OEM Copper Xlpe Cable 4 Core Heat Resistant Flex 3×50mm2+1×25mm2 For Heavy Duty

OEM Copper Xlpe Cable 4 Core Heat Resistant Flex 3×50mm2+1×25mm2 For Heavy Duty

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
ZR-YJV 3×50mm²+1×25mm²

Trading Properties

moq
100 meters
payment method
L/C,T/T
supply capacity
10000 meters per month

Product Summary

Flame Retardant Copper Conductor ZR-YJV 3×50mm²+1×25mm² for Heavy-Duty Three Phase Supply Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer ...

Product Details

Highlight:

OEM 4 core heat resistant flex

,

4 core heat resistant flex 900kg/km

,

Heavy Duty copper xlpe cable

Phase conductor (×3):
Bare Annealed Copper, Class 2 Stranded, 19×∅1.78 Mm (also 7×∅3.00 Mm Compact), Conductor Ø ≈ 9.0–9.5 Mm Depending On Compaction
Neutral conductor (×1):
Bare Annealed Copper, Class 2 Stranded, 7×∅2.14 Mm, Conductor Ø ≈ 6.4–6.8 Mm
Phase conductor nominal area:
50 Mm²
Neutral conductor nominal area:
25 Mm²
Number of cores:
4 (3+1)
Phase conductor construction:
Class 2, 19×∅1.78 Mm,IEC 60228 / GB/T 3956
Neutral conductor construction:
Class 2, 7×∅2.14 Mm,IEC 60228 / GB/T 3956
Phase conductor diameter (approx.):
9.0–9.5 Mm
Neutral conductor diameter (approx.):
6.4–6.8 Mm
Insulation (×4):
XLPE
Phase insulation thickness:
1.0 Mm (50 Mm² Class)
Neutral insulation thickness:
0.9 Mm (25 Mm² Class)
Diameter over phase insulated core:
11.0–11.5 Mm
Diameter over neutral insulated core:
8.2–8.6 Mm
Filler / binder:
FR PP Filler + FR Tape
Outer sheath:
Flame-retardant PVC (ZR Grade)
Sheath thickness:
1.6 Mm (GB/T 12706 Multi-core 50–95 Mm² Range)
Overall cable diameter:
21.0 – 25.5 Mm
Design outer diameter:
≈ 23.0 Mm
Approx. weight:
700 – 900 Kg/km
Design weight:
≈ 770 Kg/km

Product Description

Flame Retardant Copper Conductor ZR-YJV 3×50mm²+1×25mm² for Heavy-Duty Three Phase Supply

 

Cable Designation & Meaning

 

Code

Meaning

ZR

Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC).

YJ

XLPE (cross-linked polyethylene) insulation

V

PVC outer sheath — flame-retardant grade, contains halogen (Cl)

0.6/1 kV

Rated voltage U₀/U = 600/1000 V; Uₘ = 1.2 kV

3×50+1×25 mm²

Three phase cores of 50 mm² copper + one reduced neutral core of 25 mm² copper

OEM Copper Xlpe Cable 4 Core Heat Resistant Flex 3×50mm2+1×25mm2 For Heavy Duty

ZR-YJV 3×50+1×25 mm² — Cable Specification & Engineering Data 

1. Overview & Ratings. ZR-YJV 3×50+1×25 is a flame-retarding 3+1-core cable: three 50 mm² copper phase conductors and one 25 mm² copper neutral conductor, XLPE insulation and one ST2 PVC jacket, rated 0.6/1 kV (Um = 1.2 kV), 50 Hz; manufactured and proof-tested to GB/T 12706.1 / IEC 60502-1, stranding to GB/T 3956, ZC fire class to GB/T 19666. Finished diameter ≈ 27.4 mm, mass ≈ 1901 kg/km, supplied in 100 m coils or drums.

