Hospital Critical Fire Proof Cable BTTRZ 4x35mm²+1x16mm² Mineral Mi Heating Cable

Hospital Critical Fire Proof Cable BTTRZ 4x35mm²+1x16mm² Mineral Mi Heating Cable

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
BTTRZ 4x35mm²+1x16mm²

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
10000 meters per month

Product Summary

Hospital Critical Fire Proof Cable BTTRZ 4x35mm²+1x16mm² Mineral Mi Heating Cable Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...

Product Details

Highlight:

critical fire proof cable

,

fire proof cable mineral

,

3200kg/km mi heating cable

Conductor (×4, power):
Bare Annealed Copper, Class 5 Fine-stranded Flexible, Typical 276×∅0.40 Mm (35 Mm²), Conductor Ø ≈ 7.3–8.4 Mm
Conductor (×1, PE):
Bare Annealed Copper, Class 5 Fine-stranded Flexible, Typical 126×∅0.40 Mm (16 Mm²), Conductor Ø ≈ 5.0–5.8 Mm
Conductor nominal area (power):
35 Mm²
Conductor nominal area (PE):
16 Mm²
Number of cores:
5 (4+1)
Conductor class:
Class 5 Flexible
Conductor construction (power):
276×∅0.40 Mm (typical)
Conductor construction (PE):
126×∅0.40 Mm (typical)
Conductor diameter (approx., power):
7.3–8.4 Mm
Conductor diameter (approx., PE):
5.0–5.8 Mm
Insulation (×5):
Fire-resistant Mica Tape + XLPE (or Ceramic Silicone Rubber); Colours: Brown/black/grey (L1/L2/L3), Blue (N), Green/yellow (PE)
Insulation thickness:
0.9 Mm (power Cores, 35 Mm²); 0.7 Mm (PE Core, 16 Mm²)
Diameter over insulated core (power):
9.1–10.2 Mm
Diameter over insulated core (PE):
6.4–7.2 Mm
Assembly:
Five Insulated Cores With Mineral Fire-resistant Fillers Twisted Together (round)
Inner bedding:
Mineral Fire-resistant Filler (MgO-based Or Mica Tape Wrap)
Metallic sheath:
Continuous Seam-welded Corrugated Copper Tube; Acts As Armour + Water Barrier + PE
Sheath wall thickness:
Copper Tube Wall ≈ 0.7–0.9 Mm (corrugated)
Outer covering:
None Required (copper Sheath Exposed); Optional PVC/LSZH Paint Coating For Corrosion Protection
Armour:
Copper Sheath Provides Equivalent Of Armour
Screen:
Copper Sheath Provides Electromagnetic Shielding
Overall cable diameter:
23 – 28 Mm
Design outer diameter:
≈ 25.4 Mm
Approx. weight:
2.8 – 3.6 Kg/m (2800–3600 Kg/km)
Design weight:
≈ 3200 Kg/km
Cable shape:
Round

Product Description

Hospital Critical Fire Proof Cable BTTRZ 4x35mm²+1x16mm² Mineral Mi Heating Cable

Cable Designation & Meaning

Code

Meaning

BTTRZ

B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated)

0.6/1 kV

Rated voltage U₀/U = 0.6/1 kV; Uₘ = 1.2 kV

4×35 mm² + 1×16 mm²

Four power cores 35 mm² + one protective earth core 16 mm² (5-core, 4+1 configuration)


Construction: Flexible mineral-insulated fire-resistant cable, corrugated copper tube sheath, round profile (5-core)


Note: BTTRZ employs Class 5 fine-stranded flexible copper conductors. Each core is insulated with fire-resistant mica tape plus XLPE (or ceramic silicone rubber). Cores are assembled with mineral fillers and enclosed in a continuously welded corrugated copper tube sheath, which serves simultaneously as armour, water barrier, and PE conductor. The 4+1 configuration is designed for TN-S three-phase five-wire systems; the PE conductor is 16 mm². Per GB/T 16895 / IEC 60364, for phase conductor 16 < S ≤ 35 mm², PE ≥ 16 mm². Since phase = 35 mm² (at the upper bound of 16–35 range), PE = 16 mm² is fully compliant.


