logo
Anhui Tongdu International Trade Co., Ltd.
Online Service

Online Service

Contact Person
+86 19056002718
WeChat QR Code
Follow Us

1*25mm² Single Core Cable, 0.6/1kV XLPE Insulation PVC Sheath for Indoor Power Wiring

1*25mm² Single Core Cable, 0.6/1kV XLPE Insulation PVC Sheath for Indoor Power Wiring

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
ZR-YJV 1*25mm²

Trading Properties

moq
100 meters
payment method
L/C,T/T
supply capacity
100000 meters per month

Product Summary

ZR-YJV 1*25mm² Flame Retardant Single Core Cable, 0.6/1kV Pure Copper XLPE Insulation PVC Sheath for Indoor Power Wiring ZR-YJV 1×25 mm² — Detailed Product Introduction Cable Designation & Meaning Code Meaning ZC Flame retardant C— IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) ...

Product Details

Highlight:

1x25mm2Single Core Cable

,

Single Core Cable 316kg/km

,

Power Wiring Pure Copper Cable

Conductor​:
Bare Annealed Copper, Class 2 Stranded Circular, 7×∅2.07 Mm​ (typical), Conductor Ø ≈ 6.2 Mm
Conductor nominal area:
25 Mm²
Conductor construction:
Class 2, 7×∅2.07 Mm​ Min. 7 Wires Per GB/T 3956 (≤35 Mm²)
Conductor diameter (approx.):
6.2 Mm
Insulation:
XLPE Compound, Extruded
Insulation thickness (nominal):
0.9 Mm​ (GB/T 12706.1, 25 Mm² Class)
Diameter over insulation (approx.):
8.0 Mm(6.2 + 2×0.9)
Sheath nominal thickness:
1.4 Mm,single-core (some Makers 1.5)
Filler / binder​:
Flame-retardant (FR) Non-hygroscopic Tape / PP Mesh
Outer sheath​:
Polyolefin (PO) Compound, Flame-retardant Grade (ZR)
Overall cable diameter:
10.7 – 11.8 Mm
Approx. weight:
280 – 316 Kg/km
Long-term service temperature:
90 °C
Short-circuit temperature (≤5 s):
250 °C
Emergency overload:
105–130 °C (limited Duration)
Routine test:
3.5 KV AC / 5 Min; Type Test 4.0 KV
Volume resistivity @90 °C:
≥ 10¹² Ω·cm
Insulation resistance constant:
≈ 3.67 MΩ·km @90 °C

Product Description

ZR-YJV 1*25mm² Flame Retardant Single Core Cable, 0.6/1kV Pure Copper XLPE Insulation PVC Sheath for Indoor Power Wiring

ZR-YJV 1×25 mm² — Detailed Product Introduction

Cable Designation & Meaning

Code

Meaning

ZC

Flame retardant C— IEC 60332-3-24, Category C

YJ

Cross-linked polyethylene (XLPE) insulation

V

PVC sheath

1×25 mm²

Single core, 25 mm² copper conductor


Construction: Single Class 2 stranded copper conductor, XLPE insulation, PVC outer sheath (no armour, no shield).


1*25mm² Single Core Cable, 0.6/1kV XLPE Insulation PVC Sheath for Indoor Power Wiring

ZC-YJV 1×25 mm² — LV Flame-Retardant Power Cable — Specification 

1. Overview & Ratings. ZC-YJV 1×25 is a compact single-core LV power cable rated 0.6/1 kV (Um 1.2), 90 °C working, ZC class C flame-retardant PVC sheath. One compacted 25 mm² copper core, dry-cured XLPE, unscreened. OD ≈ 11.0 mm, ≈ 320 kg/km, ≈ 95 A (air, 30 °C). Scope: branch feeds, lighting drops, short socket runs, panel internal wiring — not 950°C circuit-integrity fire duty.