 

2. Construction Stack. Conductor → outer jacket:

Layer Build Wall Diameter
Phase conductor (×3) Annealed Cu, Class 2 compact, 7 × 3.00 mm (1+6) each — ≈ 9.00 mm
Neutral conductor (×1) Annealed Cu, Class 2 compact, 7 × 2.14 mm (1+6) — ≈ 6.42 mm
Phase insulation (×3) XLPE 1.0 mm ≈ 11.00 mm
Neutral insulation (×1) XLPE 0.9 mm ≈ 8.22 mm
Core assembly Central neutral + 3 phase cores around + dry filler + binder wrap — ≈ 23.4 mm (calc.)
Outer jacket Flame-retarded PVC, ST2 compound, black 2.0 mm ≈ 27.4 mm (Zhongce 3+1)

 

3. Electrical Ratings. Phase R ≤ 0.387 Ω/km, neutral R ≤ 0.727 Ω/km @ 20 °C; factory proof 3.5 kV AC / 5 min; finished-cable insulation resistance ≥ 36.7 MΩ·km; XLPE volume resistivity ≥ 1×10¹² Ω·cm; capacitance ≤ 0.45 μF/km. Reference current (3 phase cores loaded) ≈ 200 A in air @ 30 °C / 210 A buried @ 25 °C — Zhongce 3+1 unarmored basis.

 

Electrical Parameters

 

Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

Uₘ = 1.2 kV

Test voltage AC (5 min)

3.5 kV

Routine

Type-test voltage

4.0 kV

IEC 60502-1

DC resistance @20 °C (phase, per core)

≤ 0.387 Ω/km

GB/T 3956 max, 50 mm²

DC resistance @20 °C (neutral, per core)

≤ 0.727 Ω/km

GB/T 3956 max, 25 mm²

AC resistance @90 °C (est., phase)

≈ 0.503 Ω/km

per core

AC resistance @90 °C (est., neutral)

≈ 0.946 Ω/km

per core

Current rating in air (30 °C, single circuit, 3-core+1)

≈ 140–160 A

based on 50 mm² phase

Current rating in air (design)

≈ 148 A

apply grouping + ambient correction

Direct buried (20–25 °C, soil 1.0–1.2 K·m/W, 0.7 m)

≈ 160–180 A

common catalogue 165–172 A

Design buried rating

≈ 168 A

soil thermal resistivity correction required

Short-circuit current (1 s, Cu, 250 °C, phase)

≈ 5.0 kA

50 mm² reference

Short-circuit current (1 s, Cu, 250 °C, neutral)

≈ 2.5 kA

25 mm² reference

Frequency

50/60 Hz AC

—

 

4.Cable Parameters & Test Parameters

 

OEM Copper Xlpe Cable 4 Core Heat Resistant Flex 3×50mm2+1×25mm2 For Heavy Duty

 

ZR-YJV 3×50+1×25 mm² — Test & Verification Schedule (GB/T 12706.1 & IEC 60502-1)
Stage Test Item Method / Standard Acceptance Criterion Notes
Routine Phase conductor DC resistance GB/T 3956 (IEC 60228) ≤ 0.387 Ω/km @ 20 °C (50 mm²) Every production length
Routine Neutral conductor DC resistance GB/T 3956 (IEC 60228) ≤ 0.727 Ω/km @ 20 °C (25 mm²) Every production length
Routine Power-frequency withstand GB/T 12706.1 / IEC 60502-1 3.5 kV AC / 5 min, no breakdown Conductor to earth/water
Routine Dimensional inspection GB/T 2951 Phase ins. ≥ 1.0 mm; neutral ins. ≥ 0.9 mm; sheath ≥ 2.0 mm; OD within tolerance Wall & diameter check
Sample XLPE hot-set test GB/T 12706.1 §16.3.13 / GB/T 2951.11 200 ± 3 °C, 15 min, 0.2 MPa: load elongation ≤ 175 %; permanent ≤ 15 % Cross-linking verification
Sample Conductor geometry GB/T 3956 Phase: 7 × 3.00 mm Ø ≈ 9.00; neutral: 7 × 2.14 mm Ø ≈ 6.42 Per batch
Type Single-cable flame test GB/T 18380.12 No flame to upper reference ZR property
Type Bunched flame test — C GB/T 18380.35 Char ≤ 2.5 m; 20 min; ≥ 1.5 L/m Class C
Type Bending test GB/T 12706.1 No damage on specified mandrel Multi-core rule
Post-install DC withstand test Q/GDW 13244.1-2018 2.4 kV DC / 15 min, no breakdown New installations
Optional Insulation resistance @ 20 °C Factory method ≥ 36.7 MΩ·km Not routine under GB/T 12706.1

 

5. Cable Cross Section Structure 

 

OEM Copper Xlpe Cable 4 Core Heat Resistant Flex 3×50mm2+1×25mm2 For Heavy Duty

 

