YJV22 Medium Voltage Power Cable 3x150mm2 Copper Mv Armoured Cable 15kV
Product Summary
Product Details
yjv22 medium voltage power cable
,medium voltage power cable 3x150mm2
,mv armoured cable 15kv
Product Description
YJV22 3x150mm² Copper XLPE Armored MV Cable 8.7/15kV Reliable Underground Power
Cable Designation & Meaning
|
Code |
Meaning |
|---|---|
|
YJ |
XLPE (cross-linked polyethylene) insulation |
|
V |
PVC outer sheath |
|
22 |
Steel tape armoured (double steel tape) |
|
3×150 mm² |
Three cores, each 150 mm² copper |
Construction: Copper conductor, XLPE insulation, semi-con screens, steel tape armour, PVC sheath, three-core medium voltage power cable.


YJV22-3×150 mm² (8.7/15 kV) — Compact Medium-Voltage XLPE Insulated Steel-Tape Armored Copper Power Cable — Specification & Engineering Data
1. Overview & Ratings. YJV22-3×150 — compact medium-voltage XLPE-insulated, double steel-tape armored, PVC-sheathed copper-conductor power cable, three 150 mm² compacted copper conductors (L1/L2/L3), rated 8.7/15 kV (Um = 17.5 kV), 50 Hz; built and tested per GB/T 12701 / IEC 60840. Copper conductors deliver higher current density in a smaller footprint than the aluminum 400 mm² version. Ø ≈ 62 mm, ≈ 5800 kg/km, steel drums.
2. Construction Stack (Conductor → Outer).
| Layer | Build | Wall | Diameter |
|---|---|---|---|
| Conductors (×3) | Compacted stranded Cu, Class 2, 3×150 mm² | — | ≈ 14.5 mm |
| Conductor screen | Extruded semi-conducting | — | — |
| XLPE insulation | Cross-linked polyethylene | ≈ 4.5 mm | ≈ 24 mm |
| Insulation screen | Semi-conducting + Cu tape | ≈ 0.1 mm Cu | — |
| Inner PVC bedding | PVC over cored assembly | ≈ 1.5 mm | ≈ 55 mm |
| Steel tape armor (22) | Double galvanized steel tape | ≈ 2×0.5 mm | ≈ 58 mm |
| Outer PVC sheath | PVC ST2, black, UV-resistant | ≈ 2.2 mm | ≈ 62 mm (finished) |
3. Electrical Characteristics. R ≤ 0.124 Ω/km at 20 °C (Cu 150 mm²); routine test 25 kV AC / 5 min; partial discharge ≤ 10 pC at 12 kV; insulation resistance ≥ 1500 MΩ·km; capacitance ≈ 0.20 μF/km; tan δ ≤ 0.0004 at 90 °C. Reference ampacity ≈ 265 A (free air, 25 °C).
Insulation Data
|
Property |
Value |
|---|---|
|
Material |
XLPE (cross-linked polyethylene) |
|
Nominal thickness |
4.5 mm (8.7/15 kV class) |
|
Long-term service temp. |
90 °C |
|
Short-circuit temp. (≤5 s) |
250 °C (Cu conductor limit per IEC 60228) |
|
Emergency overload temp. |
130 °C |
|
Routine test voltage (AC, 5 min) |
30.5 kV (for 8.7/15 kV) |
|
Type-test voltage (AC) |
45 kV (for 8.7/15 kV) |
|
Partial discharge test |
≤ 10 pC at 1.5 U₀ (13.05 kV) |
|
Tan δ (dissipation factor) |
≤ 0.004 at 20 °C |
Electrical Parameters
|
Parameter |
Value |
Note |
|---|---|---|
|
Rated voltage U₀/U |
8.7 / 15 kV (typical) or 6.35 / 11 kV |
GB/T 12706.2 / IEC 60502-2 |
|
Max. system voltage Uₘ |
17.5 kV (for 15 kV class) |
— |
|
Test voltage AC (5 min) |
30.5 kV |
Routine test (8.7/15 kV) |
|
DC resistance @20 °C |
≤ 0.124 Ω/km |
GB/T 3956 Class 2 Cu max, 150 mm² |
|
AC resistance @90 °C (est.) |
≈ 0.158 Ω/km |
per core |
|
Capacitance (approx.) |
≈ 0.24 µF/km |
core to screen |
|
Inductive reactance (approx.) |
≈ 0.10 Ω/km |
at 50 Hz, 3-core armoured |
|
Current rating in air (30 °C) |
310 A |
3-core, 8.7/15 kV |
|
Current rating buried (20 °C) |
275 A |
direct buried, 3-core |
|
Current rating in conduit (30 °C) |
260 A |
3-core |
|
Short-circuit current (1 s, Cu, 250 °C) |
≈ 15.0 kA (15000 A) |
150 mm² Cu |
|
Frequency |
50/60 Hz AC |
— |
Reference values: 150 mm² Cu at 310 A, 3-phase 10 kV → max balanced load ≈ 5.4 MVA. Voltage drop at 310 A ≈ 49.0 V/km per core (≈0.49% per km at 10 kV).
