1x16mm2 Single Core Electrical Cable Oxygen Free Self Extinguishing 1 Core 16mm Cable

1x16mm2 Single Core Electrical Cable Oxygen Free Self Extinguishing 1 Core 16mm Cable

Basic Properties

country of origin
China
brand name
TD
certificate
CE/ISO/CCC
product model
ZR-YJV 1*16mm²

Trading Properties

moq
100 meters
payment method
L/C,T/T
supply capacity
100000 meters per month

Product Summary

ZR-YJV 1*16mm² Flame Retardant Single Core Power Cable, 0.6/1kV, Oxygen-Free Copper, XLPE Insulation, PVC Sheath, Self-extinguishing, for Indoor Building Power Distribution. Code Mean: ZR-Flame Retardant YJ-XLPE Insulation V-PVC Outer Sheathed Flame-retardant copper-conductor, XLPE-insulated, PVC...

Product Details

Highlight:

1x16mm2 single core electrical cable

,

single core electrical cable Oxygen Free

,

Self extinguishing 1 core 16mm cable

Conductor​:
Bare Annealed Copper, Class 2 Stranded Circular, 7×∅1.66 Mm​ (typical), Conductor Ø ≈ 5.0 Mm
Conductor nominal area:
16 Mm²
Conductor construction:
Class 2, 7×∅1.66 Mm
Conductor diameter (approx.):
5.0 Mm
Insulation​:
XLPE Compound, Extruded (natural/black/coloured On Request)
Insulation thickness (nominal)​:
0.7 Mm​ (GB/T 12706.1, 10/16 Mm² Class)
Diameter over insulation (approx.):
6.4 Mm(5.0 + 2×0.7)
Sheath nominal thickness:
1.4 Mm(single-core ≤16 Mm²)
Sheath thickness (nominal):
1.4 Mm​ (single-core, ≤16 Mm²)
Filler / binder​:
Flame-retardant (FR) Non-hygroscopic Tape / PP Mesh
Overall cable diameter:
9.0 – 10.1 Mm
Approx. weight:
193 – 221 Kg/km
Long-term service temperature:
90 °C
Short-circuit temperature (≤5 s):
250 °C
Emergency overload:
105–130 °C (limited Duration)
Routine test:
3.5 KV AC / 5 Min; Type Test 4.0 KV
Volume resistivity @90 °C:
≥ 10¹² Ω·cm
Insulation resistance constant:
≈ 3.67 MΩ·km @90 °C

Product Description

ZR-YJV 1*16mm² Flame Retardant Single Core Power Cable, 0.6/1kV, Oxygen-Free Copper, XLPE Insulation, PVC Sheath, Self-extinguishing, for Indoor Building Power Distribution.

 

Code Mean:

ZR-Flame Retardant

YJ-XLPE Insulation

V-PVC Outer Sheathed

 

Flame-retardant copper-conductor, XLPE-insulated, PVC-sheathed power cable · Construction: CU / XLPE / PVC · Standards: GB/T 12706.1, IEC 60502-1; conductor GB/T 3956; flame retardance GB/T 19666 & GB/T 18380.


1. Product Structure (from conductor to outer sheath)

Layer Material Nominal Thickness Resulting Diameter
1. Conductor Plain annealed copper (Cu), Class 2 stranded — typical construction 7 wires × 1.70 mm (7/1.70), nominal section 16 mm² — ≈ 5.0 mm
2. Insulation Cross-linked polyethylene (XLPE) — thermally cross-linked, natural/transparent colour 0.7 mm ≈ 6.4 mm
3. Outer sheath Flame-retardant PVC (ST2 type), black (or as ordered) 1.4 mm ≈ 9.3 mm overall

The cable is a single concentric construction: the stranded copper conductor carries the current; the XLPE insulation provides the dielectric barrier (high insulation resistance, low dielectric loss, 90 °C continuous rating); the flame-retardant PVC sheath gives mechanical, moisture and environmental protection and provides the ZR flame-retardant property.

