranding per GB/T 3956, ZC fire class per GB/T 19666. ≈ 17.5 mm, ≈ 679 kg/km, 100 m coils/drums.

 

2. Construction Stack. Conductor → outer sheath:

Layer Build Wall Diameter
Conductor — phase (×3) Annealed Cu, Class 2, 7 × 1.70 mm (1+6) each — ≈ 5.10 mm
Conductor — neutral (×1) Annealed Cu, Class 2, 7 × 1.35 mm (1+6) — ≈ 4.05 mm
Insulation — phase (×3) XLPE 0.7 mm ≈ 6.50 mm
Insulation — neutral (×1) XLPE 0.7 mm ≈ 5.45 mm
Lay-up Neutral core at centre + 3 phase cores around + filler + binder tape — ≈ 14.5 mm (calc.)
Sheath Flame-retarded PVC, ST2, black 1.5 mm ≈ 17.5 mm (Zhongce 3+1)

 

3. Electrical Ratings. R ≤ 1.15 Ω/km (phase) / 1.83 Ω/km (neutral) @ 20 °C; routine 3.5 kV / 5 min; insulation resistance ≥ 36.7 MΩ·km; XLPE volume resistivity ≥ 1×10¹² Ω·cm; capacitance ≤ 0.45 μF/km. Reference ampacity (3 phase cores loaded) ≈ 90 A air @ 30 °C / 110 A buried @ 25 °C — Zhongce 3+1 unarmored table.

 

Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

Uₘ = 1.2 kV

Test voltage AC (5 min)

3.5 kV

Routine

Type-test voltage

4.0 kV

IEC 60502-1

DC resistance @20 °C (phase, per core)

≤ 1.15 Ω/km

GB/T 3956 max, 16 mm²

DC resistance @20 °C (neutral, per core)

≤ 1.83 Ω/km

GB/T 3956 max, 10 mm²

AC resistance @90 °C (est., phase)

≈ 1.50 Ω/km

per core

AC resistance @90 °C (est., neutral)

≈ 2.38 Ω/km

per core

Current rating in air (30 °C, single circuit, 3-core+1)

≈ 65–75 A

based on 16 mm² phase

Current rating in air (design)

≈ 70 A

apply grouping + ambient correction

Direct buried (20–25 °C, soil 1.0–1.2 K·m/W, 0.7 m)

≈ 75–88 A

common catalogue 78–84 A

Design buried rating

≈ 80 A

soil thermal resistivity correction required

Short-circuit current (1 s, Cu, 250 °C, phase)

≈ 1.6 kA

16 mm² reference

Short-circuit current (1 s, Cu, 250 °C, neutral)

≈ 1.0 kA

10 mm² reference

Frequency

50/60 Hz AC

—

 

4.Cable Parameters & Test Parameters

 

3+1 Core Flame Retardant 4 Cores Cable  For Factory Three Phase Main Power

 

ZR-YJV 3×16+1×10 mm² — Test / Verification Parameters (per GB/T 12706.1 & IEC 60502-1)
Stage Test Item Method / Standard Acceptance Criterion Notes
Routine Conductor DC resistance — phase GB/T 3956 (IEC 60228) ≤ 1.15 Ω/km @ 20 °C (16 mm²) Every production length
Routine Conductor DC resistance — neutral GB/T 3956 (IEC 60228) ≤ 1.83 Ω/km @ 20 °C (10 mm²) Every production length
Routine Power-frequency withstand voltage GB/T 12706.1 / IEC 60502-1 3.5 kV AC / 5 min, no breakdown Conductor-to-earth/water
Routine Construction check GB/T 2951 Phase ins. ≥ 0.7 mm; neutral ins. ≥ 0.7 mm; sheath ≥ 1.5 mm; OD within tolerance Thickness & diameter
Sample Hot set test — XLPE GB/T 12706.1 §16.3.13 / GB/T 2951.11 200 ± 3 °C, 15 min, 0.2 MPa: load elongation ≤ 175 %; permanent ≤ 15 % Cross-linking degree
Sample Conductor construction & diameter GB/T 3956 Phase: 7 × 1.70 mm Ø ≈ 5.10; neutral: 7 × 1.35 mm Ø ≈ 4.05 Per batch
Type Single-cable flame test GB/T 18380.12 No flame spread to top reference ZR property
Type Bunched flame test — class C GB/T 18380.35 Char ≤ 2.5 m; 20 min; ≥ 1.5 L/m ZC class
Type Bending test GB/T 12706.1 No damage on specified mandrel Multi-core rule
Post-install DC withstand test Q/GDW 13244.1-2018 2.4 kV DC / 15 min, no breakdown New installations
Optional Insulation resistance @ 20 °C Factory method ≥ 36.7 MΩ·km Not routine in GB/T 12706.1

