BTTRZ 0.6/1kV 4x50mm²+1x25mm² Fire-resistant Cable for Industrial Emergency Feeders
Trading Properties
Product Summary
Product Details
bttrz fire resistant cable
,bttrz fire substation cable
,1kv fire resistant cable
Product Description
BTTRZ 0.6/1kV 4x50mm²+1x25mm² Fire-resistant Cable for Industrial Emergency Feeders
Cable Designation & Meaning
|
Code |
Meaning |
|---|---|
|
B |
Fixed wiring |
|
T |
Copper conductor |
|
T |
Copper sheath |
|
R |
Flexible |
|
Z |
Heavy duty |
|
4×50 mm² |
Four cores of 50 mm² copper conductor (phases) |
|
+1×25 mm² |
One core of 25 mm² copper conductor (neutral/earth) |
Construction: Four 50 mm² flexible copper conductors + one 25 mm² flexible copper conductor, each individually insulated with high-purity MgO mineral powder, enclosed in a seamless copper sheath (corrugated or smooth), with overall PVC outer sheath (optional, for identification/UV protection).
Applicable Standards
- GB/T 13033.1-2007 / IEC 60702-1 — Mineral insulated cables and their terminations — Part 1: Cables
- GB/T 13033.2-2007 / IEC 60702-2 — Mineral insulated cables and their terminations — Part 2: Terminations
- GB/T 3956-2008 / IEC 60228 — Conductors of insulated cables (Class 5 flexible)
- GB/T 19216.21 / IEC 60331-21 — Tests for electric cables under fire conditions — Circuit integrity
- GB/T 17651.2 / IEC 61034-2 — Measurement of smoke density
- GB/T 18380.3 / IEC 60332-3 — Flame retardant (Category A)

BTTRZ 4×50+1×25 mm² — Flexible Mineral-Insulated Fire-Resistant Power Cable — Specification
1. Overview & Ratings. BTTRZ 4×50+1×25 is a flexible fire-resistant power cable rated 0.6/1 kV, 90 °C normal working: four 50 mm² plus one 25 mm² copper core, each wrapped in mica-tape fire-resisting insulation, cabled inside a copper tape interlock armor and a PVC/LSZH outer sheath. OD ≈ 38 mm, ≈ 6500 kg/km (est.), ≈ 175 A (50 core) / ≈ 100 A (25 core) free air at 30 °C (est.). Its defining feature is 950 °C circuit integrity — it keeps life-safety circuits live during fire. Scope: fire pumps, emergency lighting, fire alarm and smoke-control circuits — not ordinary branch distribution.
2. Construction Stack (Inner → Outer, expanded).
| Layer / Feature | Build | Function |
|---|---|---|
| Conductors 4×50 + 1×25 | Compacted Cu, class 2 stranding | R ≤0.387 (50) / ≤0.741 (25) Ω/km |
| Mica-tape insulation | Wrapped ≈0.5 mm over each core | 950 °C fire circuit-integrity barrier |
| Core cabling | 4 power + 1 earth cabled | Compact round fire-rated core |
| Copper tape interlock | Armor ring | Mechanical protection + protective earth |
| PVC/LSZH outer sheath | ≈2.5 mm flame-retardant | Environmental jacket; LSZH low-smoke option |
| Fire-rated end seal | Gland/end seal at terminations | Preserves integrity at ends |
3. Electrical Characteristics. R ≤0.387 Ω/km (50) and ≤0.741 Ω/km (25) @20 °C. Test 3.5 kV AC / 5 min; ≈175 A / ≈100 A (est., air 30 °C); short-circuit ≈12 kA/1s (est.); 0.6/1 kV; 50/60 Hz.
