3x25mm2+1x16mm2 25 Sq Mm 4 Core Cable For Three Phase Retrofit Projects

3x25mm2+1x16mm2 25 Sq Mm 4 Core Cable For Three Phase Retrofit Projects

Basic Properties

country of origin
China
brand name
TD
certificate
CE/ISO/CCC
product model
ZR-YJV 3x25mm²+1x16mm²

Trading Properties

moq
100 meters
payment method
L/C,T/T
supply capacity
10000 meters per month

Product Summary

Flame Retardant 3+1 Core Copper Cable ZR-YJV 3x25mm²+1x16mm² for Three Phase Retrofit Projects Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 3×25 mm² + 1×16 mm² Three phase cores of 25 mm² + one ...

Product Details

Highlight:

Retrofit Projects xlpe cu cable

,

25 sq mm 4 Core Cable ISO

,

0.9mm 150 sq mm 4 core cable

Phase conductor (×3):
Bare Annealed Copper, Class 2 Stranded, 7×∅2.14 Mm, Conductor Ø ≈ 6.4–6.8 Mm
Neutral conductor (×1):
Bare Annealed Copper, Class 2 Stranded, 7×∅1.70 Mm, Conductor Ø ≈ 5.1–5.5 Mm
Phase conductor nominal area:
25 Mm²
Neutral conductor nominal area:
16 Mm²
Number of cores:
4 (3+1)
Phase conductor construction:
Class 2, 7×∅2.14 Mm,IEC 60228 / GB/T 3956
Neutral conductor construction:
Class 2, 7×∅1.70 Mm,IEC 60228 / GB/T 3956
Phase conductor diameter (approx.):
6.4–6.8 Mm
Neutral conductor diameter (approx.):
5.1–5.5 Mm
Insulation (×4):
XLPE
Phase insulation thickness:
0.9 Mm (25 Mm² Class)
Neutral insulation thickness:
0.7 Mm (16 Mm² Class)
Diameter over phase insulated core:
8.2–8.6 Mm
Diameter over neutral insulated core:
6.5–6.9 Mm
Filler / binder:
FR PP Filler + FR Tape
Outer sheath:
Flame-retardant PVC (ZR Grade)
Sheath thickness:
1.5 Mm (GB/T 12706 Multi-core 16–35 Mm² Range)
Overall cable diameter:
16.5 – 20.0 Mm
Design outer diameter:
≈ 18.0 Mm
Approx. weight:
430 – 560 Kg/km
Design weight:
≈ 480 Kg/km

Product Description

Flame Retardant 3+1 Core Copper Cable ZR-YJV 3x25mm²+1x16mm² for Three Phase Retrofit Projects

Cable Designation & Meaning

Code

Meaning

ZC

Flame retardant Class C 

YJ

Cross-linked polyethylene (XLPE) insulation 

V

Polyvinyl chloride (PVC) sheath 

3×25 mm² + 1×16 mm²

Three phase cores of 25 mm² + one neutral core of 16 mm² copper conductor


Construction: Three 25 mm² copper conductors (phase) + one 16 mm² copper conductor (neutral), XLPE insulation, PVC outer sheath. No metallic screen/armour as standard (can be added on request).


3x25mm2+1x16mm2 25 Sq Mm 4 Core Cable For Three Phase Retrofit Projects


ZC-YJV 3×25+1×16 mm² — LV Flame-Retardant 3+1 Power Cable — Specification

1. Overview & Ratings. ZC-YJV 3×25+1×16 is a compact 3+1 LV branch cable rated 0.6/1 kV (Um 1.2), 90 °C working, ZC class C PVC sheath: three 25 mm² compacted copper phase cores plus one reduced 16 mm² neutral, dry-cured XLPE, unarmored (screen optional). OD ≈ 12 mm, ≈ 760 kg/km (est.), ≈ 78 A per phase free air at 30 °C (est.). Scope: 380/400 V small motors, control-panel outgoing feeders and mixed power-lighting branches — not 950°C fire duty.


