3x25mm2+1x16mm2 25 Sq Mm 4 Core Cable For Three Phase Retrofit Projects
Product Summary
Product Details
Retrofit Projects xlpe cu cable
,25 sq mm 4 Core Cable ISO
,0.9mm 150 sq mm 4 core cable
Product Description
Flame Retardant 3+1 Core Copper Cable ZR-YJV 3x25mm²+1x16mm² for Three Phase Retrofit Projects
Cable Designation & Meaning
|
Code |
Meaning |
|---|---|
|
ZC |
Flame retardant Class C |
|
YJ |
Cross-linked polyethylene (XLPE) insulation |
|
V |
Polyvinyl chloride (PVC) sheath |
|
3×25 mm² + 1×16 mm² |
Three phase cores of 25 mm² + one neutral core of 16 mm² copper conductor |
Construction: Three 25 mm² copper conductors (phase) + one 16 mm² copper conductor (neutral), XLPE insulation, PVC outer sheath. No metallic screen/armour as standard (can be added on request).

ZC-YJV 3×25+1×16 mm² — LV Flame-Retardant 3+1 Power Cable — Specification
1. Overview & Ratings. ZC-YJV 3×25+1×16 is a compact 3+1 LV branch cable rated 0.6/1 kV (Um 1.2), 90 °C working, ZC class C PVC sheath: three 25 mm² compacted copper phase cores plus one reduced 16 mm² neutral, dry-cured XLPE, unarmored (screen optional). OD ≈ 12 mm, ≈ 760 kg/km (est.), ≈ 78 A per phase free air at 30 °C (est.). Scope: 380/400 V small motors, control-panel outgoing feeders and mixed power-lighting branches — not 950°C fire duty.
2. Construction Stack (Inner → Outer, expanded).
| Layer / Feature | Build | Function |
|---|---|---|
| Phase conductors L1/L2/L3 | 3×25 compacted Cu, Class 2, ≈7 strands | Phases, R ≤0.741 Ω/km |
| Neutral conductor N | 1×16 compacted Cu, Class 2, ≈7 strands | Reduced neutral, R ≤1.15 Ω/km |
| Strand compaction | Concentric layers rolled compact per core | Compact bundle, clean small lugs |
| XLPE insulation (phases) | Dry-cured PE, ≈1.3 mm | 90°C phase dielectric |
| XLPE insulation (neutral) | Dry-cured PE, ≈1.2 mm | Matched neutral dielectric |
| 3+1 core laying | 3 phases around 1 neutral | Stable compact round bundle |
| PVC ZC sheath | Class C, ≈1.2 mm overall | Binds bundle, self-extinguishes |
| Jacket print | Continuous type/size/voltage/length | On-site readable spec |
3. Electrical Characteristics. Phase R ≤ 0.741 Ω/km, neutral R ≤ 1.15 Ω/km @20 °C. Test 3.5 kV AC / 5 min; ≈ 78 A per phase (est., air 30 °C); short-circuit ≈ 2.4 kA / 1 s (est.); 50/60 Hz; unscreened; low-loss XLPE; high stable insulation resistance.
Insulation & Sheath Data
|
Property |
Value |
|---|---|
|
Insulation material |
XLPE (cross-linked polyethylene) |
|
Outer sheath material |
PVC (ST₂) |
|
Long-term service temp. |
90 °C (continuous) |
|
Max. conductor temp. (normal) |
90 °C |
|
Short-circuit temp. (≤5 s) |
250 °C |
|
Emergency overload temp. |
130 °C (≤1 h) |
|
Test voltage AC (5 min) |
3.5 kV |
|
Dielectric strength |
≥ 20 kV/mm |
|
Volume resistivity @20 °C |
≥ 1×10¹⁴ Ω·cm |
|
Shield |
None as standard (can be added) |
Electrical Parameters
|
Parameter |
Value |
Note |
|---|---|---|
|
Rated voltage U₀/U |
0.6 / 1 kV |
GB/T 12706.1 / IEC 60502-1 |
|
Max. system voltage |
1.2 kV AC |
— |
|
Test voltage AC (5 min) |
3.5 kV |
Routine test |
|
DC resistance @20 °C (phase) |
≤ 0.727 Ω/km per core |
GB/T 3956 Class 2 Cu max (25 mm²) |
|
DC resistance @20 °C (neutral) |
≤ 1.15 Ω/km per core |
GB/T 3956 Class 2 Cu max (16 mm²) |
|
AC resistance @90 °C (est., phase) |
≈ 0.932 Ω/km per core |
— |
|
AC resistance @90 °C (est., neutral) |
≈ 1.47 Ω/km per core |
— |
|
Current rating in air (30 °C) |
3-phase: 105 A |
3×25+1×16, touching, in free air |
|
Current rating in tray (30 °C) |
3-phase: 115 A |
3×25+1×16, spaced 2×OD |
|
Current rating buried in ground (20 °C, thermal resistivity 1.2 K·m/W) |
3-phase: 110 A |
direct buried |
|
Current rating in conduit (30 °C) |
3-phase: 90 A |
— |
|
Short-circuit current (1 s, Cu, 250 °C, phase) |
≈ 2.8 kA (2,800 A) per core |
— |
|
Short-circuit current (1 s, Cu, 250 °C, neutral) |
≈ 1.8 kA (1,800 A) per core |
— |
|
Capacitance (core-to-sheath, approx.) |
≈ 0.15 µF/km |
XLPE |
|
Inductive reactance (approx.) |
≈ 0.08 Ω/km |
at 50 Hz |
|
Frequency |
50/60 Hz AC |
— |
Reference values: 3×25+1×16 at 105 A three-phase, 400 V → max load ≈ 63 kW (cos φ = 0.8). Suitable for small-to-medium three-phase distribution with reduced neutral, small motors, and light building feeders.
