Cavo protetto a 5 core di rame 4x50mm2+1x25mm2 XLPE Retardante della fiamma 0,6/1kV
Copper Core 4+1 Cable ZR-YJV 4x50mm²+1x25mm² XLPE Flame Retardant 0.6/1kV Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame...
Cavo di alimentazione per cantiere ZR-YJV 4x35mm²+1x16mm² Rame ignifugo XLPE
Construction Site Power Cable ZR-YJV 4x35mm²+1x16mm² Flame Retardant Copper XLPE Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — ...
0.6/1kV XLPE Rame ZR-YJV 4x25mm²+1x16mm² Ritardante di Fiamma per Alimentazione
0.6/1kV XLPE Copper Cable ZR-YJV 4x25mm²+1x16mm² Flame Retardant for Power Supply Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — ...
Cavo di alimentazione in rame 4+1 Core 4*16mm² + 1*10mm² ZR-YJV XLPE Ritardante di Fiamma 0.6/1kV
4+1 Core 4*16mm² + 1*10mm² Copper Power Cable ZR-YJV XLPE Flame Retardant 0.6/1kV Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — ...
Cable di alimentazione principale del centro commerciale ZR-YJV 4x150mm2+1x70mm2 XLPE Retenente di fiamma in rame
Shopping Mall Main Power Cable ZR-YJV 4x150mm²+1x70mm² XLPE Copper Flame Retardant Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — ...
Cavo Rinforzato 4+1 Nuclei ZR-YJV 4x120mm²+1x70mm² XLPE Rame Ritardante di Fiamma
Heavy Duty 4+1 Core Cable ZR-YJV 4x120mm²+1x70mm² XLPE Copper Flame Retardant Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame...
Cavo principale per edifici alti ZR-YJV 4x95mm²+1x50mm² XLPE Rame Ritardante di Fiamma
High Rise Building Main Cable ZR-YJV 4x95mm²+1x50mm² XLPE Copper Flame Retardant Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — ...
Cavo XLPE ignifugo 4+1 Core 4×185mm2+1*95mm2 ZR-YJV rame 0,6/1kV
Flame Retardant XLPE Cable 4+1 Core 4×185mm²+1*95mm² ZR-YJV Copper 0.6/1kV Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame...
0.6/1kV ZC-YJV 5x16mm2 rame XLPE PVC cavo di alimentazione ignifuge per la distribuzione principale residenziale
0.6/1kV ZC-YJV 5x16mm² Copper XLPE PVC Flame-Retardant Power Cable for Residential Main Distribution Technical Datasheet — ZC-YJV 0.6/1 kV 5×16 mm² 1. Cable Designation & Meaning Code Meaning ZC Flame retardant, Class C (bundled combustion test per GB/T 18380.3 / GB/T 19666) YJ XLPE (cross...