Insulation & Sheath Data
|
Property |
Value |
|---|---|
|
Insulation material |
High-purity MgO mineral powder (≥ 99.5%) |
|
Inner sheath material |
Seamless copper tube (corrugated/smooth) |
|
Outer sheath material |
PVC or LSZH (optional) |
|
Long-term service temp. |
70 °C (continuous) / 105 °C (short-term) |
|
Max. conductor temp. (normal) |
70 °C |
|
Short-circuit temp. (≤5 s) |
250 °C (copper sheath limits) |
|
Emergency overload temp. |
150 °C (≤1 h) |
|
Test voltage AC (5 min) |
3.5 kV |
|
Dielectric strength |
≥ 20 kV/mm |
|
Volume resistivity @20 °C |
≥ 1×10¹⁰ Ω·cm |
|
Shield |
Copper sheath provides EMI/RFI shielding |
Electrical Parameters
|
Parameter |
Value |
Note |
|---|---|---|
|
Rated voltage U₀/U |
0.6 / 1 kV |
GB/T 13033 / IEC 60702 |
|
Max. system voltage |
1.2 kV AC / 1.5 kV DC |
— |
|
Test voltage AC (5 min) |
3.5 kV |
Routine test |
|
DC resistance @20 °C (phase) |
≤ 0.387 Ω/km per core |
GB/T 3956 Class 5 Cu max (50 mm²) |
|
DC resistance @20 °C (N/PE) |
≤ 0.727 Ω/km per core |
GB/T 3956 Class 5 Cu max (25 mm²) |
|
AC resistance @70 °C (phase, est.) |
≈ 0.48 Ω/km per core |
— |
|
AC resistance @70 °C (N/PE, est.) |
≈ 0.90 Ω/km per core |
— |
|
Current rating in air (30 °C) |
Three-phase AC: 165 A (per phase core) |
4×50+1×25, touching, in free air |
|
Current rating in tray (30 °C) |
Three-phase AC: 185 A (per phase core) |
4×50+1×25, spaced |
|
Current rating in conduit (30 °C) |
Three-phase AC: 140 A (per phase core) |
— |
|
Single-phase current capacity |
Single-phase AC: 165 A (L+N, with 1 core as PE spare) |
— |
|
DC current capacity |
165 A per core |
— |
|
Short-circuit current (1 s, Cu, 250 °C) |
≈ 5,500 A per phase core |
— |
|
Short-circuit current (1 s, Cu, 250 °C, N/PE) |
≈ 2,750 A per core |
— |
|
Capacitance (core-to-sheath, approx.) |
≈ 0.20 µF/km |
MgO |
|
Inductive reactance (approx.) |
≈ 0.07 Ω/km |
at 50 Hz |
|
Frequency |
50/60 Hz AC |
— |
Reference values: BTTRZ 4×50+1×25 at 165 A three-phase, 400 V → max load ≈ 114 kW (cos φ = 1.0). As single-phase at 165 A, 230 V → max load ≈ 38 kW (cos φ = 1.0). Suitable for fire-rated power distribution in high-rise buildings, emergency systems, evacuation routes, and critical infrastructure.
4. Thermal Response & Fire Behaviour. Mica insulation sustains a 90 °C continuous conductor temperature, with short-circuit capability up to 250 °C for ≤ 5 s. The cable is rated for service ambients between −15 and +70 °C. The defining property is fire resistance: under GB/T 19216.21 / IEC 60331-21, the cable maintains circuit integrity at rated voltage for at least 90 minutes when directly exposed to a 950 °C open flame. The corrugated copper sheath provides both a fire barrier and a mechanical shield against flame penetration. The LSZH outer jacket emits low smoke and no acid gas (halogen-free), meeting the requirements for tunnels, metro systems, hospitals and high-rise public buildings.
Temperature Characteristics
|
Property |
Value |
|---|---|
|
Max. conductor operating temp. |
70 °C (continuous) |
|
Max. short-circuit temp. (≤5 s) |
250 °C |
|
Emergency overload temp. |
150 °C (≤1 h) |
|
Min. installation ambient temp. |
−15 °C |
|
Service ambient range |
−15 °C to +70 °C |
|
Flexing temp. range |
−5 °C to +70 °C |
Fire Performance (BTTRZ — Mineral Insulated, Fire-Resistant)
|
Property |
Value / Requirement |
|---|---|
|
Fire resistance (circuit integrity) |
GB/T 19216.21 / IEC 60331-21 (950 °C, 180 min, circuit survives) |
|
Flame retardant |
GB/T 18380.3 / IEC 60332-3 Category A (non-combustible) |
|
Halogen content |
Zero halogen (MgO + Cu) |
|
Smoke density |
Zero smoke (GB/T 17651.2 / IEC 61034-2) |
|
Corrosivity |
Non-corrosive (Cu sheath) |
|
Toxicity |
Non-toxic (no fumes) |
|
EMI shielding |
Excellent (seamless copper sheath) |
|
Water resistance |
Excellent (sealed copper sheath) |
5. Installation Practice & Handling. Bends must not fall below 15 times the actual outer diameter — about 660 mm for this size. The corrugated copper sheath must be earthed at both ends to provide protective-earth continuity. Special sealing glands and termination kits are required at both ends to keep moisture out of the hygroscopic mica layer — improperly terminated ends are the most common failure point on mineral-insulated cables. Reels held below 0 °C in storage must be warmed indoors before uncoiling. The 175 A reference requires derating whenever ambient temperature, grouping or burial depth deviates from reference conditions. Because the cable weighs about 300 kg per 100 m, drum jacks and rated pulling gear must be used.
