ZR-YJV 4x95mm² Flame Retardant Copper Core Power Cable for Industrial Construction

ZR-YJV 4x95mm² Flame Retardant Copper Core Power Cable for Industrial Construction

Basic Properties

country of origin
China
brand name
TD
certificate
CE/ISO/CCC
product model
ZR-YJV 4x95mm2

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
10000 meters per month

Product Summary

ZR-YJV 4x95mm² Flame Retardant Copper Core Power Cable for Industrial Construction Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×95 mm² Four equal cores of 95 mm² copper conductor Construction: ...

Product Details

Highlight:

zr-yjv 4 cores cable

,

zr-yjv 25 sq mm 4 core cable

,

copper 4 cores cable

Conductor (×4):
Bare Annealed Copper, Class 2 Stranded, 19×∅2.52 Mm, Conductor Ø ≈ 12.4–13.0 Mm
Conductor nominal area (per core):
95 Mm²
Number of cores:
4
Conductor construction:
Class 2, 19×∅2.52 Mm
Conductor diameter (approx.):
12.4–13.0 Mm
Insulation (×4):
XLPE
Insulation thickness:
1.1 Mm (95 Mm² Class)
Diameter over insulated core:
13.7–15.2 Mm
Filler / binder:
FR PP Filler + FR Tape
Outer sheath:
Flame-retardant PVC (ZR Grade)
Sheath thickness:
2.1 Mm (multi-core Rule, 70–120 Mm² Typically 2.0–2.1 Mm)
Overall cable diameter:
32.5 – 41.0 Mm
Approx. weight:
3800 – 4200 Kg/km
Long-term service temp.:
90 °C
Short-circuit temp. (≤5 s):
250 °C
Emergency overload:
105–130 °C
Routine test:
3.5 KV AC / 5 Min; Type Test 4.0 KV
Volume resistivity @90 °C:
≥ 10¹² Ω·cm

Product Description

ZR-YJV 4x95mm² Flame Retardant Copper Core Power Cable for Industrial Construction

Cable Designation & Meaning

Code

Meaning

ZC

Flame retardant Class C

YJ

Cross-linked polyethylene (XLPE) insulation 

V

Polyvinyl chloride (PVC) sheath 

4×95 mm²

Four equal cores of 95 mm² copper conductor


Construction: Four 95 mm² copper conductors (3 phase + 1 neutral), XLPE insulation, PVC outer sheath. No metallic screen/armour as standard (can be added on request).

ZR-YJV 4x95mm² Flame Retardant Copper Core Power Cable for Industrial Construction



ZC-YJV 4×95 mm² — LV Flame-Retardant Four-Core Power Cable — Specification

1. Overview & Ratings. ZC-YJV 4×95 is a heavy four-core LV main-feeder cable rated 0.6/1 kV (Um 1.2), 90 °C working, ZC class C PVC sheath: four equal 95 mm² compacted copper cores (L1/L2/L3 phases plus a full neutral), dry-cured XLPE, unarmored. OD ≈ 30 mm, ≈ 4300 kg/km (est.), ≈ 230 A per core free air at 30 °C (est.). Scope: heavy power distribution, main feeders, large motors and pump stations — not 950°C fire duty.


2. Construction Stack (Inner → Outer, expanded).


Layer / Feature Build Function
Conductors L1/L2/L3/N 4×95 compacted Cu, Class 2, ≈19 strands R ≤0.206 Ω/km
Strand compaction Concentric layers rolled compact per core Compact heavy bundle, clean lugs
XLPE insulation (all cores) Dry-cured PE, ≈1.6 mm Uniform 90°C dielectric
2+2 core laying Four equal cores in two rows Round heavy finished bundle
PVC ZC sheath Class C, ≈1.7 mm overall Self-extinguishes, prints clear
Jacket print Continuous type/size/voltage/length On-site readable spec


3. Electrical Characteristics. All four cores R ≤ 0.206 Ω/km @20 °C. Test 3.5 kV AC / 5 min; ≈ 230 A per core (est., air 30 °C); short-circuit ≈ 11 kA / 1 s (est.); 50/60 Hz; unscreened; low-loss XLPE; high stable insulation resistance.

