OEM Copper Xlpe Cable 4 Core Heat Resistant Flex 3×50mm2+1×25mm2 For Heavy Duty

OEM Copper Xlpe Cable 4 Core Heat Resistant Flex 3×50mm2+1×25mm2 For Heavy Duty

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
ZR-YJV 3×50mm²+1×25mm²

Trading Properties

moq
100 meters
payment method
L/C,T/T
supply capacity
10000 meters per month

Product Summary

Flame Retardant Copper Conductor ZR-YJV 3×50mm²+1×25mm² for Heavy-Duty Three Phase Supply Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 3×50 mm² + 1×25 mm² Three phase cores of 50 mm² + one neutral ...

Product Details

Highlight:

OEM 4 core heat resistant flex

,

4 core heat resistant flex 900kg/km

,

Heavy Duty copper xlpe cable

Phase conductor (×3):
Bare Annealed Copper, Class 2 Stranded, 19×∅1.78 Mm (also 7×∅3.00 Mm Compact), Conductor Ø ≈ 9.0–9.5 Mm Depending On Compaction
Neutral conductor (×1):
Bare Annealed Copper, Class 2 Stranded, 7×∅2.14 Mm, Conductor Ø ≈ 6.4–6.8 Mm
Phase conductor nominal area:
50 Mm²
Neutral conductor nominal area:
25 Mm²
Number of cores:
4 (3+1)
Phase conductor construction:
Class 2, 19×∅1.78 Mm,IEC 60228 / GB/T 3956
Neutral conductor construction:
Class 2, 7×∅2.14 Mm,IEC 60228 / GB/T 3956
Phase conductor diameter (approx.):
9.0–9.5 Mm
Neutral conductor diameter (approx.):
6.4–6.8 Mm
Insulation (×4):
XLPE
Phase insulation thickness:
1.0 Mm (50 Mm² Class)
Neutral insulation thickness:
0.9 Mm (25 Mm² Class)
Diameter over phase insulated core:
11.0–11.5 Mm
Diameter over neutral insulated core:
8.2–8.6 Mm
Filler / binder:
FR PP Filler + FR Tape
Outer sheath:
Flame-retardant PVC (ZR Grade)
Sheath thickness:
1.6 Mm (GB/T 12706 Multi-core 50–95 Mm² Range)
Overall cable diameter:
21.0 – 25.5 Mm
Design outer diameter:
≈ 23.0 Mm
Approx. weight:
700 – 900 Kg/km
Design weight:
≈ 770 Kg/km

Product Description

Flame Retardant Copper Conductor ZR-YJV 3×50mm²+1×25mm² for Heavy-Duty Three Phase Supply

Cable Designation & Meaning

Code

Meaning

ZC

Flame retardant Class C

YJ

Cross-linked polyethylene (XLPE) insulation 

V

Polyvinyl chloride (PVC) sheath 

3×50 mm² + 1×25 mm²

Three phase cores of 50 mm² + one neutral core of 25 mm² copper conductor


Construction: Three 50 mm² copper conductors (phase) + one 25 mm² copper conductor (neutral), XLPE insulation, PVC outer sheath. No metallic screen/armour as standard (can be added on request).



OEM Copper Xlpe Cable 4 Core Heat Resistant Flex 3×50mm2+1×25mm2 For Heavy Duty

ZC-YJV 3×50+1×25 mm² — LV Flame-Retardant 3+1 Power Cable — Specification

1. Overview & Ratings. ZC-YJV 3×50+1×25 is a compact 3+1 LV power cable rated 0.6/1 kV (Um 1.2), 90 °C working, ZC class C flame-retardant PVC sheath: three 50 mm² compacted copper phase cores plus one reduced 25 mm² neutral, dry-cured XLPE, unarmored (armor/screen optional). OD ≈ 16 mm, ≈ 1450 kg/km (est.), ≈ 120 A per phase free air at 30 °C (est.). Scope: 380/400 V motor branches, machine supplies and panel feeders — not 950°C fire duty.