4. Thermal & Mechanical. 90 °C continuous conductor temperature; 250 °C short-circuit (≤ 5 s); 105 °C overload short duration; operating ambient −40~+50 °C; lay ≥ 0 °C. Double steel tape armor provides crush and mechanical protection for direct burial and tray installation.
Temperature Characteristics
|
Property |
Value |
|---|---|
|
Max. conductor operating temp. |
90 °C (continuous) |
|
Max. short-circuit temp. (≤5 s) |
250 °C (Cu conductor) |
|
Emergency overload temp. |
130 °C |
|
Min. installation ambient temp. |
0 °C (PVC sheath); below 0 °C pre-heating required |
|
Service ambient range |
−20 °C to +90 °C (with PVC sheath) |
|
Fire survival |
Standard (flame retardant single cable) |
Fire Performance (YJV22 — Standard)
|
Property |
Value / Requirement |
|---|---|
|
Flame retardant |
IEC 60332-1 (single cable, passes) |
|
Halogen content |
Contains halogen (PVC sheath & XLPE) |
|
Smoke density |
Standard (non-low-smoke) |
|
Corrosivity |
Corrosive (PVC) |
|
Fire survival (circuit integrity) |
Not applicable (standard version); use NH-YJV22 for circuit integrity |
5. Installation Practice & Handling. Bend ≥ 15 × OD ≈ 930 mm fixed. Use MV cold-shrink / heat-shrink terminations rated 8.7/15 kV. Qualified personnel only — MV jointing requires specialized training. At 5800 kg/km, heavy steel drums require mechanical handling. The compact Ø62 mm makes it suitable for restricted spaces.
Mechanical & Installation Parameters
|
Parameter |
Value |
Remarks |
|---|---|---|
|
Minimum bending radius |
≥ 15 × OD → ≈ 990 mm at Ø66 mm |
static installation |
|
Max. pulling tension |
15000 N |
Cu conductor, use proper pulling grips |
|
Direct burial |
Excellent (steel tape armour protects from mechanical damage) |
use warning tape |
|
Conduit ID |
≥ 1.5 × OD → ≥ 99 mm; use 100 mm, 125 mm or 150 mm |
— |
|
Fixing |
cable clamps, tray, direct buried |
— |
|
Impact resistance |
High (steel tape armour) |
— |
|
Water resistance |
Good (PVC sheath + armour) |
not watertight; use lead-sheathed for submerged |
|
UV resistance |
Good (black PVC, outdoor rated) |
— |
|
Termination note |
Cu conductors — standard compression lugs or mechanical lugs |
strip length 25–30 mm per core |
6. Typical Service Applications. Compact MV power distribution, building MV risers, industrial substations, wind/solar farm collector circuits, urban grid secondary feeders — where space is constrained but 8.7/15 kV rating is required.

7. Testing & QA Regime. Routine: conductor DC resistance, 25 kV AC / 5 min withstand, partial discharge ≤ 10 pC at 12 kV, insulation resistance. Type: impulse voltage 95 kV, tan δ at 90 °C, bending test, heating cycle, dimensional check.