 

5.Cable Cross Section Structure

 

3+1 Core Flame Retardant 4 Cores Cable  For Factory Three Phase Main Power

ZR-YJV 3×16+1×10 mm² — Cable Cross-Section Structure (Schematic)
3+1 core construction (3 phase + 1 neutral) from conductor to outer sheath · nominal values per GB/T 12706.1 / IEC 60502-1 · not to exact scale
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor — phase (Cu) × 3 Annealed copper, Class 2 stranded — 7 × 1.70 mm per core (7/1.70, 1+6), nominal 16 mm² per core — ≈ 5.10 (Ø per phase core) Current-carrying phase conductors; max DC resistance ≤ 1.15 Ω/km @ 20 °C
2 Conductor — neutral (Cu) × 1 Annealed copper, Class 2 stranded — 7 × 1.35 mm (7/1.35, 1+6), nominal 10 mm² — ≈ 4.05 (Ø neutral core) Neutral / return conductor; max DC resistance ≤ 1.83 Ω/km @ 20 °C
3 Insulation — phase (XLPE) × 3 Cross-linked polyethylene 0.7 ≈ 6.50 (Ø per phase core, over insulation) Dielectric barrier; rated 90 °C continuous; withstands 3.5 kV / 5 min
4 Insulation — neutral (XLPE) × 1 Cross-linked polyethylene 0.7 ≈ 5.45 (Ø neutral core, over insulation) Dielectric barrier for neutral core
5 Core lay-up Neutral core at centre + three phase cores around it + dry filler + binder tape — ≈ 14.5 (Ø over lay-up, calc.) 3+1 configuration; round bundle
6 Outer sheath (PVC) Flame-retardant PVC, ST2 type, black 1.5 ≈ 17.5 (Ø overall, Zhongce) Mechanical & moisture protection; flame retardance ZC (ZR) per GB/T 19666
Key Dimensions & Properties
Overall diameter ≈ 17.5 mm Zhongce 3+1 unarmored table    
Approx. cable weight ≈ 679 kg/km Zhongce 679 (Cu)    
Rated voltage 0.6/1 kV AC 50 Hz; max system voltage Um = 1.2 kV    
Max conductor temperature 90 / 250 °C Continuous / short-circuit (≤ 5 s)    
Min. bending radius (multi-core) ≥ 15 × OD — OD = actual cable diameter    
Flame-retardant class ZC (ZR) — GB/T 19666    
Schematic — not to exact scale. Nominal values for reference; confirm against factory test certificate.

 

3+1 Core Flame Retardant 4 Cores Cable  For Factory Three Phase Main Power

 

6. Thermal & Fire. 90 °C continuous, 250 °C short-circuit (≤ 5 s); −20~+45 °C ambient, ≥ 0 °C laying; ZC per GB/T 19666 — GB/T 18380.12 single-burn + GB/T 18380.35 class-C bunched (char ≤ 2.5 m); PVC is halogen-bearing → WDZ-YJY for LSZH.

 