2. Construction Stack (Inner → Outer, expanded).


Layer / Feature Build Function
Phase conductors L1/L2/L3 3×50 compacted Cu, Class 2, ≈19 strands Phases, R ≤0.387 Ω/km
Neutral conductor N 1×25 compacted Cu, Class 2, ≈7 strands Reduced neutral, R ≤0.741 Ω/km
Strand compaction Concentric layers rolled compact per core Compact round bundles, clean lugs
XLPE insulation (phases) Dry-cured PE, ≈1.6 mm 90°C phase dielectric
XLPE insulation (neutral) Dry-cured PE, ≈1.4 mm Matched neutral dielectric
3+1 core laying 3 phases around 1 neutral Stable compact round bundle
PVC ZC sheath Class C, ≈1.5 mm overall Binds bundle, self-extinguishes
Jacket print Continuous type/size/voltage/length On-site readable spec


3. Electrical Characteristics. Phase R ≤ 0.387 Ω/km, neutral R ≤ 0.741 Ω/km @20 °C. Test 3.5 kV AC / 5 min; ≈ 120 A per phase (est., air 30 °C); short-circuit ≈ 4.2 kA / 1 s (est.); 50/60 Hz; unscreened; low-loss XLPE; high stable insulation resistance.

Insulation & Sheath Data

Property

Value

Insulation material

XLPE (cross-linked polyethylene)

Outer sheath material

PVC (ST₂)

Long-term service temp.

90 °C (continuous)

Max. conductor temp. (normal)

90 °C

Short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Test voltage AC (5 min)

3.5 kV

Dielectric strength

≥ 20 kV/mm

Volume resistivity @20 °C

≥ 1×10¹⁴ Ω·cm

Shield

None as standard (can be added)

Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

GB/T 12706.1 / IEC 60502-1

Max. system voltage

1.2 kV AC

—

Test voltage AC (5 min)

3.5 kV

Routine test

DC resistance @20 °C (phase)

≤ 0.387 Ω/km per core

GB/T 3956 Class 2 Cu max (50 mm²)

DC resistance @20 °C (neutral)

≤ 0.727 Ω/km per core

GB/T 3956 Class 2 Cu max (25 mm²)

AC resistance @90 °C (est., phase)

≈ 0.496 Ω/km per core

—

AC resistance @90 °C (est., neutral)

≈ 0.932 Ω/km per core

—

Current rating in air (30 °C)

3-phase: 165 A​

3×50+1×25, touching, in free air

Current rating in tray (30 °C)

3-phase: 185 A​

3×50+1×25, spaced 2×OD

Current rating buried in ground (20 °C, thermal resistivity 1.2 K·m/W)

3-phase: 175 A​

direct buried

Current rating in conduit (30 °C)

3-phase: 145 A​

—

Short-circuit current (1 s, Cu, 250 °C, phase)

≈ 5.5 kA (5,500 A) per core

—

Short-circuit current (1 s, Cu, 250 °C, neutral)

≈ 2.8 kA (2,800 A) per core

—

Capacitance (core-to-sheath, approx.)

≈ 0.18 µF/km

XLPE

Inductive reactance (approx.)

≈ 0.08 Ω/km

at 50 Hz

Frequency

50/60 Hz AC

—


Reference values: 3×50+1×25 at 165 A three-phase, 400 V → max load ≈ 99 kW​ (cos φ = 0.8). Suitable for medium three-phase distribution with reduced neutral, industrial motors, and building sub-main feeders.


4. Thermal & Flame. 90 °C continuous, 250 °C short-time; ZC class C self-extinguishing — flame retardancy, not 950°C integrity; withstands repeated motor start-stop 0~90°C cycles; indoor; UV-grade jacket optional.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

90 °C (continuous)

Max. short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Min. installation ambient temp.

0 °C (below 0 °C requires preheating)

Service ambient range

−20 °C to +90 °C

Flexing temp. range

0 °C to +90 °C

Fire Performance (ZC-YJV — Flame Retardant C)

Property

Value / Requirement

Flame retardant

GB/T 18380.12 / IEC 60332-1-2​ (single cable, self-extinguishing)

Flame retardant class

Class C​ (ZC) per GB/T 19666

Halogen content

Contains halogen (PVC sheath)

Smoke density

Not low-smoke (PVC)

Corrosivity

Corrosive (PVC)

Toxicity

Toxic fumes when burned (PVC)

EMI shielding

None (no metallic screen/armour)


5. Installation Practice & Handling. 50 mm² phase lugs, 25 mm² neutral lug, glands to ≈16 mm OD, hydraulic crimp/torque per table; bend ≥ 15×OD ≈ 240 mm; apply conduit/bundle derating; keep the 3+1 bundle round; three-phase continuity, sequence, neutral + insulation after pulling.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 15 × OD → ≈ 368 mm at Ø24.5 mm

four-core unarmoured

Max. pulling tension (phase)