Mechanical & Installation Parameters
|
Parameter |
Value |
Remarks |
|---|---|---|
|
Minimum bending radius |
≥ 6 × OD → ≈ 180 mm at Ø30.0 mm |
flexible cable |
|
Max. pulling tension |
750 N per phase core (50 mm² × 15 N/mm²) |
Cu conductor limit |
|
Direct burial |
Suitable (with outer PVC/LSZH sheath) |
— |
|
Surface mounting |
Cable tray, conduit, trunking, direct fix |
— |
|
Conduit ID |
≥ 80 mm |
— |
|
Fixing |
heavy-duty cable ties, clamps, brackets |
— |
|
Impact resistance |
High (copper sheath) |
— |
|
Water resistance |
Excellent (sealed construction) |
— |
|
UV resistance |
Good (copper sheath, optional outer sheath) |
— |
|
Flex life |
Good (Class 5 fine-stranded) |
flexible |
|
Termination note |
Special mineral-insulated cable glands/terminations required (e.g., CG series) |
— |
6. Typical Service Applications. This 4×50+1×25 BTTRZ cable is the fire-rated feeder for life-safety and emergency power systems: emergency lighting and escape-route supply feeders, fire-alarm system main power and control loops, smoke-exhaust and pressurisation fan feeds, fire-pump and sprinkler-pump power circuits, emergency elevator and refuge-floor power feeds, hospital operating-theatre and ICU emergency supply, metro and tunnel emergency power circuits, high-rise building main fire-fighting risers, data-centre backup power and UPS feeders, oil and gas platform and refinery fire-resistant circuits, tunnel and underground-railway power and control cables, industrial oven and furnace auxiliary power where fire risk is high, stadium and large-venue emergency distribution, nuclear power plant auxiliary circuits, and any circuit where continued operation during a 90-minute fire event is mandated by building code. Approved installation methods include cable tray, direct tray in fire-protected zones, and conduit in fire-rated walls.

7. Testing & Quality Assurance Regime. Routine tests on every length include conductor DC resistance verification (50 mm² ≤ 0.387; 25 mm² ≤ 0.741 Ω/km) at 20 °C, the 3.5 kV AC / 5 min withstand, insulation resistance ≥ 36.7 MΩ·km, conductor continuity across all five cores, corrugated copper sheath electrical continuity, and dimensional inspection covering mica ≈ 0.8 mm, Cu sheath 0.3–0.5 mm, LSZH jacket ≥ 1.8 mm and overall diameter ≈ 44 mm. Sample and type tests comprise the 950 °C / 90 min fire-resistance test (GB/T 19216.21), vertical flame spread GB/T 18380.34 class A, smoke density GB/T 17651, halogen acid gas content GB/T 17650, sheath moisture-tightness / water-immersion leak test, bending at ≥ 15 × OD, short-circuit to 250 °C, and voltage re-test after fire exposure. A factory test certificate accompanies each drum.
