BV 2.5mm² Green Building Wire Solid Copper Single Core PVC Insulated 450/750V Earth Wiring
Product Summary
Product Details
2.5mm² green building wire
,solid copper single core wire
,PVC insulated earth wiring
Product Description
BV 2.5mm² Green Building Wire Solid Copper Single Core PVC Insulated 450/750V Earth Wiring
Cable Designation & Meaning
|
Code |
Meaning |
|---|---|
|
B |
Building Wire |
|
V |
PVC insulation |
|
1×2.5 mm² |
Single core of 2.5 mm² copper conductor |
|
Green |
White PVC insulation (for civil indoor visible wiring) |
Construction: One 2.5 mm² solid copper conductor, white PVC insulation applied directly over the conductor.

BV 1×2.5 mm² (Green) — Single-Core PVC Insulated Copper Building Wire — Specification
1. Overview & Ratings
BV 1×2.5 (Green) is a 450/750 V single-core PVC insulated building wire built around one solid pure annealed copper conductor (bare, not tinned). The plain green jacket is allocated to a dedicated auxiliary or phase conductor under the project colour schedule, providing a stable, easily recognised circuit identity inside panels and raceways. A single 2.5 mm² copper wire carries each run; there is no braid, no inner sheath and no outer jacket. Finished OD ≈ 3.4 mm, ≈ 29 kg/km (est.), rated ampacity ≈ 20–25 A in conduit. Service range -15 to +70 °C. Plain green must not be confused with protective earthing, which always uses green-yellow striped insulation. Fixed indoor wiring only.
2. Construction Stack (Inner → Outer, expanded)
| Layer / Feature | Build | Function |
|---|---|---|
| Conductor | Pure annealed Cu, solid Class 1, Ø 1.78 mm | R ≤ 7.41 Ω/km, fixed wiring |
| Insulation | Green PVC ≈ 0.8 mm wall | 450/750 V dielectric, auxiliary/phase ID |
| Shield | None | Single-core unshielded wire |
| Outer jacket | None | Insulation forms the outer layer |
3. Electrical Characteristics
DC resistance ≤ 7.41 Ω/km at 20 °C per GB/T 3956 Class 1 pure copper. Rated 450/750 V. Estimated load capacity ≈ 20–25 A in conduit at 30 °C, up to ≈ 32 A in free air, reduced when bundled in enclosures. Insulation resistance ≥ 20 MΩ·km. Every routine coil passes a 2000 V AC withstand test held 5 minutes. Typical capacitance ≈ 150 pF/m at 1 kHz. Since each wire runs one conductor, its circuit role is established by matching the green jacket and printed marking to the one-line diagram; colour alone should never be treated as proof of phase, neutral or earth without cross-checking the schedule.
Insulation & Sheath Data
|
Property |
Value |
|---|---|
|
Insulation material |
White PVC (Type TI1 or TI2) |
|
Outer sheath material |
None (non-sheathed) |
|
Shield material |
None |
|
Long-term service temp. |
70 °C (continuous, TI1/TI2) |
|
Max. conductor temp. (normal) |
70 °C |
|
Short-circuit temp. (≤5 s) |
160 °C |
|
Emergency overload temp. |
100 °C (≤1 h) |
|
Test voltage AC (5 min) |
2.5 kV |
|
Dielectric strength |
≥ 20 kV/mm |
|
Volume resistivity @20 °C |
≥ 1×10¹² Ω·cm |
Electrical Parameters
|
Parameter |
Value |
Note |
|---|---|---|
|
Rated voltage U₀/U |
450 / 750 V |
GB/T 5023.3 (fixed wiring) |
|
Max. system voltage |
500 V AC / 750 V DC |
— |
|
Test voltage AC (5 min) |
2.5 kV |
Routine test |
|
DC resistance @20 °C |
≤ 7.41 Ω/km |
GB/T 3956 Class 1 Cu max (2.5 mm²) |
|
AC resistance @70 °C (est.) |
≈ 9.28 Ω/km |
— |
|
Current rating in air (30 °C) |
24 A (reference, single-core open) |
typical residential |
|
Current rating in conduit (30 °C) |
20 A (reference, 2-core conduit) |
typical installation |
|
DC current capacity |
24 A |
— |
|
Short-circuit current (1 s, Cu, 160 °C) |
≈ 275 A |
— |
|
Capacitance (core-to-ambient, approx.) |
≈ 0.10 µF/km |
PVC |
|
Inductive reactance (approx.) |
≈ 0.10 Ω/km |
at 50 Hz (single-core) |
|
Frequency |
50/60 Hz AC, DC |
— |
Reference values: BV 2.5 (white) at 24 A, 230 V AC → max load ≈ 5,520 VA (typical lighting/socket circuit). At 24 V DC → max load ≈ 576 W.