2. Construction Stack (Inner → Outer).


Layer Build Function
Conductor 1×25 compacted Cu, Class 2, ≈7 strands Power core
XLPE insulation Dry-cured cross-linked PE, ≈0.9 mm 90 °C dielectric
PVC ZC sheath Flame-retardant class C, ≈1.3 mm Protection, self-extinguish


3. Electrical Characteristics. Core R ≤ 0.741 Ω/km @20 °C. Test 3.5 kV AC / 5 min; nominal ≈ 95 A (air, 30 °C); short-circuit ≈ 2.2 kA / 1 s; 50/60 Hz; unscreened; low-loss XLPE; insulation resistance high and stable.

Insulation & Sheath Data

Property

Value

Insulation material

XLPE (cross-linked polyethylene)

Outer sheath material

PVC (ST₂)

Long-term service temp.

90 °C (continuous)

Max. conductor temp. (normal)

90 °C

Short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Test voltage AC (5 min)

3.5 kV

Dielectric strength

≥ 20 kV/mm

Volume resistivity @20 °C

≥ 1×10¹⁴ Ω·cm

Shield

None as standard (can be added)

Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

GB/T 12706.1 / IEC 60502-1

Max. system voltage

1.2 kV AC

—

Test voltage AC (5 min)

3.5 kV

Routine test

DC resistance @20 °C

≤ 0.727 Ω/km

GB/T 3956 Class 2 Cu max

AC resistance @90 °C (est.)

≈ 0.933 Ω/km

—

Current rating in air (30 °C)

Phase: 120 A​

single-core, touching, in free air

Current rating in tray (30 °C)

Phase: 135 A​

single-core, spaced 2×OD

Current rating buried in ground (20 °C, thermal resistivity 1.2 K·m/W)

Phase: 125 A​

direct buried

Current rating in conduit (30 °C)

Phase: 110 A​

—

Short-circuit current (1 s, Cu, 250 °C)

≈ 2.8 kA (2,800 A)

—

Capacitance (core-to-sheath, approx.)

≈ 0.14 µF/km

XLPE

Inductive reactance (approx.)

≈ 0.07 Ω/km

at 50 Hz

Frequency

50/60 Hz AC

—


Reference values: 1×25 at 120 A, single-phase 230 V → max load ≈ 27 kW​ (cos φ = 0.8). Suitable for control circuits, instrumentation, and small equipment connections.


4. Thermal & Flame. 90 °C continuous, 250 °C short-time; ZC class C self-extinguishing on flame removal — flame retardancy, not 950°C integrity; withstands repeated 0~90°C cycles; indoor/tray/conduit; UV grade if exposed.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

90 °C (continuous)

Max. short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Min. installation ambient temp.

0 °C (below 0 °C requires preheating)

Service ambient range

−20 °C to +90 °C

Flexing temp. range

0 °C to +90 °C

Fire Performance (ZC-YJV — Flame Retardant C)

Property

Value / Requirement

Flame retardant

GB/T 18380.12 / IEC 60332-1-2​ (single cable, self-extinguishing)

Flame retardant class

Class C​ (ZC) per GB/T 19666

Halogen content

Contains halogen (PVC sheath)

Smoke density

Not low-smoke (PVC)

Corrosivity

Corrosive (PVC)

Toxicity

Toxic fumes when burned (PVC)

EMI shielding

None (no metallic screen/armour)


5. Installation Practice & Handling. Standard Cu lugs and glands; strip → crimp → torque per table; bend ≥ 15×OD ≈ 165 mm; derate in bundled conduit/tray; light reel suits short branch and drop pulls; continuity and insulation after laying; cold bending not below 0 °C.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 15 × OD → ≈ 180 mm at Ø12.0 mm

single-core unarmoured

Max. pulling tension

375 N (25 mm² × 15 N/mm²)

Cu conductor limit

Direct burial

Suitable (with sand bedding)

—

Surface mounting

Excellent (cable tray, ladder, cleats)

—

Conduit ID

≥ 16 mm

—

Fixing

cable ties, cleats

—

Impact resistance

Moderate

—

Water resistance

Good (PVC sheath)

—

UV resistance

Fair (PVC degrades outdoors, use UV-resistant PVC or conduit)

—

Flex life

Good (Class 2 stranded)

fixed installation

Termination note

Standard compression lugs or mechanical connectors

—


6. Typical Service Applications. Branch feeds, lighting drops, short socket ring runs, small power taps, panel internal wiring, trunking drops, general indoor LV circuits.