750 N per core (50 mm² × 15 N/mm²)

Cu conductor limit

Max. pulling tension (neutral)

375 N per core (25 mm² × 15 N/mm²)

Cu conductor limit

Direct burial

Suitable (with sand bedding)

—

Surface mounting

Heavy-duty cable tray, ladder, cleats

—

Conduit ID

≥ 50 mm

—

Fixing

heavy-duty cleats, cable ties

—

Impact resistance

Moderate

—

Water resistance

Good (PVC sheath)

—

UV resistance

Fair (PVC degrades outdoors, use UV-resistant PVC or conduit)

—

Flex life

Good (Class 2 stranded)

fixed installation

Termination note

Standard compression lugs or mechanical connectors

—


6. Typical Service Applications. 380/400 V motor branch circuits, compressors, pumps, fans, machine-tool power feeds, panel-to-equipment feeders and general three-phase machine supplies.


OEM Copper Xlpe Cable 4 Core Heat Resistant Flex 3×50mm2+1×25mm2 For Heavy Duty


7. Testing & QA Regime (16 items). Routine: phase DC resistance (50), neutral DC resistance (25), 3.5 kV withstand, insulation resistance, 3-phase+neutral continuity, phase/neutral insulation thickness, sheath thickness, dimensional check, strand construction, eccentricity, print legibility, mass, packing inspection. Type: ZC flame test, short-circuit rating, sheath mechanical.


