logo
Anhui Tongdu International Trade Co., Ltd.
Online Service

Online Service

Contact Person
+86 19056002718
WeChat QR Code
Follow Us

3x400mm2 Medium Voltage Cable XLPE Armored XLPE Wire 26KV 35kV

3x400mm2 Medium Voltage Cable XLPE Armored XLPE Wire 26KV 35kV

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
YJLV22 3x400mm²

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
100000 meters per month

Product Summary

YJLV22 3x400mm² Aluminum XLPE Armored HV Cable 26/35kV for Urban Power Distribution Cable Designation & Meaning Code Meaning 26/35 kV Rated voltage: U₀ = 26 kV (phase-to-earth), U = 35 kV (phase-to-phase) YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Lü = aluminium) V PVC ...

Product Details

Highlight:

3x400mm2 medium voltage cable

,

xlpe wire 26kv

,

3x400mm2 xlpe wire

Conductor (×3):
Aluminium, Class 2 Stranded Sector-shaped, Nominal 37×∅3.71 Mm (400 Mm²), Conductor Ø ≈ 26–28 Mm (sector)
Conductor screen:
Semi-conductive Compound Layer, Thickness ≈ 0.5 Mm
Insulation:
XLPE (cross-linked Polyethylene), Nominal Thickness 4.5 Mm​ (for 26/35 KV Class)
Insulation screen:
Semi-conductive Compound Layer, Thickness ≈ 0.5 Mm
Metallic screen:
Copper Tape Screen Over Each Core (optional For 3-core) Or Collective Copper Wire Screen
Filler & bedding:
PVC Filler, Round Profile, Inner PVC Bedding Thickness ≈ 1.5 Mm
Armour:
Double Steel Tape, Thickness 0.5 Mm × 2 Layers (overlapped)
Outer sheath:
PVC​ (polyvinyl Chloride), Nominal Thickness 3.0 Mm (typical), Colour: Black
Conductor nominal area:
400 Mm² (Al)
Number of cores:
3
Conductor material:
Aluminium (Al)
Conductor class:
Class 2 Stranded Sector
Conductor construction:
37×∅3.71 Mm (typical)
Conductor diameter (approx.):
26–28 Mm (sector Width)
Insulation thickness:
4.5 Mm
Diameter over insulation (approx.):
35–38 Mm
Bedding thickness:
1.5 Mm
Armour (steel tape):
0.5 Mm × 2 Layers
Outer sheath thickness:
3.0 Mm
Overall cable diameter:
85 – 100 Mm
Design outer diameter:
≈ 92 Mm
Approx. weight:
8.5 – 10.5 Kg/m (8500–10500 Kg/km)
Design weight:
≈ 9200 Kg/km
Cable shape:
Round

Product Description

YJLV22 3x400mm² Aluminum XLPE Armored HV Cable 26/35kV for Urban Power Distribution

Cable Designation & Meaning

 

Code

Meaning

26/35 kV

Rated voltage: U₀ = 26 kV (phase-to-earth), U = 35 kV (phase-to-phase)

YJ

XLPE (cross-linked polyethylene) insulation

L

Aluminium conductor (Lü = aluminium)

V

PVC outer sheath

22

Steel tape armoured (double steel tape)

3×400 mm²

Three cores, each 400 mm² aluminium

 

Construction: Aluminium conductor, XLPE insulation, semi-con screens, steel tape armour, PVC sheath, three-core medium voltage power cable.

 

3x400mm2 Medium Voltage Cable  XLPE Armored  XLPE Wire 26KV 35kV

 

3x400mm2 Medium Voltage Cable  XLPE Armored  XLPE Wire 26KV 35kV

 

YJLV22-3×400 mm² (26/35 kV) — High-Voltage XLPE Insulated Steel-Tape Armored Aluminum Power Cable — Specification & Engineering Data 

1. Overview & Ratings. YJLV22-3×400 — medium-voltage XLPE-insulated, double steel-tape armored, PVC-sheathed aluminum-conductor power cable, three 400 mm² compacted aluminum conductors (L1/L2/L3), rated 8.7/10 kV (Um = 12 kV), 50 Hz; built and tested per GB/T 12701 / IEC 60840, stranding per GB/T 3956. This is a standard MV distribution cable — NOT a fire-resistant cable. Ø ≈ 85 mm, ≈ 6200 kg/km, steel drums.