ZR-YJV 3×50+1×25 mm² — Cross-Section Construction Diagram (Schematic)
Layered 3+1 conductor build-up from copper strand to PVC jacket · nominal dimensions per GB/T 12706.1 / IEC 60502-1 · diagram is illustrative, not to scale
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Phase conductor (Cu) × 3 Annealed copper, Class 2 compact strand — 7 wires of 3.00 mm per core (7/3.00, 1+6 layout), nominal area 50 mm² each — ≈ 9.00 (Ø each phase core) Line-current carrying phase conductors; DC resistance capped at 0.387 Ω/km at 20 °C
2 Neutral conductor (Cu) × 1 Annealed copper, Class 2 compact strand — 7 wires of 2.14 mm (7/2.14, 1+6 layout), nominal area 25 mm² — ≈ 6.42 (Ø neutral core) Return / neutral path; DC resistance capped at 0.727 Ω/km at 20 °C
3 Phase insulation (XLPE) × 3 Cross-linked polyethylene dielectric 1 ≈ 11.00 (Ø each phase core, incl. insulation) Electrical isolation; 90 °C continuous rating; withstands 3.5 kV for 5 min
4 Neutral insulation (XLPE) × 1 Cross-linked polyethylene dielectric 0.9 ≈ 8.22 (Ø neutral core, incl. insulation) Electrical isolation for the neutral conductor
5 Core assembly Neutral core at centre + three phase cores cabled around + dry filler + binder wrap — ≈ 23.4 (Ø over assembled cores, calc.) 3+1 configuration; forms a round, stable bundle
6 Outer jacket (PVC) Flame-retardant PVC, ST2 compound, black 2 ≈ 27.4 (Ø finished cable, Zhongce) Mechanical and moisture protection; ZC flame retardance per GB/T 19666
Key Dimensions & Properties
Finished cable diameter ≈ 27.4 mm Zhongce 3+1 unarmored datasheet    
Approximate cable mass ≈ 1901 kg/km Zhongce copper-conductor figure    
Nominal voltage rating 0.6/1 kV AC 50 Hz; maximum system voltage Um = 1.2 kV    
Conductor temperature limits 90 / 250 °C Continuous service / short-circuit (≤ 5 s)    
Minimum bend radius (multi-core) ≥ 15 × OD — OD = actual finished cable diameter    
Flame-retardant classification ZC (ZR) — Per GB/T 19666    
Schematic — not to exact scale. Nominal values for reference; confirm against factory test certificate.

 

OEM Copper Xlpe Cable 4 Core Heat Resistant Flex 3×50mm2+1×25mm2 For Heavy Duty

 

6. Thermal & Fire. 90 °C continuous conductor, 250 °C short-circuit (≤ 5 s); service ambient −20 to +45 °C, minimum laying temp 0 °C; ZC per GB/T 19666 — GB/T 18380.12 single-cable + GB/T 18380.35 category-C bunched (char ≤ 2.5 m); PVC jacket is halogenated — specify WDZ-YJY for LSZH.

 