Cable Parameters
| BTTRZ 4×50 + 1×25 mm² — Full Parameter Sheet | ||||
| Flexible mineral-insulated fire-resistant cable · 0.6/1 kV · Cu conductor / mica-tape insulation / corrugated Cu sheath / LSZH outer jacket · per GB/T 19216 (IEC 60331) · 4 large + 1 small core · finished Ø ≈ 44 mm · ≈ 3000 kg/km | ||||
| Section | Parameter | Value | Unit | Remarks / Standard |
| 01 · Identification | ||||
| Cable type | BTTRZ | — | Flexible mineral-insulated fire-resistant cable (Cu sheath, LSZH outer) | |
| Rated voltage (U0/U) | 0.6/1 | kV | AC 50 Hz; maximum system voltage Um = 1.2 kV | |
| Number of cores | 4 × 50 + 1 × 25 | — | 4 phase/line cores (50 mm²) + 1 neutral/earth core (25 mm²) | |
| Conductor material | Tinned annealed copper | — | Class 5 flexible stranded per GB/T 3956 | |
| Insulation material | Mica tape (muscovite/phlogopite) + glass-fibre reinforcement | — | Fire-rated, 950 °C continuous | |
| Inner filler | Fire-resistant glass-fibre rope | — | Hygroscopic / flame-retardant filler | |
| Metal sheath | Corrugated (spiralled) copper tube | — | Continuous fire, moisture and mechanical barrier | |
| Outer jacket | Low-smoke zero-halogen (LSZH) polyolefin | — | Flame-retardant, halogen-free | |
| Standard reference | GB/T 19216 / IEC 60331; GB/T 19666; GB/T 12706.1 | — | Fire-resistant power cable 0.6/1 kV | |
| 02 · Conductor | ||||
| Stranding — 50 mm² (×4) | 133 × 0.30 mm | — | Class 5 tinned copper, flexible lay-up | |
| Conductor diameter — 50 mm² | ≈ 8.6 | mm | Strand-lay diameter (est.) | |
| DC resistance — 50 mm² @ 20 °C | ≤ 0.387 | Ω/km | Maximum per GB/T 3956 Class 5 | |
| Stranding — 25 mm² (×1) | 50 × 0.25 mm | — | Class 5 tinned copper, neutral/earth | |
| Conductor diameter — 25 mm² | ≈ 5.6 | mm | Strand-lay diameter (est.) | |
| DC resistance — 25 mm² @ 20 °C | ≤ 0.741 | Ω/km | Maximum per GB/T 3956 Class 5 | |
| Conductor flexibility | Class 5 (flexible) | — | Bendable on-site, unlike rigid MI cable | |
| 03 · Insulation | ||||
| Insulation type | Mica tape (muscovite / phlogopite) | — | Wrapped with overlapping tape layers | |
| Insulation thickness per core | ≈ 0.8 | mm | Multiple mica-tape overlaps | |
| Core Ø — 50 mm² (over insulation) | ≈ 10.2 | mm | 8.6 + 2 × 0.8 | |
| Core Ø — 25 mm² (over insulation) | ≈ 7.2 | mm | 5.6 + 2 × 0.8 | |
| Fire resistance rating | 950 °C / 90 min | — | Per GB/T 19216.21 / IEC 60331-21 | |
| Insulation colour coding | Phase cores: black/brown/grey/black; neutral: light blue; earth: green-yellow | — | Per GB/T 6995 | |
| 04 · Assembly & Filler | ||||
| Core arrangement | 4 large cores + 1 small neutral cabled round | — | 5-core round lay-up | |
| Filler material | Fire-resistant glass-fibre rope | — | Fills interstices, keeps round shape | |
| Binder tape | Glass-fibre tape | — | Holds bundle before sheath | |
| Assembled bundle Ø | ≈ 38 | mm | Before copper sheath (est.) | |
| Lay-up direction | Right-hand (S) | — | Standard convention | |
| 05 · Corrugated Copper Sheath | ||||
| Sheath material | Copper strip, continuously corrugated | — | Longitudinally welded / spiral-formed | |
| Sheath thickness | 0.3 – 0.5 | mm | Electrical continuity and earth path | |
| Corrugation pitch | ≈ 15 | mm | Allows flexibility and bending | |
| Sheath function | Fire barrier + moisture barrier + earth conductor | — | May serve as protective earth (PE) | |
| Sheath diameter | ≈ 40 | mm | Over bundle (est.) | |
| 06 · Outer Jacket | ||||
| Jacket material | LSZH (low-smoke zero-halogen) polyolefin | — | Flame-retardant, halogen-free | |
| Jacket thickness | 1.8 | mm | Mechanical protection, UV-resistance | |
| Overall finished diameter | ≈ 44 | mm | Cross-referenced industry sample | |