Cable Parameters


ZC-YJV 3×50+1×25 mm² — LV Flame-Retardant 3+1 Power Cable — Full Parameter Sheet 
3×50 phase Cu + 1×25 neutral Cu · XLPE insulation / PVC sheath · ZC · 0.6/1 kV · ≈16 mm · 3+1 lay · 380/400 V motor branch, machine supply and panel feeder
Parameter Value Unit Remarks / Standard
01 · Identification
Cable type ZC-YJV — Cu/XLPE/PVC, flame-retardant class C — ZC-YJV denotes a copper conductor with cross-linked polyethylene insulation and a PVC outer sheath; ZC marks a class C flame-retardant PVC compound that self-extinguishes after the ignition source is removed.
Rated voltage (U0/U) 0.6/1 kV 0.6 kV phase-to-earth (U0) and 1 kV phase-to-phase (U) rating defines a general low-voltage cable suited to 380/400 V branch and panel distribution.
Maximum operating voltage (Um) 1.2 kV The 1.2 kV maximum system voltage is the continuous upper phase-to-earth limit the XLPE insulation may withstand in normal service.
Core configuration 3×50 phase + 1×25 neutral (3+1) — Three 50 mm² compacted copper phase cores plus one 25 mm² compacted neutral core, laid in a 3+1 arrangement for motor and panel branch circuits.
Conductor material Compacted stranded annealed copper — Soft annealed copper strands are layer-compacted into round 50 mm² phase and 25 mm² neutral bundles for clean lug entry.
Insulation XLPE cross-linked polyethylene — Chemically cross-linked polyethylene bonds into a heat-resistant dielectric retaining properties at the 90 °C operating temperature.
Sheath PVC, flame-retardant class C (ZC) — An overall PVC jacket binds the 3+1 bundle and carries the class C flame-retardant formulation; deep aubergine purple finish.
Flame retardancy ZC class C (self-extinguishing, not fire-rated) — On removal of a flame the cable stops propagating fire; this is flame retardancy, not 950 °C/180 min circuit-integrity fire resistance.
Suitable for Fixed motor branch, machine supply, panel feeder — Designed for fixed three-phase-plus-neutral branch feeders serving motors, machines and distribution panel groups.
Application 380V motor branch / machine power feeder — Typically runs from a panel breaker to a three-phase motor, compressor, pump or machine tool with a reduced neutral.
Application note Not for 950°C circuit-integrity fire duty — Do not substitute this ZC cable for a mineral-insulated or fire-resistant circuit; it cannot maintain live integrity under sustained fire.
02 · Conductors
Phase cores count / area 3 × 50 (L1/L2/L3) mm² Three 50 mm² phase conductors carrying the three-phase load current to the motor or machine.
Neutral core count / area 1 × 25 (N) mm² One 25 mm² neutral conductor sized for the branch neutral and limited harmonic current on balanced motor loads.
Conductor type Compacted stranded Cu, Class 2 — Class 2 stranded compacted construction gives fixed-wiring conductors that round into stable bundles for lug termination.
DC resistance (50 phase) @ 20°C ≤ 0.387 Ω/km Maximum permitted DC resistance of a 50 mm² copper phase conductor at 20 °C, applied to L1/L2/L3.
DC resistance (25 neutral) @ 20°C ≤ 0.741 Ω/km Maximum permitted DC resistance of the 25 mm² neutral conductor at 20 °C; higher than phases by design of the reduced neutral.
Stranding Layer-compacted concentric bundle — Concentric layers of strands are compacted radially per core to reduce gaps, tighten the bundle and present a clean round lug entry.
Strands (nom., est.) 50 ≈19; 25 ≈7 strands per core — Approximate compacted strand counts; exact count follows the conductor standard for each section.
Surface Bare copper; tinned optional — Bare copper suits most indoor use; optional tinned plating improves corrosion resistance in damp or chemically mild sites.
Core identification L1/L2/L3 phase colors + N neutral — Phase cores and the smaller neutral are color-coded so phase sequence and neutral match at the motor terminal box.
Neutral sizing logic Reduced neutral for balanced motor load — The 25 mm² neutral suits predominantly balanced three-phase motor circuits; enlarge the neutral where high third harmonics exist.
Compaction benefit Round bundle, lower OD, clean crimp — Radial compaction reduces overall diameter versus loose stranding and gives a flat, even lug crimp on both sections.
03 · Insulation
Insulation material XLPE (cross-linked polyethylene) — Cross-linked PE delivers a higher continuous temperature rating and lower dielectric loss than PVC insulation for the same size.
Insulation thickness (50 phase, nom.) ≈ 1.6 mm Nominal radial insulation wall on each 50 mm² phase core; gauged to withstand the 3.5 kV routine test.
Insulation thickness (25 neutral, nom.) ≈ 1.4 mm Nominal insulation wall on the smaller 25 mm² neutral core, matched to its voltage class.
Working conductor temp. 90 °C Maximum continuous conductor temperature under rated current without shortening insulation life.
Short-circuit temp. 250 °C Peak conductor temperature the insulation may survive for a short fault duration (seconds) before damage occurs.
Insulation resistance High and stable MΩ·km XLPE keeps a high, stable insulation resistance over life, supporting reliable earth-fault detection on branch feeders.
Color L1/L2/L3/N color on request — Insulation colors are matched to local 3-phase convention or supplied natural with printed marking.
Cure type Chemical / dry-cured XLPE — A controlled cross-linking cure locks the polymer network so the insulation stays elastic rather than melting under heat.
04 · Sheath & Flame Retardancy
Sheath material PVC, flame-retardant ZC — The class C PVC outer jacket blends a flame-suppressing formulation while keeping a smooth, printable surface.
Sheath thickness (nom.) ≈ 1.5 mm Nominal overall jacket wall sized to shield the 3+1 bundle from abrasion, mechanical handling and duct damage.
Finished outer diameter ≈ 16 mm Overall 3+1 finished diameter used to size glands, trunking and conduit for motor branch runs.
Flame behavior Self-extinguishing, class C — After the test flame is removed the sample extinguishes without propagating; it is not 950°C fire-rated.
Sheath color Deep aubergine purple (black/gray on request) — Standard deep aubergine purple; black or dark gray jackets are supplied for industrial aesthetics on request.