2. Construction Stack (Inner → Outer, expanded).


Layer / Feature Build Function
Phase conductors L1/L2/L3 3×25 compacted Cu, Class 2, ≈7 strands Phases, R ≤0.741 Ω/km
Neutral conductor N 1×16 compacted Cu, Class 2, ≈7 strands Reduced neutral, R ≤1.15 Ω/km
Strand compaction Concentric layers rolled compact per core Compact bundle, clean small lugs
XLPE insulation (phases) Dry-cured PE, ≈1.3 mm 90°C phase dielectric
XLPE insulation (neutral) Dry-cured PE, ≈1.2 mm Matched neutral dielectric
3+1 core laying 3 phases around 1 neutral Stable compact round bundle
PVC ZC sheath Class C, ≈1.2 mm overall Binds bundle, self-extinguishes
Jacket print Continuous type/size/voltage/length On-site readable spec


3. Electrical Characteristics. Phase R ≤ 0.741 Ω/km, neutral R ≤ 1.15 Ω/km @20 °C. Test 3.5 kV AC / 5 min; ≈ 78 A per phase (est., air 30 °C); short-circuit ≈ 2.4 kA / 1 s (est.); 50/60 Hz; unscreened; low-loss XLPE; high stable insulation resistance.

Insulation & Sheath Data

Property

Value

Insulation material

XLPE (cross-linked polyethylene)

Outer sheath material

PVC (ST₂)

Long-term service temp.

90 °C (continuous)

Max. conductor temp. (normal)

90 °C

Short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Test voltage AC (5 min)

3.5 kV

Dielectric strength

≥ 20 kV/mm

Volume resistivity @20 °C

≥ 1×10¹⁴ Ω·cm

Shield

None as standard (can be added)

Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

GB/T 12706.1 / IEC 60502-1

Max. system voltage

1.2 kV AC

—

Test voltage AC (5 min)

3.5 kV

Routine test

DC resistance @20 °C (phase)

≤ 0.727 Ω/km per core

GB/T 3956 Class 2 Cu max (25 mm²)

DC resistance @20 °C (neutral)

≤ 1.15 Ω/km per core

GB/T 3956 Class 2 Cu max (16 mm²)

AC resistance @90 °C (est., phase)

≈ 0.932 Ω/km per core

—

AC resistance @90 °C (est., neutral)

≈ 1.47 Ω/km per core

—

Current rating in air (30 °C)

3-phase: 105 A​

3×25+1×16, touching, in free air

Current rating in tray (30 °C)

3-phase: 115 A​

3×25+1×16, spaced 2×OD

Current rating buried in ground (20 °C, thermal resistivity 1.2 K·m/W)

3-phase: 110 A​

direct buried

Current rating in conduit (30 °C)

3-phase: 90 A​

—

Short-circuit current (1 s, Cu, 250 °C, phase)

≈ 2.8 kA (2,800 A) per core

—

Short-circuit current (1 s, Cu, 250 °C, neutral)

≈ 1.8 kA (1,800 A) per core

—

Capacitance (core-to-sheath, approx.)

≈ 0.15 µF/km

XLPE

Inductive reactance (approx.)

≈ 0.08 Ω/km

at 50 Hz

Frequency

50/60 Hz AC

—


Reference values: 3×25+1×16 at 105 A three-phase, 400 V → max load ≈ 63 kW​ (cos φ = 0.8). Suitable for small-to-medium three-phase distribution with reduced neutral, small motors, and light building feeders.


4. Thermal & Flame. 90 °C continuous, 250 °C short-time; ZC class C self-extinguishing — flame retardancy, not 950°C integrity; survives repeated start-switch cycles 0~90°C; indoor preferred, UV jacket optional.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

90 °C (continuous)

Max. short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Min. installation ambient temp.

0 °C (below 0 °C requires preheating)

Service ambient range

−20 °C to +90 °C

Flexing temp. range

0 °C to +90 °C

Fire Performance (ZC-YJV — Flame Retardant C)

Property

Value / Requirement

Flame retardant

GB/T 18380.12 / IEC 60332-1-2​ (single cable, self-extinguishing)

Flame retardant class

Class C​ (ZC) per GB/T 19666

Halogen content

Contains halogen (PVC sheath)

Smoke density

Not low-smoke (PVC)

Corrosivity

Corrosive (PVC)

Toxicity

Toxic fumes when burned (PVC)

EMI shielding

None (no metallic screen/armour)


5. Installation Practice & Handling. 25 mm² phase lugs, 16 mm² neutral lug, glands to ≈12 mm OD, small crimp/torque per table; bend ≥ 15×OD ≈ 180 mm; apply conduit/bundle derating; keep the 3+1 bundle tidy; verify three-phase continuity, sequence, neutral and insulation after pulling.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 15 × OD → ≈ 270 mm at Ø18.0 mm

four-core unarmoured

Max. pulling tension (phase)

375 N per core (25 mm² × 15 N/mm²)

Cu conductor limit

Max. pulling tension (neutral)