 

2. Construction Stack (Conductor → Outer).

Layer Build Wall Diameter
Conductors (×3) Compacted stranded Al, Class 2, 3×400 mm² — ≈ 24 mm
Conductor screen Extruded semi-conducting — —
XLPE insulation Cross-linked polyethylene ≈ 5.5 mm ≈ 35 mm
Insulation screen Semi-conducting + Cu tape ≈ 0.1 mm Cu —
Inner PVC bedding PVC over cored assembly ≈ 1.8 mm ≈ 72 mm
Steel tape armor (22) Double galvanized steel tape ≈ 2×0.5 mm ≈ 78 mm
Outer PVC sheath PVC ST2, black, UV-resistant ≈ 2.5 mm ≈ 85 mm (finished)

 

3. Electrical Characteristics. R ≤ 0.124 Ω/km at 20 °C (Al 400 mm²); routine test 21 kV AC / 5 min; partial discharge ≤ 10 pC at 12 kV; insulation resistance ≥ 1000 MΩ·km; capacitance ≈ 0.22 μF/km; tan δ ≤ 0.0004 at 90 °C. Reference ampacity ≈ 410 A (free air, 25 °C).

Insulation Data

Property

Value

Material

XLPE (cross-linked polyethylene)

Nominal thickness

10.5 mm (26/35 kV class)

Long-term service temp.

90 °C

Short-circuit temp. (≤5 s)

250 °C​ (Al conductor limit per IEC 60228)

Emergency overload temp.

130 °C

Routine test voltage (AC, 5 min)

65 kV (for 26/35 kV)

Type-test voltage (AC)

91 kV (for 26/35 kV)

Partial discharge test

≤ 10 pC at 1.5 U₀ (39 kV)

Tan δ (dissipation factor)

≤ 0.004 at 20 °C

 

Electrical Parameters

 

Parameter

Value

Note

Rated voltage U₀/U

26 / 35 kV

GB/T 12706.2 / IEC 60502-2

Max. system voltage Uₘ

40.5 kV

—

Test voltage AC (5 min)

65 kV

Routine test (26/35 kV)

DC resistance @20 °C

≤ 0.0778 Ω/km

GB/T 3956 Class 2 Al max, 400 mm²

AC resistance @90 °C (est.)

≈ 0.099 Ω/km

per core

Capacitance (approx.)

≈ 0.22 µF/km

core to screen

Inductive reactance (approx.)

≈ 0.13 Ω/km

at 50 Hz, 3-core armoured

Current rating in air (30 °C)

415 A​

3-core, 26/35 kV (Al conductor derated)

Current rating buried (20 °C)

370 A​

direct buried, 3-core

Current rating in conduit (30 °C)

350 A​

3-core

Short-circuit current (1 s, Al, 250 °C)

≈ 12.0 kA (12000 A)

400 mm² Al

Frequency

50/60 Hz AC

—

Reference values: 400 mm² Al at 415 A, 3-phase 35 kV → max balanced load ≈ 25.2 MVA. Voltage drop at 415 A ≈ 41.1 V/km per core (≈0.12% per km at 35 kV).

 

4. Thermal & Mechanical. 90 °C continuous conductor temperature; 250 °C short-circuit (≤ 5 s); 105 °C overload short duration; operating ambient −40~+50 °C; lay ≥ 0 °C. Double steel tape armor provides crush and mechanical protection for direct burial and tray installation.

Temperature Characteristics

 

Property

Value

Max. conductor operating temp.

90 °C (continuous)

Max. short-circuit temp. (≤5 s)

250 °C (Al conductor)

Emergency overload temp.

130 °C

Min. installation ambient temp.

