Fire Alarm Multi Core Cable 5 Core 1.5m2 RVV For Emergency System
Fire Alarm Multi Core Cable 5 Core 1.5mm² RVV for Emergency System Cable Designation & Meaning Code Meaning RVV R = Flexible copper conductor (Class 5), V = PVC insulation, V = PVC sheath 300/500 V Rated voltage U₀/U = 300/500 V; Uₘ = 500 V 5×1.5 mm² Five flexible cores, each 1.5 mm² copper ...
Stranded Copper Wire 5 Core Cable RVV 5x6.0mm² PVC Flexible 300/500V
Stranded Copper Wire 5 Core Cable RVV 5x6.0mm² PVC Flexible 300/500V Cable Designation & Meaning Code Meaning RVV R = Flexible copper conductor (Class 5), V = PVC insulation, V = PVC sheath 300/500 V Rated voltage U₀/U = 300/500 V; Uₘ = 500 V 5×6.0 mm² Five flexible cores, each 6.0 mm² copper ...
3x240mm2 Flexible Medium Voltage Cable 8.7kV 15kV 3 Core Cable
XLPE Medium Voltage Aluminum Cable YJLV22 3x240mm2 8.7/15kV Armored 3 Core Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 ...
RVVP 2x2.5mm² Braided Copper Shielded Control Cable Protection for Variable Frequency Drive 300/500V
RVVP 2x2.5mm² Braided Copper Shielded Control Cable Protection for Variable Frequency Drive 300/500V Cable Designation & Meaning Code Meaning R Flexible cord V PVC insulation V PVC sheath P Copper braid shield 2×2.5 mm² Two cores of 2.5 mm² copper conductor Construction : Two 2.5 mm² fine-stranded ...
1*25mm² Single Core Cable, 0.6/1kV XLPE Insulation PVC Sheath for Indoor Power Wiring
ZR-YJV 1*25mm² Flame Retardant Single Core Cable, 0.6/1kV Pure Copper XLPE Insulation PVC Sheath for Indoor Power Wiring ZR-YJV 1×25 mm² — Detailed Product Introduction Cable Designation & Meaning Code Meaning ZC Flame retardant C— IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) ...
1 X 70mm2 Single Core Cable Solid Copper XLPE Insulation PVC Jacket For Building Power
ZR-YJV 1*70mm² Single Conductor , 0.6/1kV Solid Copper, XLPE Insulation PVC Jacket for Building Power Cable Designation & Meaning Code Meaning ZC Flame retardant C— IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 1×70 mm² Single core, 70 mm² copper conductor ...
ZR-YJV 4*10mm² Flame Retardant 4 Core Cable, 0.6/1kV, XLPE Insulation PVC Jacket for Construction Power
ZR-YJV 4*10mm² Flame Retardant 4 Core Cable, 0.6/1kV, XLPE Insulation PVC Jacket for Construction Power Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×10 mm² Four equal cores of 10 mm² copper ...
ZR-YJV 4x95mm² Flame Retardant Copper Core Power Cable for Industrial Construction
ZR-YJV 4x95mm² Flame Retardant Copper Core Power Cable for Industrial Construction Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×95 mm² Four equal cores of 95 mm² copper conductor Construction : ...
ZR-YJV 4*120mm² Flame Retardant Copper Power Cable for Building & Industrial Wiring
ZR-YJV 4*120mm² Flame Retardant Copper Power Cable for Building & Industrial Wiring Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×120 mm² Four equal cores of 120 mm² copper conductor Construction ...