240 N per core (16 mm² × 15 N/mm²)

Cu conductor limit

Direct burial

Suitable (with sand bedding)

—

Surface mounting

Cable tray, ladder, cleats

—

Conduit ID

≥ 35 mm

—

Fixing

cable ties, cleats

—

Impact resistance

Moderate

—

Water resistance

Good (PVC sheath)

—

UV resistance

Fair (PVC degrades outdoors, use UV-resistant PVC or conduit)

—

Flex life

Good (Class 2 stranded)

fixed installation

Termination note

Standard compression lugs or mechanical connectors

—


6. Typical Service Applications. 380/400 V small three-phase motors, fans, pumps, control-panel outgoing feeders, cabinet-to-equipment links and mixed lighting-plus-power branches.


3x25mm2+1x16mm2 25 Sq Mm 4 Core Cable For Three Phase Retrofit Projects


7. Testing & QA Regime (16 items). Routine: phase DC resistance (25), neutral DC resistance (16), 3.5 kV withstand, insulation resistance, 3-phase+neutral continuity, phase/neutral insulation thickness, sheath thickness, dimensional check, strand construction, eccentricity, print legibility, mass, packing inspection. Type: ZC flame test, short-circuit rating, sheath mechanical.


Cable Parameters


ZC-YJV 3×25+1×16 mm² — LV Flame-Retardant 3+1 Power Cable — Full Parameter Sheet 
3×25 phase Cu + 1×16 neutral Cu · XLPE insulation / PVC sheath · ZC · 0.6/1 kV · ≈12 mm · 3+1 lay · 380/400 V small motor, control panel outgoing & mixed power-lighting branch
Parameter Value Unit Remarks / Standard
01 · Identification
Cable type ZC-YJV — Cu/XLPE/PVC, flame-retardant class C — ZC-YJV denotes a copper conductor with cross-linked polyethylene insulation and a PVC outer sheath; ZC marks a class C flame-retardant PVC compound that self-extinguishes after the ignition source is removed.
Rated voltage (U0/U) 0.6/1 kV 0.6 kV phase-to-earth (U0) and 1 kV phase-to-phase (U) rating defines a general low-voltage cable suited to 380/400 V small-motor and control-panel branch circuits.
Maximum operating voltage (Um) 1.2 kV The 1.2 kV maximum system voltage is the continuous upper phase-to-earth limit the XLPE insulation may withstand in normal service.
Core configuration 3×25 phase + 1×16 neutral (3+1) — Three 25 mm² compacted copper phase cores plus one 16 mm² compacted neutral core, laid in a compact 3+1 arrangement for small motors and control outgoing circuits.
Conductor material Compacted stranded annealed copper — Soft annealed copper strands are layer-compacted into round 25 mm² phase and 16 mm² neutral bundles for compact lug entry.
Insulation XLPE cross-linked polyethylene — Chemically cross-linked polyethylene bonds into a heat-resistant dielectric retaining properties at the 90 °C operating temperature.
Sheath PVC, flame-retardant class C (ZC) — An overall PVC jacket binds the compact 3+1 bundle and carries the class C flame-retardant formulation; deep slate steel blue finish.
Flame retardancy ZC class C (self-extinguishing, not fire-rated) — On removal of a flame the cable stops propagating fire; this is flame retardancy, not 950 °C/180 min circuit-integrity fire resistance.
Suitable for Small motor, control outgoing, mixed branch — Designed for fixed small three-phase motors, control-panel outgoing feeders and mixed power-plus-lighting branch circuits.
Application 380V small motor / control cabinet branch — Typically runs from a control cabinet or small distribution board to a small motor, fan, pump or mixed lighting-and-power load.
Application note Not for 950°C circuit-integrity fire duty — Do not substitute this ZC cable for a mineral-insulated or fire-resistant circuit; it cannot maintain live integrity under sustained fire.
02 · Conductors
Phase cores count / area 3 × 25 (L1/L2/L3) mm² Three 25 mm² phase conductors carrying the small three-phase motor or branch load current.
Neutral core count / area 1 × 16 (N) mm² One 16 mm² neutral conductor sized for the branch neutral return on predominantly balanced small loads.
Conductor type Compacted stranded Cu, Class 2 — Class 2 stranded compacted construction gives fixed-wiring conductors that round into stable small bundles for lug termination.
DC resistance (25 phase) @ 20°C ≤ 0.741 Ω/km Maximum permitted DC resistance of a 25 mm² copper phase conductor at 20 °C, applied to L1/L2/L3.
DC resistance (16 neutral) @ 20°C ≤ 1.15 Ω/km Maximum permitted DC resistance of the 16 mm² neutral conductor at 20 °C; higher than phases by design of the reduced neutral.
Stranding Layer-compacted concentric bundle — Concentric layers of strands are compacted radially per core to reduce gaps, tighten the bundle and present a clean round lug entry.
