logo
Anhui Tongdu International Trade Co., Ltd.
Online Service

Online Service

Contact Person
+86 19056002718
WeChat QR Code
Follow Us
No Products Found Matching Your Search Criteria:

"commercial medium voltage power cable polyvinyl chloride pvc or low smoke zero halogen lszh"

Please try a different search term or browse our product categories.

Recommend Other Products
Quality Black BV 2.5mm2 Solid Copper Core Cu PVC Wire For Conduit Installation factory

Black BV 2.5mm2 Solid Copper Core Cu PVC Wire For Conduit Installation

Black BV 2.5mm² Solid Copper Conductor PVC Wire for Conduit Installation Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain copper conductor (solid or ...

Quality White Copper Building Wire  PVC Insulated Single Core Household Electrical Cable factory

White Copper Building Wire PVC Insulated Single Core Household Electrical Cable

BV 2.5mm2 White PVC Insulated Single Core Copper Building Wire 450/750V Household Electrical Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain ...

Quality 3x240mm2 Flexible Medium Voltage Cable 8.7kV 15kV 3 Core Cable factory

3x240mm2 Flexible Medium Voltage Cable 8.7kV 15kV 3 Core Cable

XLPE Medium Voltage Aluminum Cable YJLV22 3x240mm2 8.7/15kV Armored 3 Core Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor​ (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 ...

Quality 3x120mm2 Medium Voltage Power Cable 8.7kV 15kV Aluminum Mc Cable factory

3x120mm2 Medium Voltage Power Cable 8.7kV 15kV Aluminum Mc Cable

Industrial Main Aluminum Cable YJLV22 3x120mm² 8.7/15kV Armored MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor​ (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated ...

Quality Aluminum Concentric Neutral Mv Cable 3x95mm2 3 Core Aluminium Armoured Cable factory

Aluminum Concentric Neutral Mv Cable 3x95mm2 3 Core Aluminium Armoured Cable

Main Distribution Aluminum Cable YJLV22 3x95mm² 8.7/15kV Armored MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor​ (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...

Quality Mega Industrial Main Cable YJV22 3x120mm² 8.7/15kV Armored MV XLPE factory

Mega Industrial Main Cable YJV22 3x120mm² 8.7/15kV Armored MV XLPE

Mega Industrial Main Cable YJV22 3x120mm² 8.7/15kV Armored MV XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV; U...

Quality 3 Core Armored MV Cable YJV22 3x50mm² 8.7/10kV 8.7/15kV XLPE Power Cable factory

3 Core Armored MV Cable YJV22 3x50mm² 8.7/10kV 8.7/15kV XLPE Power Cable

3 Core Armored MV Cable YJV22 3x50mm² 8.7/10kV 8.7/15kV XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...

Quality BTLY  Fire Rated Cable 4x35mm2 + 1x16mm2  Aluminum Sheath Cable For Emergency factory

BTLY Fire Rated Cable 4x35mm2 + 1x16mm2 Aluminum Sheath Cable For Emergency

NG-A BTLY 4x35+1x16mm2 Mineral Insulated Fire Resistant Aluminum Sheath Cable for Emergency Cable Designation & Meaning Code Meaning NG-A New Generation A-class fire-resistant (Chinese designation) (BTLY) Building wire, Thin copper conductor, Lightweight Y— alternative naming convention indicating: ...