"and other insulations flexible copper wire conductor"
- 90 Items Found
Yellow PVC Copper Single Core Switch Wire 450v 750V Lighting Control Cable
Yellow BV 2.5mm² PVC Copper Single Core Switch Wire 450/750V Lighting Control Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction : Plain copper conductor ...
RVVP 2x6.0mm² Extra High Current Shielded Heavy Duty Industrial Power Control Cable Braided Copper 300/500V
RVVP 2x6.0mm² Extra High Current Shielded Heavy Duty Industrial Power Control Cable Braided Copper 300/500V Cable Designation & Meaning Code Meaning R Flexible cord V PVC insulation V PVC sheath P Copper braid shield 2×6.0 mm² Two cores of 6.0 mm² copper conductor Construction : Two 6.0 mm² fine...
BV 2.5mm² Green Building Wire Solid Copper Single Core PVC Insulated 450/750V Earth Wiring
BV 2.5mm² Green Building Wire Solid Copper Single Core PVC Insulated 450/750V Earth Wiring Cable Designation & Meaning Code Meaning B Building Wire V PVC insulation 1×2.5 mm² Single core of 2.5 mm² copper conductor Green White PVC insulation (for civil indoor visible wiring) Construction : One 2.5 ...
BV 2.5mm² Green-Yellow Building Wire Solid Copper Single Core PVC Insulated Protective Earth Cable
BV 2.5mm² Green-Yellow Building Wire Solid Copper Single Core PVC Insulated Protective Earth Cable Cable Designation & Meaning Code Meaning B Building Wire V PVC insulation 1×2.5 mm² Single core of 2.5 mm² copper conductor Green-Yellow White PVC insulation (for civil indoor visible wiring) ...
1*25mm² Single Core Cable, 0.6/1kV XLPE Insulation PVC Sheath for Indoor Power Wiring
ZR-YJV 1*25mm² Flame Retardant Single Core Cable, 0.6/1kV Pure Copper XLPE Insulation PVC Sheath for Indoor Power Wiring ZR-YJV 1×25 mm² — Detailed Product Introduction Cable Designation & Meaning Code Meaning ZC Flame retardant C— IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) ...
2x35mm2 2 Cores Cable Stranded Copper Low Voltage Power Cable ZR Grade
ZR-YJV 2*35mm² Flame Retardant 2 Core Cable, 0.6/1kV Stranded Copper, XLPE Insulation PVC Jacket for Construction Power Cable Designation & Meaning Code Meaning ZC Flame retardant C (成束燃烧C类阻燃) — IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 2×35 mm² Two cores...
2 X 50mm2 2 Core Shielded Cable Pvc Jacket Wire For Construction Power
ZR-YJV 2*50mm² Flame Retardant 2 Core Cable, 0.6/1kV Stranded Copper, XLPE Insulation PVC Jacket for Construction Power Cable Designation & Meaning Code Meaning ZC Flame retardant C — IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 2×50 mm² Two cores, 50 mm² ...
BTTRZ X50mm2+1x25mm2 Fire Resistant Cable Mineral Emergency Power Copper Sheathed Cable
BTTRZ x50mm²+1x25mm² Mineral Insulated Fire Resistant Copper Sheathed Cable for Emergency Power Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire/power cable) T Copper conductor (Tong = copper) T Copper sheath (Tong = copper) R Flexible (Rou = flexible) Z Heavy ...
2 X 70mm2 2 Cores Cable ZR-YJV Flame Retardant PVC Insulation Jacket 0.6/1kV
ZR-YJV 2*70mm² Flame Retardant 2 Core Cable, 0.6/1kV, XLPE Insulation PVC Jacket for Construction Power Cable Designation & Meaning Code Meaning ZC Flame retardant C — IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 2×70 mm² Two cores, 70 mm² copper conductor ...