1*25mm² Single Core Cable, 0.6/1kV XLPE Insulation PVC Sheath for Indoor Power Wiring


7. Testing & QA Regime (16 items). Routine: DC resistance, 3.5 kV withstand, insulation resistance, continuity, sheath/insulation thickness, dimensional check, conductor construction, insulation eccentricity, sheath appearance, printing legibility, mass per unit length. Type: ZC class C flame test, short-circuit rating, sheath tensile/elongation, 0~90°C temperature cycle.


Cable Parameters


ZC-YJV 1×25 mm² — LV Flame-Retardant Power Cable — Full Parameter Sheet
Cu / XLPE / PVC · ZC class C · 0.6/1 kV · ≈ 11.0 mm · branch feed, lighting drop, control-power, panel internal & short socket run
Parameter Value Unit Remarks / Standard
01 · Identification
Cable type ZC-YJV — Cu / XLPE / PVC, flame-retardant class C — LV power
Rated voltage (U0/U) 0.6/1 kV Low voltage
Maximum operating voltage (Um) 1.2 kV Phase-to-earth
Core configuration 1×25 — Single core
Conductor material Compacted stranded annealed copper — Class 2
Insulation XLPE cross-linked polyethylene — 90°C
Sheath PVC, flame-retardant class C (ZC) — Steel slate-blue
Flame retardancy ZC class C (self-extinguishing, not fire-rated) — Flame retardant
Suitable for Fixed indoor wiring, tray, conduit, trunking, panel — Power
Application Branch feed, lighting drop, short socket run — General
Application note Not for 950°C circuit-integrity fire duty — Scope
02 · Conductors
Power core 1 × 25 mm² Single
Conductor type Compacted stranded Cu, Class 2 — Round
DC resistance (25) @ 20°C ≤ 0.741 Ω/km Cu 25
Stranding Layer-compacted, concentric — Stable OD
Strands (nom., est.) ≈ 7 compacted — Class 2
Surface Bare copper, tinned optional — Contact
Nominal area tolerance Within conductor class 2 band — Standard
03 · Insulation
Insulation material XLPE (cross-linked PE) — 90°C rated
Insulation thickness (nom.) ≈ 0.9 mm Single-core
Working conductor temp. 90 °C Normal
Short-circuit temp. 250 °C Max, short time
Insulation resistance High and stable MΩ·km XLPE
Color Natural / phase color on request — Identification
Cure type Chemical / dry-cured XLPE — Dielectric
04 · Sheath & Flame Retardancy
Sheath material PVC, flame-retardant ZC — Class C
Sheath thickness (nom.) ≈ 1.3 mm Overall
Finished outer diameter ≈ 11.0 mm Single core
Flame behavior Self-extinguishing, class C — Not 950°C fire-rated
Sheath color Steel slate-blue (other on request) — Marking
Surface finish Smooth, continuous print — Appearance
05 · Electrical
Rated voltage (U0/U) 0.6/1 kV LV
Max voltage (Um) 1.2 kV Phase-to-earth
Nominal current (25 core) ≈ 95 A Air, 30°C
Test voltage (AC) 3.5 kV / 5 min — Routine
Insulation resistance High, XLPE MΩ·km Stable
Short-circuit current (25, 1s) ≈ 2.2 kA Copper
Frequency 50 / 60 Hz General
Dielectric XLPE, low loss — Stable
06 · Thermal & Environment
Normal conductor temp. 90 °C Continuous
Installed ambient 0 ~ +40 °C Indoor/tray
Min install temp. 0 °C Cold bending
Burning Self-extinguishing, ZC class C — Flame retardant
Outdoor / UV Indoor preferred; use UV grade if exposed — PVC limit
Oil / chemicals Resistant to common oils; check aggressive media — General
Temperature cycle Withstands repeated 0~90°C duty — Durability
07 · Mechanical & Construction
Min bending radius (fixed) ≥ 15 × OD ≈ 165 mm Single-core
Flexibility Flexible stranded, compact, easy to pull — Handy
Shielding None (unscreened power) — General
Cable weight per km ≈ 320 kg/km Light Cu core
Circularity Compacted round, stable OD — Conduit fit
Tensile / elongation Sheath meets PVC grade — Mechanical
08 · Factory Advantages
Fine compacted core Small strand bundle lays round for tight conduit — Easy route
Stable XLPE cure Even cross-linking, consistent 90°C dielectric — Reliable insulation
Dosed ZC compound Flame-retardant PVC self-extinguishes to class C — Safety margin
Length-on-demand Cut to exact meter, sealed ends, minimal offcut — No waste
Batch resistance log Per-core DC R recorded against lot number — Traceable
Continuous print line Voltage, size, ZC, meter length along jacket — Clear ID
Phase-color option Insulation/jacket color matched to phase code — Fast wiring
Light & hand-pull 320 kg/km reel suits short branch & drop pulls — Fast install
Dual pack choice Drum or coil to match job quantity — Flexible delivery
09 · Installation
Laying Tray, conduit, trunking, branch feed — Power
Connectors Cu lugs, standard glands — General
Bend radius ≥ 15×OD ≈ 165 mm — Single-core
Parallel runs Derate when bundled in conduit/tray — Load
Site test Continuity + insulation post-laying — Commissioning
Termination Strip insulation, crimp lug, torque per table — Reliable joint
10 · Packing & Applications
Supply length Custom / wooden drum or coil m Light
Length tolerance Per trade standard for cut lengths — Delivery
Reel type Standard wooden drum / coil — Handy
Surface marking ZC-YJV, 1×25, 0.6/1kV, ZC, length — Marking
Typical use Branch feed, lighting drop, short socket run — Power
Storage Dry indoor, avoid direct UV — Preservation