0 °C (PVC sheath); below 0 °C pre-heating required

Service ambient range

−20 °C to +90 °C (with PVC sheath)

Fire survival

Standard (flame retardant single cable)

Fire Performance (YJLV22 — Standard)

Property

Value / Requirement

Flame retardant

IEC 60332-1 (single cable)

Halogen content

Contains halogen (PVC sheath & XLPE)

Smoke density

Standard (non-low-smoke)

Corrosivity

Corrosive (PVC)

Fire survival (circuit integrity)

Not applicable (standard version)

 

5. Installation Practice & Handling. Bend ≥ 15 × OD ≈ 1275 mm fixed. Use MV cold-shrink / heat-shrink terminations rated 8.7/10 kV. Qualified personnel only — MV jointing requires specialized training. DC site test 21 kV before energising. At 6200 kg/km, heavy steel drums require mechanical handling.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 15 × OD → ≈ 1725 mm at Ø115 mm

static installation

Max. pulling tension

12000 N

Al conductor (lower than Cu)

Direct burial

Excellent​ (steel tape armour protects from mechanical damage)

use warning tape

Conduit ID

≥ 1.5 × OD → ≥ 172 mm; use 200 mm or larger

—

Fixing

cable clamps, tray, direct buried

heavy-duty supports required

Impact resistance

High​ (steel tape armour)

—

Water resistance

Good (PVC sheath + armour)

not watertight

UV resistance

Good (black PVC, outdoor rated)

—

Termination note

Al conductors require Al-compatible lugs​ (bimetallic Cu/Al or Al compression lugs) + anti-oxidation compound; requires 35 kV class terminations

strip length 40–45 mm per core

 

 

6. Typical Service Applications. Medium-voltage power distribution, transformer feeders (10 kV side), industrial substations, urban grid, wind/solar farm collector circuits, mining plant power — buried, duct, tray, or trench.

 

3x400mm2 Medium Voltage Cable  XLPE Armored  XLPE Wire 26KV 35kV

 

7. Testing & QA Regime. Routine: conductor DC resistance, 21 kV AC / 5 min withstand, partial discharge ≤ 10 pC at 12 kV, insulation resistance. Type: impulse voltage 75 kV, tan δ at 90 °C, bending test, heating cycle, dimensional check.

 

Cable Parameters

 

YJLV22-3×400 mm² (26/35 kV) — Medium-Voltage XLPE Insulated Steel-Tape Armored Aluminum Power Cable — Full Parameter Sheet 
Medium-voltage power cable · Al conductor / XLPE insulation / Cu tape screen / inner PVC / double steel tape armor (22) / outer PVC · 3×400 mm² · 8.7/10 kV · 90 °C · GB/T 12701 / IEC 60840 · finished Ø ≈ 85 mm
Section Parameter Value Unit Remarks / Standard
01 · Identification
  Cable type YJLV22 — XLPE insulated, steel tape armored, PVC sheathed, Al conductor — MV power distribution
  Rated voltage (U0/U) 8.7/10 (Um=12) kV Medium-voltage power
  Number of cores 3 × 400 — 3-phase (L1/L2/L3)
  Conductor material Aluminum (alloy 1370) — Class 2 compacted per GB/T 3956
  Insulation material XLPE (cross-linked polyethylene) — 90 °C rated, semi-conducting screen
  Armor type Double steel tape (22) — Mechanical / crush protection
  Outer sheath material PVC (ST2), black — UV / weather protection
  Standard GB/T 12701 / IEC 60840 — MV XLPE cable
  Shielding Cu tape screen over insulation — Corona / partial discharge control
02 · Conductor (Aluminum)
  Conductor type Compacted stranded aluminum — Class 2 per GB/T 3956
  Conductor area 3 × 400 mm² 3-phase power
  Stranding construction 61 × 2.85 mm (approx.) — Compacted round
  DC resistance @ 20 °C ≤ 0.124 Ω/km Al 400 mm² max per GB/T 3956
  Conductor screen Extruded semi-conducting — Stress control at conductor
  Conductor weight per km ≈ 3240 kg/km 3×400 Al
03 · Insulation & Screening
  Insulation type XLPE (cross-linked polyethylene) — 90 °C rated
  Insulation thickness ≈ 5.5 mm 8.7/10 kV level
  Insulation screen Extruded semi-conducting + Cu tape — Cu tape ≈ 0.1 mm
  Inner sheath (bedding) PVC ≈ 1.8 Over cored assembly
  Steel tape armor Double galvanized steel tape ≈ 2×0.5 22 armor
  Outer PVC sheath PVC ST2, black ≈ 2.5 UV / weather resistant
  Finished outer diameter ≈ 85 mm Overall
04 · Electrical
  Rated voltage (U0/U) 8.7/10 kV Medium voltage
  Max system voltage (Um) 12 kV Temporary overvoltage
  DC resistance @ 20 °C ≤ 0.124 Ω/km Al 400 mm²
  Insulation resistance ≥ 1000 MΩ·km XLPE — very high
  Routine test voltage (AC) 21 kV / 5 min — Power-frequency withstand
  Partial discharge test ≤ 10 pC at 12 kV — MV cable requirement
  Capacitance ≈ 0.22 μF/km XLPE MV
  Dielectric loss (tan δ) ≤ 0.0004 at 90 °C — MV quality
05 · Thermal
  Max continuous conductor temp. 90 °C XLPE rated
  Short-circuit temp. 250 °C Max 5 s duration
  Overload temp. 105 °C Short duration
  Ambient operating range -40 ~ +50 °C Outdoor / buried
  Laying temperature ≥ 0 °C Pre-heat below 0 °C
06 · Mechanical
  Min bending radius (fixed) ≥ 15 × OD ≈ 1275 mm Armed MV cable
  Min bending radius (flexed) ≥ 20 × OD ≈ 1700 mm Repeated flexing
  Crush resistance Good — Steel tape armor
  Tensile strength Per GB/T 12701 — Installation pull
07 · Ampacity
  Air ampacity (3×400 Al) ≈ 410 A 25 °C ambient (est.)
  Buried ampacity ≈ 380 A Direct burial, 25 °C soil
  Free air current ≈ 450 A Open tray
08 · Installation
  Laying methods Tray, direct burial, duct, trench — MV distribution
  Terminations MV cold-shrink / heat-shrink terminations — 26/35 kV rated
  Joints MV straight joints / branch joints — 26/35 kV rated
  Special tools MV jointing kits, torque wrenches — Qualified personnel only
09 · Packing
  Standard supply length 500 m / drum m HV cable on steel drums
  Reel / packing type Steel drum, sealed ends — Ends must be sealed
  Surface marking YJLV22, 3×400, 8.7/10kV, GB/T 12701, metre marks — Continuous printing
  Storage conditions Dry, indoor, sealed ends — Protect from moisture
10 · Applications
  Typical use MV power distribution, transformer feeders, industrial substations, urban grid, wind/solar farm collector circuits   High-voltage power
  Max system voltage 12 kV (Um) 26/35 kV rated
  Application level Medium voltage —  Distribution grid