4. Thermal & Flame Behaviour
Normal continuous operation -15 to +70 °C; short-circuit withstand up to 160 °C for up to 5 seconds. The green PVC compound meets IEC 60332-1 flame retardancy and self-extinguishes once the ignition source is removed. It is halogen-containing PVC, so in a fire it releases HCl gas; avoid it in public, high-density or escape-route wiring where LSZH insulation is mandated. The medium green surface keeps a tidy appearance and masks light dust and minor marks better than pale jackets, but it should still stay inside conduit, trunking or a closed tray to avoid long-term sunlight and abrasion. Bare copper contacts belong in dry, enclosed locations only.
Temperature Characteristics
|
Property |
Value |
|---|---|
|
Max. conductor operating temp. |
70 °C (continuous) |
|
Max. short-circuit temp. (≤5 s) |
160 °C |
|
Emergency overload temp. |
100 °C (≤1 h) |
|
Min. installation ambient temp. |
−15 °C |
|
Service ambient range |
−15 °C to +70 °C |
|
Flexing temp. range |
Not recommended for flexing |
Fire Performance (BV — PVC, Non-Low-Smoke)
|
Property |
Value / Requirement |
|---|---|
|
Flame retardant |
GB/T 18380.3 / IEC 60332-3 (Category A/B/C as specified) |
|
Halogen content |
Contains halogen (PVC) |
|
Smoke density |
Not low-smoke (IEC 61034-2 not applicable) |
|
Corrosivity |
Corrosive (HCl emission from PVC) |
|
Toxicity |
Toxic fumes when burned (CO, HCl) |
|
EMI shielding |
None |
|
UV resistance |
Poor (PVC degrades outdoors, use conduit) |
|
Water resistance |
Limited (PVC insulation only) |
5. Installation Practice & Handling
Minimum bend radius ≥ 4×OD ≈ 14 mm. The solid Class 1 core is stiff and dimensionally stable; lay out straight runs with generous corner radii and avoid repeated back-and-forth bending. Strip the green jacket cleanly, seat the solid wire fully into the terminal block or lug, and tighten to the rated torque. Before connecting, confirm on the one-line diagram whether this green conductor acts as the designated auxiliary or phase in that circuit. Route live, neutral and earth together in the same conduit; keep plain green physically separate from any green-yellow striped PE wire to prevent misidentification during later maintenance. Record insulation resistance and continuity before energizing.
Mechanical & Installation Parameters
|
Parameter |
Value |
Remarks |
|---|---|---|
|
Minimum bending radius |
≥ 4 × OD → ≈ 15 mm at Ø3.7 mm |
solid conductor |
|
Max. pulling tension |
150 N (2.5 mm² × 60 N/mm²) |
Cu conductor limit |
|
Direct burial |
Not recommended (PVC, no sheath, water ingress) |
— |
|
Surface mounting |
Conduit, trunking, surface-mounted wiring channel, DIN rail |
— |
|
Conduit ID |
≥ 16 mm (single), ≥ 20 mm (multiple) |
— |
|
Fixing |
cable clips, staples, trunking clips |
— |
|
Impact resistance |
Low (PVC) |
— |
|
Water resistance |
Limited (no sheath) |
— |
|
UV resistance |
Poor (indoor/conduit only) |
— |
|
Flex life |
Poor (Class 1 solid, NOT for flexing) |
— |
|
Termination note |
Screw terminals, compression lugs (2.5 mm²) |
— |
6. Typical Service Applications
Fixed indoor wiring across residential, commercial and light industrial installations: auxiliary conductors in distribution boards, internal panel wiring, designated phase or control runs in lighting and socket circuits, and branch feeders where the contractor's colour schedule reserves plain green for a specific circuit function. The medium-tone jacket keeps installed wiring looking clean in service. Accepted installation methods include conduit, trunking, cable tray and embedded wall wiring. It is unsuitable for: moving or trailing machine leads, shielded instrumentation signals, outdoor UV-exposed runs, submersible or buried circuits, and high-temperature heating elements.