Strands (nom., est.) 25 ≈7; 16 ≈7 strands per core — Approximate compacted strand counts; exact count follows the conductor standard for each section.
Surface Bare copper; tinned optional — Bare copper suits most indoor use; optional tinned plating improves corrosion resistance in damp or chemically mild sites.
Core identification L1/L2/L3 phase colors + N neutral — Phase cores and the smaller neutral are color-coded so phase sequence and neutral match at the motor or cabinet terminal.
Neutral sizing logic Reduced neutral for balanced small loads — The 16 mm² neutral suits balanced three-phase small loads; enlarge the neutral where LED rectifier or VFD harmonics are high.
Compaction benefit Compact round bundle, tidy OD, clean crimp — Radial compaction reduces overall diameter versus loose stranding and gives a flat, even lug crimp on both sections.
03 · Insulation
Insulation material XLPE (cross-linked polyethylene) — Cross-linked PE delivers a higher continuous temperature rating and lower dielectric loss than PVC insulation for the same size.
Insulation thickness (25 phase, nom.) ≈ 1.3 mm Nominal radial insulation wall on each 25 mm² phase core; gauged to withstand the 3.5 kV routine test.
Insulation thickness (16 neutral, nom.) ≈ 1.2 mm Nominal insulation wall on the smaller 16 mm² neutral core, matched to its voltage class.
Working conductor temp. 90 °C Maximum continuous conductor temperature under rated current without shortening insulation life.
Short-circuit temp. 250 °C Peak conductor temperature the insulation may survive for a short fault duration (seconds) before damage occurs.
Insulation resistance High and stable MΩ·km XLPE keeps a high, stable insulation resistance over life, supporting reliable earth-fault detection on small branch feeders.
Color L1/L2/L3/N color on request — Insulation colors are matched to local 3-phase convention or supplied natural with printed marking.
Cure type Chemical / dry-cured XLPE — A controlled cross-linking cure locks the polymer network so the insulation stays elastic rather than melting under heat.
04 · Sheath & Flame Retardancy
Sheath material PVC, flame-retardant ZC — The class C PVC outer jacket blends a flame-suppressing formulation while keeping a smooth, printable surface.
Sheath thickness (nom.) ≈ 1.2 mm Nominal overall jacket wall sized to shield the compact 3+1 bundle from abrasion and mechanical handling.
Finished outer diameter ≈ 12 mm Compact overall 3+1 finished diameter used to size glands, trunking and small conduit on branch runs.
Flame behavior Self-extinguishing, class C — After the test flame is removed the sample extinguishes without propagating; it is not 950°C fire-rated.
Sheath color Deep slate steel blue (black/gray on request) — Standard deep slate steel blue; black or dark gray jackets are supplied for industrial aesthetics on request.
Surface finish Smooth, continuous print — A smooth jacket carries a continuous printed line of type, size, voltage, ZC class and meter length along its length.
05 · Electrical
Rated voltage (U0/U) 0.6/1 kV Low-voltage rating matching 380/400 V small-motor and control branch systems.
Max voltage (Um) 1.2 kV Continuous upper system voltage for phase-to-earth insulation stress.
Nominal current (per 25 phase, est.) ≈ 78 A Approximate ampacity of a 25 mm² phase core in free air at 30 °C; reduce for conduit fill and high ambient.
Test voltage (AC) 3.5 kV / 5 min — Routine dielectric withstand applied between each conductor and sheath for five minutes without breakdown.
Insulation resistance High, XLPE MΩ·km Measured after conditioning; confirms no void, crack or contamination in the cured insulation.
Short-circuit current (25 phase, 1s, est.) ≈ 2.4 kA Approximate 1-second copper short-time withstand on the 25 mm² phase core; small branch fault coordination.
Frequency 50 / 60 Hz Compatible with both 50 Hz and 60 Hz three-phase power systems.
Dielectric XLPE, low loss — Low dielectric loss keeps heating down under continuous small motor and branch duty.
06 · Thermal & Environment
Normal conductor temp. 90 °C Sustained operating temperature the XLPE insulation is rated for under full load.
Installed ambient 0 ~ +40 °C Recommended continuous ambient around the cable; crowded control cabinets and small ducts require ampacity derating.
Min install temp. 0 °C Avoid cold bending below 0 °C where the PVC jacket and insulation may stiffen and crack.
Burning Self-extinguishing, ZC class C — Class C vertical flame test behavior: flame stops once the external burner is removed.