2. Product Performance

  • Electrical — Max. DC conductor resistance at 20 °C ≤ 1.15 Ω/km (GB/T 3956, Class 2); power-frequency withstand test 3.5 kV AC / 5 min, no breakdown; finished-cable insulation resistance at 20 °C typically ≥ 36.7 MΩ·km (manufacturer reference; XLPE volume resistivity ≥ 1×10¹² Ω·cm) 
  • Thermal — Max. continuous conductor temperature 90 °C; max. short-circuit conductor temperature (≤ 5 s) 250 °C; ambient service range −20 to +45 °C; minimum installation temperature 0 °C (preheat below 0 °C) .
  • Flame retardance — "ZR" per GB/T 19666; when no A/B class is stated the default is class C (ZC): single-cable vertical flame-spread test per GB/T 18380.12; bunched test per GB/T 18380.35 (non-metallic volume ≥ 1.5 L/m, 20 min flame, char extent ≤ 2.5 m) 
  • Mechanical / dimensional — Approx. overall diameter 9.0–9.3 mm; approx. weight ≈ 201 kg/km (manufacturer range 195–220 kg/km); minimum bending radius (single-core) 20 × OD 
  • Ampacity (reference) — ≈ 115 A in air at 30 °C (single core) and ≈ 100–115 A direct-buried; final ratings need derating factors for ambient, grouping and laying method (GB/T 16895 / IEC 60364) 

1x16mm2 Single Core Electrical Cable Oxygen Free Self Extinguishing 1 Core 16mm Cable

3. Product Parameters

ZR-YJV 1×16 mm² Flame-Retardant Copper-Conductor XLPE-Insulated PVC-Sheathed Power Cable — Product Parameters (0.6/1 kV)
Construction: CU / XLPE / PVC  •  Standards: GB/T 12706.1, IEC 60502-1 (cable), GB/T 3956 (conductor), GB/T 19666 & GB/T 18380 (flame retardance)  •  Nominal values for reference — confirm against factory test certificate
No. Category Parameter Value Unit Notes / Standard Reference
A. Product Identification
1 Identification Product name Flame-retardant copper-conductor XLPE-insulated PVC-sheathed power cable — Designation ZR-YJV; "ZR" = flame-retardant 
2 Identification Model designation ZR-YJV 1×16 — Cu / XLPE / PVC
3 Identification Design standards GB/T 12706.1; IEC 60502-1 — Conductor: GB/T 3956 / IEC 60228; flame retardance: GB/T 19666, GB/T 18380; safety: CCC / production licence
4 Identification Rated voltage U0/U 0.6/1 kV U0 = voltage conductor-to-earth; U = conductor-to-conductor; max system voltage Um = 1.2 kV
5 Identification Rated frequency 50 Hz AC power distribution
6 Identification Number of cores 1 — Single-core cable
7 Identification Nominal cross-sectional area 16 mm² Nominal conductor cross-section per GB/T 3956
B. Cable Construction (from conductor to outer sheath)
8 Conductor Material Plain annealed copper (Cu) — High-conductivity electrolytic / oxygen-free copper
9 Conductor Conductor class Class 1 or Class 2 (typical: Class 2, stranded) — GB/T 3956 / IEC 60228; Class 2 for flexible stranding and bending
10 Conductor Typical stranding construction 7 wires × 1.70 mm (7/1.70) — Class 2 round stranded; nominal section ≈ 16 mm²
11 Conductor Conductor diameter ≈ 5.0 mm 5.0–5.1 mm per manufacturer tables (Qifan 5.0 mm; Hydget 5.1 mm)
12 Conductor Max. DC resistance of conductor at 20 °C 1.15 Ω/km GB/T 3956, Class 2 copper; acceptance criterion for 16 mm²
13 Insulation Material Cross-linked polyethylene (XLPE) — Thermally cross-linked; natural/transparent colour
14 Insulation Nominal insulation thickness 0.7 mm GB/T 12706.1 / IEC 60502-1 (Table for 0.6/1 kV, 16 mm²)
15 Insulation Diameter over insulation ≈ 6.4 mm ≈ 5.0 + 2 × 0.7 (calculated)
16 Sheath Material Flame-retardant polyvinyl chloride (PVC, ST2 type) — Flame-retardant PVC compound; colour: black (or as ordered)
17 Sheath Nominal sheath thickness 1.4 mm GB/T 12706.1 / IEC 60502-1
18 Dimensions Approx. overall diameter 9.0–9.3 mm Qifan 9.3 mm; Weiguang 9.0 mm; max. ≤ 12.0 mm per some manufacturers
19 Dimensions Approx. cable weight ≈ 201 kg/km Range 195–220 kg/km across manufacturers (Qifan 201; Weiguang 195; Gongyi Shengzhou 220)
C. Electrical Performance
20 Electrical Max. DC conductor resistance at 20 °C ≤ 1.15 Ω/km GB/T 3956; routine measurement
21 Electrical Power-frequency withstand voltage (routine test) 3.5 kV / 5 min, no breakdown — AC 50 Hz; per GB/T 12706.1 / IEC 60502-1
22 Electrical Insulation resistance (finished cable, 20 °C) ≥ 36.7 MΩ·km Typical finished-cable requirement quoted for 0.6/1 kV XLPE cables; varies with geometry and manufacturer test method
23 Electrical XLPE volume resistivity at 20 °C ≥ 1 × 10¹² Ω·cm Material-level requirement (manufacturer reference)
24 Electrical Capacitance (single-core, approx.) ≤ 0.45 μF/km Manufacturer reference value
25 Electrical Reference ampacity — in air, 30 °C, single core ≈ 115 A Reference value (Guangheng); depends on laying, grouping, ambient — apply correction factors per GB/T 16895 / IEC 60364
26 Electrical Reference ampacity — direct burial, 25 °C ≈ 100–115 A Reference value; depends on soil thermal resistivity and depth
D. Thermal Performance
27 Thermal Max. continuous conductor temperature 90 °C XLPE insulation temperature class
28 Thermal Max. conductor temperature under short-circuit (≤ 5 s) 250 °C Per GB/T 12706.1 / IEC 60502-1
29 Thermal Ambient service temperature range -20 to +45 °C Per Qifan datasheet; check project specification
30 Thermal Min. installation (laying) temperature 0 °C Pre-heat the cable if ambient is below 0 °C
E. Flame Retardance (ZR)
31 Flame retardance Flame-retardant class ZC (class C) by default for "ZR" — GB/T 19666; ZA / ZB available on request; halogen-containing PVC (not LSZH)
32 Flame retardance Single-cable vertical flame-spread test Pass — GB/T 18380.12; no flame spread beyond specified point
33 Flame retardance Bunched flame-spread test (class C) Char extent ≤ 2.5 m above burner bottom edge — GB/T 18380.35: non-metallic volume ≥ 1.5 L/m; flame application 20 min
34 Flame retardance Halogen content Halogen-containing (PVC) — For low-smoke, zero-halogen requirement select WDZ-YJY (LSZH) type
F. Installation
35 Installation Min. bending radius — single-core cable 20 × OD — Qifan & Huaneng datasheets; some manufacturers specify 15 × OD; OD = actual cable diameter
36 Installation Laying methods Conduit, tray, cable trench, tunnel, duct, supported/suspended aerial — Also direct burial with mechanical protection where permitted
37 Installation Site withstand test after installation DC 4U0 = 2.4 kV, 15 min (recommended) — Per utility procurement standard Q/GDW 13244.1-2018; practice may vary by project
G. Packing & Delivery
38 Packing Standard delivery length 100 m per coil/drum (or as ordered) — Typical industry practice; custom lengths available
39 Packing Cable marking Model, rated voltage, manufacturer, year of manufacture, sequential length marks — Per GB/T 6995 / project specification
40 Packing Packing form Wooden drum / coil / export packing — As per customer requirement