Flame-Retardant (FR) Characteristics — ZR-YJV 3×50+1×25 mm²
ZR-YJV 3×50+1×25 mm²  (3 (L1+L2+L3, 50 mm²) + 1 (N, 25 mm²); 3+1 = L1+L2+L3+N)   ·   0.6/1 kV
1.  Cable Identification
Code / Item Meaning / Value Standard / Note
Designation ZR-YJV 3×50+1×25 mm² GB/T 12706.1-2020
ZR Flame Retardant (legacy); under GB/T 19666-2019 defaults to Class C; modern = ZC GB/T 19666-2019
YJ XLPE insulation (cross-linked polyethylene) —
V PVC outer sheath — flame-retardant, contains halogen (Cl) GB/T 19666-2019
0.6/1 kV U₀/U = 600/1000 V; Uₘ = 1.2 kV IEC 60502-1
3×50+1×25 mm² Three 50 mm² phase cores + one 25 mm² neutral core (reduced neutral, 3+1 construction) —
Construction Unarmoured, non-screened, round multi-core (3+1) —
Application note 3+1 core → three-phase AC with neutral (L1+L2+L3+N); neutral reduced to 25 mm². No separate PE (use 4-core or 5-core if PE required). —
2.  Flame-Retardant & Fire Performance  (CORE)
Property Value / Requirement Standard
Flame Retardant Class Class C (bundled cables, char length ≤ 2.5 m) GB/T 19666-2019; GB/T 18380.3 / IEC 60332-3-24
Legacy designation ZR (= ZC); modern prefix preferred: ZC GB/T 19666-2019
Test method — flame Bunched flame test (category C), char ≤ 2.5 m after flame removal GB/T 18380.3 (IEC 60332-3-24)
Halogen content Contains halogen — Cl from PVC sheath; releases HCl on burning GB/T 17650 / IEC 60754-1/-2
Smoke density Heavy dark smoke — NOT low-smoke (no LSZH certification) GB/T 17651 / IEC 61034
Corrosivity Corrosive — HCl gas generated during fire GB/T 17650 / IEC 60754-2
pH / conductivity of gases Not certified (PVC base — acidic / conductive combustion gases) GB/T 17650 / IEC 60754-2
Limited Oxygen Index (LOI) PVC typical ≈ 45–49 % O₂ (reference, design value) ASTM D2863 / GB/T 2406, reference
Max. conductor operating temp. 90 °C (long-term service) GB/T 12706.1-2020
Max. short-circuit temp. (≤5 s) 250 °C IEC 60502-1
Emergency overload temp. 105 °C (up to 130 °C transient) IEC 60502-1
Service ambient range (PVC sheath) −15 °C to +90 °C —
Min. installation ambient temp. 0 °C (pre-heat required below 0 °C) —
3.  Fire Test Summary
Test Requirement ZR-YJV 3×50+1×25 mm² Verdict
Bunched flame test (Class C) Char length ≤ 2.5 m PASS (design, Class C)
Single flame test (IEC 60332-1) Self-extinguishing PASS (XLPE/PVC FR)
Smoke density (IEC 61034) Light transmittance ≥ 60 % for LSZH N/A (PVC = heavy smoke)
Halogen content (IEC 60754) ≤ 0.5 % HCl for LSZH N/A (contains Cl)
Acidity / corrosivity (IEC 60754-2) pH ≥ 4.3; conductivity ≤ 10 µS/mm for LSZH N/A (corrosive HCl)
Fire-survival (BS 6387 / IEC 60331) Circuit integrity during/after fire N/A — use NH-ZR-YJV
4.  Key Electrical & Thermal Parameters
Parameter Value Note
Rated voltage U₀/U 0.6 / 1 kV Uₘ = 1.2 kV
Test voltage AC (5 min, routine) 3.5 kV IEC 60502-1
Type-test voltage 4.0 kV IEC 60502-1
DC resistance @ 20 °C (phase, 50 mm²) ≤ 0.740 Ω/km GB/T 3956 / IEC 60228, Class 2 max
DC resistance @ 20 °C (neutral, 25 mm²) ≤ 0.740 Ω/km GB/T 3956 / IEC 60228, Class 2 max
AC resistance @ 90 °C (phase, est.) ≈ 0.962 Ω/km per phase core
Current rating — in air (30 °C, single circuit) ≈ 95–105 A (design ≈ 100 A) 3+1 core
Current rating — direct buried (20 °C, soil 1.0 K·m/W, 0.7 m) ≈ 115–130 A (design ≈ 122 A) 3+1 core
Short-circuit current (1 s, Cu, 250 °C, per core) ≈ 5.00 kA (per phase core) phase core; neutral ≈ 2.5 kA
5.  Construction & Material Specification (with FR Contribution)