Outdoor / UV Indoor preferred; UV-grade jacket optional — Standard PVC degrades under prolonged direct sun; specify UV-stabilized jacket for exposed outdoor small runs.
Oil / chemicals Resistant to common oils; check aggressive media — Withstands typical machine oils; verify against specific solvents, cleaning agents or acid fumes before use.
Temperature cycle Withstands repeated 0~90°C duty — The insulation and jacket survive repeated motor start-stop and branch switching cycles without cracking.
07 · Mechanical & Construction
Min bending radius (fixed) ≥ 15 × OD ≈ 180 mm Fixed-installation minimum bend radius for the compact 3+1 cable; suitable for tight cabinet routing.
Flexibility Stranded, flexible for cabinet and conduit — Compact strands remain flexible enough for panel-to-equipment routing and small-bend conduit runs.
Shielding / Armor None / unarmored (screen optional) — No braid screen and no armor as standard; add braid screen near control EMI; armor rarely needed for this small section.
Cable weight per km (est.) ≈ 760 kg/km Light compact mass per kilometer used for cabinet fill and small drum sizing.
Circularity Compact 3+1 bundle, small OD — Three phases around the reduced neutral form a compact round bundle after sheathing.
Tensile / elongation Jacket meets PVC grade — Jacket tensile strength and elongation satisfy the PVC compound grade for routine pulling.
08 · Factory Advantages
Compact balanced 3+1 sizing 3×25 phases with 1×16 neutral for small loads — Right-sized reduced neutral avoids excess copper cost on balanced small three-phase branches.
Stable XLPE cure Even cross-linking keeps the 90°C dielectric consistent — Controlled cure prevents soft spots in the thin insulation under repeated switching cycles.
Dosed ZC compound Flame-retardant PVC self-extinguishes to class C — Self-extinguishing jacket protects control cabinets and small distribution wiring spaces.
Length-on-demand Cut to exact cabinet/machine meter, sealed ends — Custom cut lengths match the measured control outgoing and small branch route.
Dual-section resistance log Phase 25 and neutral 16 R logged to lot — Both conductor sections are recorded for incoming inspection and batch traceability.
Continuous print line Type, size, ZC, voltage and length along jacket — Clear continuous marking lets installers read phase and neutral section along short flexible branch runs.
Phase-color option L1/L2/L3/N insulation colors matched to convention — Pre-colored cores reduce wiring errors at cabinet terminal blocks and motor boxes.
Lightweight drum pack Small reel or short-length coil option — Compact mass supports small reels or short coiled lengths for site handling.
Certified QA pack Routine + type test record shipped per batch — A complete QA packet supports buyer inspection and control-circuit commissioning sign-off.
09 · Installation
Laying Control outgoing, small motor, mixed branch — Route in control cabinets, trays, small conduit or direct to equipment; keep the 3+1 bundle tidy and observe bend radius.
Connectors 25 mm² phase lugs; 16 mm² neutral lug — Crimp 25 mm² lugs on L1/L2/L3 and a 16 mm² lug on N; select small glands sized to ≈12 mm OD.
Bend radius ≥ 15×OD ≈ 180 mm — Maintain the minimum radius around cabinet entries and conduit elbows to avoid insulation stress.
Parallel runs Derating in bundles and small ducts — Adjacent loaded cores share heat; apply derating factors before selecting the small branch breaker.
Site test Continuity + insulation post-laying — After pulling, verify three-phase continuity, phase sequence, neutral continuity and insulation resistance.
Termination Strip, small hydraulic/hand crimp, torque — Strip insulation without nicking strands, use matched small dies on each lug, and torque per the lug table.
10 · Packing & Applications
Supply length Custom / small drum or coil m Cut to the measured small branch length on a small drum or coil.
Length tolerance Per trade standard for cut lengths — Cut-length tolerance follows the applicable trade standard rather than a fixed meter promise.
Reel type Small wooden reel / coiled length — Light section wound on a small reel or sealed coil; ends sealed against moisture.
Surface marking ZC-YJV, 3×25+1×16, 0.6/1kV, ZC, length — Jacket prints type, phase/neutral section, voltage, flame class and cumulative meter length.
Typical use Small motor, fan, pump, control outgoing, mixed branch — Small three-phase motors, fans, pumps, control-panel feeders and mixed lighting-power branches.
Storage Dry indoor on reel supports, avoid UV — Store horizontally on timber supports, dry and shaded; keep ends sealed until installation.


