"pvc single core electrical cable"
- 90 Items Found
0.6/1kV ZC-YJV 5x16mm² Copper XLPE PVC Flame-Retardant Power Cable for Residential Main Distribution
0.6/1kV ZC-YJV 5x16mm² Copper XLPE PVC Flame-Retardant Power Cable for Residential Main Distribution Technical Datasheet — ZC-YJV 0.6/1 kV 5×16 mm² 1. Cable Designation & Meaning Code Meaning ZC Flame retardant, Class C (bundled combustion test per GB/T 18380.3 / GB/T 19666) YJ XLPE (cross...
Copper Power Cable 4 Core ZR-YJV 3×150mm2+1×70mm2 For Power System
Flame Retardant Copper Cable ZR-YJV 3×150mm²+1×70mm² for Commercial Building Power System Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 3×150 mm² + 1×70 mm² Three phase cores of 150 mm² + one ...
0.6/1kV 3 Cores Cable 3x16mm2 Stranded Copper Conductor XLPE Insulation PVC Outer Sheath
0.6/1kV ZC-YJV 3x16mm² Stranded Copper Conductor XLPE Insulation PVC Outer Sheath Low Voltage Power Cable Technical Datasheet — ZC-YJV 0.6/1 kV 1×16 mm² 1. Cable Designation & Meaning Code Meaning ZC Flame retardant, Class C (bundled combustion test) YJ XLPE (cross-linked polyethylene) insulation ...
ZR-YJV 4×35mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath
ZR-YJV 4×35mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×35 mm² Four equal cores of 35 mm² copper conductor Construction ...
ZR-YJV 1*50mm² Flame Retardant Cable, 0.6/1kV Pure Copper XLPE Insulation PVC Sheath for Power Wiring
ZR-YJV 1*50mm² Flame Retardant Cable, 0.6/1kV Pure Copper XLPE Insulation PVC Sheath for Power Wiring Code Mean:ZR-Flame Retardant, YJ-XLPE Insulation, V-PVC Outer Sheathed. ZR-YJV 1×50 mm² — Detailed Product Introduction ZR-YJV 1×50 is a flame-retardant, copper-conductor, XLPE-insulated, PVC...
2x16mm2 2 Core Fiber Optic Cable IEC Full Gauge Copper PVC Sheath For Power Engineering
ZR-YJV 2*16mm² Flame Retardant 2 Core Cable,0.6/1kV IEC Standard Full Gauge Copper,XLPE Anti-Aging PVC Sheath for Power Engineering Cable Designation & Meaning Code Meaning ZC Flame retardant C — IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 2×16 mm² Two ...
Class 2 x 25mm2 2 Cores Cable Flame Retardant Copper Cable Xlpe Insulation Pvc Sheath
ZR-YJV 2*25mm² Flame Retardant Copper Cable,0.6/1kV XLPE Insulation PVC Sheath for Power Distribution Cable Designation & Meaning Code Meaning ZC Flame retardant C— IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 2×25 mm² Two cores, 25 mm² copper conductor each ...
2x35mm2 2 Cores Cable Stranded Copper Low Voltage Power Cable ZR Grade
ZR-YJV 2*35mm² Flame Retardant 2 Core Cable, 0.6/1kV Stranded Copper, XLPE Insulation PVC Jacket for Construction Power Cable Designation & Meaning Code Meaning ZC Flame retardant C (成束燃烧C类阻燃) — IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 2×35 mm² Two cores...
2 X 70mm2 2 Cores Cable ZR-YJV Flame Retardant PVC Insulation Jacket 0.6/1kV
ZR-YJV 2*70mm² Flame Retardant 2 Core Cable, 0.6/1kV, XLPE Insulation PVC Jacket for Construction Power Cable Designation & Meaning Code Meaning ZC Flame retardant C — IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 2×70 mm² Two cores, 70 mm² copper conductor ...