Cable Test Parameters


Test Parameters — ZC-YJV 1×25 LV Flame-Retardant Cable
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance 20 °C, core 25 ≤0.741 Ω/km Routine
2 Voltage test (AC) 3.5 kV AC, 5 min No breakdown Routine
3 Insulation resistance XLPE, 20°C High & stable Routine
4 Continuity Core Continuous Routine
5 Flame retardancy Class C vertical test Self-extinguish Type
6 Sheath thickness Micrometer Nominal ≥1.3 mm Routine
7 Insulation thickness Micrometer Nominal ≥0.9 mm Routine
8 Dimensional check Caliper OD ≈ 11.0 mm Routine
9 Conductor construction Visual / strand count Class 2 compacted Routine
10 Short-circuit rating Calculated / type 2.2 kA / 1 s Type
11 Insulation eccentric test Cross-section measure Within tolerance Routine
12 Sheath appearance Visual Smooth, no flaw Routine
13 Printing legibility Visual Marking readable Routine
14 Mass per unit length Weigh / calculate ≈ 320 kg/km Routine
15 Sheath mechanical Tensile / elongation check Meets PVC grade Type
16 Temperature cycle Repeated 0~90°C duty No cracking Type


Cable Cross Section Structure


1*25mm² Single Core Cable, 0.6/1kV XLPE Insulation PVC Sheath for Indoor Power Wiring