 

1x16mm2 Single Core Electrical Cable Oxygen Free Self Extinguishing 1 Core 16mm Cable

4.Cable Cross-Section Diagram

1x16mm2 Single Core Electrical Cable Oxygen Free Self Extinguishing 1 Core 16mm Cable

 

ZR-YJV 1×16 mm² — Cable Cross-Section Structure (Schematic)
Layers from conductor to outer sheath · nominal values per GB/T 12706.1 / IEC 60502-1 · not to exact scale
           
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor (Cu) Annealed copper, Class 2 stranded — 7 × 1.70 mm (7/1.70), nominal 16 mm² — ≈ 5.0 (Ø) Current-carrying element; max DC resistance ≤ 1.15 Ω/km @ 20 °C
2 Insulation (XLPE) Cross-linked polyethylene 0.7 ≈ 6.4 (Ø over insulation) Dielectric barrier; rated 90 °C continuous; withstands 3.5 kV / 5 min
3 Outer sheath (PVC) Flame-retardant PVC, ST2 type, black 1.4 ≈ 9.3 (Ø overall) Mechanical & moisture protection; flame retardance ZC (ZR) per GB/T 19666
           
Key Dimensions & Properties
Overall diameter 9.0–9.3 mm Max ≤ 12.0 mm per some manufacturers    
Approx. cable weight ≈ 201 kg/km Range 195–220 kg/km across manufacturers    
Rated voltage 0.6/1 kV AC 50 Hz; max system voltage Um = 1.2 kV    
Max conductor temperature 90 / 250 °C Continuous / short-circuit (≤ 5 s)    
Min. bending radius (single-core) 20 × OD — OD = actual cable diameter    
Flame-retardant class ZC (ZR) — GB/T 19666    