Surface finish Smooth, continuous print — A smooth jacket carries a continuous printed line of type, size, voltage, ZC class and meter length along its length.
05 · Electrical
Rated voltage (U0/U) 0.6/1 kV Low-voltage rating matching 380/400 V motor and panel branch systems.
Max voltage (Um) 1.2 kV Continuous upper system voltage for phase-to-earth insulation stress.
Nominal current (per 50 phase, est.) ≈ 120 A Approximate ampacity of a 50 mm² phase core in free air at 30 °C; reduce for bundling, conduit fill and high ambient.
Test voltage (AC) 3.5 kV / 5 min — Routine dielectric withstand applied between each conductor and sheath for five minutes without breakdown.
Insulation resistance High, XLPE MΩ·km Measured after conditioning; confirms no void, crack or contamination in the cured insulation.
Short-circuit current (50 phase, 1s, est.) ≈ 4.2 kA Approximate 1-second copper short-time withstand on the 50 mm² phase core; branch fault coordination.
Frequency 50 / 60 Hz Compatible with both 50 Hz and 60 Hz three-phase power systems.
Dielectric XLPE, low loss — Low dielectric loss keeps heating down under continuous motor branch and machine feeder load.
06 · Thermal & Environment
Normal conductor temp. 90 °C Sustained operating temperature the XLPE insulation is rated for under full load.
Installed ambient 0 ~ +40 °C Recommended continuous ambient around the cable; hot motor rooms and crowded trays require ampacity derating.
Min install temp. 0 °C Avoid cold bending below 0 °C where the PVC jacket and insulation may stiffen and crack.
Burning Self-extinguishing, ZC class C — Class C vertical flame test behavior: flame stops once the external burner is removed.
Outdoor / UV Indoor preferred; UV-grade jacket optional — Standard PVC degrades under prolonged direct sun; specify UV-stabilized jacket for exposed outdoor machine runs.
Oil / chemicals Resistant to common oils; check aggressive media — Withstands typical machine oils; verify against specific solvents, cutting fluids or acid fumes before use.
Temperature cycle Withstands repeated 0~90°C duty — The insulation and jacket survive repeated motor start-stop heating/cooling cycles without cracking.
07 · Mechanical & Construction
Min bending radius (fixed) ≥ 15 × OD ≈ 240 mm Fixed-installation minimum bend radius for the 3+1 cable; tight bends risk insulation and jacket damage.
Flexibility Stranded, easy to route to machines — Compacted strands remain flexible enough for panel-to-machine runs without large rollers.
Shielding / Armor None / unarmored (armor optional) — No copper braid screen and no armor as standard; add braid screen for VFD EMI and armor for ground-crushing ducts.
Cable weight per km (est.) ≈ 1450 kg/km Moderate mass per kilometer used for tray loading and drum sizing on branch circuits.
Circularity 3+1 bundle, stable compact OD — Three phases around the reduced neutral form a compact round bundle after sheathing.
Tensile / elongation Jacket meets PVC grade — Jacket tensile strength and elongation satisfy the PVC compound grade for machine-room pulling.
08 · Factory Advantages
Balanced 3+1 sizing 3×50 phases with 1×25 neutral for motor loads — Right-sized neutral avoids excess copper cost on predominantly balanced three-phase branches.
Stable XLPE cure Even cross-linking keeps the 90°C dielectric consistent — Controlled cure prevents soft spots in insulation under repeated motor start-stop cycles.
Dosed ZC compound Flame-retardant PVC self-extinguishes to class C — Self-extinguishing jacket protects machine rooms and panel wiring spaces.
Length-on-demand Cut to exact machine/branch meter, sealed ends — Custom cut lengths match the measured panel-to-machine route and reduce waste.
Dual-section resistance log Phase 50 and neutral 25 R logged to lot — Both conductor sections are recorded for incoming inspection and traceability.
Continuous print line Type, size, ZC, voltage and length along jacket — Clear continuous marking lets installers read phase and neutral section on short branch runs.
Phase-color option L1/L2/L3/N insulation colors matched to convention — Pre-colored cores reduce wiring errors at the motor terminal box.
Compact drum pack Standard wooden drum with sealed ends — Moderate branch length wound on a manageable drum for site handling.
Certified QA pack Routine + type test record shipped per batch — A complete QA packet supports buyer inspection and machine commissioning sign-off.
09 · Installation
Laying Panel-to-machine branch, tray, conduit, 3-phase+N — Route in trays, conduit or direct to motor terminal boxes; keep the 3+1 bundle round and observe bend radius.
Connectors 50 mm² phase lugs; 25 mm² neutral lug — Crimp 50 mm² lugs on L1/L2/L3 and a 25 mm² lug on N; select glands sized to ≈16 mm OD.
Bend radius ≥ 15×OD ≈ 240 mm — Maintain the minimum radius around panel elbows and machine entry points.
Parallel runs Derating in bundles and conduit — Adjacent loaded cores share heat; apply conduit and bundle derating before breaker selection.
Site test Continuity + insulation post-laying — After pulling, verify three-phase continuity, phase sequence, neutral continuity and insulation resistance.
Termination Strip, hydraulic crimp lug, torque per table — Strip insulation without nicking strands, use matched dies on each lug, and torque per the lug table.
10 · Packing & Applications
Supply length Custom / standard wooden drum m Cut to the measured branch length on a standard drum.
Length tolerance Per trade standard for cut lengths — Cut-length tolerance follows the applicable trade standard rather than a fixed meter promise.
Reel type Standard wooden drum — Drum for moderate branch lengths; sealed ends prevent moisture ingress.
Surface marking ZC-YJV, 3×50+1×25, 0.6/1kV, ZC, length — Jacket prints type, phase/neutral section, voltage, flame class and cumulative meter length.
Typical use Motor branch, compressor, pump, machine feeder — Three-phase motors, compressors, pumps, fans and machine-tool power feeds.
Storage Dry indoor on drum supports, avoid UV — Store the drum horizontally on timber supports, dry and shaded, avoiding direct sunlight.