4. Thermal & Flame. 90 °C continuous, 250 °C short-time; ZC class C self-extinguishing — flame retardancy, not 950°C integrity; survives repeated start-switch cycles 0~90°C; indoor preferred, UV jacket optional.
Temperature Characteristics
|
Property |
Value |
|---|---|
|
Max. conductor operating temp. |
90 °C (continuous) |
|
Max. short-circuit temp. (≤5 s) |
250 °C |
|
Emergency overload temp. |
130 °C (≤1 h) |
|
Min. installation ambient temp. |
0 °C (below 0 °C requires preheating) |
|
Service ambient range |
−20 °C to +90 °C |
|
Flexing temp. range |
0 °C to +90 °C |
Fire Performance (ZC-YJV — Flame Retardant C)
|
Property |
Value / Requirement |
|---|---|
|
Flame retardant |
GB/T 18380.12 / IEC 60332-1-2 (single cable, self-extinguishing) |
|
Flame retardant class |
Class C (ZC) per GB/T 19666 |
|
Halogen content |
Contains halogen (PVC sheath) |
|
Smoke density |
Not low-smoke (PVC) |
|
Corrosivity |
Corrosive (PVC) |
|
Toxicity |
Toxic fumes when burned (PVC) |
|
EMI shielding |
None (no metallic screen/armour) |
5. Installation Practice & Handling. 25 mm² phase lugs, 16 mm² neutral lug, glands to ≈12 mm OD, small crimp/torque per table; bend ≥ 15×OD ≈ 180 mm; apply conduit/bundle derating; keep the 3+1 bundle tidy; verify three-phase continuity, sequence, neutral and insulation after pulling.
Mechanical & Installation Parameters
|
Parameter |
Value |
Remarks |
|---|---|---|
|
Minimum bending radius |
≥ 15 × OD → ≈ 270 mm at Ø18.0 mm |
four-core unarmoured |
|
Max. pulling tension (phase) |
375 N per core (25 mm² × 15 N/mm²) |
Cu conductor limit |
|
Max. pulling tension (neutral) |
240 N per core (16 mm² × 15 N/mm²) |
Cu conductor limit |
|
Direct burial |
Suitable (with sand bedding) |
— |
|
Surface mounting |
Cable tray, ladder, cleats |
— |
|
Conduit ID |
≥ 35 mm |
— |
|
Fixing |
cable ties, cleats |
— |
|
Impact resistance |
Moderate |
— |
|
Water resistance |
Good (PVC sheath) |
— |
|
UV resistance |
Fair (PVC degrades outdoors, use UV-resistant PVC or conduit) |
— |
|
Flex life |
Good (Class 2 stranded) |
fixed installation |
|
Termination note |
Standard compression lugs or mechanical connectors |
— |
6. Typical Service Applications. 380/400 V small three-phase motors, fans, pumps, control-panel outgoing feeders, cabinet-to-equipment links and mixed lighting-plus-power branches.

7. Testing & QA Regime (16 items). Routine: phase DC resistance (25), neutral DC resistance (16), 3.5 kV withstand, insulation resistance, 3-phase+neutral continuity, phase/neutral insulation thickness, sheath thickness, dimensional check, strand construction, eccentricity, print legibility, mass, packing inspection. Type: ZC flame test, short-circuit rating, sheath mechanical.