Insulation & Sheath Data

Property

Value

Insulation material

XLPE (cross-linked polyethylene)

Outer sheath material

PVC (ST₂)

Long-term service temp.

90 °C (continuous)

Max. conductor temp. (normal)

90 °C

Short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Test voltage AC (5 min)

3.5 kV

Dielectric strength

≥ 20 kV/mm

Volume resistivity @20 °C

≥ 1×10¹⁴ Ω·cm

Shield

None as standard (can be added)

Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

GB/T 12706.1 / IEC 60502-1

Max. system voltage

1.2 kV AC

—

Test voltage AC (5 min)

3.5 kV

Routine test

DC resistance @20 °C

≤ 0.193 Ω/km per core

GB/T 3956 Class 2 Cu max (95 mm²)

AC resistance @90 °C (est.)

≈ 0.247 Ω/km per core

—

Current rating in air (30 °C)

3-phase: 245 A​

4×95, touching, in free air

Current rating in tray (30 °C)

3-phase: 270 A​

4×95, spaced 2×OD

Current rating buried in ground (20 °C, thermal resistivity 1.2 K·m/W)

3-phase: 255 A​

direct buried

Current rating in conduit (30 °C)

3-phase: 215 A​

—

Short-circuit current (1 s, Cu, 250 °C)

≈ 10.5 kA (10,500 A) per core

—

Capacitance (core-to-sheath, approx.)

≈ 0.22 µF/km

XLPE

Inductive reactance (approx.)

≈ 0.08 Ω/km

at 50 Hz

Frequency

50/60 Hz AC

—


Reference values: 4×95 at 245 A three-phase, 400 V → max load ≈ 147 kW​ (cos φ = 0.8). Suitable for large three-phase distribution with full-size neutral, heavy industrial motors, and main building feeders.


4. Thermal & Flame. 90 °C continuous, 250 °C short-time; ZC class C self-extinguishing — flame retardancy, not 950°C integrity; survives large-unit start-stop and feeder cycling; indoor preferred, UV jacket optional.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

90 °C (continuous)

Max. short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Min. installation ambient temp.

0 °C (below 0 °C requires preheating)

Service ambient range

−20 °C to +90 °C

Flexing temp. range

0 °C to +90 °C

Fire Performance (ZC-YJV — Flame Retardant C)

Property

Value / Requirement

Flame retardant

GB/T 18380.12 / IEC 60332-1-2​ (single cable, self-extinguishing)

Flame retardant class

Class C​ (ZC) per GB/T 19666

Halogen content

Contains halogen (PVC sheath)

Smoke density

Not low-smoke (PVC)

Corrosivity

Corrosive (PVC)

Toxicity

Toxic fumes when burned (PVC)

EMI shielding

None (no metallic screen/armour)


5. Installation Practice & Handling. 95 mm² lugs on all four cores, heavy glands to ≈30 mm OD, hydraulic crimp/torque per table; bend ≥ 15×OD ≈ 450 mm; apply duct/tray derating; keep the bundle tidy; verify four-core continuity, phase sequence, neutral and insulation before energizing.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 15 × OD → ≈ 495 mm at Ø33.0 mm

four-core unarmoured

Max. pulling tension

1,425 N per core (95 mm² × 15 N/mm²)

Cu conductor limit

Direct burial

Suitable (with sand bedding)

—

Surface mounting

Heavy-duty cable tray, ladder, cleats

—

Conduit ID

≥ 65 mm

—

Fixing

heavy-duty cleats, cable ties

—

Impact resistance

Moderate

—

Water resistance

Good (PVC sheath)

—

UV resistance

Fair (PVC degrades outdoors, use UV-resistant PVC or conduit)

—

Flex life

Good (Class 2 stranded)

fixed installation

Termination note

Standard compression lugs or mechanical connectors

—


6. Typical Service Applications. Heavy three-phase main feeders, large motors, pump stations, plant main supplies, switchboard-to-sub-board trunks and vertical riser branches.