| Approximate cable mass | ≈ 3000 | kg/km | Cu + mica + LSZH build-up | |
| Jacket colour | Orange / red (standard fire-cable colour) | — | For identification; custom available | |
| Mass per 100 m | ≈ 300 | kg/100 m | For drum loading | |
| 07 · Electrical | ||||
| Rated voltage U0/U | 0.6/1 | kV | AC 50 Hz | |
| Maximum system voltage Um | 1.2 | kV | — | |
| DC resistance — 50 mm² @ 20 °C | ≤ 0.387 | Ω/km | GB/T 3956 Class 5 | |
| DC resistance — 25 mm² @ 20 °C | ≤ 0.741 | Ω/km | GB/T 3956 Class 5 | |
| AC impedance @ 50 Hz — 50 mm² | ≈ 0.387 | Ω/km | R-dominant | |
| Insulation resistance | ≥ 36.7 | MΩ·km | Mica-rated, very high | |
| Capacitance (typical) | ≈ 0.45 | μF/km | Per phase (est.) | |
| Routine test voltage | 3.5 kV AC / 5 min | — | Power-frequency withstand | |
| Air ampacity @ 25 °C | ≈ 175 | A | 4 cores loaded, Cu (est.) | |
| 08 · Thermal & Fire | ||||
| Max continuous conductor temp. | 90 | °C | Normal service | |
| Short-circuit temp. (≤ 5 s) | 250 | °C | Copper limit | |
| Fire-resistance rating | 950 °C / 90 min | — | GB/T 19216.21 / IEC 60331-21 | |
| Circuit integrity under fire | Maintained | — | With rated voltage during flame exposure | |
| Flame behaviour | Non-flame-spreading | — | GB/T 18380.34 class A | |
| Smitch emission | Low smoke | — | LSZH jacket | |
| Halogen content | Halogen-free | — | LSZH outer jacket | |
| Service ambient range | −15 to +70 | °C | For fixed installation | |
| 09 · Installation | ||||
| Min bending radius | ≥ 15 × OD ≈ 660 | mm | Fixed installation | |
| Sheath as earth (PE) | Allowed | — | Copper sheath provides protective earth | |
| Termination | Special gland and sealing termination | — | Prevents moisture ingress into mica layer | |
| Laying methods | Cable tray, trench, duct, direct burial (with armour if required) | — | Indoor / outdoor / underground | |
| Outdoor / burial note | Suitable | — | LSZH jacket is UV-resistant when correctly sheathed | |
| Special termination kits | Required at both ends | — | Sealing + earth bonding kit | |
| 10 · Packing | ||||
| Standard supply length | 500 or 1000 | m/drum | Custom cut lengths available | |
| Reel / packing type | Wooden-steel drum | — | Heavy-weight drum | |
| Surface marking | BTTRZ, 0.6/1 kV, size, supplier, year, metre marks | — | Per GB/T 6995 | |
| Storage conditions | Dry, covered, −15 to +40 °C | — | Sealed ends to prevent moisture | |
| Transport | Drums secured against rolling | — | Do not drag; heavy cable | |
Cable Test Parameters
| Test Parameters — BTTRZ 4×50+1×25 mm² | ||||
| No. | Test Item | Test Condition / Method | Requirement | Type |
| 1 | Conductor DC resistance | GB/T 3048.4, 20 °C | 50 mm² ≤ 0.387; 25 mm² ≤ 0.741 Ω/km | Routine |
| 2 | Power-frequency withstand | 3.5 kV AC, 5 min | No breakdown | Routine |
| 3 | Insulation resistance | GB/T 3048.5 | ≥ 36.7 MΩ·km | Routine |
| 4 | Conductor continuity | Visual + electrical | All 5 cores continuous | Routine |
| 5 | Dimensional check | Micrometer | OD ≈ 44 mm; jacket ≥ 1.8 mm | Routine |
| 6 | Fire-resistance test | GB/T 19216.21, 950 °C, 90 min | Circuit integrity maintained, no breakdown | Type |
| 7 | Flame spread test | GB/T 18380.34 class A | No vertical flame spread beyond specified char | Type |
| 8 | Smoke density | GB/T 17651 | Low smoke output | Type |
| 9 | Halogen acid gas content | GB/T 17650 | Halogen-free (LSZH jacket) | Type |
| 10 | Corrugated copper sheath continuity | Continuity meter | Electrically continuous along cable | Routine |
| 11 | Sheath tightness / moisture test | Water immersion / leak test | No water ingress | Type |
| 12 | Bending test | ≥ 15 × OD mandrel | No damage to sheath or insulation | Type |
| 13 | Short-circuit test | 250 °C, 5 s equivalent | No insulation collapse | Type |