Layer (inside → out) Description / Specification FR Contribution
Conductor (phase ×3) Bare annealed copper, Class 2 stranded, 19ר1.78 mm, Ø ≈ 8.30 mm None (Cu non-combustible)
Conductor (neutral ×1) Bare annealed copper, Class 2 stranded, 19ר1.78 mm, Ø ≈ 8.30 mm None (Cu non-combustible)
Conductor screen Omitted (not required for 0.6/1 kV) —
Insulation (×4) XLPE (cross-linked polyethylene), phase 1.0 mm (e_min 0.80) / neutral 0.9 mm (e_min 0.71); L1/L2/L3 = brown/black/grey, N = blue XLPE — low flame spread
Filler Flame-retardant PP / PE to form round assembly FR additive
Binder Flame-retardant tape over laid-up cores FR barrier
Inner binder / assembly FR tape, no inner sheath required for plain YJV FR barrier
Outer sheath Flame-retardant PVC (ZR grade), 1.5 mm (multi-core, 3+1 rule), Black (standard) Primary FR layer (halogenated)
Armour None —
Metallic screen None —
6.  Dimensional Data
Item Typical Value Remarks
Conductor nominal area 3×50 mm² + 1×25 mm² phase / neutral
Number of cores 4 (3+1) —
Conductor construction Phase: Class 2, 19ר1.78 mm; Neutral: Class 2, 7ר2.14 mm min. 7 wires
Conductor diameter (approx.) Phase ≈ 8.30 mm; Neutral ≈ 6.70 mm —
Insulation thickness Phase 1.0 mm; Neutral 0.9 mm (50 / 25 mm² classes) 0.9 / 0.7 mm class
Diameter over insulated core Phase 10.3 mm; Neutral 8.5 mm conductor + 2×insulation
Sheath thickness 1.5 mm (multi-core, 3+1 rule) 3+1 multi-core rule
Overall cable diameter 16.0 – 19.5 mm (design ≈ 24.0 mm) design ≈ 24.0 mm
Approx. weight 720 – 920 kg/km (use ≈ 880 kg/km) —
Cable shape Round —
7.  Mechanical & Installation Parameters
Parameter Value Note
Minimum bending radius (unarmoured multi-core) ≥ 15 × OD ≈ 360 mm @ Ø≈ 24.0 mm —
Max. pulling tension (Cu only) 50 N/mm² × (3×50 + 1×25) = 8,750 N total use conductor sock, avoid sheath grip
Direct burial Allowed in non-aggressive soil; for mechanical protection use ZR-YJV22 3×50+1×25 —
Conduit ID ≥ 1.5 × OD → ≥ 27 mm (use 32 mm or 40 mm conduit) —
Fixing (horizontal / vertical tray) ≈ 800 mm / ≈ 1500 mm (horizontal / vertical tray) —
Elevation difference limit None (XLPE) —
8.  Selection Guide — When FR Matters
Scenario Recommended Cable Reason
Flame-retardant, halogenated acceptable (standard) ZR-YJV 3×50+1×25 mm² (this cable) Class C FR, PVC sheath, cost-effective
Low-smoke halogen-free required (LSZH) WDZ-YJY 3×50+1×25 LSZH sheath — IEC 61034 / IEC 60754 compliant
Fire-survival circuit (circuit integrity) NH-ZR-YJV / WDZN-YJY 3×50+1×25 BS 6387 / IEC 60331 fire-survival grade
1. ZR is the legacy GB/T 19666-2019 Class C designation; modern equivalent is ZC. Class C: char ≤ 2.5 m after bunched flame test (GB/T 18380.3).
2. PVC sheath is halogenated (contains Cl, releases HCl) → heavy smoke and corrosive gases; NOT suitable for LSZH-required routes (use WDZ-YJY).
3. 3×50+1×25 mm² = three 50 mm² phase cores (L1+L2+L3) + one 25 mm² neutral (N), total 4 cores (3+1); neutral is reduced in size. Current ratings (≈155 A air / ≈185 A buried) are design values; apply grouping, ambient temperature, soil thermal resistivity and IEC 60364-5-52 correction factors.
4. For LSZH → WDZ-YJY 3×50+1×25; for fire-survival → NH-ZR-YJV / WDZN-YJY 3×50+1×25; for armour → ZR-YJV22 3×50+1×25; for separate PE → use 5-core (e.g. 5×25).
5. DC resistance phase ≤ 0.740 Ω/km, neutral ≤ 0.740 Ω/km (GB/T 3956 Class 2 max). Test values marked “reference” are typical design values — confirm against manufacturer test report / GB/T 12706.1-2020.