Hospital Critical Fire Proof Cable BTTRZ 4x35mm²+1x16mm² Mineral Mi Heating Cable


Hospital Critical Fire Proof Cable BTTRZ 4x35mm²+1x16mm² Mineral Mi Heating CableBTTRZ 4×35 + 1×16 mm² — Cable Specification & Engineering Data


1. Product Overview & Rating Summary. BTTRZ 4×35+1×16 is a flexible mineral-insulated fire-resistant power cable rated 0.6/1 kV (Um = 1.2 kV) at 50 Hz, built around four 35 mm² tinned-copper Class 5 flexible phase conductors and one 16 mm² neutral/earth conductor. Unlike rigid magnesium-oxide mineral-insulated cables, BTTRZ uses mica-tape wrapped insulation enclosed in a continuously corrugated copper tube, then jacketed in a low-smoke zero-halogen (LSZH) outer sheath. The cable maintains circuit integrity for at least 90 minutes at 950 °C open-flame exposure (GB/T 19216.21 / IEC 60331-21). Finished diameter is about 30 mm and nominal mass about 1400 kg/km (≈ 140 kg per 100 m), supplied on 500 m or 1000 m wooden-steel drums. With four 35 mm² cores loaded, the cable carries about 140 A in free air at 25 °C (engineering estimate), making it the standard fire-rated feeder for fire pumps, main smoke-exhaust fans and emergency main distribution risers.


2. Layer-by-Layer Construction (Conductor to Outer Jacket).

Layer Construction Wall Diameter
Conductor (Cu) ×5 Tinned annealed Cu, Class 5 — 276×0.40 mm (35 mm², ×4) + 126×0.40 mm (16 mm², ×1) — ≈ 8.9 / ≈ 6.0 mm
Mica-tape insulation ×5 Muscovite/phlogopite mica tape, overlapping wrap, glass-fibre reinforced ≈ 0.7 mm ≈ 10.3 / ≈ 7.4 mm per core
Filler & binder Fire-resistant glass-fibre rope + glass-fibre binder tape — ≈ 25 mm bundle
Corrugated Cu sheath Continuously corrugated (spiralled) copper tube, longitudinal welded ≈ 0.3 mm ≈ 26 mm
LSZH outer jacket Low-smoke zero-halogen polyolefin, flame-retardant, orange/red 1.8 mm ≈ 30 mm (finished)


3. Electrical Characteristics. Each 35 mm² phase conductor is held to a maximum DC resistance of 0.524 Ω/km at 20 °C, rising to about 0.684 Ω/km at the 90 °C operating point. The 16 mm² neutral/earth conductor holds R ≤ 1.15 Ω/km at 20 °C. Every length survives the routine 3.5 kV AC power-frequency proof held for five minutes. Finished-cable insulation resistance remains above 36.7 MΩ·km (mica-rated, very high), and typical figures include per-core capacitance ≈ 0.45 μF/km and 50 Hz AC impedance ≈ 0.524 Ω/km. With four 35 mm² cores energised, reference loading is about 140 A in free air at 25 °C.

Insulation Data

Property

Value

Material

XLPE (cross-linked polyethylene) or ceramic silicone rubber over mica tape

Nominal thickness

0.9 mm (power), 0.7 mm (PE)

Long-term service temp.

90 °C (XLPE) / 125 °C (ceramic silicone)

Short-circuit temp. (≤5 s)

250 °C (XLPE), 350 °C (ceramic)

Emergency overload temp.

130 °C

Fire survival

950 °C / 180 min (GB/T 19216.21, IEC 60331)

Routine test voltage

3.5 kV AC / 5 min

Type-test voltage

6.5 kV AC

Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

Uₘ = 1.2 kV

Test voltage AC (5 min)

3.5 kV

Routine

Type-test voltage

6.5 kV

—

DC resistance @20 °C (power core)

≤ 0.524 Ω/km

GB/T 3956 Class 5 max, 35 mm²

DC resistance @20 °C (PE core)

≤ 1.15 Ω/km

GB/T 3956 Class 5 max, 16 mm²

AC resistance @90 °C (est., power)

≈ 0.669 Ω/km

per core

AC resistance @90 °C (est., PE)

≈ 1.47 Ω/km

per core

Current rating in air (single-phase, 30 °C)

≈ 120 – 145 A

per core

Current rating (design, per power core)