 

Cable Test Parameters

 

Test Parameters — YJLV22-3×400 mm² (26/35 kV)
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance GB/T 3956, 20 °C ≤ 0.124 Ω/km (Al 400 mm²) Routine
2 Power-frequency withstand 21 kV AC, 5 min No breakdown Routine
3 Partial discharge test 12 kV, 5 min ≤ 10 pV Routine
4 Insulation resistance 5000 V DC ≥ 1000 MΩ·km Routine
5 Dielectric loss (tan δ) 90 °C, U0 voltage ≤ 0.0004 Type
6 Impulse voltage test 75 kV lightning impulse, 10 shots No breakdown Type
7 Bending test 15× OD, 3 cycles No damage Type
8 Dimensional check Micrometer / caliper OD ≈ 85 mm, XLPE ≈ 5.5 mm Routine
9 Heating cycle test 90 °C ↔ ambient, 10 cycles No damage Type
10 Torsion / armor check Visual + dimensional Steel tape intact Routine
11 Conductor continuity Per GB/T 3956 All 3 cores continuous Routine
12 Sheath thickness Micrometer PVC ≥ 2.5 mm Routine

 

Cable Cross Section Structure

 

3x400mm2 Medium Voltage Cable  XLPE Armored  XLPE Wire 26KV 35kV

 