Cable Parameters
| YJV22-3×150 mm² (8.7/15 kV) — Medium-Voltage XLPE Insulated Steel-Tape Armored Copper Power Cable — Full Parameter Sheet | ||||
| Compact MV cable · Cu conductor / XLPE insulation / Cu tape screen / inner PVC / double steel tape armor (22) / outer PVC · 3×150 mm² · 8.7/15 kV · 90 °C · GB/T 12701 / IEC 60840 · finished Ø ≈ 62 mm | ||||
| Section | Parameter | Value | Unit | Remarks / Standard |
| 01 · Identification | ||||
| Cable type | YJV22 — XLPE insulated, steel tape armored, PVC sheathed, Cu conductor | — | MV power distribution | |
| Rated voltage (U0/U) | 8.7/15 (Um=17.5) | kV | Medium-voltage power | |
| Number of cores | 3 × 150 | — | 3-phase (L1/L2/L3) | |
| Conductor material | Annealed copper | — | Class 2 compacted per GB/T 3956 | |
| Insulation material | XLPE (cross-linked polyethylene) | — | 90 °C rated, semi-conducting screen | |
| Armor type | Double steel tape (22) | — | Mechanical / crush protection | |
| Outer sheath material | PVC (ST2), black | — | UV / weather protection | |
| Standard | GB/T 12701 / IEC 60840 | — | MV XLPE cable | |
| Shielding | Cu tape screen over insulation | — | Corona / partial discharge control | |
| 02 · Conductor (Copper) | ||||
| Conductor type | Compacted stranded copper | — | Class 2 per GB/T 3956 | |
| Conductor area | 3 × 150 | mm² | 3-phase power | |
| Stranding construction | 30 × 2.52 mm (approx.) | — | Compacted round | |
| DC resistance @ 20 °C | ≤ 0.124 | Ω/km | Cu 150 mm² max per GB/T 3956 | |
| Conductor screen | Extruded semi-conducting | — | Stress control at conductor | |
| Conductor weight per km | ≈ 4050 | kg/km | 3×150 Cu | |
| 03 · Insulation & Screening | ||||
| Insulation type | XLPE (cross-linked polyethylene) | — | 90 °C rated | |
| Insulation thickness | ≈ 4.5 | mm | 8.7/15 kV level | |
| Insulation screen | Extruded semi-conducting + Cu tape | — | Cu tape ≈ 0.1 mm | |
| Inner sheath (bedding) | PVC | ≈ 1.5 | Over cored assembly | |
| Steel tape armor | Double galvanized steel tape | ≈ 2×0.5 | 22 armor | |
| Outer PVC sheath | PVC ST2, black | ≈ 2.2 | UV / weather resistant | |
| Finished outer diameter | ≈ 62 | mm | Overall | |
| 04 · Electrical | ||||
| Rated voltage (U0/U) | 8.7/15 | kV | Medium voltage | |
| Max system voltage (Um) | 17.5 | kV | Temporary overvoltage | |
| DC resistance @ 20 °C | ≤ 0.124 | Ω/km | Cu 150 mm² | |
| Insulation resistance | ≥ 1500 | MΩ·km | XLPE — very high | |
| Routine test voltage (AC) | 25 kV / 5 min | — | Power-frequency withstand | |
| Partial discharge test | ≤ 10 pC at 12 kV | — | MV cable requirement | |
| Capacitance | ≈ 0.20 | μF/km | XLPE MV | |
| Dielectric loss (tan δ) | ≤ 0.0004 at 90 °C | — | MV quality | |
| 05 · Thermal | ||||
| Max continuous conductor temp. | 90 | °C | XLPE rated | |
| Short-circuit temp. | 250 | °C | Max 5 s duration | |
| Overload temp. | 105 | °C | Short duration | |
| Ambient operating range | -40 ~ +50 | °C | Outdoor / buried | |
| Laying temperature | ≥ 0 | °C | Pre-heat below 0 °C | |
| 06 · Mechanical | ||||
| Min bending radius (fixed) | ≥ 15 × OD ≈ 930 | mm | Armed MV cable | |
| Min bending radius (flexed) | ≥ 20 × OD ≈ 1240 | mm | Repeated flexing | |
| Crush resistance | Good | — | Steel tape armor | |
| Tensile strength | Per GB/T 12701 | — | Installation pull | |
| 07 · Ampacity | ||||
| Air ampacity (3×150 Cu) | ≈ 265 | A | 25 °C ambient (est.) | |
| Buried ampacity | ≈ 245 | A | Direct burial, 25 °C soil | |
| Free air current | ≈ 290 | A | Open tray | |
| 08 · Installation | ||||