7. Testing & Quality Assurance Regime
Routine tests on 100% of production: DC resistance, 2000 V/5 min AC withstand, insulation resistance, conductor construction, insulation thickness, dimensional inspection, dark-print legibility against the green jacket, mass per unit length, appearance and shade uniformity, and packing. Type tests per material batch or design change: heat aging at 100 °C for 7 days, cold bend at -15 °C, insulation tensile strength and elongation, flame retardancy, insulation flexibility, and wall thickness uniformity. Every coil ships with a mill test certificate plus ROHS and REACH declarations. Green lots are visually checked for even pigment dispersion, free from pale patches or darker streaks.
The Wire Parameters
| BV 1×2.5 mm² (Green) — Full Parameter Sheet | ||||
| Single-core green PVC insulated building wire · 450/750 V · pure annealed Cu solid Class 1 · green PVC insulation · no shield, no outer jacket · GB/T 5023 / IEC 60227 | ||||
| Section | Parameter | Value | Unit | Remarks / Standard |
| 01 · Identification | ||||
| Cable type | BV (Green) | — | Single-core, green PVC insulated, pure Cu conductor | |
| Rated voltage (U0/U) | 450/750 | V | Fixed indoor wiring | |
| Number of cores | 1 | — | Single core, solid | |
| Nominal cross-section | 2.5 | mm² | Per core, Class 1 solid | |
| Conductor material | Pure annealed copper (bare) | — | Class 1 per GB/T 3956, not tinned | |
| Insulation material | PVC (green) | — | 70 °C rated, 0.8 mm wall | |
| Shield | None | — | No braid / foil on single-core wire | |
| Outer jacket | None | — | Insulation forms the outer layer | |
| Standard reference | GB/T 5023 / IEC 60227 / JB/T 8734 | — | PVC insulated fixed wiring wire | |
| 02 · Conductor | ||||
| Conductor form | Solid (single wire) | — | Class 1 | |
| Conductor diameter | 1.78 | mm | Solid wire | |
| DC resistance @ 20 °C | ≤ 7.41 | Ω/km | Maximum per GB/T 3956 (pure Cu) | |
| Conductor surface | Bare pure copper | — | Not tinned; fixed indoor use | |
| 03 · Insulation | ||||
| Insulation type | PVC (green) | — | Soft PVC, 70 °C | |
| Insulation thickness | ≈ 0.8 | mm | Nominal | |
| Finished diameter | ≈ 3.4 | mm | Insulation outer Ø | |
| Insulation resistance | ≥ 20 | MΩ·km | At 20 °C | |
| 04 · Lay-Up & Shield | ||||
| Core lay-up | Not applicable | — | Single-core wire | |
| Filler / bedding | None | — | No inner sheath on BV | |
| Shield type | None | — | Unshielded building wire | |
| Shield coverage | — | — | Not applicable | |
| 05 · Insulation Finish | ||||
| Outer surface | Smooth green PVC extrusion | — | Uniform medium-tone colour | |
| Printing | Designation / size / voltage / metre mark | — | Dark print at regular intervals | |
| Insulation colour | Green (plain) | — | Auxiliary/phase; PE = green-yellow striped only | |
| 06 · Electrical | ||||
| Rated voltage | 450/750 | V | Fixed wiring | |
| Test voltage (AC) | 2000 | V AC | 5 min routine | |
| DC resistance @ 20 °C | ≤ 7.41 | Ω/km | Per GB/T 3956 (pure Cu) | |
| Ampacity (conduit, est.) | ≈ 20–25 | A | 2.5 mm², 70 °C | |
| Ampacity (free air, est.) | Up to ≈ 32 | A | Derate for grouping / enclosure | |
| Capacitance | ≈ 150 | pF/m | At 1 kHz | |
| 07 · Thermal & Mechanical | ||||
| Max continuous conductor temp. | 70 | °C | Normal service | |
| Short-circuit temp. (≤5 s) | 160 | °C | Copper limit | |
| Min. ambient temp. | -15 | °C | Fixed installation | |
| Min. bending radius | ≥ 4 × OD ≈ 14 | mm | Fixed wiring, solid core | |
| Halogen content | Halogen-containing | — | PVC compound | |
| 08 · Flame & Environment | ||||
| Flame retardancy | IEC 60332-1 | — | Single vertical flame | |