Cable Parameters
| ZC-YJV 3×25+1×16 mm² — LV Flame-Retardant 3+1 Power Cable — Full Parameter Sheet | |||
| 3×25 phase Cu + 1×16 neutral Cu · XLPE insulation / PVC sheath · ZC · 0.6/1 kV · ≈12 mm · 3+1 lay · 380/400 V small motor, control panel outgoing & mixed power-lighting branch | |||
| Parameter | Value | Unit | Remarks / Standard |
| 01 · Identification | |||
| Cable type | ZC-YJV — Cu/XLPE/PVC, flame-retardant class C | — | ZC-YJV denotes a copper conductor with cross-linked polyethylene insulation and a PVC outer sheath; ZC marks a class C flame-retardant PVC compound that self-extinguishes after the ignition source is removed. |
| Rated voltage (U0/U) | 0.6/1 | kV | 0.6 kV phase-to-earth (U0) and 1 kV phase-to-phase (U) rating defines a general low-voltage cable suited to 380/400 V small-motor and control-panel branch circuits. |
| Maximum operating voltage (Um) | 1.2 | kV | The 1.2 kV maximum system voltage is the continuous upper phase-to-earth limit the XLPE insulation may withstand in normal service. |
| Core configuration | 3×25 phase + 1×16 neutral (3+1) | — | Three 25 mm² compacted copper phase cores plus one 16 mm² compacted neutral core, laid in a compact 3+1 arrangement for small motors and control outgoing circuits. |
| Conductor material | Compacted stranded annealed copper | — | Soft annealed copper strands are layer-compacted into round 25 mm² phase and 16 mm² neutral bundles for compact lug entry. |
| Insulation | XLPE cross-linked polyethylene | — | Chemically cross-linked polyethylene bonds into a heat-resistant dielectric retaining properties at the 90 °C operating temperature. |
| Sheath | PVC, flame-retardant class C (ZC) | — | An overall PVC jacket binds the compact 3+1 bundle and carries the class C flame-retardant formulation; deep slate steel blue finish. |
| Flame retardancy | ZC class C (self-extinguishing, not fire-rated) | — | On removal of a flame the cable stops propagating fire; this is flame retardancy, not 950 °C/180 min circuit-integrity fire resistance. |
| Suitable for | Small motor, control outgoing, mixed branch | — | Designed for fixed small three-phase motors, control-panel outgoing feeders and mixed power-plus-lighting branch circuits. |
| Application | 380V small motor / control cabinet branch | — | Typically runs from a control cabinet or small distribution board to a small motor, fan, pump or mixed lighting-and-power load. |
| Application note | Not for 950°C circuit-integrity fire duty | — | Do not substitute this ZC cable for a mineral-insulated or fire-resistant circuit; it cannot maintain live integrity under sustained fire. |
| 02 · Conductors | |||
| Phase cores count / area | 3 × 25 (L1/L2/L3) | mm² | Three 25 mm² phase conductors carrying the small three-phase motor or branch load current. |
| Neutral core count / area | 1 × 16 (N) | mm² | One 16 mm² neutral conductor sized for the branch neutral return on predominantly balanced small loads. |
| Conductor type | Compacted stranded Cu, Class 2 | — | Class 2 stranded compacted construction gives fixed-wiring conductors that round into stable small bundles for lug termination. |
| DC resistance (25 phase) @ 20°C | ≤ 0.741 | Ω/km | Maximum permitted DC resistance of a 25 mm² copper phase conductor at 20 °C, applied to L1/L2/L3. |
| DC resistance (16 neutral) @ 20°C | ≤ 1.15 | Ω/km | Maximum permitted DC resistance of the 16 mm² neutral conductor at 20 °C; higher than phases by design of the reduced neutral. |
| Stranding | Layer-compacted concentric bundle | — | Concentric layers of strands are compacted radially per core to reduce gaps, tighten the bundle and present a clean round lug entry. |
| Strands (nom., est.) | 25 ≈7; 16 ≈7 strands per core | — | Approximate compacted strand counts; exact count follows the conductor standard for each section. |
| Surface | Bare copper; tinned optional | — | Bare copper suits most indoor use; optional tinned plating improves corrosion resistance in damp or chemically mild sites. |
| Core identification | L1/L2/L3 phase colors + N neutral | — | Phase cores and the smaller neutral are color-coded so phase sequence and neutral match at the motor or cabinet terminal. |