≈ 130 A

GB/T 16895 / manufacturer data

Current rating (3-phase+N+PE, balanced)

≈ 90 – 130 A per phase

derated due to bundling

Direct buried

Applicable (copper sheath waterproof)

—

Short-circuit current (1 s, Cu, 250 °C)

≈ 3.5 kA (3500 A)

35 mm²

Short-circuit current (1 s, Cu, 250 °C, PE)

≈ 1.6 kA (1600 A)

16 mm²

Frequency

50/60 Hz AC

—


Reference values: 35 mm² at 130 A, 3-phase 400 V → max balanced load ≈ 90.1 kW. Voltage drop at 130 A ≈ 3.2 V/km per core (≈0.8% per 100 m).

Temperature Characteristics

Property

Value

Max. conductor operating temp.

90 °C (continuous)

Max. short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C

Min. installation ambient temp.

−20 °C (flexible construction)

Service ambient range

−20 °C to +90 °C

Fire survival

950 °C / 180 min (circuit integrity maintained)


4. Thermal Response & Flame Behaviour. Mica insulation sustains a 90 °C continuous conductor temperature, with short-circuit capability up to 250 °C for ≤ 5 s. The cable is rated for service ambients between −15 and +70 °C. The defining property is fire resistance: under GB/T 19216.21 / IEC 60331-21, the cable maintains circuit integrity at rated voltage for at least 90 minutes when directly exposed to a 950 °C open flame. The corrugated copper sheath provides both a fire barrier and a mechanical shield against flame penetration. The LSZH outer jacket emits low smoke and no acid gas (halogen-free), meeting the requirements for tunnels, metro systems, hospitals and high-rise public buildings.

Fire Performance (BTTRZ — Mineral Insulated)

Property

Value / Requirement

Flame retardant

GB/T 18380.33 Category B (ZB available)

Halogen content

Zero halogen (IEC 60754-1)

Smoke density

Low smoke (IEC 61034, light transmittance >60%)

Corrosivity

Non-corrosive (IEC 60754-2)

Fire survival (circuit integrity)

950 °C / 180 min (IEC 60331)

Toxicity

Low toxicity (IEC 62821)


5. Installation Practice & Handling. Bends must not fall below 15 times the actual outer diameter — about 450 mm for this size. The corrugated copper sheath must be earthed at both ends to provide protective-earth continuity. Special sealing glands and termination kits are required at both ends to keep moisture out of the hygroscopic mica layer — improperly terminated ends are the most common failure point on mineral-insulated cables. Reels held below 0 °C in storage must be warmed indoors before uncoiling. The 140 A reference requires derating whenever ambient temperature, grouping or burial depth deviates from reference conditions. At about 140 kg per 100 m, the cable requires drum jacks and rated pulling gear.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 6 × OD → ≈ 152 mm at Ø25.4 mm

flexible installation

Max. pulling tension

2200 N

use proper grips on copper sheath

Direct burial

Suitable

copper sheath waterproof; add PVC paint for soil corrosion protection

Conduit ID

≥ 1.5 × OD → ≥ 38 mm; use 40 mm or 50 mm

—

Fixing

cable clamps, stainless steel ties (compatible with copper sheath)

—

Flexing

suitable for fixed installation with limited flexing during installation

not for continuous flexing

Impact resistance

High

corrugated copper tube absorbs mechanical shock

Water resistance

Excellent

continuous welded copper tube


6. Typical Service Applications. This 4×35+1×16 BTTRZ cable is the fire-rated feeder for medium-to-large emergency and safety-critical circuits: fire-pump and sprinkler-pump main feeds up to about 30 kW, main smoke-exhaust and pressurisation fan feeds up to about 11 kW, emergency lighting main risers, fire-alarm system power and control loops, emergency elevator power supply, hospital operating-theatre and ICU emergency main feeders, metro and tunnel emergency power distribution, high-rise building fire-fighting riser main branches, data-centre UPS emergency feeders, oil and gas platform fire-resistant power circuits, stadium and large-venue emergency distribution, industrial furnace and oven emergency control power, and any circuit where continued operation during a 90-minute fire event is mandated by building code. Approved installation methods include cable tray, direct tray in fire-protected zones, and conduit in fire-rated walls.