ZR-YJV 4x95mm² Flame Retardant Copper Core Power Cable for Industrial Construction


7. Testing & QA Regime (16 items). Routine: DC resistance on all four 95 cores, 3.5 kV withstand, insulation resistance, four-core continuity, insulation thickness, sheath thickness, dimensional check, strand construction, eccentricity, core color identification, print legibility, mass, jacket finish, packing inspection. Type: ZC flame test, short-circuit rating, sheath mechanical.


Cable Parameters


ZR-YJV 4×95 mm² Flame-Retardant Copper-Conductor XLPE-Insulated PVC-Sheathed Power Cable — Product Parameters (0.6/1 kV, Four-Core)
Construction: CU / XLPE / PVC, 4 cores  •  Standards: GB/T 12706.1, IEC 60502-1 (cable), GB/T 3956 (conductor), GB/T 19666 & GB/T 18380 (flame retardance)  •  Nominal values for reference — confirm against factory test certificate
No. Category Parameter Value Unit Notes / Standard Reference
A. Product Identification
1 Identification Product name Flame-retardant copper-conductor XLPE-insulated PVC-sheathed power cable (four-core) — Designation ZR-YJV; "ZR" = flame-retardant, halogen-containing
2 Identification Model designation ZR-YJV 4×95 — 4 cores × 95 mm²; Cu / XLPE / PVC
3 Identification Design standards GB/T 12706.1; IEC 60502-1 — Conductor: GB/T 3956 / IEC 60228; fire rating: GB/T 19666, GB/T 18380
4 Identification Rated voltage U0/U 0.6/1 kV Max system voltage Um = 1.2 kV
5 Identification Rated frequency 50 Hz AC power distribution
6 Identification Number of cores 4 — Three phases (L1/L2/L3) + neutral (N)
7 Identification Nominal cross-sectional area 95 mm² Per core; nominal section per GB/T 3956
B. Cable Construction (from conductor to outer sheath)
8 Conductor Material Plain annealed copper (Cu) — High-conductivity copper
9 Conductor Conductor class Class 1 or Class 2 (typical: Class 2, stranded) — GB/T 3956 / IEC 60228
10 Conductor Typical stranding construction (per core) 19 wires × 2.52 mm (19/2.52) — Class 2 round stranded (1+6+12 concentric); nominal 95 mm² per core
11 Conductor Conductor diameter (per core) ≈ 12.60 mm Ø of the 19/2.52 stranded core (5 × 2.52)
12 Conductor Max. DC resistance of conductor at 20 °C 0.193 Ω/km GB/T 3956, Class 2 copper
13 Insulation Material Cross-linked polyethylene (XLPE) — Thermally cross-linked; natural/transparent
14 Insulation Nominal insulation thickness 1.1 mm GB/T 12706.1 / IEC 60502-1 (0.6/1 kV, 70–95 mm² band)
15 Insulation Diameter over insulation (per core) ≈ 14.80 mm ≈ 12.60 + 2 × 1.1 (calculated)
16 Lay-up Core assembly Four insulated cores laid up around a central non-hygroscopic filler; binder tape over the bundle — Round construction; classic 4-core geometry
17 Sheath Material Flame-retardant polyvinyl chloride (PVC, ST2 type) — Colour: black (or as ordered)
18 Sheath Nominal sheath thickness 2.0 mm GB/T 12706.1 / IEC 60502-1 (Mingda four-core table)
19 Dimensions Approx. overall diameter ≈ 41.2 mm Mingda 41.2 (four-core unarmored)
20 Dimensions Approx. cable weight ≈ 4166 kg/km Mingda 4166 (aluminium version ≈ 1740 kg/km)
C. Electrical Performance
21 Electrical Max. DC conductor resistance at 20 °C 0.193 Ω/km GB/T 3956; routine measurement (per core)
22 Electrical Power-frequency withstand voltage (routine test) 3.5 kV / 5 min, no breakdown — AC 50 Hz; per GB/T 12706.1 / IEC 60502-1
23 Electrical Insulation resistance (finished cable, 20 °C) ≥ 36.7 MΩ·km Typical finished-cable reference for 0.6/1 kV XLPE cables
24 Electrical XLPE volume resistivity at 20 °C ≥ 1 × 10¹² Ω·cm Material-level requirement (manufacturer reference)
25 Electrical Capacitance (approx., per core) ≤ 0.45 μF/km Manufacturer reference value
26 Electrical Reference ampacity — in air, 25 °C, four cores loaded ≈ 245 A Mingda 245 A; Lvbao 4×95+1×50 also 245 A @25 °C
27 Electrical Reference ampacity — direct burial, 25 °C ≈ 270 A Mingda 270 A; Lvbao 4×95+1×50 270 A; soil thermal resistivity dependent
D. Thermal Performance
28 Thermal Max. continuous conductor temperature 90 °C XLPE insulation temperature class
29 Thermal Max. conductor temperature under short-circuit (≤ 5 s) 250 °C Per GB/T 12706.1 / IEC 60502-1
30 Thermal Ambient service temperature range -20 to +45 °C Per manufacturer datasheet family; check project specification
31 Thermal Min. installation (laying) temperature 0 °C Pre-heat the cable if ambient is below 0 °C
E. Flame Retardance (ZR)
32 Flame retardance Flame-retardant class ZC (class C) by default for "ZR" — GB/T 19666; ZA / ZB available on request; halogen-containing PVC (not LSZH)
33 Flame retardance Single-cable vertical flame-spread test Pass — GB/T 18380.12
34 Flame retardance Bunched flame-spread test (class C) Char extent ≤ 2.5 m above burner bottom edge — GB/T 18380.35: non-metallic volume ≥ 1.5 L/m; flame application 20 min
35 Flame retardance Halogen content Halogen-containing (PVC) — For low-smoke, zero-halogen requirement select WDZ-YJY (LSZH) type
F. Installation
36 Installation Min. bending radius — multi-core cable ≥ 15 × OD — GB 50168 practice for multi-core XLPE cables
37 Installation Laying methods Conduit, tray, cable trench, duct, building trunking, supported/suspended aerial — Direct burial with mechanical protection where permitted
38 Installation Site withstand test after installation DC 4U0 = 2.4 kV, 15 min (recommended) — Per utility procurement standard Q/GDW 13244.1-2018
G. Packing & Delivery
39 Packing Standard delivery length 100 m per coil/drum (or as ordered) — Typical industry practice; custom lengths available
40 Packing Cable marking Model, rated voltage, manufacturer, year of manufacture, sequential length marks — Per GB/T 6995 / project specification
41 Packing Packing form Coil (carton drum) / wooden drum / export packing — As per customer requirement