YJLV22-3×400 mm² (26/35 kV) — Cross-Section Construction Diagram (Schematic)
MV power cable: Al conductors → XLPE insulation → Cu tape screen → inner PVC → double steel tape armor (22) → outer PVC · 8.7/10 kV · 90 °C · finished Ø ≈ 85 mm
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductors (×3) Compacted stranded aluminum, Class 2, 3 × 400 mm² — ≈ 24 R ≤ 0.124 Ω/km
2 Insulation screen Extruded semi-conducting + Cu tape ≈ 0.1 (Cu tape) — Partial discharge control
3 XLPE insulation Cross-linked polyethylene ≈ 5.5 ≈ 35 90 °C rated, 8.7/10 kV
4 Inner sheath (bedding) PVC over cored assembly ≈ 1.8 ≈ 72 Bed over cores
5 Steel tape armor (22) Double galvanized steel tape ≈ 2×0.5 ≈ 78 Mechanical / crush protection
6 Outer PVC sheath PVC ST2, black, UV-resistant ≈ 2.5 ≈ 85 (finished) Weather / UV protection
Key Dimensions & Properties (expanded)
Finished cable diameter ≈ 85 mm Overall    
Approx. cable mass ≈ 6200 kg/km Al conductors + XLPE + armor + PVC    
Nominal voltage rating 8.7/10 kV Medium-voltage power    
Max system voltage (Um) 12 kV Temporary overvoltage    
Max continuous conductor temp. 90 °C XLPE rated    
Short-circuit temp. 250 °C Max 5 s    
Min bending radius (fixed) ≥ 15 × OD ≈ 1275 mm Armed MV cable    
DC resistance @ 20 °C ≤ 0.124 Ω/km Al 400 mm²    
Routine test voltage (AC) 21 kV / 5 min — Power-frequency withstand    
Partial discharge ≤ 10 pC at 12 kV — MV requirement    
Air ampacity @ 25 °C ≈ 410 A 3 cores loaded (est.)    
Buried ampacity ≈ 380 A Direct burial    
Armor type Double steel tape (22) — Mechanical protection    
Conductor material Aluminum — Cost-effective MV    
Schematic — not to exact scale. Finished Ø ≈ 85 mm and weight ≈ 6200 kg/km from cross-referenced industry samples. YJLV22-3×400 is a medium-voltage (8.7/10 kV) XLPE-insulated, steel-tape-armored, aluminum-conductor power cable. Unlike NG-A(BTLY) 4×35+1×16 (low-voltage 0.6/1 kV fire-resistant cable, mica tape insulation, aluminum tube sheath, 750 °C fire-rated, 90 °C, 2450 kg/km), YJLV22 is a medium-voltage power distribution cable: 8.7/10 kV rated, XLPE insulation (5.5 mm thick), copper tape screen for partial discharge control, double steel tape armor for mechanical protection, and aluminum conductors for cost-effective long-distance power transmission. This is not a fire-resistant cable — it is a standard MV distribution cable. Values marked (est.) require confirmation against the factory test certificate.

 

Construction Description

 

Construction Description — YJLV22-3×400 mm² (8.7/10 kV MV armored cable)
Layer-by-layer MV power cable: Al conductors / XLPE insulation / Cu tape screen / inner PVC / double steel tape armor / outer PVC · 8.7/10 kV · 90 °C · finished Ø ≈ 85 mm
1. Product Identity & Ratings
YJLV22-3×400 is a medium-voltage (8.7/10 kV) XLPE-insulated, steel-tape-armored, aluminum-conductor power cable built and tested per GB/T 12701 / IEC 60840. It has 3 aluminum conductors (400 mm² each, L1/L2/L3), XLPE insulation with copper tape screening, inner PVC bedding, double steel tape armor, and outer PVC sheath. Rated 90 °C continuous conductor temperature. Unlike NG-A(BTLY) (low-voltage fire-resistant cable, 0.6/1 kV, mica tape, aluminum tube, 750 °C fire-rated), YJLV22 is a standard MV power distribution cable. Finished Ø ≈ 85 mm, mass ≈ 6200 kg/km, steel drums.
2. Aluminum Conductors (3×400)
The 3 conductors use 400 mm² compacted stranded aluminum (R ≤ 0.124 Ω/km). Aluminum is lighter and cheaper than copper, making it the standard for long-distance MV distribution. Each conductor has an extruded semi-conducting screen to control electrical stress at the conductor surface — essential for MV cables to prevent corona and partial discharge.
3. XLPE Insulation & Copper Tape Screen
XLPE (cross-linked polyethylene) insulation ≈ 5.5 mm thick, rated 90 °C continuous. Over the insulation is a semi-conducting layer plus copper tape screen (≈ 0.1 mm) to control the electrical field and prevent partial discharge. This is fundamentally different from NG-A(BTLY)'s mica tape — XLPE is a thermoplastic insulation for MV power, not a fire barrier.
4. Steel Tape Armor (22)
Double galvanized steel tape (≈ 2×0.5 mm) is applied over the inner PVC bedding. The armor provides crush and mechanical protection for direct burial and tray installation. The '22' designation means: inner PVC bedding + double steel tape armor + outer PVC. This is standard for MV cables buried in trenches or ducts.
5. Site Handling & Operational Notes
• Bend radius 15×OD (≈ 1275 mm) fixed — large because it is an armored MV cable.  • Use MV cold-shrink / heat-shrink terminations rated 8.7/10 kV.  • 21 kV AC routine withstand test.  • Partial discharge ≤ 10 pC at 12 kV.  • At 6200 kg/km, supplied on heavy steel drums.  • Store with ends sealed.  • For MV distribution, transformer feeders, industrial substations.