| Neutral sizing logic | Reduced neutral for balanced small loads | — | The 16 mm² neutral suits balanced three-phase small loads; enlarge the neutral where LED rectifier or VFD harmonics are high. |
| Compaction benefit | Compact round bundle, tidy OD, clean crimp | — | Radial compaction reduces overall diameter versus loose stranding and gives a flat, even lug crimp on both sections. |
| 03 · Insulation | |||
| Insulation material | XLPE (cross-linked polyethylene) | — | Cross-linked PE delivers a higher continuous temperature rating and lower dielectric loss than PVC insulation for the same size. |
| Insulation thickness (25 phase, nom.) | ≈ 1.3 | mm | Nominal radial insulation wall on each 25 mm² phase core; gauged to withstand the 3.5 kV routine test. |
| Insulation thickness (16 neutral, nom.) | ≈ 1.2 | mm | Nominal insulation wall on the smaller 16 mm² neutral core, matched to its voltage class. |
| Working conductor temp. | 90 | °C | Maximum continuous conductor temperature under rated current without shortening insulation life. |
| Short-circuit temp. | 250 | °C | Peak conductor temperature the insulation may survive for a short fault duration (seconds) before damage occurs. |
| Insulation resistance | High and stable | MΩ·km | XLPE keeps a high, stable insulation resistance over life, supporting reliable earth-fault detection on small branch feeders. |
| Color | L1/L2/L3/N color on request | — | Insulation colors are matched to local 3-phase convention or supplied natural with printed marking. |
| Cure type | Chemical / dry-cured XLPE | — | A controlled cross-linking cure locks the polymer network so the insulation stays elastic rather than melting under heat. |
| 04 · Sheath & Flame Retardancy | |||
| Sheath material | PVC, flame-retardant ZC | — | The class C PVC outer jacket blends a flame-suppressing formulation while keeping a smooth, printable surface. |
| Sheath thickness (nom.) | ≈ 1.2 | mm | Nominal overall jacket wall sized to shield the compact 3+1 bundle from abrasion and mechanical handling. |
| Finished outer diameter | ≈ 12 | mm | Compact overall 3+1 finished diameter used to size glands, trunking and small conduit on branch runs. |
| Flame behavior | Self-extinguishing, class C | — | After the test flame is removed the sample extinguishes without propagating; it is not 950°C fire-rated. |
| Sheath color | Deep slate steel blue (black/gray on request) | — | Standard deep slate steel blue; black or dark gray jackets are supplied for industrial aesthetics on request. |
| Surface finish | Smooth, continuous print | — | A smooth jacket carries a continuous printed line of type, size, voltage, ZC class and meter length along its length. |
| 05 · Electrical | |||
| Rated voltage (U0/U) | 0.6/1 | kV | Low-voltage rating matching 380/400 V small-motor and control branch systems. |
| Max voltage (Um) | 1.2 | kV | Continuous upper system voltage for phase-to-earth insulation stress. |
| Nominal current (per 25 phase, est.) | ≈ 78 | A | Approximate ampacity of a 25 mm² phase core in free air at 30 °C; reduce for conduit fill and high ambient. |
| Test voltage (AC) | 3.5 kV / 5 min | — | Routine dielectric withstand applied between each conductor and sheath for five minutes without breakdown. |
| Insulation resistance | High, XLPE | MΩ·km | Measured after conditioning; confirms no void, crack or contamination in the cured insulation. |
| Short-circuit current (25 phase, 1s, est.) | ≈ 2.4 | kA | Approximate 1-second copper short-time withstand on the 25 mm² phase core; small branch fault coordination. |
| Frequency | 50 / 60 | Hz | Compatible with both 50 Hz and 60 Hz three-phase power systems. |
| Dielectric | XLPE, low loss | — | Low dielectric loss keeps heating down under continuous small motor and branch duty. |
| 06 · Thermal & Environment | |||
| Normal conductor temp. | 90 | °C | Sustained operating temperature the XLPE insulation is rated for under full load. |
| Installed ambient | 0 ~ +40 | °C | Recommended continuous ambient around the cable; crowded control cabinets and small ducts require ampacity derating. |
| Min install temp. | 0 | °C | Avoid cold bending below 0 °C where the PVC jacket and insulation may stiffen and crack. |