Cable Test Parameters


ZR-YJV 4×95 mm² — Test / Verification Parameters (per GB/T 12706.1 & IEC 60502-1)
Test Stage Test Item Method / Standard Requirement / Acceptance Criterion Notes
Routine test Conductor DC resistance measurement GB/T 3956 (IEC 60228) ≤ 0.193 Ω/km at 20 °C (per core) Measured on every production length
Routine test Power-frequency withstand voltage GB/T 12706.1 / IEC 60502-1 3.5 kV AC, 5 min, no breakdown Applied between each conductor and earth/water; 50 Hz
Routine test Construction check — insulation & sheath thickness, outer diameter GB/T 2951 Within GB/T 12706.1 tolerances Insulation ≥ 1.1 mm nominal; sheath ≥ 2.0 mm nominal
Sample test Hot set (thermal elongation) test — XLPE insulation GB/T 12706.1 §16.3.13 / GB/T 2951.11 200 ± 3 °C, 15 min, stress 0.2 MPa: elongation under load ≤ 175 %; permanent elongation after cooling ≤ 15 % Verifies degree of cross-linking
Sample test Conductor construction & diameter check GB/T 3956 Class 2; 19 × 2.52 mm; Ø ≈ 12.60 mm Sampled per batch
Type test Single-cable vertical flame-spread test (flame retardance) GB/T 18380.12 No flame spread; charring does not reach top reference point ZR / ZC flame-retardant property
Type test Bunched flame-spread test, class C GB/T 18380.35 Char extent ≤ 2.5 m above burner bottom edge; flame application 20 min; non-metallic volume ≥ 1.5 L/m Class ZC per GB/T 19666
Type test Bending test (mechanical) GB/T 12706.1 Bend around specified mandrel without insulation/sheath damage Mandrel diameter related to cable OD (multi-core)
Post-installation DC withstand test after installation Q/GDW 13244.1-2018 (recommended practice) 4U0 = 2.4 kV DC, 15 min, no breakdown For new installations; verify project specification
Optional Insulation resistance measurement at 20 °C Manufacturer test method ≥ 36.7 MΩ·km (typical finished-cable value) Not a routine item in GB/T 12706.1; confirm with factory
Optional XLPE volume resistivity at 20 °C Manufacturer / material test ≥ 1 × 10¹² Ω·cm Material-level reference