ZC-YJV 1×25 — Cross-Section Construction Diagram (Schematic)
Cu core / XLPE insulation / PVC ZC sheath · 0.6/1 kV · ZC class C · ≈ 11.0 mm · branch feed, lighting drop, short socket run
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor 1×25 compacted Cu, Class 2, ≈7 strands — ≈ 7 Power core
2 XLPE insulation Cross-linked PE, dry-cured ≈ 0.9 ≈ 9.2 90°C dielectric
3 PVC sheath ZC flame-retardant, smooth ≈ 1.3 ≈ 11.0 Protection
Key Dimensions & Properties (expanded)
Finished cable diameter ≈ 11.0 mm Single core
Approx. cable mass ≈ 320 kg/km Light Cu core
Nominal voltage rating 0.6/1 kV LV
Max voltage (Um) 1.2 kV Phase-earth
Normal conductor temp. 90 °C Continuous
Short-circuit temp. 250 °C Short time
Flame retardancy ZC class C, self-extinguishing — Not fire-rated
Min bending radius (fixed) ≥ 15 × OD ≈ 165 mm Single-core
DC resistance (25) ≤ 0.741 Ω/km Cu 25
Nominal current (25 core) ≈ 95 A Air, 30°C
Short-circuit rating (1s) ≈ 2.2 kA 25 Cu
Frequency 50 / 60 Hz General
Temperature cycle 0~90°C repeated — Durability
Pack choice Drum or coil — Flexible
Core configuration 1×25 — Single
Application Branch feed, lighting drop, short socket — Power
Schematic — not to exact scale. OD ≈11.0 mm and weight ≈320 kg/km from cross-referenced industry samples. ZC-YJV 1×25 serves branch feeds, lighting drops and short socket runs; ZC class C self-extinguishes but is not 950°C fire-rated. Values marked (est.) require confirmation against the factory test certificate.


Cable Construction Description


Construction Description — ZC-YJV 1×25 LV flame-retardant power cable
Cu core / XLPE insulation / PVC ZC sheath · 0.6/1 kV · ZC class C · 90°C · ≈11.0 mm · branch feed, lighting drop, short socket
1. Product Identity & Ratings
ZC-YJV 1×25 rated 0.6/1 kV (Um 1.2), 90°C working, ZC class C. OD ≈11.0 mm, ≈320 kg/km, ≈95 A, drum or coil.
2. Copper Conductor (1×25)
Single 25 mm² compacted Class 2 Cu, ≈7 strands; DC R ≤0.741 Ω/km @20°C; tinned optional; area within class-2 band.
3. XLPE Insulation
Dry-cured cross-linked PE ≈0.9 mm, stable 90°C dielectric; short-circuit 250°C; phase color on request.
4. PVC ZC Sheath
Flame-retardant PVC ≈1.3 mm, self-extinguishing class C; smooth steel slate-blue; indoor/tray; UV grade if exposed.
5. Factory Advantages
• Fine compacted round core.  • Stable XLPE cure.  • Dosed ZC self-extinguish.  • Cut to exact meter.  • Per-batch resistance log.  • Continuous clear print.  • Phase-color option.  • Light & hand-pull.  • Dual drum/coil pack choice.
6. Site Handling Notes
• Bend 15×OD (≈165 mm).  • Cu lugs, standard glands.  • Derate in conduit.  • Strip/crimp/torque per table.  • Indoor; UV grade if exposed.  • Continuity + insulation after laying.


8. Factory Advantages.

  • Fine compacted core — the small strand bundle lays round for a tight conduit fit.
  • Stable XLPE cure — dry-cured, even cross-linking keeps the 90°C dielectric consistent lot to lot.
  • Dosed ZC compound — flame-retardant PVC self-extinguishes to class C with a safety margin.
  • Length-on-demand — cut to the exact meter with sealed ends and minimal offcut.
  • Batch resistance log — per-core DC R recorded against the lot number for traceability.
  • Continuous print line — voltage, size, ZC, and meter length marked along the jacket.
  • Phase-color option — insulation or jacket color matched to the phase code for fast wiring.
  • Light & hand-pull — at 320 kg/km the reel suits short branch and drop pulls.
  • Dual pack choice — drum or coil to match the job quantity and site access.