Hospital Critical Fire Proof Cable BTTRZ 4x35mm²+1x16mm² Mineral Mi Heating Cable


7. Testing & Quality Assurance Regime. Routine tests on every length include conductor DC resistance verification (35 mm² ≤ 0.524; 16 mm² ≤ 1.15 Ω/km) at 20 °C, the 3.5 kV AC / 5 min withstand, insulation resistance ≥ 36.7 MΩ·km, conductor continuity across all five cores, corrugated copper sheath electrical continuity, and dimensional inspection covering mica ≈ 0.7 mm, Cu sheath ≈ 0.3 mm, LSZH jacket ≥ 1.8 mm and overall diameter ≈ 30 mm. Sample and type tests comprise the 950 °C / 90 min fire-resistance test (GB/T 19216.21), vertical flame spread GB/T 18380.34 class A, smoke density GB/T 17651, halogen acid gas content GB/T 17650, sheath moisture-tightness / water-immersion leak test, bending at ≥ 15 × OD, short-circuit to 250 °C, and voltage re-test after fire exposure. A factory test certificate accompanies each drum.


Cable Parameters


BTTRZ 4×35 + 1×16 mm² — Full Parameter Sheet
Flexible mineral-insulated fire-resistant cable · 0.6/1 kV · Cu conductor / mica-tape insulation / corrugated Cu sheath / LSZH outer jacket · per GB/T 19216 (IEC 60331) · 4 large + 1 small core · finished Ø ≈ 30 mm · ≈ 1400 kg/km
Section Parameter Value Unit Remarks / Standard
01 · Identification

Cable type BTTRZ — Flexible mineral-insulated fire-resistant cable (Cu sheath, LSZH outer)

Rated voltage (U0/U) 0.6/1 kV AC 50 Hz; maximum system voltage Um = 1.2 kV

Number of cores 4 × 35 + 1 × 16 — 4 phase/line cores (35 mm²) + 1 neutral/earth core (16 mm²)

Conductor material Tinned annealed copper — Class 5 flexible stranded per GB/T 3956

Insulation material Mica tape (muscovite/phlogopite) + glass-fibre reinforcement — Fire-rated, 950 °C continuous

Inner filler Fire-resistant glass-fibre rope — Hygroscopic / flame-retardant filler

Metal sheath Corrugated (spiralled) copper tube — Continuous fire, moisture and mechanical barrier

Outer jacket Low-smoke zero-halogen (LSZH) polyolefin — Flame-retardant, halogen-free

Standard reference GB/T 19216 / IEC 60331; GB/T 19666; GB/T 12706.1 — Fire-resistant power cable 0.6/1 kV
02 · Conductor

Stranding — 35 mm² (×4) 276 × 0.40 mm — Class 5 tinned copper, flexible lay-up

Conductor diameter — 35 mm² ≈ 8.9 mm Strand-lay diameter (est.)

DC resistance — 35 mm² @ 20 °C ≤ 0.524 Ω/km Maximum per GB/T 3956 Class 5

Stranding — 16 mm² (×1) 126 × 0.40 mm — Class 5 tinned copper, neutral/earth

Conductor diameter — 16 mm² ≈ 6.0 mm Strand-lay diameter (est.)

DC resistance — 16 mm² @ 20 °C ≤ 1.15 Ω/km Maximum per GB/T 3956 Class 5

Conductor flexibility Class 5 (flexible) — Bendable on-site, unlike rigid MI cable
03 · Insulation

Insulation type Mica tape (muscovite / phlogopite) — Wrapped with overlapping tape layers

Insulation thickness per core ≈ 0.7 mm Multiple mica-tape overlaps

Core Ø — 35 mm² (over insulation) ≈ 10.3 mm 8.9 + 2 × 0.7

Core Ø — 16 mm² (over insulation) ≈ 7.4 mm 6.0 + 2 × 0.7

Fire resistance rating 950 °C / 90 min — Per GB/T 19216.21 / IEC 60331-21

Insulation colour coding Phase cores: black/brown/grey/black; neutral: light blue; earth: green-yellow — Per GB/T 6995
04 · Assembly & Filler

Core arrangement 4 large cores + 1 small neutral cabled round — 5-core round lay-up

Filler material Fire-resistant glass-fibre rope — Fills interstices, keeps round shape

Binder tape Glass-fibre tape — Holds bundle before sheath

Assembled bundle Ø ≈ 25 mm Before copper sheath (est.)