Cable Test Parameters


Test Parameters — ZC-YJV 3×25+1×16 LV Flame-Retardant 3+1 Cable
No. Test Item Test Condition / Method Requirement Type
1 DC resistance (25 phase) 20 °C, L1/L2/L3 (25 mm²) ≤0.741 Ω/km Routine
2 DC resistance (16 neutral) 20 °C, N (16 mm²) ≤1.15 Ω/km Routine
3 Voltage test (AC) 3.5 kV AC, 5 min, core-to-sheath No breakdown Routine
4 Insulation resistance XLPE, 20°C, per core High & stable Routine
5 Continuity 3 phases + neutral Continuous Routine
6 Flame retardancy Class C vertical test Self-extinguish Type
7 Sheath thickness Micrometer, cross-section Nominal ≈1.2 mm Routine
8 Phase insulation thickness Micrometer, 25 mm² cores Nominal ≈1.3 mm Routine
9 Neutral insulation thickness Micrometer, 16 mm² core Nominal ≈1.2 mm Routine
10 Dimensional check Caliper, overall OD OD ≈ 12 mm Routine
11 Conductor construction Visual / strand count per core Class 2 compacted Routine
12 Short-circuit rating Calculated / type ≈2.4 kA / 1 s Type
13 Insulation eccentric test Cross-section measure per core Within tolerance Routine
14 Printing legibility Visual Marking readable Routine
15 Mass per unit length Weigh / calculate ≈ 760 kg/km Routine
16 Packing & reel inspection Visual / reel and sealed ends Sealed ends, sound reel Routine


Cable Cross Section Structure

3x25mm2+1x16mm2 25 Sq Mm 4 Core Cable For Three Phase Retrofit Projects


ZC-YJV 3×25+1×16 — 3+1 Cross-Section Construction Diagram 
3×25 phase Cu + 1×16 neutral Cu / XLPE insulation / PVC ZC sheath · 0.6/1 kV · ZC class C · ≈12 mm · small motor, control outgoing & mixed branch
No. Layer / Feature Material / Construction Nominal Thickness (mm) Diameter (mm) Detailed Function / Remarks
1 Conductor L1 — phase 1×25 compacted Cu, Class 2, ≈7 strands — ≈ 5.6 Phase 1 core, DC R ≤0.741 Ω/km @20°C; small motor current.
2 Conductor L2 — phase 1×25 compacted Cu, Class 2, ≈7 strands — ≈ 5.6 Phase 2 core, equal size/resistance for balanced three-phase.
3 Conductor L3 — phase 1×25 compacted Cu, Class 2, ≈7 strands — ≈ 5.6 Phase 3 core, equal spec; color-coded for phase sequence.
4 Conductor N — neutral 1×16 compacted Cu, Class 2, ≈7 strands — ≈ 4.5 Reduced neutral, R ≤1.15 Ω/km; balanced small-load neutral return.
5 Strand compaction Concentric layers rolled compact per core — — Radial compaction closes gaps for a compact round bundle and clean lugs.
6 XLPE insulation (25 phase) Dry-cured cross-linked PE, ≈1.3 mm ≈ 1.3 ≈ 8.2 90°C phase dielectric; low loss, passes 3.5 kV routine test.
7 XLPE insulation (16 neutral) Dry-cured cross-linked PE, ≈1.2 mm ≈ 1.2 ≈ 6.9 Neutral dielectric matched to the smaller 16 mm² section.
8 3+1 core laying 3 phases around 1 reduced neutral — — Compact 3+1 arrangement settles into a small round finished form.
9 PVC ZC sheath Class C jacket, ≈1.2 mm ≈ 1.2 ≈ 12 Binds the compact bundle; self-extinguishes to class C; steel-blue finish.
10 Jacket print Continuous type/size/voltage/length line — — Marking: ZC-YJV, 3×25+1×16, 0.6/1kV, ZC, cumulative length.
Key Dimensions, Electrical & Mechanical Properties (expanded)
Finished cable diameter ≈ 12 mm Compact 3+1 branch OD for small glands and conduit.
Approx. cable mass (est.) ≈ 760 kg/km Light compact mass; small reel or coil.
Nominal voltage rating 0.6/1 kV Matches 380/400 V small-motor systems.
Max voltage (Um) 1.2 kV Phase-to-earth continuous upper limit.
Normal conductor temp. 90 °C Continuous load temperature of XLPE.
Short-circuit temp. 250 °C Short-time fault peak before insulation damage.
DC resistance (25 phase) ≤ 0.741 Ω/km Per phase core @20°C.
DC resistance (16 neutral) ≤ 1.15 Ω/km Reduced neutral @20°C.
Neutral sizing 1×16 reduced neutral — For balanced small loads; enlarge on high harmonics.
Nominal phase current (est.) ≈ 78 A Per 25 phase core, free air 30°C; derate in conduit.
Short-circuit rating (1s, est.) ≈ 2.4 kA Small branch fault coordination.
Flame retardancy ZC class C, self-extinguishing — Not 950°C fire-rated.
Min bending radius (fixed) ≥ 15 × OD ≈ 180 mm Cabinet and small-conduit bend radius.
Frequency 50 / 60 Hz Compatible with both power systems.
Insulation resistance High & stable MΩ·km XLPE; supports earth-fault detection.
Dielectric loss Low — XLPE limits heating on small branch duty.
Temperature cycle 0~90°C repeated — Survives switching and start-stop cycling.
Sheath mechanical Jacket meets PVC grade — Tensile/elongation checked at type test.
Pack choice Small reel / coiled length — Light section with sealed cable ends.
Application Small motor, control outgoing, mixed branch — 380/400 V fans, pumps, cabinets and mixed branches.
Schematic — not to exact scale. OD ≈12 mm, weight ≈760 kg/km, phase ampacity ≈78 A free air at 30°C and ≈2.4 kA/1s are (est.) from cross-referenced industry samples. ZC-YJV 3×25+1×16 serves 380/400 V small motors, control-panel outgoing feeders and mixed branches; ZC class C self-extinguishes but is not 950°C fire-rated. Estimated values require confirmation against the factory test certificate for the specific batch.