| 14 | Voltage test after fire | After 950 °C/90 min fire | Withstands 3.5 kV AC | Type |
| 15 | Marking legibility | Visual + rubbing | BTTRZ / size / voltage / metre marks legible | Routine |
| 16 | Core identification | Visual + continuity | Correct colour-coded conductors identified | Routine |
Cable Cross Section Structure

| BTTRZ 4×50+1×25 mm² — Cross-Section Construction Diagram (Schematic) | |||||
| Layered fire-resistant build-up: tinned Cu conductor → mica-tape insulation → glass-fibre filler → corrugated Cu sheath → LSZH jacket · 0.6/1 kV · GB/T 19216 950 °C/90 min · finished Ø ≈ 44 mm | |||||
| No. | Layer | Material / Construction | Nominal Thickness (mm) | Diameter (mm) | Function / Remarks |
| 1 | Conductor (Cu) | Tinned annealed copper, Class 5 flexible — 133×0.30 mm for 50 mm² (×4), 50×0.25 mm for 25 mm² (×1) | — | ≈ 8.6 / ≈ 5.6 | Power conductors; R ≤ 0.387 (50) / 0.741 (25) Ω/km at 20 °C |
| 2 | Mica-tape insulation | Muscovite/phlogopite mica tape, overlapping wrap, glass-fibre reinforced | ≈ 0.8 | ≈ 10.2 / ≈ 7.2 | Fire-rated dielectric; survives 950 °C / 90 min flame exposure |
| 3 | Inner filler & binder | Fire-resistant glass-fibre rope fills interstices; glass-fibre binder tape | — | ≈ 38 (bundle) | Keeps round shape, adds thermal insulation, non-hygroscopic |
| 4 | Corrugated Cu sheath | Continuously corrugated (spiralled) copper tube, longitudinal welded | 0.3 – 0.5 | ≈ 40 | Fire + moisture barrier; may serve as protective earth (PE) |
| 5 | LSZH outer jacket | Low-smoke zero-halogen polyolefin, flame-retardant, orange/red | 1.8 | ≈ 44 (finished) | Mechanical + UV protection; halogen-free for public areas |
| Key Dimensions & Properties (expanded) | |||||
| Finished cable diameter | ≈ 44 | mm | Cross-referenced industry sample | ||
| Approximate cable mass | ≈ 3000 | kg/km | Cu + mica + LSZH build-up | ||
| Nominal voltage rating | 0.6/1 | kV | AC 50 Hz; Um = 1.2 kV | ||
| Max continuous conductor temp. | 90 | °C | Normal service | ||
| Short-circuit temp. (≤5 s) | 250 | °C | Copper limit | ||
| Fire-resistance rating | 950 °C / 90 min | — | GB/T 19216.21 / IEC 60331-21 | ||
| Min bending radius | ≥ 15 × OD ≈ 660 | mm | Fixed installation | ||
| DC resistance — 50 mm² | ≤ 0.387 | Ω/km | At 20 °C | ||
| DC resistance — 25 mm² | ≤ 0.741 | Ω/km | At 20 °C | ||
| Insulation resistance | ≥ 36.7 | MΩ·km | Mica-rated | ||
| Routine test voltage | 3.5 kV AC / 5 min | — | Power-frequency withstand | ||
| Air ampacity @ 25 °C | ≈ 175 | A | 4 cores loaded, Cu (est.) | ||
| Corrugated Cu sheath thickness | 0.3 – 0.5 | mm | Fire/moisture barrier + PE | ||
| Outer jacket thickness | 1.8 | mm | LSZH, halogen-free | ||
| Mass per 100 m | ≈ 300 | kg/100 m | For drum loading | ||
| Schematic — not to exact scale. Finished Ø ≈ 44 mm and weight ≈ 3000 kg/km from cross-referenced industry samples; conductor/insulation diameters per GB/T 3956 and GB/T 12706.1; ampacity 175 A is an engineering estimate. Values marked (est.) require confirmation against the factory test certificate. | |||||
Cable Construction Description
| Construction Description — BTTRZ 4×50+1×25 mm² | |||
| Layer-by-layer build-up narrative · 0.6/1 kV fire-resistant power cable · GB/T 19216 950 °C/90 min · tinned Cu / mica / corrugated Cu / LSZH · finished Ø ≈ 44 mm | |||
| 1. Product Identity & Ratings | |||