| Oil resistance | Limited | — | PVC insulation | |
| UV resistance | Limited | — | Indoor / conduit use; keep out of long sunlight | |
| Corrosion resistance | Limited (bare Cu) | — | Dry indoor only; use tinned variant for damp/outdoor | |
| ROHS / REACH | Compliant | — | EU 2011/65/EU | |
The Wire Test Parameters
| Test Parameters — BV 1×2.5 mm² (Green) | ||||
| No. | Test Item | Test Condition / Method | Requirement | Type |
| 1 | Conductor DC resistance | GB/T 3956, 20 °C | ≤ 7.41 Ω/km | Routine |
| 2 | AC voltage withstand | 2000 V AC, 5 min | No breakdown | Routine |
| 3 | Insulation resistance | 500 V megohmmeter | ≥ 20 MΩ·km | Routine |
| 4 | Conductor construction | Visual + micrometer | Solid Ø 1.78 mm pure Cu | Routine |
| 5 | Insulation thickness | Micrometer cross-section | ≈ 0.8 mm | Routine |
| 6 | Dimensional check | Caliper | OD ≈ 3.4 mm | Routine |
| 7 | Print legibility | Visual + rubbing | Dark print legible on green | Routine |
| 8 | Mass per unit length | Weighing | ≈ 29 kg/km | Routine |
| 9 | Appearance / colour | Visual | Smooth, uniform green, no patches | Routine |
| 10 | Packing | Visual | Coil, sealed ends, labelled | Routine |
| 11 | Heat aging test | 7 days at 100 °C | Retention ≥ 70% | Type |
| 12 | Cold bend test | -15 °C, 4 h mandrel | No cracking | Type |
| 13 | Insulation tensile & elongation | Universal tester | Meets GB/T 5023 min. | Type |
| 14 | Flame retardancy | IEC 60332-1 | Self-extinguish | Type |
| 15 | Insulation flexibility | Mandrel bend at ambient | No cracking, no peeling | Type |
| 16 | Wall thickness uniformity | Micrometer at 4 points | Min. wall ≥ nominal − tolerance | Type |
Cross Section Structure

| BV 1×2.5 mm² (Green) — Cross-Section Construction Diagram (Schematic) | |||||
| Layered build-up: pure copper solid conductor (single core) → green PVC insulation · 450/750 V single-core PVC insulated building wire · auxiliary / phase identification per local schedule · no shield, no outer jacket · -15~+70 °C | |||||
| No. | Layer | Material / Construction | Nominal Thickness (mm) | Diameter (mm) | Function / Remarks |
| 1 | Conductor | Pure annealed copper, solid Class 1 — single wire Ø 1.78 mm | — | 1.78 | Fixed wiring; R ≤ 7.41 Ω/km; bare pure copper for high conductivity |
| 2 | Insulation | Green PVC compound, extruded over the solid conductor | ≈ 0.8 | ≈ 3.4 (finished) | Primary electrical insulation; 450/750 V rated; plain green auxiliary/phase ID — not green-yellow PE |
| Key Dimensions & Properties (expanded) | |||||
| Finished cable diameter | ≈ 3.4 | mm | Single-core PVC building wire (est.) | ||
| Approximate cable mass | ≈ 29 | kg/km | Pure Cu + PVC insulation | ||
| Nominal voltage rating | 450/750 | V | Fixed indoor wiring | ||
| Max continuous conductor temp. | 70 | °C | Normal service | ||
| Min. ambient / installation temp. | -15 | °C | Fixed installation | ||
| DC resistance @ 20 °C | ≤ 7.41 | Ω/km | Class 1 pure copper, GB/T 3956 | ||
| Core count × cross-section | 1 × 2.5 | mm² | Single core, solid | ||
| Shielding | None | — | Single-core wire, no braid / foil | ||
| Insulation resistance | ≥ 20 | MΩ·km | PVC at 20 °C | ||
| Test voltage (AC) | 2000 V AC / 5 min | — | Routine withstand test | ||
| Flame retardancy | IEC 60332-1 | — | Single vertical flame | ||
| Insulation colour | Green (plain, designated) | — | Auxiliary/phase; PE must be green-yellow striped | ||
| Jacket colour | — | — | BV has no outer jacket; insulation is the outer layer | ||
| Mass per 100 m | ≈ 2.9 | kg/100 m | For coil loading | ||
| Reference standard | GB/T 5023 / IEC 60227 / JB/T 8734 | — | PVC insulated fixed wiring wire | ||