Lay-up direction Right-hand (S) — Standard convention
05 · Corrugated Copper Sheath

Sheath material Copper strip, continuously corrugated — Longitudinally welded / spiral-formed

Sheath thickness ≈ 0.3 mm Electrical continuity and earth path

Corrugation pitch ≈ 1.5 mm Allows flexibility and bending

Sheath function Fire barrier + moisture barrier + earth conductor — May serve as protective earth (PE)

Sheath diameter ≈ 26 mm Over bundle (est.)
06 · Outer Jacket

Jacket material LSZH (low-smoke zero-halogen) polyolefin — Flame-retardant, halogen-free

Jacket thickness 1.8 mm Mechanical protection, UV-resistance

Overall finished diameter ≈ 30 mm Cross-referenced industry sample

Approximate cable mass ≈ 1400 kg/km Cu + mica + LSZH build-up

Jacket colour Orange / red (standard fire-cable colour) — For identification; custom available

Mass per 100 m ≈ 140 kg/100 m For drum loading
07 · Electrical

Rated voltage U0/U 0.6/1 kV AC 50 Hz

Maximum system voltage Um 1.2 kV —

DC resistance — 35 mm² @ 20 °C ≤ 0.524 Ω/km GB/T 3956 Class 5

DC resistance — 16 mm² @ 20 °C ≤ 1.15 Ω/km GB/T 3956 Class 5

AC impedance @ 50 Hz — 35 mm² ≈ 0.524 Ω/km R-dominant

Insulation resistance ≥ 36.7 MΩ·km Mica-rated, very high

Capacitance (typical) ≈ 0.45 μF/km Per phase (est.)

Routine test voltage 3.5 kV AC / 5 min — Power-frequency withstand

Air ampacity @ 25 °C ≈ 140 A 4 cores loaded, Cu (est.)
08 · Thermal & Fire

Max continuous conductor temp. 90 °C Normal service

Short-circuit temp. (≤ 5 s) 250 °C Copper limit

Fire-resistance rating 950 °C / 90 min — GB/T 19216.21 / IEC 60331-21

Circuit integrity under fire Maintained — With rated voltage during flame exposure

Flame behaviour Non-flame-spreading — GB/T 18380.34 class A

Smoke emission Low smoke — LSZH jacket

Halogen content Halogen-free — LSZH outer jacket

Service ambient range −15 to +70 °C For fixed installation
09 · Installation

Min bending radius ≥ 15 × OD ≈ 450 mm Fixed installation

Sheath as earth (PE) Allowed — Copper sheath provides protective earth

Termination Special gland and sealing termination — Prevents moisture ingress into mica layer

Laying methods Cable tray, trench, duct, direct burial — Indoor / outdoor / underground

Outdoor / burial note Suitable — LSZH jacket is UV-resistant when correctly sheathed

Special termination kits Required at both ends — Sealing + earth bonding kit
10 · Packing

Standard supply length 500 or 1000 m/drum Custom cut lengths available

Reel / packing type Wooden-steel drum — Sealed until installation

Surface marking BTTRZ, 0.6/1 kV, size, supplier, year, metre marks — Per GB/T 6995

Storage conditions Dry, covered, −15 to +40 °C — Sealed ends to prevent moisture

Transport Drums secured against rolling — Do not drag; heavy cable


Cable Test Parameters


Test Parameters — BTTRZ 4×35+1×16 mm²
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance GB/T 3048.4, 20 °C 35 mm² ≤ 0.524; 16 mm² ≤ 1.15 Ω/km Routine
2 Power-frequency withstand 3.5 kV AC, 5 min No breakdown Routine
3 Insulation resistance GB/T 3048.5 ≥ 36.7 MΩ·km Routine
4 Conductor continuity Visual + electrical All 5 cores continuous Routine
5 Dimensional check Micrometer OD ≈ 30 mm; jacket ≥ 1.8 mm Routine
6 Fire-resistance test GB/T 19216.21, 950 °C, 90 min Circuit integrity maintained, no breakdown Type
7 Flame spread test GB/T 18380.34 class A No vertical flame spread beyond specified char Type
8 Smoke density GB/T 17651 Low smoke output Type
9 Halogen acid gas content GB/T 17650 Halogen-free (LSZH jacket) Type
10 Corrugated Cu sheath continuity Continuity meter Electrically continuous along cable Routine
11 Sheath tightness / moisture test Water immersion / leak test No water ingress Type
12 Bending test ≥ 15 × OD mandrel No damage to sheath or insulation Type
13 Short-circuit test 250 °C, 5 s equivalent No insulation collapse Type
14 Voltage test after fire After 950 °C/90 min fire Withstands 3.5 kV AC Type
15 Marking legibility Visual + rubbing BTTRZ / size / voltage / metre marks legible Routine
16 Core identification Visual + continuity Correct colour-coded conductors identified Routine