Cable Test Parameters


Test Parameters — ZC-YJV 3×50+1×25 LV Flame-Retardant 3+1 Cable 
No. Test Item Test Condition / Method Requirement Type
1 DC resistance (50 phase) 20 °C, L1/L2/L3 (50 mm²) ≤0.387 Ω/km Routine
2 DC resistance (25 neutral) 20 °C, N (25 mm²) ≤0.741 Ω/km Routine
3 Voltage test (AC) 3.5 kV AC, 5 min, core-to-sheath No breakdown Routine
4 Insulation resistance XLPE, 20°C, per core High & stable Routine
5 Continuity 3 phases + neutral Continuous Routine
6 Flame retardancy Class C vertical test Self-extinguish Type
7 Sheath thickness Micrometer, cross-section Nominal ≈1.5 mm Routine
8 Phase insulation thickness Micrometer, 50 mm² cores Nominal ≈1.6 mm Routine
9 Neutral insulation thickness Micrometer, 25 mm² core Nominal ≈1.4 mm Routine
10 Dimensional check Caliper, overall OD OD ≈ 16 mm Routine
11 Conductor construction Visual / strand count per core Class 2 compacted Routine
12 Short-circuit rating Calculated / type ≈4.2 kA / 1 s Type
13 Insulation eccentric test Cross-section measure per core Within tolerance Routine
14 Printing legibility Visual Marking readable Routine
15 Mass per unit length Weigh / calculate ≈ 1450 kg/km Routine
16 Packing & drum inspection Visual / drum condition Sealed ends, sound drum Routine


Cable Cross Section Structure

OEM Copper Xlpe Cable 4 Core Heat Resistant Flex 3×50mm2+1×25mm2 For Heavy Duty

ZC-YJV 3×50+1×25 — 3+1 Cross-Section Construction Diagram (Schematic, Expanded)
3×50 phase Cu + 1×25 neutral Cu / XLPE insulation / PVC ZC sheath · 0.6/1 kV · ZC class C · ≈16 mm · motor branch, machine supply & panel feeder
No. Layer / Feature Material / Construction Nominal Thickness (mm) Diameter (mm) Detailed Function / Remarks
1 Conductor L1 — phase 1×50 compacted Cu, Class 2, ≈19 strands — ≈ 8.0 Phase 1 core, DC R ≤0.387 Ω/km @20°C; motor load current.
2 Conductor L2 — phase 1×50 compacted Cu, Class 2, ≈19 strands — ≈ 8.0 Phase 2 core, equal size/resistance for balanced three-phase.
3 Conductor L3 — phase 1×50 compacted Cu, Class 2, ≈19 strands — ≈ 8.0 Phase 3 core, equal spec; color-coded for phase sequence.
4 Conductor N — neutral 1×25 compacted Cu, Class 2, ≈7 strands — ≈ 5.6 Reduced neutral, R ≤0.741 Ω/km; balanced motor neutral return.
5 Strand compaction Concentric layers rolled compact per core — — Radial compaction closes gaps for compact round bundles and clean lugs.
6 XLPE insulation (50 phase) Dry-cured cross-linked PE, ≈1.6 mm ≈ 1.6 ≈ 11.2 90°C phase dielectric; low loss, passes 3.5 kV routine test.
7 XLPE insulation (25 neutral) Dry-cured cross-linked PE, ≈1.4 mm ≈ 1.4 ≈ 8.4 Neutral dielectric matched to the smaller 25 mm² section.
8 3+1 core laying 3 phases around 1 reduced neutral — — Compact 3+1 bundle arrangement stabilizes the round finished form.
9 PVC ZC sheath Class C jacket, ≈1.5 mm ≈ 1.5 ≈ 16 Binds the 3+1 bundle; self-extinguishes to class C; aubergine finish.
10 Jacket print Continuous type/size/voltage/length line — — Marking: ZC-YJV, 3×50+1×25, 0.6/1kV, ZC, cumulative length.
Key Dimensions, Electrical & Mechanical Properties (expanded)
Finished cable diameter ≈ 16 mm Compact 3+1 branch OD for glands and conduit.
Approx. cable mass (est.) ≈ 1450 kg/km Moderate branch feeder mass; standard drum.
Nominal voltage rating 0.6/1 kV Matches 380/400 V motor and panel systems.
Max voltage (Um) 1.2 kV Phase-to-earth continuous upper limit.
Normal conductor temp. 90 °C Continuous load temperature of XLPE.
Short-circuit temp. 250 °C Short-time fault peak before insulation damage.
DC resistance (50 phase) ≤ 0.387 Ω/km Per phase core @20°C.
DC resistance (25 neutral) ≤ 0.741 Ω/km Reduced neutral @20°C.
Neutral sizing 1×25 reduced neutral — For balanced motor loads; enlarge on high harmonics.
Nominal phase current (est.) ≈ 120 A Per 50 phase core, free air 30°C; derate in conduit.
Short-circuit rating (1s, est.) ≈ 4.2 kA Branch fault coordination duty.
Flame retardancy ZC class C, self-extinguishing — Not 950°C fire-rated.
Min bending radius (fixed) ≥ 15 × OD ≈ 240 mm Panel-to-machine bend radius.
Frequency 50 / 60 Hz Compatible with both power systems.
Insulation resistance High & stable MΩ·km XLPE; supports earth-fault detection.
Dielectric loss Low — XLPE limits heating on motor duty.
Temperature cycle 0~90°C repeated — Survives motor start-stop cycling.
Sheath mechanical Jacket meets PVC grade — Tensile/elongation checked at type test.
Pack choice Standard wooden drum — Sealed ends, manageable branch length.
Application Motor branch, compressor, pump, machine — 380/400 V three-phase machine power feeds.
Schematic — not to exact scale. OD ≈16 mm, weight ≈1450 kg/km, phase ampacity ≈120 A free air at 30°C and ≈4.2 kA/1s are (est.) from cross-referenced industry samples. ZC-YJV 3×50+1×25 serves 380/400 V motor branches, machine supplies and panel feeders; ZC class C self-extinguishes but is not 950°C fire-rated. Estimated values require confirmation against the factory test certificate for the specific batch.