| Laying methods | Tray, direct burial, duct, trench | — | MV distribution | |
| Terminations | MV cold-shrink / heat-shrink terminations | — | 8.7/15 kV rated | |
| Joints | MV straight joints / branch joints | — | 8.7/15 kV rated | |
| Special tools | MV jointing kits, torque wrenches | — | Qualified personnel only | |
| 09 · Packing | ||||
| Standard supply length | 500 m / drum | m | MV cable on steel drums | |
| Reel / packing type | Steel drum, sealed ends | — | Ends must be sealed | |
| Surface marking | YJV22, 3×150, 8.7/15kV, GB/T 12701, metre marks | — | Continuous printing | |
| Storage conditions | Dry, indoor, sealed ends | — | Protect from moisture | |
| 10 · Applications | ||||
| Typical use | MV power distribution, compact transformer feeders, industrial substations, urban grid, building MV risers | — | Medium-voltage power | |
| Max system voltage | 17.5 | kV (Um) | 8.7/15 kV rated | |
| Application level | Medium voltage | — | Distribution grid | |
Test Parameters
| Test Parameters — YJV22-3×150 mm² (8.7/15 kV) | ||||
| No. | Test Item | Test Condition / Method | Requirement | Type |
| 1 | Conductor DC resistance | GB/T 3956, 20 °C | ≤ 0.124 Ω/km (Cu 150 mm²) | Routine |
| 2 | Power-frequency withstand | 25 kV AC, 5 min | No breakdown | Routine |
| 3 | Partial discharge test | 12 kV, 5 min | ≤ 10 pC | Routine |
| 4 | Insulation resistance | 5000 V DC | ≥ 1500 MΩ·km | Routine |
| 5 | Dielectric loss (tan δ) | 90 °C, U0 voltage | ≤ 0.0004 | Type |
| 6 | Impulse voltage test | 95 kV lightning impulse, 10 shots | No breakdown | Type |
| 7 | Bending test | 15× OD, 3 cycles | No damage | Type |
| 8 | Dimensional check | Micrometer / caliper | OD ≈ 62 mm, XLPE ≈ 4.5 mm | Routine |
| 9 | Heating cycle test | 90 °C ↔ ambient, 10 cycles | No damage | Type |
| 10 | Torsion / armor check | Visual + dimensional | Steel tape intact | Routine |
| 11 | Conductor continuity | Per GB/T 3956 | All 3 cores continuous | Routine |
| 12 | Sheath thickness | Micrometer | PVC ≥ 2.2 mm | Routine |
Cable Cross Section Structure

| YJV22-3×150 mm² (8.7/15 kV) — Cross-Section Construction Diagram (Schematic) | |||||
| Compact MV power cable: Cu conductors → XLPE insulation → Cu tape screen → inner PVC → double steel tape armor (22) → outer PVC · 8.7/15 kV · 90 °C · finished Ø ≈ 62 mm | |||||
| No. | Layer | Material / Construction | Nominal Thickness (mm) | Diameter (mm) | Function / Remarks |
| 1 | Conductors (×3) | Compacted stranded copper, Class 2, 3 × 150 mm² | — | ≈ 14.5 | R ≤ 0.124 Ω/km |
| 2 | Insulation screen | Extruded semi-conducting + Cu tape | ≈ 0.1 (Cu tape) | — | Partial discharge control |
| 3 | XLPE insulation | Cross-linked polyethylene | ≈ 4.5 | ≈ 24 | 90 °C rated, 8.7/15 kV |
| 4 | Inner sheath (bedding) | PVC over cored assembly | ≈ 1.5 | ≈ 55 | Bed over cores |
| 5 | Steel tape armor (22) | Double galvanized steel tape | ≈ 2×0.5 | ≈ 58 | Mechanical / crush protection |
| 6 | Outer PVC sheath | PVC ST2, black, UV-resistant | ≈ 2.2 | ≈ 62 (finished) | Weather / UV protection |
| Key Dimensions & Properties (expanded) | |||||
| Finished cable diameter | ≈ 62 | mm | Overall | ||
| Approx. cable mass | ≈ 5800 | kg/km | Cu conductors + XLPE + armor + PVC | ||
| Nominal voltage rating | 8.7/15 | kV | Medium-voltage power | ||
| Max system voltage (Um) | 17.5 | kV | Temporary overvoltage | ||
| Max continuous conductor temp. | 90 | °C | XLPE rated | ||
| Short-circuit temp. | 250 | °C | Max 5 s | ||
| Min bending radius (fixed) | ≥ 15 × OD ≈ 930 | mm | Armed MV cable | ||
| DC resistance @ 20 °C | ≤ 0.124 | Ω/km | Cu 150 mm² | ||