| Burning | Self-extinguishing, ZC class C | — | Class C vertical flame test behavior: flame stops once the external burner is removed. |
| Outdoor / UV | Indoor preferred; UV-grade jacket optional | — | Standard PVC degrades under prolonged direct sun; specify UV-stabilized jacket for exposed outdoor small runs. |
| Oil / chemicals | Resistant to common oils; check aggressive media | — | Withstands typical machine oils; verify against specific solvents, cleaning agents or acid fumes before use. |
| Temperature cycle | Withstands repeated 0~90°C duty | — | The insulation and jacket survive repeated motor start-stop and branch switching cycles without cracking. |
| 07 · Mechanical & Construction | |||
| Min bending radius (fixed) | ≥ 15 × OD ≈ 180 | mm | Fixed-installation minimum bend radius for the compact 3+1 cable; suitable for tight cabinet routing. |
| Flexibility | Stranded, flexible for cabinet and conduit | — | Compact strands remain flexible enough for panel-to-equipment routing and small-bend conduit runs. |
| Shielding / Armor | None / unarmored (screen optional) | — | No braid screen and no armor as standard; add braid screen near control EMI; armor rarely needed for this small section. |
| Cable weight per km (est.) | ≈ 760 | kg/km | Light compact mass per kilometer used for cabinet fill and small drum sizing. |
| Circularity | Compact 3+1 bundle, small OD | — | Three phases around the reduced neutral form a compact round bundle after sheathing. |
| Tensile / elongation | Jacket meets PVC grade | — | Jacket tensile strength and elongation satisfy the PVC compound grade for routine pulling. |
| 08 · Factory Advantages | |||
| Compact balanced 3+1 sizing | 3×25 phases with 1×16 neutral for small loads | — | Right-sized reduced neutral avoids excess copper cost on balanced small three-phase branches. |
| Stable XLPE cure | Even cross-linking keeps the 90°C dielectric consistent | — | Controlled cure prevents soft spots in the thin insulation under repeated switching cycles. |
| Dosed ZC compound | Flame-retardant PVC self-extinguishes to class C | — | Self-extinguishing jacket protects control cabinets and small distribution wiring spaces. |
| Length-on-demand | Cut to exact cabinet/machine meter, sealed ends | — | Custom cut lengths match the measured control outgoing and small branch route. |
| Dual-section resistance log | Phase 25 and neutral 16 R logged to lot | — | Both conductor sections are recorded for incoming inspection and batch traceability. |
| Continuous print line | Type, size, ZC, voltage and length along jacket | — | Clear continuous marking lets installers read phase and neutral section along short flexible branch runs. |
| Phase-color option | L1/L2/L3/N insulation colors matched to convention | — | Pre-colored cores reduce wiring errors at cabinet terminal blocks and motor boxes. |
| Lightweight drum pack | Small reel or short-length coil option | — | Compact mass supports small reels or short coiled lengths for site handling. |
| Certified QA pack | Routine + type test record shipped per batch | — | A complete QA packet supports buyer inspection and control-circuit commissioning sign-off. |
| 09 · Installation | |||
| Laying | Control outgoing, small motor, mixed branch | — | Route in control cabinets, trays, small conduit or direct to equipment; keep the 3+1 bundle tidy and observe bend radius. |
| Connectors | 25 mm² phase lugs; 16 mm² neutral lug | — | Crimp 25 mm² lugs on L1/L2/L3 and a 16 mm² lug on N; select small glands sized to ≈12 mm OD. |
| Bend radius | ≥ 15×OD ≈ 180 mm | — | Maintain the minimum radius around cabinet entries and conduit elbows to avoid insulation stress. |
| Parallel runs | Derating in bundles and small ducts | — | Adjacent loaded cores share heat; apply derating factors before selecting the small branch breaker. |
| Site test | Continuity + insulation post-laying | — | After pulling, verify three-phase continuity, phase sequence, neutral continuity and insulation resistance. |
| Termination | Strip, small hydraulic/hand crimp, torque | — | Strip insulation without nicking strands, use matched small dies on each lug, and torque per the lug table. |