Flame-Retardant (FR) Characteristics — ZR-YJV 3×16+1×10 mm²
ZR-YJV 3×16+1×10 mm²  (3 (L1+L2+L3, 16 mm²) + 1 (N, 10 mm²); 3+1 = L1+L2+L3+N)   ·   0.6/1 kV
1.  Cable Identification
Code / Item Meaning / Value Standard / Note
Designation ZR-YJV 3×16+1×10 mm² GB/T 12706.1-2020
ZR Flame Retardant (legacy); under GB/T 19666-2019 defaults to Class C; modern = ZC GB/T 19666-2019
YJ XLPE insulation (cross-linked polyethylene) —
V PVC outer sheath — flame-retardant, contains halogen (Cl) GB/T 19666-2019
0.6/1 kV U₀/U = 600/1000 V; Uₘ = 1.2 kV IEC 60502-1
3×16+1×10 mm² Three 16 mm² phase cores + one 10 mm² neutral core (reduced neutral, 3+1 construction) —
Construction Unarmoured, non-screened, round multi-core (3+1) —
Application note 3+1 core → three-phase AC with neutral (L1+L2+L3+N); neutral reduced to 10 mm². No separate PE (use 4-core or 5-core if PE required). —
2.  Flame-Retardant & Fire Performance  (CORE)
Property Value / Requirement Standard
Flame Retardant Class Class C (bundled cables, char length ≤ 2.5 m) GB/T 19666-2019; GB/T 18380.3 / IEC 60332-3-24
Legacy designation ZR (= ZC); modern prefix preferred: ZC GB/T 19666-2019
Test method — flame Bunched flame test (category C), char ≤ 2.5 m after flame removal GB/T 18380.3 (IEC 60332-3-24)
Halogen content Contains halogen — Cl from PVC sheath; releases HCl on burning GB/T 17650 / IEC 60754-1/-2
Smoke density Heavy dark smoke — NOT low-smoke (no LSZH certification) GB/T 17651 / IEC 61034
Corrosivity Corrosive — HCl gas generated during fire GB/T 17650 / IEC 60754-2
pH / conductivity of gases Not certified (PVC base — acidic / conductive combustion gases) GB/T 17650 / IEC 60754-2
Limited Oxygen Index (LOI) PVC typical ≈ 45–49 % O₂ (reference, design value) ASTM D2863 / GB/T 2406, reference
Max. conductor operating temp. 90 °C (long-term service) GB/T 12706.1-2020
Max. short-circuit temp. (≤5 s) 250 °C IEC 60502-1
Emergency overload temp. 105 °C (up to 130 °C transient) IEC 60502-1
Service ambient range (PVC sheath) −15 °C to +90 °C —
Min. installation ambient temp. 0 °C (pre-heat required below 0 °C) —
3.  Fire Test Summary
Test Requirement ZR-YJV 3×16+1×10 mm² Verdict
Bunched flame test (Class C) Char length ≤ 2.5 m PASS (design, Class C)
Single flame test (IEC 60332-1) Self-extinguishing PASS (XLPE/PVC FR)
Smoke density (IEC 61034) Light transmittance ≥ 60 % for LSZH N/A (PVC = heavy smoke)
Halogen content (IEC 60754) ≤ 0.5 % HCl for LSZH N/A (contains Cl)
Acidity / corrosivity (IEC 60754-2) pH ≥ 4.3; conductivity ≤ 10 µS/mm for LSZH N/A (corrosive HCl)
Fire-survival (BS 6387 / IEC 60331) Circuit integrity during/after fire N/A — use NH-ZR-YJV
4.  Key Electrical & Thermal Parameters
Parameter Value Note
Rated voltage U₀/U 0.6 / 1 kV Uₘ = 1.2 kV
Test voltage AC (5 min, routine) 3.5 kV IEC 60502-1
Type-test voltage 4.0 kV IEC 60502-1
DC resistance @ 20 °C (phase, 16 mm²) ≤ 1.15 Ω/km GB/T 3956 / IEC 60228, Class 2 max
DC resistance @ 20 °C (neutral, 6 mm²) ≤ 1.83 Ω/km GB/T 3956 / IEC 60228, Class 2 max
AC resistance @ 90 °C (phase, est.) ≈ 1.50 Ω/km per phase core
Current rating — in air (30 °C, single circuit) ≈ 62–68 A (design ≈ 65 A) 3+1 core
Current rating — direct buried (20 °C, soil 1.0 K·m/W, 0.7 m) ≈ 75–82 A (design ≈ 78 A) 3+1 core
Short-circuit current (1 s, Cu, 250 °C, per core) ≈ 1.6 kA (per phase core) phase core; neutral ≈ 1.0 kA
5.  Construction & Material Specification (with FR Contribution)
Layer (inside → out) Description / Specification FR Contribution
Conductor (phase ×3) Bare annealed copper, Class 2 stranded, 7ר1.70 mm, Ø ≈ 5.2 mm None (Cu non-combustible)
Conductor (neutral ×1) Bare annealed copper, Class 2 stranded, 7ר1.35 mm, Ø ≈ 4.3 mm None (Cu non-combustible)
Conductor screen Omitted (not required for 0.6/1 kV) —