 

7. Installation & Care. Minimum bend ≥ 15 × OD; commissioning DC test 4U0 = 2.4 kV / 15 min before first energisation (Q/GDW 13244.1-2018); warm drums below 0 °C before pulling; derate the 200/210 A references for ambient, grouping and soil; fit lugs and glands sized for the 9.00 mm phase core, 6.42 mm neutral core and 27.4 mm jacket.

 

Insulation Test Data — ZR-YJV 3×50+1×25 mm²
ZR-YJV 3×50+1×25 mm²  (Cu / XLPE / FR-PVC)   ·   0.6/1 kV
1.  Cable Identification
Item Description Standard / Note
Designation ZR-YJV 3×50+1×25 mm² GB/T 12706.1-2020
Conductor Bare annealed copper, Class 2 stranded — phase 3×19ר1.78 mm, neutral 1×7ר2.14 mm GB/T 3956 / IEC 60228
Insulation XLPE (cross-linked polyethylene), phase 1.0 mm / neutral 0.9 mm nominal (50 / 25 mm² respectively) GB/T 12706.1-2020
Insulator colours L1/L2/L3 = brown/black/grey (25 mm²); N = blue (25 mm²) IEC 60446
Outer sheath Flame-retardant PVC (ZR grade), 1.5 mm (multi-core, 3+1 rule), Black (standard) GB/T 19666-2019
Rated voltage U₀/U 0.6 / 1 kV Uₘ = 1.2 kV
Number of cores 4 (3×50 mm² phase + 1×25 mm² neutral, 3+1) —
2.  Insulation Design Data  (CORE)
Parameter Value Remarks
Insulation material XLPE (cross-linked polyethylene) —
Nominal thickness (eₙ) Phase 1.0 mm (50 mm²); Neutral 0.9 mm (25 mm²) two core sizes
Minimum allowable thickness (e_min) Phase 0.71 mm; Neutral 0.54 mm eₙ − 0.19 / eₙ − 0.16 (GB/T 12706.1-2020, Table 3)
Insulator colours L1/L2/L3 = brown/black/grey (25 mm²); N = blue (25 mm²) IEC 60446
Volume resistivity @ 90 °C ≥ 10¹² Ω·cm —
Dielectric loss factor (tan δ) @ 20 °C ≤ 1 × 10⁻³ reference
Relative permittivity (εᵣ) ≈ 2.3 – 2.5 reference
Long-term service temp. 90 °C GB/T 12706.1-2020
Short-circuit temp. (≤ 5 s) 250 °C IEC 60502-1
Emergency overload temp. 105 – 130 °C transient
Diameter over insulated core Phase 10.3 mm; Neutral 8.5 mm phase 8.30 + 2×1.0 / neutral 6.70 + 2×0.9
3.  Thermal Characteristics
Property Value Remarks
Max. conductor operating temp. (normal) 90 °C long-term
Max. conductor temp. — short-circuit (≤ 5 s) 250 °C IEC 60502-1
Emergency overload temp. 105 °C (up to 130 °C transient) —
Min. installation ambient temp. 0 °C (pre-heat below 0 °C) —
Service ambient range (PVC sheath) −15 °C to +90 °C —
Flame retardant class (sheath) Class C (ZR per GB/T 19666) —
4.  Insulation Test Schedule
Test Item Test Value / Condition Result
Routine withstand test (AC) 3.5 kV AC, 5 min — no breakdown PASS
Type test voltage 4.0 kV AC PASS (IEC 60502-1)
Partial discharge test ≤ 10 pC @ 1.73 U₀ (1.73 kV) PASS (XLPE)
Insulation resistance (IR) ≥ 10⁴ MΩ·km @ 20 °C (reference) PASS
Hot-set test (XLPE cross-linking) 200 °C, 15 min, load 0.2 N/mm² — elongation ≤ 175 %, permanent set ≤ 15 % PASS (IEC 60811-507)
Aging test (air oven) 135 °C, 168 h — tensile strength / elongation retained ≥ 80 % PASS
Tensile strength (insulation) ≥ 12.5 MPa (XLPE, before aging) PASS
Elongation at break (insulation) ≥ 200 % (XLPE, before aging) PASS
Cold bend test −15 °C, 4 h — no cracking PASS
Water absorption ≤ 1 mg/cm² (85 °C, 336 h, reference) PASS
Breakdown voltage (insulation) ≥ 20 kV/mm (reference) PASS
DC resistance of conductor @ 20 °C Phase ≤ 0.387 Ω/km; Neutral ≤ 0.740 Ω/km (Class 2 Cu) PASS (GB/T 3956)
Dielectric loss (tan δ) measurement ≤ 1 × 10⁻³ @ 20 °C PASS (reference)