Cable Cross Section Structure


ZR-YJV 4x95mm² Flame Retardant Copper Core Power Cable for Industrial Construction


ZR-YJV 4×95 mm² — Cable Cross-Section Structure (Schematic)
Four-core construction from conductor to outer sheath · nominal values per GB/T 12706.1 / IEC 60502-1 · not to exact scale
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor (Cu) × 4 Annealed copper, Class 2 stranded — 19 × 2.52 mm per core (19/2.52, 1+6+12), nominal 95 mm² per core — ≈ 12.60 (Ø per core) Current-carrying element; max DC resistance ≤ 0.193 Ω/km @ 20 °C (per core)
2 Insulation (XLPE) × 4 Cross-linked polyethylene 1.1 ≈ 14.80 (Ø per core, over insulation) Dielectric barrier; rated 90 °C continuous; withstands 3.5 kV / 5 min
3 Core lay-up Four insulated cores laid up around central non-hygroscopic filler; binder tape — ≈ 35.7 (Ø over lay-up, calc.) Forms a round assembly for sheathing
4 Outer sheath (PVC) Flame-retardant PVC, ST2 type, black 2 ≈ 41.2 (Ø overall) Mechanical & moisture protection; flame retardance ZC (ZR) per GB/T 19666
Key Dimensions & Properties
Overall diameter ≈ 41.2 mm Mingda four-core unarmored table

Approx. cable weight ≈ 4166 kg/km Mingda 4166 (Al ≈ 1740)

Rated voltage 0.6/1 kV AC 50 Hz; max system voltage Um = 1.2 kV

Max conductor temperature 90 / 250 °C Continuous / short-circuit (≤ 5 s)

Min. bending radius (multi-core) ≥ 15 × OD — OD = actual cable diameter

Schematic — not to exact scale. Nominal values for reference; confirm against factory test certificate.