Cable Cross Section Structure


Hospital Critical Fire Proof Cable BTTRZ 4x35mm²+1x16mm² Mineral Mi Heating Cable


BTTRZ 4×35+1×16 mm² — Cross-Section Construction Diagram (Schematic)
Layered fire-resistant build-up: tinned Cu conductor → mica-tape insulation → glass-fibre filler → corrugated Cu sheath → LSZH jacket · 0.6/1 kV · GB/T 19216 950 °C/90 min · finished Ø ≈ 30 mm
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor (Cu) Tinned annealed copper, Class 5 flexible — 276×0.40 mm for 35 mm² (×4), 126×0.40 mm for 16 mm² (×1) — ≈ 8.9 / ≈ 6.0 Power conductors; R ≤ 0.524 (35) / 1.15 (16) Ω/km at 20 °C
2 Mica-tape insulation Muscovite/phlogopite mica tape, overlapping wrap, glass-fibre reinforced ≈ 0.7 ≈ 10.3 / ≈ 7.4 Fire-rated dielectric; survives 950 °C / 90 min flame exposure
3 Inner filler & binder Fire-resistant glass-fibre rope fills interstices; glass-fibre binder tape — ≈ 25 (bundle) Keeps round shape, adds thermal insulation, non-hygroscopic
4 Corrugated Cu sheath Continuously corrugated (spiralled) copper tube, longitudinal welded ≈ 0.3 ≈ 26 Fire + moisture barrier; may serve as protective earth (PE)
5 LSZH outer jacket Low-smoke zero-halogen polyolefin, flame-retardant, orange/red 1.8 ≈ 30 (finished) Mechanical + UV protection; halogen-free for public areas
Key Dimensions & Properties (expanded)
Finished cable diameter ≈ 30 mm Cross-referenced industry sample

Approximate cable mass ≈ 1400 kg/km Cu + mica + LSZH build-up

Nominal voltage rating 0.6/1 kV AC 50 Hz; Um = 1.2 kV

Max continuous conductor temp. 90 °C Normal service

Short-circuit temp. (≤5 s) 250 °C Copper limit

Fire-resistance rating 950 °C / 90 min — GB/T 19216.21 / IEC 60331-21

Min bending radius ≥ 15 × OD ≈ 450 mm Fixed installation

DC resistance — 35 mm² ≤ 0.524 Ω/km At 20 °C

DC resistance — 16 mm² ≤ 1.15 Ω/km At 20 °C

Insulation resistance ≥ 36.7 MΩ·km Mica-rated

Routine test voltage 3.5 kV AC / 5 min — Power-frequency withstand

Air ampacity @ 25 °C ≈ 140 A 4 cores loaded, Cu (est.)

Corrugated Cu sheath thickness ≈ 0.3 mm Fire/moisture barrier + PE

Outer jacket thickness 1.8 mm LSZH, halogen-free

Mass per 100 m ≈ 140 kg/100 m For drum loading

Schematic — not to exact scale. Finished Ø ≈ 30 mm and weight ≈ 1400 kg/km from cross-referenced industry samples; conductor/insulation diameters per GB/T 3956 and GB/T 12706.1; ampacity 140 A is an engineering estimate. Values marked (est.) require confirmation against the factory test certificate.