| Routine test voltage (AC) | 25 kV / 5 min | — | Power-frequency withstand | ||
| Partial discharge | ≤ 10 pC at 12 kV | — | MV requirement | ||
| Air ampacity @ 25 °C | ≈ 265 | A | 3 cores loaded (est.) | ||
| Buried ampacity | ≈ 245 | A | Direct burial | ||
| Armor type | Double steel tape (22) | — | Mechanical protection | ||
| Conductor material | Copper | — | High current density | ||
| Schematic — not to exact scale. Finished Ø ≈ 62 mm and weight ≈ 5800 kg/km from cross-referenced industry samples. YJV22-3×150 is a compact medium-voltage (8.7/15 kV) XLPE-insulated, steel-tape-armored, copper-conductor power cable. Compared to YJLV22-3×400 (8.7/10 kV, aluminum conductor, 400 mm², Ø85 mm, 6200 kg/km, 410 A), this cable uses copper conductors (higher current density, smaller footprint), a higher voltage rating (8.7/15 kV vs 8.7/10 kV), and a smaller overall diameter (Ø62 mm vs Ø85 mm). It is designed for compact MV distribution where space is constrained. Values marked (est.) require confirmation against the factory test certificate. | |||||
Construction Description
| Construction Description — YJV22-3×150 mm² (8.7/15 kV compact MV armored cable) | |||
| Layer-by-layer MV power cable: Cu conductors / XLPE insulation / Cu tape screen / inner PVC / double steel tape armor / outer PVC · 8.7/15 kV · 90 °C · finished Ø ≈ 62 mm | |||
| 1. Product Identity & Ratings | |||
| YJV22-3×150 is a compact medium-voltage (8.7/15 kV) XLPE-insulated, steel-tape-armored, copper-conductor power cable built and tested per GB/T 12701 / IEC 60840. It has 3 copper conductors (150 mm² each, L1/L2/L3), XLPE insulation with copper tape screening, inner PVC bedding, double steel tape armor, and outer PVC sheath. Rated 90 °C continuous. Compared to YJLV22-3×400 (aluminum, 400 mm², 8.7/10 kV, Ø85 mm), this cable uses copper for higher current density in a smaller footprint. Finished Ø ≈ 62 mm, mass ≈ 5800 kg/km, steel drums. | |||
| 2. Copper Conductors (3×150) | |||
| The 3 conductors use 150 mm² compacted stranded copper (R ≤ 0.124 Ω/km). Copper has ~60% higher conductivity than aluminum, so 150 mm² Cu carries similar current to ~240 mm² Al. This makes the cable more compact — Ø62 mm vs Ø85 mm for the aluminum 400 mm² version. Copper is preferred where installation space is limited. | |||
| 3. XLPE Insulation & Copper Tape Screen | |||
| XLPE insulation ≈ 4.5 mm thick, rated 90 °C. The 8.7/15 kV rating means U0 = 8.7 kV phase-to-ground, U = 15 kV phase-to-phase. Over the insulation is a semi-conducting layer plus copper tape screen (≈ 0.1 mm) to control the electrical field and prevent partial discharge. Routine test voltage is 25 kV / 5 min. | |||
| 4. Steel Tape Armor (22) | |||
| Double galvanized steel tape (≈ 2×0.5 mm) over inner PVC bedding provides crush protection. The '22' designation means inner PVC + double steel tape + outer PVC. This is standard for MV cables buried in trenches or ducts. The armor does not carry current — it is purely mechanical protection. | |||
| 5. Site Handling & Operational Notes | |||
| • Bend radius 15×OD (≈ 930 mm) fixed. • Use MV cold-shrink / heat-shrink terminations rated 8.7/15 kV. • 25 kV AC routine withstand test. • Partial discharge ≤ 10 pC at 12 kV. • At 5800 kg/km, supplied on heavy steel drums. • Store with ends sealed. • For compact MV distribution, building risers, industrial substations. |
8. Standards & Conformity. GB/T 12701 (MV plastic-insulated power cables); IEC 60840 (XLPE MV cables); GB/T 3956 (conductors). Rated 8.7/15 kV (Um = 17.5 kV).