| 10 · Packing & Applications | |||
| Supply length | Custom / small drum or coil | m | Cut to the measured small branch length on a small drum or coil. |
| Length tolerance | Per trade standard for cut lengths | — | Cut-length tolerance follows the applicable trade standard rather than a fixed meter promise. |
| Reel type | Small wooden reel / coiled length | — | Light section wound on a small reel or sealed coil; ends sealed against moisture. |
| Surface marking | ZC-YJV, 3×25+1×16, 0.6/1kV, ZC, length | — | Jacket prints type, phase/neutral section, voltage, flame class and cumulative meter length. |
| Typical use | Small motor, fan, pump, control outgoing, mixed branch | — | Small three-phase motors, fans, pumps, control-panel feeders and mixed lighting-power branches. |
| Storage | Dry indoor on reel supports, avoid UV | — | Store horizontally on timber supports, dry and shaded; keep ends sealed until installation. |
Cable Test Parameters
| Test Parameters — ZC-YJV 3×25+1×16 LV Flame-Retardant 3+1 Cable | ||||
| No. | Test Item | Test Condition / Method | Requirement | Type |
| 1 | DC resistance (25 phase) | 20 °C, L1/L2/L3 (25 mm²) | ≤0.741 Ω/km | Routine |
| 2 | DC resistance (16 neutral) | 20 °C, N (16 mm²) | ≤1.15 Ω/km | Routine |
| 3 | Voltage test (AC) | 3.5 kV AC, 5 min, core-to-sheath | No breakdown | Routine |
| 4 | Insulation resistance | XLPE, 20°C, per core | High & stable | Routine |
| 5 | Continuity | 3 phases + neutral | Continuous | Routine |
| 6 | Flame retardancy | Class C vertical test | Self-extinguish | Type |
| 7 | Sheath thickness | Micrometer, cross-section | Nominal ≈1.2 mm | Routine |
| 8 | Phase insulation thickness | Micrometer, 25 mm² cores | Nominal ≈1.3 mm | Routine |
| 9 | Neutral insulation thickness | Micrometer, 16 mm² core | Nominal ≈1.2 mm | Routine |
| 10 | Dimensional check | Caliper, overall OD | OD ≈ 12 mm | Routine |
| 11 | Conductor construction | Visual / strand count per core | Class 2 compacted | Routine |
| 12 | Short-circuit rating | Calculated / type | ≈2.4 kA / 1 s | Type |
| 13 | Insulation eccentric test | Cross-section measure per core | Within tolerance | Routine |
| 14 | Printing legibility | Visual | Marking readable | Routine |
| 15 | Mass per unit length | Weigh / calculate | ≈ 760 kg/km | Routine |
| 16 | Packing & reel inspection | Visual / reel and sealed ends | Sealed ends, sound reel | Routine |
Cable Cross Section Structure

| ZC-YJV 3×25+1×16 — 3+1 Cross-Section Construction Diagram | |||||
| 3×25 phase Cu + 1×16 neutral Cu / XLPE insulation / PVC ZC sheath · 0.6/1 kV · ZC class C · ≈12 mm · small motor, control outgoing & mixed branch | |||||
| No. | Layer / Feature | Material / Construction | Nominal Thickness (mm) | Diameter (mm) | Detailed Function / Remarks |
| 1 | Conductor L1 — phase | 1×25 compacted Cu, Class 2, ≈7 strands | — | ≈ 5.6 | Phase 1 core, DC R ≤0.741 Ω/km @20°C; small motor current. |
| 2 | Conductor L2 — phase | 1×25 compacted Cu, Class 2, ≈7 strands | — | ≈ 5.6 | Phase 2 core, equal size/resistance for balanced three-phase. |
| 3 | Conductor L3 — phase | 1×25 compacted Cu, Class 2, ≈7 strands | — | ≈ 5.6 | Phase 3 core, equal spec; color-coded for phase sequence. |
| 4 | Conductor N — neutral | 1×16 compacted Cu, Class 2, ≈7 strands | — | ≈ 4.5 | Reduced neutral, R ≤1.15 Ω/km; balanced small-load neutral return. |
| 5 | Strand compaction | Concentric layers rolled compact per core | — | — | Radial compaction closes gaps for a compact round bundle and clean lugs. |
| 6 | XLPE insulation (25 phase) | Dry-cured cross-linked PE, ≈1.3 mm | ≈ 1.3 | ≈ 8.2 | 90°C phase dielectric; low loss, passes 3.5 kV routine test. |
| 7 | XLPE insulation (16 neutral) | Dry-cured cross-linked PE, ≈1.2 mm | ≈ 1.2 | ≈ 6.9 | Neutral dielectric matched to the smaller 16 mm² section. |
| 8 | 3+1 core laying | 3 phases around 1 reduced neutral | — | — | Compact 3+1 arrangement settles into a small round finished form. |
| 9 | PVC ZC sheath | Class C jacket, ≈1.2 mm | ≈ 1.2 | ≈ 12 | Binds the compact bundle; self-extinguishes to class C; steel-blue finish. |
| 10 | Jacket print | Continuous type/size/voltage/length line | — | — | Marking: ZC-YJV, 3×25+1×16, 0.6/1kV, ZC, cumulative length. |