Cable Construction Description


Construction Description — ZC-YJV 3×25+1×16 LV flame-retardant 3+1 cable
3×25 phase Cu + 1×16 neutral Cu / XLPE insulation / PVC ZC sheath · 0.6/1 kV · ZC class C · 90°C · ≈12 mm · small motor, control outgoing & mixed branch
1. Product Identity & Ratings
ZC-YJV 3×25+1×16 rated 0.6/1 kV (Um 1.2), 90°C working, ZC class C; three 25 mm² phase cores plus one 16 mm² neutral in a compact 3+1 lay. OD ≈12 mm, ≈760 kg/km (est.), ≈78 A per phase free air at 30°C (est.), small reel or coil. It is a fixed small branch cable, not a flexible cord and not a 950°C fire-rated circuit.
2. Copper Conductors (3×25 phase + 1×16 neutral)
Three compacted Class 2 Cu phase cores (L1/L2/L3), R ≤0.741 Ω/km @20°C, plus one 16 mm² neutral, R ≤1.15 Ω/km @20°C; reduced neutral suits balanced small loads; tinned plating optional; phase-color insulation on request.
3. Strand Compaction & 3+1 Bundle
Concentric strands are rolled compact per core to close gaps and give clean small-lug entry; three phases surround the reduced neutral to form a compact round 3+1 bundle before sheathing.
4. XLPE Insulation
Dry-cured cross-linked PE ≈1.3 mm on phases and ≈1.2 mm on the neutral; stable 90°C dielectric, low dielectric loss, high insulation resistance; short-circuit peak 250°C; matched wall per section.
5. Core Identification
L1/L2/L3 phases and the N neutral are identified by insulation color; the smaller neutral section also distinguishes it visually at the cabinet terminal block or motor box.
6. PVC ZC Sheath
Class C flame-retardant PVC ≈1.2 mm overall, self-extinguishing; deep slate steel blue standard (black/gray on request); smooth printable surface; binds the compact bundle and shields from cabinet abrasion.
7. Electrical Characteristics
0.6/1 kV, Um 1.2; phase R ≤0.741, neutral R ≤1.15 Ω/km; routine 3.5 kV AC/5 min; ≈78 A per phase (est., air 30°C); short-circuit ≈2.4 kA/1s (est.); 50/60 Hz; unscreened; low-loss XLPE.
8. Factory Advantages
• Compact balanced 3+1 sizing.  • Stable XLPE cure.  • Dosed ZC self-extinguish.  • Length-on-demand.  • Dual-section resistance log.  • Continuous clear print.  • Phase-color option.  • Lightweight reel pack.  • Certified QA pack.
9. Site Handling & Installation
• Bend 15×OD (≈180 mm).  • 25 mm² phase lugs, 16 mm² neutral lug, glands to ≈12 mm OD, small crimp, torque per table.  • Conduit/bundle derating.  • Keep 3+1 bundle tidy.  • Three-phase continuity, sequence, neutral + insulation after pulling.
10. Typical Service Applications
380/400 V small three-phase motors, fans, pumps, control-panel outgoing feeders, cabinet-to-equipment links and mixed lighting-plus-power branch circuits.
11. Testing & QA
16-item regime: routine phase DC resistance (25), neutral DC resistance (16), 3.5 kV withstand, insulation resistance, 3-phase+neutral continuity, phase/neutral insulation thickness, sheath thickness, dimensional check, strand construction, eccentricity, print legibility, mass, packing inspection; type ZC flame, short-circuit, sheath mechanical.
12. Packaging, Storage & Notes
Cut to measured branch length on a small reel or coil with sealed ends; continuous marking; store dry indoor on reel supports, shaded, avoid direct UV. Est. OD/weight/ampacity/short-circuit confirmed against the factory certificate; ZC is flame retardant, not 950°C fire-rated.