Spark test (during production) 6 – 10 kV (online), pinhole detection PASS
Thickness measurement (microscopic) Phase eₙ = 0.9 / 0.7 mm; e_min ≥ 0.71 / 0.54 mm PASS
5.  Electrical Parameters
Parameter Value Note
Rated voltage U₀/U 0.6 / 1 kV Uₘ = 1.2 kV
Test voltage AC (5 min, routine) 3.5 kV IEC 60502-1
Type-test voltage 4.0 kV IEC 60502-1
DC resistance @ 20 °C (phase, 50 mm²) ≤ 0.740 Ω/km GB/T 3956 / IEC 60228, Class 2 max
DC resistance @ 20 °C (neutral, 25 mm²) ≤ 0.740 Ω/km GB/T 3956 / IEC 60228, Class 2 max
AC resistance @ 90 °C (phase, est.) ≈ 0.962 Ω/km per phase core
Current rating — in air (30 °C, single circuit) ≈ 95–105 A (design ≈ 100 A) 3+1 core
Current rating — direct buried (20 °C, soil 1.0 K·m/W, 0.7 m) ≈ 115–130 A (design ≈ 122 A) 3+1 core
Short-circuit current (1 s, Cu, 250 °C, per core) ≈ 5.00 kA (per phase core) reference; neutral ≈ 2.5 kA
Frequency 50/60 Hz AC —
6.  Dimensional / Inspection Result
Item Design / Limit Measured (example)
Conductor construction Phase 3×19ר1.78 mm; Neutral 1×7ר2.14 mm 19ר1.78 mm / 7ר2.14 mm
Conductor diameter Phase ≈ 8.30 mm; Neutral ≈ 6.70 mm 6.65 / 5.15 mm
Insulation thickness (per core) Phase 0.9 mm / Neutral 0.7 mm (min. 0.71 / 0.54 mm) — all 4 cores 1.03 / 1.01 / 1.00 / 0.92 mm (L1/L2/L3/N)
Diameter over insulated core Phase 10.3 mm; Neutral 8.5 mm 8.45 / 6.55 mm
Sheath thickness 1.5 mm (multi-core, 3+1 rule) (min. 1.2 mm) 1.53 mm
Overall cable diameter 16.0 – 19.5 mm (design ≈ 24.0 mm) 23.8 mm
Approx. weight 720 – 920 kg/km (use ≈ 880 kg/km) ≈ 865 kg/km
DC resistance @ 20 °C Phase ≤ 0.740 Ω/km; Neutral ≤ 0.740 Ω/km 0.756 / 0.748 Ω/km
Max. pulling tension (Cu only) 50 N/mm² × (3×50 + 1×25) = 8,750 N total conductor sock
1. All tests performed at ambient 20 ± 5 °C and 45–75 % RH unless otherwise stated.
2. Routine tests: withstand (3.5 kV / 5 min), conductor resistance, dimensional check. Type tests: 4.0 kV, partial discharge, hot-set, aging, mechanical (per IEC 60502-1).
3. Test values marked “reference” are typical design values — confirm against manufacturer test report / GB/T 12706.1-2020.
4. Insulation thickness: phase 50 mm² = 1.0 mm (e_min = 1.0 − 0.20 = 0.80 mm); neutral 25 mm² = 0.9 mm (e_min = 0.9 − 0.19 = 0.71 mm) (GB/T 12706.1-2020, Table 3).
5. 3×50+1×25 mm² = three 50 mm² phase cores (L1+L2+L3) + one 25 mm² neutral (N), total 4 cores (3+1); neutral is reduced. Four thickness readings (L1/L2/L3/N) are recorded at inspection.
6. For low-smoke halogen-free → WDZ-YJY 3×50+1×25; for fire-survival → NH-ZR-YJV / WDZN-YJY 3×50+1×25; for armoured → ZR-YJV22 3×50+1×25; for separate PE → 5-core cable.

 

8. Application. Three-phase four-wire distribution, larger building mains and heavy industrial feeders requiring a dedicated neutral conductor in a single cable (TN-C style) — conduit, tray, trench, duct, trunking; indoor or sheltered outdoor.

 

OEM Copper Xlpe Cable 4 Core Heat Resistant Flex 3×50mm2+1×25mm2 For Heavy Duty

 

9. Ordering. ZR-YJV 0.6/1 kV 3×50+1×25 + supply length/drum + surface marking; verify against factory test certificate.

 

OEM Copper Xlpe Cable 4 Core Heat Resistant Flex 3×50mm2+1×25mm2 For Heavy Duty

 

 

OEM Copper Xlpe Cable 4 Core Heat Resistant Flex 3×50mm2+1×25mm2 For Heavy Duty