 

5.Test Parameters

ZR-YJV 1×16 mm² — Test / Verification Parameters (per GB/T 12706.1 & IEC 60502-1)
Test Stage Test Item Method / Standard Requirement / Acceptance Criterion Notes
Routine test Conductor DC resistance measurement GB/T 3956 (IEC 60228) ≤ 1.15 Ω/km at 20 °C Measured on every production length
Routine test Power-frequency withstand voltage GB/T 12706.1 / IEC 60502-1 3.5 kV AC, 5 min, no breakdown Applied between conductor and water/earth; 50 Hz
Routine test Construction check — insulation & sheath thickness, outer diameter GB/T 2951 Within GB/T 12706.1 tolerances Insulation ≥ 0.7 mm nominal; sheath ≥ 1.4 mm nominal
Sample test Hot set (thermal elongation) test — XLPE insulation GB/T 12706.1 §16.3.13 / GB/T 2951.11 200 ± 3 °C, 15 min, stress 0.2 MPa: elongation under load ≤ 175 %; permanent elongation after cooling ≤ 15 % Verifies degree of cross-linking
Sample test Conductor construction & diameter check GB/T 3956 Class 2; 7 × 1.70 mm; Ø ≈ 5.0 mm Sampled per batch
Type test Single-cable vertical flame-spread test (flame retardance) GB/T 18380.12 No flame spread; charring does not reach top reference point ZR / ZC flame-retardant property
Type test Bunched flame-spread test, class C GB/T 18380.35 Char extent ≤ 2.5 m above burner bottom edge; flame application 20 min; non-metallic volume ≥ 1.5 L/m Class ZC per GB/T 19666
Type test Bending test (mechanical) GB/T 12706.1 Bend around specified mandrel without insulation/sheath damage Mandrel diameter related to cable OD
Post-installation DC withstand test after installation Q/GDW 13244.1-2018 (recommended practice) 4U0 = 2.4 kV DC, 15 min, no breakdown For new installations; verify project specification
Optional Insulation resistance measurement at 20 °C Manufacturer test method ≥ 36.7 MΩ·km (typical finished-cable value) Not a routine item in GB/T 12706.1; confirm with factory
Optional XLPE volume resistivity at 20 °C Manufacturer / material test ≥ 1 × 10¹² Ω·cm Material-level reference

 

6. Usage Precautions

  1. Temperature limits — Never exceed 90 °C continuous or 250 °C short-circuit (≤ 5 s); derate ampacity for ambient temperature, bunching and installation method.
  2. Installation — Lay only at ambient ≥ 0 °C (preheat the cable if colder); keep the minimum bending radius of 20 × OD (single-core); avoid kinking, sharp edges and over-bending.
  3. Mechanical protection — Control pulling tension and side-wall pressure; for direct burial where mechanical damage, rodents or stones are a risk, use an armored type (e.g., YJV22) or protective ducting.
  4. Environment — Protect the PVC sheath from prolonged direct sunlight (UV degradation), strong solvents, oils and high ambient heat; for long-term outdoor exposure provide shading or use a UV-stable specification.
  5. Fire safety — ZR is a halogen-containing flame-retardant cable; smoke and corrosive gases are produced when burning. Where low smoke and zero halogen are mandatory (tunnels, occupied enclosed spaces), select WDZ-YJY (LSZH) instead.
  6. Termination & moisture — Fit terminations per manufacturer instructions and seal cable ends to prevent moisture ingress; after installation carry out the DC withstand test specified by the project (typically 4U0 / 15 min).
  7. Storage — Store drums upright in dry, ventilated areas, off the ground, protected from sunlight and heat sources.

7. Application Scope

  • AC 50 Hz power distribution at rated voltage 0.6/1 kV (max system voltage Um = 1.2 kV).
  • Buildings and residential/commercial complexes, industrial plants and workshops, municipal and infrastructure projects, power distribution rooms and substation LV circuits.
  • Installation in conduits, cable trays, ducts, cable trenches, tunnels and supported/suspended aerial runs.
  • Applications with flame-retardance requirements per local fire codes (indoor and semi-outdoor power circuits).

Note: figures marked "typical / approx." are compiled from manufacturer datasheets and standards cited above; the binding values are those of the factory test certificate and the project specification.