8. Factory Advantages.

  • Compact balanced 3+1 sizing — 3×25 phases with 1×16 neutral, cost-effective on balanced small loads.
  • Stable XLPE cure — even cross-linking keeps the 90°C dielectric consistent under switching cycles.
  • Dosed ZC compound — self-extinguishing jacket protects cabinets and wiring spaces.
  • Length-on-demand — cut to exact cabinet/machine meter with sealed ends.
  • Dual-section resistance log — phase 25 and neutral 16 R logged to lot.
  • Continuous print line — type, size, ZC, voltage and length along jacket.
  • Phase-color option — L1/L2/L3/N colors matched to convention, fewer wiring errors.
  • Lightweight reel pack — small reel or short coiled length for site handling.
  • Certified QA pack — routine + type test record shipped per batch.

3x25mm2+1x16mm2 25 Sq Mm 4 Core Cable For Three Phase Retrofit Projects


9. Packaging, Storage & Logistics. Cut to measured branch length on a small reel or coiled length with sealed ends; continuous marking; store dry indoor on reel supports, shaded, avoid direct UV.

3x25mm2+1x16mm2 25 Sq Mm 4 Core Cable For Three Phase Retrofit Projects


10. Procurement Specification. State "ZC-YJV 3×25+1×16", length, class C, phase colors, braid screen near EMI if required; note reduced neutral for balanced small loads and not fire-rated; request dual-section resistance log and the 16-item QA record. Est. values confirmed against the factory certificate.


11. Cable Industry FAQ.

  • Q1: How does 3×25+1×16 differ from 3×50+1×25? Next size down: phases 25 vs 50 mm², neutral 16 vs 25 mm²; slimmer OD (12 vs 16 mm), lighter (760 vs 1450 kg/km), lower current (78 vs 120 A), higher resistance (0.741/1.15 vs 0.387/0.741 Ω/km); serves small control branches rather than main motor feeds.
  • Q2: Why a reduced 16 mm² neutral? Balanced small three-phase loads draw little neutral current, so a 16 mm² neutral saves copper; enlarge it under LED/VFD harmonic-heavy duty.
  • Q3: Is ZC fire-resistant? No. Class C self-extinguishes; it does not hold live at 950°C/180min.
  • Q4: DC resistance values? Phase 25 ≤0.741 Ω/km; neutral 16 ≤1.15 Ω/km at 20°C.
  • Q5: Screen or armor? Unscreened standard; add braid screen near control EMI; armor unnecessary at this small section.
  • Q6: Current per phase? ≈ 78 A (est.) free air 30°C; derate in conduit and crowded cabinets.
  • Q7: Bending? ≥ 180 mm (15×OD); fits tight cabinet routing.
  • Q8: Connectors? 25 mm² phase lugs, 16 mm² neutral lug, gland to ≈12 mm OD.
  • Q9: Indoor or outdoor? Indoor preferred; specify UV-stabilized jacket for exposed short runs.
  • Q10: Packing? Small reel or sealed coiled length.
  • Q11: What proof ships? Dual-section resistance log + 16-test record; est. values confirmed against certificate.