Product Structure Introduction


Product Structure Introduction — ZR-YJV 4×95 mm² 
Four-core layered construction description, from conductor to outer sheath · per GB/T 12706.1 & IEC 60502-1 · CU / XLPE / PVC · 0.6/1 kV
1. Document Scope
ZR-YJV 4×95 is a flame-retarded four-core cable for 0.6/1 kV AC networks, built on the copper / XLPE / PVC platform to GB/T 12706.1 / IEC 60502-1, with conductor compliance to GB/T 3956 / IEC 60228 and flame classification per GB/T 19666 (ZC default). Approx. outside diameter 41.2 mm, weight 4166 kg/km; normally supplied in 100 m coils or drums.
Four identical 95 mm² cores deliver 245 A per cable in air, making the type a common choice for dense urban risers and plant feeders.
2. Conductor Construction
Each 95 mm² core is formed from nineteen 2.52 mm annealed copper wires (19/2.52) in a 1+6+12 concentric arrangement, Class 2, reaching ≈ 12.60 mm diameter. The DC resistance limit is 0.193 Ω/km at 20 °C. This heavier core still keeps good flexibility because of the fine-wire lay-up.
3. Insulation Construction
XLPE is applied at 1.1 mm, the wall retained through the 70–95 mm² band, so the over-insulation diameter sits at ≈ 14.80 mm per core. The insulation supports 90 °C continuous service, 250 °C short-circuit peaks for five seconds, volume resistivity ≥ 1×10¹² Ω·cm and the routine 3.5 kV AC five-minute proof.
4. Cabling, Filling & Sheathing
The four cores are laid up around a dry central filler into a round bundle near 35.7 mm and held by binder tape, then sheathed with 2.0 mm of flame-retarded ST2 PVC to close at ≈ 41.2 mm. Fire performance meets ZC under GB/T 18380.12 and GB/T 18380.35; because PVC contains halogen, LSZH schemes should switch to WDZ-YJY.
5. Use & Care Notes
• Bending radius not below 15 × OD.  • Execute the DC 4U0 = 2.4 kV / 15 min site test before energising.  • Ambient −20 to +45 °C; pre-heat drums for pulls under 0 °C.  • Apply ambient, grouping and burial derating to the quoted ampacity.  • Use lugs and glands sized for the ≈ 12.60 mm core.


8. Factory Advantages.

  • Equal-size four-core build — full neutral handles large-unit unbalance and harmonic return without extra selection.
  • Stable XLPE cure — even cross-linking keeps the 90°C dielectric consistent on long main feeders.
  • Dosed ZC compound — self-extinguishing jacket protects switchrooms and plant rooms from flame spread.
  • Length-on-demand — cut to exact main feeder meter with sealed ends.
  • Uniform resistance log — all four 95 cores' R recorded to lot for balanced performance.
  • Continuous print line — type, size, ZC, voltage and length readable along the feeder run.
  • Phase-color option — L1/L2/L3/N colors reduce wiring errors at main switchboards.
  • Heavy drum pack — heavy section on a rated wooden drum, both ends moisture-sealed.
  • Certified QA pack — routine + type test record shipped per batch for commissioning.

ZR-YJV 4x95mm² Flame Retardant Copper Core Power Cable for Industrial Construction


9. Packaging, Storage & Logistics. Cut to measured main feeder length on a heavy wooden drum with sealed ends; continuous marking; store dry indoor on drum supports, shaded, avoid direct UV.


ZR-YJV 4x95mm² Flame Retardant Copper Core Power Cable for Industrial Construction


10. Procurement Specification. State "ZC-YJV 4×95", length, class C, phase colors; note the full neutral for large-unit unbalance and not fire-rated; request the four-core resistance log and 16-item QA record. Est. values confirmed against the factory certificate.


11. Cable Industry FAQ.

  • Q1: How does 4×95 differ from 4×16? A large size up: cores 95 vs 16 mm²; OD 30 vs 14 mm, mass 4300 vs 950 kg/km, current 230 vs 65 A, resistance 0.206 vs 1.15 Ω/km; built for heavy main feeders rather than small lighting branches.
  • Q2: Why a full-size neutral? Large units, drives and rectifiers draw neutral current and harmonics; an equal 95 neutral prevents overheating.
  • Q3: Is ZC fire-resistant? No. Class C self-extinguishes; it does not hold live at 950°C/180min.
  • Q4: DC resistance values? All four 95 mm² cores ≤0.206 Ω/km at 20°C.
  • Q5: Screen or armor? Unscreened standard; add braid near VFD EMI; steel-tape armor for buried ground-crushing duty.
  • Q6: Current per core? ≈230 A (est.) free air 30°C; derate in crowded ducts.
  • Q7: Bending? ≈450 mm (15×OD); use bending tools and sheaves.
  • Q8: Connectors? 95 mm² lugs on L1/L2/L3/N; gland to ≈30 mm OD.
  • Q9: Indoor or outdoor? Indoor preferred; specify UV-stabilized jacket for exposed runs.
  • Q10: Packing? Heavy wooden drum with moisture-sealed ends.
  • Q11: What proof ships? Four-core resistance log + 16-test record; est. values confirmed against certificate.