 

8. Standards & Conformity. GB/T 12701 (MV plastic-insulated power cables); IEC 60840 (XLPE MV cables); GB/T 3956 (conductors). Rated 8.7/10 kV (Um = 12 kV).

 

9. Packaging, Storage & Logistics. 500 m per steel drum with sealed ends. Continuous marking: YJLV22, 3×400, 8.7/10 kV, GB/T 12701, metre marks. Store dry, indoor, ends sealed.

 

3x400mm2 Medium Voltage Cable  XLPE Armored  XLPE Wire 26KV 35kV

 

10. Procurement Specification. State "YJLV22-3×400, 8.7/10 kV" + length. Order matching MV terminations/joints. Confirm against factory test certificate (including partial discharge report).

 

11. Cable Industry FAQ.

  • Q1: What is the difference between YJLV22 and NG-A(BTLY)? YJLV22 is a medium-voltage (8.7/10 kV) power distribution cable with XLPE insulation and steel tape armor. NG-A(BTLY) is a low-voltage (0.6/1 kV) fire-resistant cable with mica tape insulation and aluminum tube sheath. Different voltage, different purpose, different construction — YJLV22 distributes MV power; NG-A(BTLY) survives fire.
  • Q2: What does "22" mean? 22 = inner PVC bedding + double steel tape armor + outer PVC sheath. This is standard for cables buried directly or installed in ducts where crush protection is needed.
  • Q3: Why use aluminum conductors instead of copper? Aluminum is ~1/3 the weight and ~1/4 the cost of copper. For long-distance MV distribution where conductor cost dominates, aluminum (YJLV) is the standard. YJV (copper) is used where space or weight is constrained.
  • Q4: What is the difference between YJV22 and YJLV22? YJV22 uses copper conductors; YJLV22 uses aluminum conductors. Same insulation, same armor, same voltage — only the conductor material differs.
  • Q5: Why is there a copper tape screen? At 8.7/10 kV, the electric field at the conductor surface is high. A semi-conducting layer + copper tape screen equalizes the field and prevents corona and partial discharge — essential for MV cable reliability.
  • Q6: What is partial discharge? Tiny electrical sparks that occur inside the insulation at defects. MV cables must have ≤ 10 pC at rated voltage to ensure long life. Excessive partial discharge leads to insulation breakdown.
  • Q7: Can YJLV22 be used outdoors? Yes — the outer PVC sheath is UV-resistant. For direct burial, the steel tape armor provides crush protection. No additional protection needed.
  • Q8: What bending radius is required? 15×OD ≈ 1275 mm for fixed installation. This is much larger than LV cables because the MV insulation is thick and rigid.
  • Q9: What is the routine test voltage? 21 kV AC for 5 minutes — this is 2.4× the rated phase voltage (8.7 kV). This proves the cable has no manufacturing defects.
  • Q10: Can YJLV22 be used for fire pump circuits? No — YJLV22 is not fire-resistant. Fire pump circuits must use mineral-insulated fire cables (BTTRZ/BTLY). YJLV22 is for standard MV power distribution.
  • Q11: How is the cable terminated? MV cold-shrink or heat-shrink terminations rated 8.7/10 kV. The termination must carefully strip the XLPE insulation, insulation screen, and conductor screen in the correct order. Only trained personnel should terminate MV cables.