| BTTRZ 4×50+1×25 is a flexible mineral-insulated fire-resistant power cable rated 0.6/1 kV (Um = 1.2 kV) at 50 Hz, built around four 50 mm² tinned-copper Class 5 flexible phase conductors and one 25 mm² neutral/earth conductor. Unlike rigid magnesium-oxide mineral-insulated cables, BTTRZ uses mica-tape wrapped insulation enclosed in a continuously corrugated copper tube, then jacketed in a low-smoke zero-halogen (LSZH) outer sheath. The cable is designed and type-tested to maintain circuit integrity for at least 90 minutes at 950 °C open-flame exposure (GB/T 19216.21 / IEC 60331-21). Finished diameter is about 44 mm and nominal mass about 3000 kg/km (≈ 300 kg per 100 m), supplied on 500 m or 1000 m wooden-steel drums. With four 50 mm² cores loaded, the cable carries about 175 A in free air at 25 °C (engineering estimate), making it the standard fire-rated feeder for emergency and safety-critical power circuits. | |||
| 2. Tinned Copper Conductors | |||
| Each 50 mm² phase conductor is stranded from 133 tinned annealed copper wires of 0.30 mm in Class 5 flexible lay-up, giving a strand-lay diameter of about 8.6 mm and a DC resistance ceiling of 0.387 Ω/km at 20 °C. The 25 mm² neutral/earth conductor uses 50 wires of 0.25 mm, diameter ≈ 5.6 mm, R ≤ 0.741 Ω/km. Tinning prevents copper oxidation under prolonged high-temperature exposure and improves solderability at terminations. | |||
| 3. Mica-Tape Insulation | |||
| Each conductor is wrapped with overlapping muscovite/phlogopite mica tape reinforced with glass-fibre, reaching about 0.8 mm total thickness. Mica is an inorganic mineral that does not burn and retains dielectric strength at temperatures up to 1000 °C — this is the layer that keeps the circuit alive during a fire. The insulation around each 50 mm² core measures about 10.2 mm over mica; the 25 mm² core about 7.2 mm. | |||
| 4. Filler, Corrugated Copper Sheath & LSZH Jacket | |||
| After mica wrapping, four 50 mm² cores and the 25 mm² core are cabled round, with fire-resistant glass-fibre rope filling interstices and a glass-fibre binder tape holding the bundle. A 0.3–0.5 mm corrugated (spiralled) copper tube is then formed continuously around the bundle — this sheath is the mechanical and moisture barrier, provides electrical continuity, and may be used as the protective earth (PE). A 1.8 mm LSZH (low-smoke zero-halogen) polyolefin jacket in standard orange/red is extruded over the copper sheath to the ≈ 44 mm finish, providing abrasion and UV resistance while emitting low smoke and no acid gas in fire. | |||
| 5. Site Handling & Operational Notes | |||
| • Observe the 15 × OD minimum bending radius (≈ 660 mm). • Use special sealing glands at both ends to keep moisture out of the mica layer. • The corrugated copper sheath must be earthed at both ends. • Service ambient −15 to +70 °C; conductor up to 90 °C continuous, 250 °C short-circuit. • Fire rating 950 °C / 90 min per GB/T 19216.21. • Termination kits must be ordered with the cable. • Heavy cable (≈ 300 kg/100 m) — use drum jacks and pulling gear rated for the load. |
8. Factory Advantages.
- Fire-rated circuit integrity — mica-tape 950 °C survival keeps life-safety circuits live when they matter.
- Copper interlock armor — mechanical crush/impact protection plus a built-in protective-earth path.
- Distinctive jacket — orange/red fire-rated identity makes life-safety circuits easy to find on site.
- LSZH option — low smoke, halogen-free release for evacuation and public routes.
- Tested survival data — fire-integrity type evidence supports code and tender submission.
- Routine electrical QA — every batch gets 3.5 kV withstand and resistance tests.
- Building-grade supply — metered for fire pumps, emergency lighting and alarm feeds.
- Length-on-drum — cut to the exact emergency-circuit run on heavy drums.
- Certified support pack — test record plus fire-rating data for life-safety sign-off.

9. Packaging, Storage & Logistics. Cut to measured fire-circuit length on heavy wooden drums with sealed ends; store dry indoor, shaded, avoid UV.