| Key Dimensions, Electrical & Mechanical Properties (expanded) | |||||
| Finished cable diameter | ≈ 12 | mm | Compact 3+1 branch OD for small glands and conduit. | ||
| Approx. cable mass (est.) | ≈ 760 | kg/km | Light compact mass; small reel or coil. | ||
| Nominal voltage rating | 0.6/1 | kV | Matches 380/400 V small-motor systems. | ||
| Max voltage (Um) | 1.2 | kV | Phase-to-earth continuous upper limit. | ||
| Normal conductor temp. | 90 | °C | Continuous load temperature of XLPE. | ||
| Short-circuit temp. | 250 | °C | Short-time fault peak before insulation damage. | ||
| DC resistance (25 phase) | ≤ 0.741 | Ω/km | Per phase core @20°C. | ||
| DC resistance (16 neutral) | ≤ 1.15 | Ω/km | Reduced neutral @20°C. | ||
| Neutral sizing | 1×16 reduced neutral | — | For balanced small loads; enlarge on high harmonics. | ||
| Nominal phase current (est.) | ≈ 78 | A | Per 25 phase core, free air 30°C; derate in conduit. | ||
| Short-circuit rating (1s, est.) | ≈ 2.4 | kA | Small branch fault coordination. | ||
| Flame retardancy | ZC class C, self-extinguishing | — | Not 950°C fire-rated. | ||
| Min bending radius (fixed) | ≥ 15 × OD ≈ 180 | mm | Cabinet and small-conduit bend radius. | ||
| Frequency | 50 / 60 | Hz | Compatible with both power systems. | ||
| Insulation resistance | High & stable | MΩ·km | XLPE; supports earth-fault detection. | ||
| Dielectric loss | Low | — | XLPE limits heating on small branch duty. | ||
| Temperature cycle | 0~90°C repeated | — | Survives switching and start-stop cycling. | ||
| Sheath mechanical | Jacket meets PVC grade | — | Tensile/elongation checked at type test. | ||
| Pack choice | Small reel / coiled length | — | Light section with sealed cable ends. | ||
| Application | Small motor, control outgoing, mixed branch | — | 380/400 V fans, pumps, cabinets and mixed branches. | ||
| Schematic — not to exact scale. OD ≈12 mm, weight ≈760 kg/km, phase ampacity ≈78 A free air at 30°C and ≈2.4 kA/1s are (est.) from cross-referenced industry samples. ZC-YJV 3×25+1×16 serves 380/400 V small motors, control-panel outgoing feeders and mixed branches; ZC class C self-extinguishes but is not 950°C fire-rated. Estimated values require confirmation against the factory test certificate for the specific batch. | |||||
Cable Construction Description
| Construction Description — ZC-YJV 3×25+1×16 LV flame-retardant 3+1 cable | |||
| 3×25 phase Cu + 1×16 neutral Cu / XLPE insulation / PVC ZC sheath · 0.6/1 kV · ZC class C · 90°C · ≈12 mm · small motor, control outgoing & mixed branch | |||
| 1. Product Identity & Ratings | |||
| ZC-YJV 3×25+1×16 rated 0.6/1 kV (Um 1.2), 90°C working, ZC class C; three 25 mm² phase cores plus one 16 mm² neutral in a compact 3+1 lay. OD ≈12 mm, ≈760 kg/km (est.), ≈78 A per phase free air at 30°C (est.), small reel or coil. It is a fixed small branch cable, not a flexible cord and not a 950°C fire-rated circuit. | |||
| 2. Copper Conductors (3×25 phase + 1×16 neutral) | |||
| Three compacted Class 2 Cu phase cores (L1/L2/L3), R ≤0.741 Ω/km @20°C, plus one 16 mm² neutral, R ≤1.15 Ω/km @20°C; reduced neutral suits balanced small loads; tinned plating optional; phase-color insulation on request. | |||
| 3. Strand Compaction & 3+1 Bundle | |||
| Concentric strands are rolled compact per core to close gaps and give clean small-lug entry; three phases surround the reduced neutral to form a compact round 3+1 bundle before sheathing. | |||
| 4. XLPE Insulation | |||
| Dry-cured cross-linked PE ≈1.3 mm on phases and ≈1.2 mm on the neutral; stable 90°C dielectric, low dielectric loss, high insulation resistance; short-circuit peak 250°C; matched wall per section. | |||
| 5. Core Identification | |||
| L1/L2/L3 phases and the N neutral are identified by insulation color; the smaller neutral section also distinguishes it visually at the cabinet terminal block or motor box. | |||
| 6. PVC ZC Sheath | |||
| Class C flame-retardant PVC ≈1.2 mm overall, self-extinguishing; deep slate steel blue standard (black/gray on request); smooth printable surface; binds the compact bundle and shields from cabinet abrasion. | |||
| 7. Electrical Characteristics | |||