Cable Construction Description


Construction Description — BTTRZ 4×35+1×16 mm² 
Layer-by-layer build-up narrative · 0.6/1 kV fire-resistant power cable · GB/T 19216 950 °C/90 min · tinned Cu / mica / corrugated Cu / LSZH · finished Ø ≈ 30 mm
1. Product Identity & Ratings
BTTRZ 4×35+1×16 is a flexible mineral-insulated fire-resistant power cable rated 0.6/1 kV (Um = 1.2 kV) at 50 Hz, built around four 35 mm² tinned-copper Class 5 flexible phase conductors and one 16 mm² neutral/earth conductor. Unlike rigid magnesium-oxide mineral-insulated cables, BTTRZ uses mica-tape wrapped insulation enclosed in a continuously corrugated copper tube, then jacketed in a low-smoke zero-halogen (LSZH) outer sheath. The cable maintains circuit integrity for at least 90 minutes at 950 °C open-flame exposure (GB/T 19216.21 / IEC 60331-21). Finished diameter is about 30 mm and nominal mass about 1400 kg/km (≈ 140 kg per 100 m), supplied on 500 m or 1000 m wooden-steel drums. With four 35 mm² cores loaded, the cable carries about 140 A in free air at 25 °C (engineering estimate), making it the standard fire-rated feeder for fire pumps, main smoke-exhaust fans and emergency main distribution risers.
2. Tinned Copper Conductors
Each 35 mm² phase conductor is stranded from 276 tinned annealed copper wires of 0.40 mm in Class 5 flexible lay-up, giving a strand-lay diameter of about 8.9 mm and a DC resistance ceiling of 0.524 Ω/km at 20 °C. The 16 mm² neutral/earth conductor uses 126 wires of 0.40 mm, diameter ≈ 6.0 mm, R ≤ 1.15 Ω/km. Tinning prevents copper oxidation under prolonged high-temperature exposure and improves solderability at terminations.
3. Mica-Tape Insulation
Each conductor is wrapped with overlapping muscovite/phlogopite mica tape reinforced with glass-fibre, reaching about 0.7 mm total thickness. Mica is an inorganic mineral that does not burn and retains dielectric strength at temperatures up to 1000 °C — this is the layer that keeps the circuit alive during a fire. The insulation around each 35 mm² core measures about 10.3 mm over mica; the 16 mm² core about 7.4 mm.
4. Filler, Corrugated Copper Sheath & LSZH Jacket
After mica wrapping, four 35 mm² cores and the 16 mm² core are cabled round, with fire-resistant glass-fibre rope filling interstices and a glass-fibre binder tape holding the bundle. A ≈ 0.3 mm corrugated (spiralled) copper tube is then formed continuously around the bundle — this sheath is the mechanical and moisture barrier, provides electrical continuity, and may be used as the protective earth (PE). A 1.8 mm LSZH (low-smoke zero-halogen) polyolefin jacket in standard orange/red is extruded over the copper sheath to the ≈ 30 mm finish, providing abrasion and UV resistance while emitting low smoke and no acid gas in fire.
5. Site Handling & Operational Notes
• Observe the 15 × OD minimum bending radius (≈ 450 mm).  • Use special sealing glands at both ends to keep moisture out of the mica layer.  • The corrugated copper sheath must be earthed at both ends.  • Service ambient −15 to +70 °C; conductor up to 90 °C continuous, 250 °C short-circuit.  • Fire rating 950 °C / 90 min per GB/T 19216.21.  • Termination kits must be ordered with the cable.  • Weight ≈ 140 kg/100 m — requires drum jacks and rated pulling gear.


8. Standards & Conformity. Design and production are governed by GB/T 19216.21 / IEC 60331-21 for fire-resistance (950 °C / 90 min), GB/T 19666-2019 for flame-retardant and fire-resistant cable classification, and GB/T 12706.1-2020 for low-voltage power cables at 0.6/1 kV. Conductors satisfy GB/T 3956 Class 5. General test methods follow GB/T 19216 series and GB 5023. Surface marking complies with GB/T 6995. The LSZH jacket meets halogen-free requirements per GB/T 17650. Cables can also be supplied to IEC 60331, BS 5839, BS 7621 or NEK 606 requirements on request.


9. Packaging, Storage & Logistics. Standard delivery is 500 m or 1000 m per wooden-steel drum, with bespoke cut lengths available on request. Each drum carries type, voltage, size, supplier identity, production year and sequential metre marking per GB/T 6995. Storage should be in dry, covered premises at −15 to +40 °C, shielded from direct sunlight, moisture, oils and sharp objects; drum end seals must remain intact until installation. Because mica is hygroscopic, any drum whose end seal has been damaged must be re-tested for insulation resistance before use. During transit, drums must be secured against rolling and impact.