10. Procurement Specification. State "BTTRZ 4×50+1×25", length, LSZH vs PVC jacket, and the required fire-survival duration; request the type test certificate and routine records. Fire-rated glands/lugs must be used to preserve circuit integrity. Est. values and the 950 °C duration confirmed against the certificate.
11. Cable Industry FAQ.
- Q1: What does "BTTRZ" actually mean? B = fixed-installation wiring cable; T = copper conductor (tinned); T = mica-tape insulation; R = flexible (corrugated, not rigid magnesium-oxide); Z = fire-resistant (circuit integrity maintained under flame). It is the Chinese designation for a flexible mineral-insulated fire-resistant cable, equivalent to BTTW or YTTW in parallel naming systems.
- Q2: How is BTTRZ different from rigid BTTZ (magnesium oxide) cable? Rigid BTTZ uses magnesium-oxide powder packed around solid copper conductors inside a solid copper tube — it cannot bend on site. BTTRZ uses mica-tape insulation on flexible Class 5 stranded conductors inside a corrugated (spiralled) copper tube, so it bends on site like a normal cable and does not require special installation skills.
- Q3: What does "950 °C / 90 min" actually guarantee? During the GB/T 19216.21 / IEC 60331-21 test, the cable is laid in a test furnace, energised at rated voltage, and directly exposed to a 950 °C flame for 90 minutes. The cable must continue to carry the load without electrical breakdown. This is the rating that justifies its use on fire pumps, emergency lighting and escape-route circuits.
- Q4: Why is the corrugated copper sheath necessary? The copper sheath serves three purposes: (i) it is a physical barrier that prevents flame from reaching the mica layer; (ii) it is a moisture barrier — mica is hygroscopic and must stay dry; (iii) it provides a continuous electrical path that can double as the protective earth (PE), reducing the need for a separate earth conductor.
- Q5: Why is the jacket LSZH (low-smoke zero-halogen) instead of PVC? In a fire, PVC releases dense smoke and hydrochloric acid gas, which are the dominant causes of death in fires (inhalation, visibility loss, corrosion of equipment). LSZH jacket releases low smoke and no acid gas — essential in tunnels, metros, hospitals and high-rise public buildings where evacuation is slow and equipment must be protected.
- Q6: Why must the termination kit be special? Mica tape is hygroscopic: if moisture enters the cable end, the insulation resistance collapses and the cable fails. Standard PVC cable glands are not air- and moisture-tight. The BTTRZ termination kit uses a sealed brass gland with epoxy sealing compound and a heat-shrink boot, keeping the mica layer dry for the design life.
- Q7: Can the copper sheath replace the separate earth conductor? Yes — the corrugated copper sheath is electrically continuous and can be sized as the protective earth (PE), provided its cross-sectional area and fault-current capacity meet the installation code. Many BTTRZ 4+0 designs omit the separate earth core and rely on the sheath, reducing the cable size.
- Q8: Why is this cable so heavy (≈ 3000 kg/km)? Three reasons: 50 mm² copper is dense (5 × 4 × 8.89 g/cm³ ≈ 178 kg/km of copper); the corrugated copper sheath adds another ≈ 1500 kg/km of copper; and the LSZH jacket is compounded with mineral fillers. The result is a heavy cable that needs drum jacks and mechanical pulling.
- Q9: Can BTTRZ be used outdoors or buried directly? Yes — the LSZH jacket is UV-resistant and the copper sheath is an effective moisture barrier, so BTTRZ can be installed outdoors, in trays or directly in buried trenches. Unlike ordinary PVC cables, it does not degrade under fire-adjacent or moisture-exposed conditions.
- Q10: Which tests confirm acceptability on delivery and before energisation? At delivery, verify the factory fire-resistance certificate (950 °C / 90 min), conductor resistance (50 ≤ 0.387; 25 ≤ 0.741 Ω/km), dimensions (≈ 44 mm), and the drum end-seal integrity. After installation, complete an insulation-resistance test, a 3.5 kV AC / 5 min withstand, and verify both ends of the corrugated copper sheath are properly earthed before energising.
- Q11: What service life can be expected? When installed, terminated and operated within the stated temperature, voltage and fire ratings, BTTRZ cable is designed for a service life of around 30–40 years in fixed installation. The two failure modes to watch are moisture ingress through improperly sealed terminations (reduces insulation resistance) and mechanical damage to the corrugated sheath (loss of earth continuity). Both are prevented by correct installation and periodic inspection.