| 0.6/1 kV, Um 1.2; phase R ≤0.741, neutral R ≤1.15 Ω/km; routine 3.5 kV AC/5 min; ≈78 A per phase (est., air 30°C); short-circuit ≈2.4 kA/1s (est.); 50/60 Hz; unscreened; low-loss XLPE. | |||
| 8. Factory Advantages | |||
| • Compact balanced 3+1 sizing. • Stable XLPE cure. • Dosed ZC self-extinguish. • Length-on-demand. • Dual-section resistance log. • Continuous clear print. • Phase-color option. • Lightweight reel pack. • Certified QA pack. | |||
| 9. Site Handling & Installation | |||
| • Bend 15×OD (≈180 mm). • 25 mm² phase lugs, 16 mm² neutral lug, glands to ≈12 mm OD, small crimp, torque per table. • Conduit/bundle derating. • Keep 3+1 bundle tidy. • Three-phase continuity, sequence, neutral + insulation after pulling. | |||
| 10. Typical Service Applications | |||
| 380/400 V small three-phase motors, fans, pumps, control-panel outgoing feeders, cabinet-to-equipment links and mixed lighting-plus-power branch circuits. | |||
| 11. Testing & QA | |||
| 16-item regime: routine phase DC resistance (25), neutral DC resistance (16), 3.5 kV withstand, insulation resistance, 3-phase+neutral continuity, phase/neutral insulation thickness, sheath thickness, dimensional check, strand construction, eccentricity, print legibility, mass, packing inspection; type ZC flame, short-circuit, sheath mechanical. | |||
| 12. Packaging, Storage & Notes | |||
| Cut to measured branch length on a small reel or coil with sealed ends; continuous marking; store dry indoor on reel supports, shaded, avoid direct UV. Est. OD/weight/ampacity/short-circuit confirmed against the factory certificate; ZC is flame retardant, not 950°C fire-rated. |
8. Factory Advantages.
- Compact balanced 3+1 sizing — 3×25 phases with 1×16 neutral, cost-effective on balanced small loads.
- Stable XLPE cure — even cross-linking keeps the 90°C dielectric consistent under switching cycles.
- Dosed ZC compound — self-extinguishing jacket protects cabinets and wiring spaces.
- Length-on-demand — cut to exact cabinet/machine meter with sealed ends.
- Dual-section resistance log — phase 25 and neutral 16 R logged to lot.
- Continuous print line — type, size, ZC, voltage and length along jacket.
- Phase-color option — L1/L2/L3/N colors matched to convention, fewer wiring errors.
- Lightweight reel pack — small reel or short coiled length for site handling.
- Certified QA pack — routine + type test record shipped per batch.

9. Packaging, Storage & Logistics. Cut to measured branch length on a small reel or coiled length with sealed ends; continuous marking; store dry indoor on reel supports, shaded, avoid direct UV.

10. Procurement Specification. State "ZC-YJV 3×25+1×16", length, class C, phase colors, braid screen near EMI if required; note reduced neutral for balanced small loads and not fire-rated; request dual-section resistance log and the 16-item QA record. Est. values confirmed against the factory certificate.
11. Cable Industry FAQ.
- Q1: How does 3×25+1×16 differ from 3×50+1×25? Next size down: phases 25 vs 50 mm², neutral 16 vs 25 mm²; slimmer OD (12 vs 16 mm), lighter (760 vs 1450 kg/km), lower current (78 vs 120 A), higher resistance (0.741/1.15 vs 0.387/0.741 Ω/km); serves small control branches rather than main motor feeds.
- Q2: Why a reduced 16 mm² neutral? Balanced small three-phase loads draw little neutral current, so a 16 mm² neutral saves copper; enlarge it under LED/VFD harmonic-heavy duty.
- Q3: Is ZC fire-resistant? No. Class C self-extinguishes; it does not hold live at 950°C/180min.
- Q4: DC resistance values? Phase 25 ≤0.741 Ω/km; neutral 16 ≤1.15 Ω/km at 20°C.
- Q5: Screen or armor? Unscreened standard; add braid screen near control EMI; armor unnecessary at this small section.
- Q6: Current per phase? ≈ 78 A (est.) free air 30°C; derate in conduit and crowded cabinets.
- Q7: Bending? ≥ 180 mm (15×OD); fits tight cabinet routing.
- Q8: Connectors? 25 mm² phase lugs, 16 mm² neutral lug, gland to ≈12 mm OD.
- Q9: Indoor or outdoor? Indoor preferred; specify UV-stabilized jacket for exposed short runs.
- Q10: Packing? Small reel or sealed coiled length.
- Q11: What proof ships? Dual-section resistance log + 16-test record; est. values confirmed against certificate.