"mineral fire resistant cable"
- 47 Items Found
BTTRZ 0.6/1kV 4x50mm²+1x25mm² Fire-resistant Cable for Industrial Emergency Feeders
BTTRZ 0.6/1kV 4x50mm²+1x25mm² Fire-resistant Cable for Industrial Emergency Feeders Cable Designation & Meaning Code Meaning B Fixed wiring T Copper conductor T Copper sheath R Flexible Z Heavy duty 4×50 mm² Four cores of 50 mm² copper conductor (phases) +1×25 mm² One core of 25 mm² copper conductor ...
BVVB Flat Sheathed Wires 300V 500V Space Saving Mineral Insulated Copper Cable
BVVB 2x2.5mm² Flat Twin Copper Sheathed Wire 300/500V Space Saving Household Cable Cable Designation & Meaning Code Meaning B Fixed wiring (Class B, fixed installation) V PVC insulation V PVC sheath B Flat profile (twin parallel) 2×2.5 mm² Two cores, each 2.5 mm² copper Construction : Two parallel ...
Hospital Critical Fire Proof Cable BTTRZ 4x35mm²+1x16mm² Mineral Mi Heating Cable
Hospital Critical Fire Proof Cable BTTRZ 4x35mm²+1x16mm² Mineral Mi Heating Cable Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...
BTTRZ Flame Retardant Cable 4x150mm2+1x70mm2 Mineral Insulated Cable
Ultra Fire Cable BTTRZ 4x150mm²+1x70mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ Flexible mineral-insulated copper-sheathed fire-resistant cable 4×150 mm² Four cores of 150 mm² copper conductor (3 phase + 1 neutral) +1×70 mm² One core of 70 mm² copper ...
BTLY Fire Rated Cable 4x35mm2 + 1x16mm2 Aluminum Sheath Cable For Emergency
NG-A BTLY 4x35+1x16mm2 Mineral Insulated Fire Resistant Aluminum Sheath Cable for Emergency Cable Designation & Meaning Code Meaning NG-A New Generation A-class fire-resistant (Chinese designation) (BTLY) Building wire, Thin copper conductor, Lightweight Y— alternative naming convention indicating: ...
Low Voltage 2 Cores Cable 2 X 10mm2 Stranded Copper Fire Resistant PVC Insulated Sheathed
Low Voltage Power Cable 0.6/1kv YJV-2*10mm² Stranded Copper XLPE Insulation Fire-Resistant PVC Outer Sheath Cable Designation & Meaning Code Meaning ZC Flame retardant C — IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 2×10 mm² Two cores, 10 mm² copper ...
3x400mm2 Medium Voltage Power Cable Aluminum XLPE Armored Mv Cable 8.7kV
YJLV22 3x400mm² Aluminum XLPE Armored MV Cable 8.7/15kV Cost Effective Underground Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Lü = aluminium) V PVC outer sheath 22 Steel tape armoured (double steel tape) 3×400 mm² Three cores, each ...
YJV22 Medium Voltage Power Cable 3x150mm2 Copper Mv Armoured Cable 15kV
YJV22 3x150mm² Copper XLPE Armored MV Cable 8.7/15kV Reliable Underground Power Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath 22 Steel tape armoured (double steel tape) 3×150 mm² Three cores, each 150 mm² copper Construction : Copper ...
YJLV22 3x150mm2 Copper HV High Voltage Power Cable XLPE Armored 26 35kV Underground
YJLV22 3x150mm² Copper XLPE Armored HV Cable 26/35kV High Voltage Underground Cable Designation & Meaning Code Meaning 26/35 kV Rated voltage: U₀ = 26 kV (phase-to-earth), U = 35 kV (phase-to-phase) YJ XLPE (cross-linked polyethylene) insulation L Aluminium Conductor V PVC outer sheath 22 Steel tape ...