Cable Construction Description


Construction Description — ZC-YJV 3×50+1×25 LV flame-retardant 3+1 cable 
3×50 phase Cu + 1×25 neutral Cu / XLPE insulation / PVC ZC sheath · 0.6/1 kV · ZC class C · 90°C · ≈16 mm · motor branch, machine supply & panel feeder
1. Product Identity & Ratings
ZC-YJV 3×50+1×25 rated 0.6/1 kV (Um 1.2), 90°C working, ZC class C; three 50 mm² phase cores plus one 25 mm² neutral in a 3+1 lay. OD ≈16 mm, ≈1450 kg/km (est.), ≈120 A per phase free air at 30°C (est.), standard wooden drum. It is a fixed motor branch cable, not a flexible cord and not a 950°C fire-rated circuit.
2. Copper Conductors (3×50 phase + 1×25 neutral)
Three compacted Class 2 Cu phase cores (L1/L2/L3), R ≤0.387 Ω/km @20°C, plus one 25 mm² neutral, R ≤0.741 Ω/km @20°C; reduced neutral suits balanced motor loads; tinned plating optional; phase-color insulation on request.
3. Strand Compaction & 3+1 Bundle
Concentric strands are rolled compact per core to close gaps and give clean lug entry; three phases surround the reduced neutral to form a compact round 3+1 bundle before sheathing.
4. XLPE Insulation
Dry-cured cross-linked PE ≈1.6 mm on phases and ≈1.4 mm on the neutral; stable 90°C dielectric, low dielectric loss, high insulation resistance; short-circuit peak 250°C; matched wall per section.
5. Core Identification
L1/L2/L3 phases and the N neutral are identified by insulation color; the smaller neutral section also distinguishes it visually from the three phase cores at the motor terminal box.
6. PVC ZC Sheath
Class C flame-retardant PVC ≈1.5 mm overall, self-extinguishing; deep aubergine purple standard (black/gray on request); smooth printable surface; binds the 3+1 bundle and shields from machine-room abrasion.
7. Electrical Characteristics
0.6/1 kV, Um 1.2; phase R ≤0.387, neutral R ≤0.741 Ω/km; routine 3.5 kV AC/5 min; ≈120 A per phase (est., air 30°C); short-circuit ≈4.2 kA/1s (est.); 50/60 Hz; unscreened; low-loss XLPE.
8. Factory Advantages
• Balanced 3+1 sizing (cost-effective reduced neutral).  • Stable XLPE cure.  • Dosed ZC self-extinguish.  • Length-on-demand.  • Dual-section resistance log.  • Continuous clear print.  • Phase-color option.  • Compact drum pack.  • Certified QA pack.
9. Site Handling & Installation
• Bend 15×OD (≈240 mm).  • 50 mm² phase lugs, 25 mm² neutral lug, glands to ≈16 mm OD, hydraulic crimp, torque per table.  • Conduit/bundle derating.  • Keep 3+1 bundle round.  • Three-phase continuity, sequence, neutral + insulation after pulling.
10. Typical Service Applications
380/400 V motor branch circuits, compressors, pumps, fans, machine-tool power feeds, panel-to-equipment feeders and general three-phase machine supplies.
11. Testing & QA
16-item regime: routine phase DC resistance (50), neutral DC resistance (25), 3.5 kV withstand, insulation resistance, 3-phase+neutral continuity, phase/neutral insulation thickness, sheath thickness, dimensional check, strand construction, eccentricity, print legibility, mass, packing inspection; type ZC flame, short-circuit, sheath mechanical.
12. Packaging, Storage & Notes
Cut to measured branch length on a standard wooden drum with sealed ends; continuous marking; store dry indoor on drum supports, shaded, avoid direct UV. Est. OD/weight/ampacity/short-circuit confirmed against the factory certificate; ZC is flame retardant, not 950°C fire-rated.


