logo
Anhui Tongdu International Trade Co., Ltd.
Online Service

Online Service

Contact Person
+86 19056002718
WeChat QR Code
Follow Us
No Products Found Matching Your Search Criteria:

"stranded copper cable xlpe insulation"

Please try a different search term or browse our product categories.

Recommend Other Products
Quality 4.0mm2 Solid Copper Conductor 450V 750V Single Stranded Copper Wire factory

4.0mm2 Solid Copper Conductor 450V 750V Single Stranded Copper Wire

BV 4.0mm² Solid Copper PVC Insulated Building Wire 450/750V Easy Pull Electrical Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 4.0 mm² Nominal cross-sectional area of conductor Construction: Plain copper conductor ...

Quality 2.5mm2 Solid Copper Conductor Ground Earth Solid Thhn Flame Retardant factory

2.5mm2 Solid Copper Conductor Ground Earth Solid Thhn Flame Retardant

Yellow Green BV 2.5mm² Ground Earth Wire PVC Insulated Copper Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain copper conductor (solid or stranded)...

Quality Aluminum Concentric Neutral Mv Cable 3x95mm2 3 Core Aluminium Armoured Cable factory

Aluminum Concentric Neutral Mv Cable 3x95mm2 3 Core Aluminium Armoured Cable

Main Distribution Aluminum Cable YJLV22 3x95mm² 8.7/15kV Armored MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor​ (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...

Quality Transport Hub Main Power Cable YJV22 3x240mm² 8.7/15kV Armored MV XLPE factory

Transport Hub Main Power Cable YJV22 3x240mm² 8.7/15kV Armored MV XLPE

Transport Hub Main Power Cable YJV22 3x240mm² 8.7/15kV Armored MV XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...

Quality Ultra Heavy MV Cable YJV22 3x185mm² 8.7/15kV Armored XLPE Power Cable factory

Ultra Heavy MV Cable YJV22 3x185mm² 8.7/15kV Armored XLPE Power Cable

Ultra Heavy MV Cable YJV22 3x185mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...

Quality Mega Industrial Main Cable YJV22 3x120mm² 8.7/15kV Armored MV XLPE factory

Mega Industrial Main Cable YJV22 3x120mm² 8.7/15kV Armored MV XLPE

Mega Industrial Main Cable YJV22 3x120mm² 8.7/15kV Armored MV XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV; U...

Quality 3 Core Armored MV Cable YJV22 3x50mm² 8.7/10kV 8.7/15kV XLPE Power Cable factory

3 Core Armored MV Cable YJV22 3x50mm² 8.7/10kV 8.7/15kV XLPE Power Cable

3 Core Armored MV Cable YJV22 3x50mm² 8.7/10kV 8.7/15kV XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...

Quality 4x70mm2+1x50mm2 Fire Resistant Cable 1KV 1.2KV Bare Copper Mineral Insulated Cable factory

4x70mm2+1x50mm2 Fire Resistant Cable 1KV 1.2KV Bare Copper Mineral Insulated Cable

Heavy Duty Fire Cable BTTRZ 4x70mm²+1x50mm² Mineral Insulated 0.6/1kV Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV Rated ...