1*25mm² Single Core Cable, 0.6/1kV XLPE Insulation PVC Sheath for Indoor Power Wiring


9. Packaging, Storage & Logistics. Standard wooden drum or coil; length per trade tolerance; continuous marking (ZC-YJV, 1×25, 0.6/1kV, ZC, length). Store dry indoor, avoid direct UV.


1*25mm² Single Core Cable, 0.6/1kV XLPE Insulation PVC Sheath for Indoor Power Wiring


10. Procurement Specification. State "ZC-YJV 1×25", length, class C, phase color, and pack (drum/coil); note it is flame retardant, not fire-rated; request the per-batch resistance log and 16-item QA record.



ZC-YJV 1×25 mm² Power Cable
Frequently Asked Questions (FAQ)
Flame-Retardant Class C · XLPE Insulated · PVC Sheathed · Copper Conductor · 0.6/1 kV

Product Basics

Q1. What does the model “ZC-YJV” mean?
“Z” stands for flame-retardant, “C” denotes Class C flame-retardant performance, “YJ” means XLPE (cross-linked polyethylene) insulation, and “V” means PVC sheath. ZC-YJV is a copper-core, Class C flame-retardant, XLPE-insulated, PVC-sheathed low-voltage power cable.
Q2. What does “1×25 mm²” indicate?
“1” means a single-core cable. “25 mm²” is the nominal cross-sectional area of the copper conductor. This size is widely used for main branch circuits, small motor feeders, and distribution board incoming lines in buildings and industrial plants.
Q3. What is the rated voltage?
The rated voltage U₀/U is 0.6/1 kV (0.6 kV phase-to-earth, 1 kV phase-to-phase), suitable for low-voltage power transmission and distribution systems.
Q4. What materials are used in construction?
Conductor: plain copper, Class 2 stranded. Insulation: cross-linked polyethylene (XLPE). Outer sheath: flame-retardant PVC. The standard ZC-YJV is unarmored. For direct burial or areas requiring mechanical protection, choose armored variants such as ZC-YJV22 (steel tape armor).

Technical Specifications

Q5. What is the maximum operating temperature?
The maximum continuous conductor temperature is 90 °C. During short-circuit events, the conductor may reach up to 250 °C for no more than 5 seconds. XLPE insulation delivers a higher temperature rating and greater current-carrying capacity than traditional PVC-insulated cables.
Q6. What is the typical current-carrying capacity?
For a 1×25 mm² copper XLPE cable, the ampacity is approximately 110–135 A when installed in free air at 30 °C ambient. Lower values apply when buried, grouped with other cables, or at higher ambient temperatures. For precise engineering design, refer to the manufacturer's ampacity tables (GB/T 16895 / IEC 60364) and apply appropriate derating factors.
Q7. What is the conductor DC resistance?
The maximum DC resistance of a 25 mm² Class 2 copper conductor at 20 °C is approximately 0.741 Φ/km (annealed copper), per GB/T 3956 / IEC 60228. The exact value should be confirmed from the factory test report for each batch.

Installation & Applications

Q8. What is the minimum bending radius?
For single-core unarmored cables, the minimum bending radius is 15–20 times the cable outer diameter (15D–20D) during installation. Do not exceed the recommended bending radius to avoid damage to the insulation and sheath. D = actual outer diameter of the cable.
Q9. What are the typical applications?
Common uses include: main branch circuits in commercial and residential buildings; power supply to small-to-medium motors, pumps, and HVAC equipment; distribution board feeders; and secondary power distribution in industrial facilities where Class C flame-retardant performance is required by the electrical code.
Q10. Which standards and certifications apply?
Manufactured in accordance with GB/T 12706 (equivalent to IEC 60502), with conductor compliance to GB/T 3956 / IEC 60228 and flame-retardant testing per GB/T 18380 / IEC 60332-3. Common certifications include CCC (China), CE (Europe), ISO 9001 quality management, RoHS, and VDE/TUV for specific export markets.