8. Factory Advantages.

  • Balanced 3+1 sizing — 3×50 phases with 1×25 neutral, cost-effective on motor loads.
  • Stable XLPE cure — even cross-linking withstands motor start-stop cycles.
  • Dosed ZC compound — self-extinguishing jacket protects machine rooms.
  • Length-on-demand — exact machine/branch meter, sealed ends.
  • Dual-section resistance log — phase 50 and neutral 25 R logged to lot.
  • Continuous print line — type, size, ZC, voltage and length along jacket.
  • Phase-color option — L1/L2/L3/N colors matched to convention.
  • Compact drum pack — standard wooden drum with sealed ends.
  • Certified QA pack — routine + type test record per batch.

OEM Copper Xlpe Cable 4 Core Heat Resistant Flex 3×50mm2+1×25mm2 For Heavy Duty


9. Packaging, Storage & Logistics. Cut to measured branch length on a standard wooden drum with sealed ends; continuous marking; store dry indoor on drum supports, shaded, avoid direct UV.


OEM Copper Xlpe Cable 4 Core Heat Resistant Flex 3×50mm2+1×25mm2 For Heavy Duty


10. Procurement Specification. State "ZC-YJV 3×50+1×25", length, class C, phase colors, braid screen for VFD if required, drum; note reduced neutral for balanced motors and not fire-rated; request dual-section resistance log and 16-item QA record. Est. values confirmed against the factory certificate.


11. Cable Industry FAQ.

  • Q1: How does 3×50+1×25 differ from 4×300? Compact 3+1 branch vs four equal heavy mains: much smaller (50/25 vs 300 mm²), slimmer (16 vs 42 mm), far lighter (1450 vs 9800 kg/km), much lower current (120 vs 510 A), and higher resistance (0.387/0.741 vs 0.0601 Ω/km). It runs motor branches, not busbar risers.
  • Q2: Why a reduced 25 mm² neutral? Balanced three-phase motors draw little neutral current, so a 25 mm² neutral saves copper; enlarge it where VFD/rectifier harmonics are high.
  • Q3: Is ZC fire-resistant? No. Class C self-extinguishes; it does not hold live at 950°C/180min.
  • Q4: DC resistance values? Phase 50 ≤0.387 Ω/km; neutral 25 ≤0.741 Ω/km at 20°C.
  • Q5: Braid screen or armor? Unscreened standard; add braid screen near VFD EMI and armor for ground-crushing ducts.
  • Q6: Current per phase? ≈ 120 A (est.) free air 30°C; derate in conduit and crowded trays.
  • Q7: Bending? ≥ 240 mm (15×OD); compact enough for panel-to-machine routing.
  • Q8: Connectors? 50 mm² phase lugs, 25 mm² neutral lug, gland to ≈16 mm OD.
  • Q9: Indoor or outdoor? Indoor machine rooms preferred; UV jacket for exposed outdoor runs.
  • Q10: Packing? Standard wooden drum with sealed ends.
  • Q11: What proof ships? Dual-section resistance log + 16-test record; est. values confirmed against certificate.