9. Packaging, Storage & Logistics. 500 m per steel drum with sealed ends. Continuous marking: YJV22, 3×150, 8.7/15 kV, GB/T 12701, metre marks. Store dry, indoor, ends sealed.

10. Procurement Specification. State "YJV22-3×150, 8.7/15 kV" + length. Order matching MV terminations/joints rated 8.7/15 kV. Confirm against factory test certificate (including partial discharge report).
11. Cable Industry FAQ.
- Q1: What is the difference between YJV22-3×150 (8.7/15 kV) and YJLV22-3×400 (8.7/10 kV)? YJV22 uses copper conductors (150 mm², Ø62 mm, 265 A, 25 kV test), while YJLV22 uses aluminum conductors (400 mm², Ø85 mm, 410 A, 21 kV test). Copper has higher conductivity per area, so 150 mm² Cu carries similar current to ~240 mm² Al. The 8.7/15 kV rating is also higher than 8.7/10 kV.
- Q2: When do I choose 8.7/15 kV instead of 8.7/10 kV? 8.7/15 kV is used in systems where the phase-to-phase voltage can reach 15 kV (e.g., 10 kV nominal with high system voltage). The higher rating provides extra margin for temporary overvoltages.
- Q3: Why use copper instead of aluminum? Copper has ~60% higher conductivity than aluminum, so a copper 150 mm² cable is physically smaller (Ø62 mm) than an aluminum 400 mm² cable (Ø85 mm) while carrying similar current. Choose copper where space is limited; choose aluminum where long-distance cost matters.
- Q4: What does "22" mean? 22 = inner PVC bedding + double steel tape armor + outer PVC sheath. Standard for buried or duct-installed MV cables.
- Q5: What is the routine test voltage for 8.7/15 kV? 25 kV AC for 5 minutes — higher than the 8.7/10 kV version (21 kV), because the insulation is thicker (4.5 mm vs 5.5 mm for the 10 kV class, but rated higher U0).
- Q6: What is partial discharge? Tiny electrical sparks inside the insulation at defects. MV cables must have ≤ 10 pC at rated voltage to ensure long life. Excessive partial discharge leads to insulation breakdown.
- Q7: Can YJV22 be used outdoors? Yes — the outer PVC sheath is UV-resistant. For direct burial, the steel tape armor provides crush protection.
- Q8: What bending radius is required? 15×OD ≈ 930 mm for fixed installation. Smaller than the 400 mm² version (1275 mm) because the overall diameter is smaller.
- Q9: What is the impulse voltage test level? 95 kV lightning impulse — higher than the 8.7/10 kV version (75 kV), because the 8.7/15 kV insulation must withstand higher surge voltages.
- Q10: Can YJV22 be used for fire pump circuits? No — YJV22 is not fire-resistant. Fire pump circuits must use mineral-insulated fire cables (BTTRZ/BTLY). YJV22 is for standard MV power distribution.
- Q11: How is the cable terminated? MV cold-shrink or heat-shrink terminations rated 8.7/15 kV. The termination must carefully strip the XLPE insulation, insulation screen, and conductor screen in the correct order. Only trained personnel should terminate MV cables.