10. Procurement Specification. State "BTTRZ 0.6/1 kV 4×35+1×16" together with the required length or drum arrangement, and specify whether the corrugated copper sheath is to be used as the protective earth (PE) or whether a separate green-yellow 16 mm² conductor is required. Always order the matching sealing gland and termination kit at both ends. Always request the factory test certificate, which must include the 950 °C / 90 min fire-resistance report, to confirm the actual diameter (≈ 30 mm), weight (≈ 1400 kg/km) and conductor resistances for the production batch.


Hospital Critical Fire Proof Cable BTTRZ 4x35mm²+1x16mm² Mineral Mi Heating Cable


11. Cable Industry FAQ.

  • Q1: When should I choose 35 mm² over 25 mm² for fire-rated circuits? Choose 35 mm² when the emergency load carries up to about 140 A (vs about 110 A for 25 mm²), such as fire pumps up to 30 kW, main smoke-exhaust fans up to 11 kW, or longer riser runs where voltage drop matters. 25 mm² is sufficient for smaller emergency distribution.
  • Q2: Why is the neutral/earth core only 16 mm² while phases are 35 mm²? In typical three-phase balanced loads the neutral carries little current, so it is derated to 16 mm². The corrugated copper sheath additionally provides a continuous protective-earth path, so the separate 16 mm² core serves primarily as a system neutral.
  • Q3: What does "950 °C / 90 min" actually guarantee? During the GB/T 19216.21 / IEC 60331-21 test, the cable is laid in a test furnace, energised at rated voltage, and directly exposed to a 950 °C flame for 90 minutes. The cable must continue to carry the load without electrical breakdown. This is the rating that justifies its use on fire pumps, emergency lighting and escape-route circuits.
  • Q4: Why is the corrugated copper sheath necessary? The copper sheath serves three purposes: (i) physical flame barrier protecting the mica layer; (ii) moisture barrier — mica is hygroscopic and must stay dry; (iii) continuous electrical path that can double as the protective earth (PE).
  • Q5: Why is the jacket LSZH instead of PVC? In a fire, PVC releases dense smoke and hydrochloric acid gas, which are the dominant causes of death in fires. LSZH jacket releases low smoke and no acid gas — essential in tunnels, metros, hospitals and high-rise public buildings where evacuation is slow.
  • Q6: Why must the termination kit be special? Mica tape is hygroscopic: if moisture enters the cable end, the insulation resistance collapses. Standard PVC cable glands are not air- and moisture-tight. The BTTRZ termination kit uses a sealed brass gland with epoxy sealing compound and a heat-shrink boot.
  • Q7: Can the copper sheath replace the separate earth conductor? Yes — the corrugated copper sheath is electrically continuous and can be sized as the protective earth (PE), provided its cross-sectional area and fault-current capacity meet the installation code.
  • Q8: How heavy is this cable compared to ordinary PVC? At ≈ 1400 kg/km it is roughly twice the mass of an ordinary RVV 4×35 flexible cord, because of the corrugated copper sheath and mica layers. This is normal for fire-rated cables and must be planned for in tray loading and pulling.
  • Q9: Can BTTRZ be used outdoors or buried directly? Yes — the LSZH jacket is UV-resistant and the copper sheath is an effective moisture barrier, so BTTRZ can be installed outdoors, in trays or directly in buried trenches.
  • Q10: Which tests confirm acceptability on delivery and before energisation? At delivery, verify the factory fire-resistance certificate (950 °C / 90 min), conductor resistance (35 ≤ 0.524; 16 ≤ 1.15 Ω/km), dimensions (≈ 30 mm), and the drum end-seal integrity. After installation, complete an insulation-resistance test, a 3.5 kV AC / 5 min withstand, and verify both ends of the corrugated copper sheath are properly earthed before energising.
  • Q11: What service life can be expected? When installed, terminated and operated within the stated temperature, voltage and fire ratings, BTTRZ cable is designed for a service life of around 30–40 years in fixed installation. The two failure modes to watch are moisture ingress through improperly sealed terminations and mechanical damage to the corrugated sheath.