Insulation (×4) XLPE (cross-linked polyethylene), 0.7 mm nominal; L1/L2/L3 = brown/black/grey, N = blue (all 0.7 mm class) XLPE — low flame spread
Filler Flame-retardant PP / PE to form round assembly FR additive
Binder Flame-retardant tape over laid-up cores FR barrier
Inner binder / assembly FR tape, no inner sheath required for plain YJV FR barrier
Outer sheath Flame-retardant PVC (ZR grade), 1.5 mm (multi-core, 3+1 rule), Black (standard) Primary FR layer (halogenated)
Armour None —
Metallic screen None —
6.  Dimensional Data
Item Typical Value Remarks
Conductor nominal area 3×16 mm² + 1×10 mm² phase / neutral
Number of cores 4 (3+1) —
Conductor construction Phase: Class 2, 7ר1.70 mm; Neutral: Class 2, 7ר1.70 mm min. 7 wires
Conductor diameter (approx.) Phase ≈ 5.2 mm; Neutral ≈ 4.3 mm —
Insulation thickness 0.7 mm (both 16 & 10 mm² class) 0.7 mm class
Diameter over insulated core Phase 6.6 mm; Neutral 5.7 mm conductor + 2×0.7
Sheath thickness 1.5 mm (multi-core, 3+1 rule) 3+1 multi-core rule
Overall cable diameter 13.0 – 16.0 mm (design ≈ 17.0 mm) design ≈ 17.0 mm
Approx. weight 360 – 480 kg/km (use ≈ 420 kg/km) —
Cable shape Round —
7.  Mechanical & Installation Parameters
Parameter Value Note
Minimum bending radius (unarmoured multi-core) ≥ 15 × OD ≈ 255 mm @ Ø≈ 17.0 mm —
Max. pulling tension (Cu only) 50 N/mm² × (3×16 + 1×10) = 2,900 N total use conductor sock, avoid sheath grip
Direct burial Allowed in non-aggressive soil; for mechanical protection use ZR-YJV22 3×16+1×10 —
Conduit ID ≥ 1.5 × OD → ≥ 26 mm (use 32 mm or 40 mm conduit) —
Fixing (horizontal / vertical tray) ≈ 800 mm / ≈ 1500 mm (horizontal / vertical tray) —
Elevation difference limit None (XLPE) —
8.  Selection Guide — When FR Matters
Scenario Recommended Cable Reason
Flame-retardant, halogenated acceptable (standard) ZR-YJV 3×16+1×10 mm² (this cable) Class C FR, PVC sheath, cost-effective
Low-smoke halogen-free required (LSZH) WDZ-YJY 3×16+1×10 LSZH sheath — IEC 61034 / IEC 60754 compliant
Fire-survival circuit (circuit integrity) NH-ZR-YJV / WDZN-YJY 3×16+1×10 BS 6387 / IEC 60331 fire-survival grade
1. ZR is the legacy GB/T 19666-2019 Class C designation; modern equivalent is ZC. Class C: char ≤ 2.5 m after bunched flame test (GB/T 18380.3).
2. PVC sheath is halogenated (contains Cl, releases HCl) → heavy smoke and corrosive gases; NOT suitable for LSZH-required routes (use WDZ-YJY).
3. 3×16+1×10 mm² = three 16 mm² phase cores (L1+L2+L3) + one 10 mm² neutral (N), total 4 cores (3+1); neutral is reduced in size. Current ratings (≈65 A air / ≈78 A buried) are design values; apply grouping, ambient temperature, soil thermal resistivity and IEC 60364-5-52 correction factors.
4. For LSZH → WDZ-YJY 3×16+1×10; for fire-survival → NH-ZR-YJV / WDZN-YJY 3×16+1×10; for armour → ZR-YJV22 3×16+1×10; for separate PE → use 5-core (e.g. 5×10).
5. DC resistance phase ≤ 1.15 Ω/km, neutral ≤ 1.83 Ω/km (GB/T 3956 Class 2 max). Test values marked “reference” are typical design values — confirm against manufacturer test report / GB/T 12706.1-2020.

 

7. Installation & Care. Bend ≥ 15 × OD; DC site test 4U0 = 2.4 kV / 15 min before energising (Q/GDW 13244.1-2018); pre-heat drums below 0 °C; de-rate 90/110 A for ambient, grouping, burial; lugs/glands for the 5.10 mm phase core, 4.05 mm neutral core and 17.5 mm sheath.

 

3+1 Core Flame Retardant 4 Cores Cable  For Factory Three Phase Main Power

 

8. Application. Three-phase four-wire distribution, building mains and light-to-medium industrial feeders where a dedicated neutral conductor is required in one cable (TN-C style) — conduit, tray, trench, duct, trunking; indoor or sheltered outdoor.

 

3+1 Core Flame Retardant 4 Cores Cable  For Factory Three Phase Main Power

 

9. Ordering. ZR-YJV 0.6/1 kV 3×16+1×10 + length/drum + marking; confirm against factory test certificate.

 