| Schematic — not to exact scale. Finished Ø ≈ 3.4 mm and weight ≈ 29 kg/km from cross-referenced industry samples; solid pure copper conductor Ø 1.78 mm, 0.8 mm green PVC insulation. Pure copper (not tinned). Est. values confirmed against factory type certificate. | |||||
Construction Description
| Construction Description — BV 1×2.5 mm² (Green) | |||
| Layer-by-layer build-up narrative · 450/750 V single-core green PVC insulated building wire · GB/T 5023 / IEC 60227 · pure annealed copper solid conductor / green PVC insulation | |||
| 1. Product Identity & Ratings | |||
| BV 1×2.5 (Green) is a single-core PVC insulated building wire rated 450/750 V. The conductor is pure annealed bare copper (not tinned), selected for dependable conductivity and long-term contact in stationary wiring. One 2.5 mm² solid copper core is covered by a continuous green PVC extrusion. There is no braid shield, no inner sheath and no outer jacket. OD ≈ 3.4 mm, ≈ 29 kg/km. Max 70 °C, -15 to +70 °C. The plain green jacket marks a dedicated auxiliary or phase conductor under the project colour schedule. | |||
| 2. Pure Copper Conductor | |||
| The 2.5 mm² conductor is a single solid annealed copper wire, Class 1, diameter 1.78 mm. Solid construction keeps the wire dimensionally stable and easy to seat in terminals and connectors. DC resistance ≤ 7.41 Ω/km at 20 °C per GB/T 3956. Pure bare copper provides the highest conductivity available for fixed installation; for damp or outdoor locations a tinned or insulated variant should be considered separately. | |||
| 3. Green PVC Insulation | |||
| A 0.8 mm green PVC compound is extruded continuously over the solid copper core, forming the only insulating and outer layer. The insulation provides the primary electrical barrier for 450/750 V circuits, with insulation resistance ≥ 20 MΩ·km at 20 °C. The medium green surface retains a tidy look in service and masks light dust and minor marks; dark lettering is printed on the jacket for legibility. | |||
| 4. Lay-Up & Colour Coding | |||
| As a single-core wire there is no stranding of multiple cores, fillers or bedding. Colour allocation varies by national practice; plain green typically serves as an auxiliary or phase conductor in panel wiring. Crucially, plain green is never a protective earth conductor: PE wiring must use green-yellow striped insulation, reserved exclusively for earthing. | |||
| 5. Surface Marking & Application Range | |||
| The green insulation surface is printed at regular intervals with the designation BV, cross-section, voltage rating, manufacturer and metre mark; dark print remains legible against the jacket. The wire is designed for fixed installation inside conduits, trunking and panel enclosures: lighting circuits, socket outlets, panel internal wiring and branch circuits. It is not a flexible appliance cable, not a shielded signal cable and not a submersible or direct-burial wire. |
8. Factory Advantages
Pure annealed solid copper gives stable conductivity and low resistance over long fixed runs. Continuous green PVC extrusion produces a smooth, consistent wall with a uniform medium shade and predictable diameter, without blisters or pinholes. Green is a standard stocked colour, which shortens lead times on general wiring orders. The jacket takes a dark, legible print that stays readable after installation. The solid core seats squarely in terminals, lowering the risk of loose joints. Every coil undergoes 100% routine electrical QA. Cut-to-length coils with sealed ends cut site waste. At ≈ 29 kg/km the wire stays light to pull through conduit. Full traceability is supported by MTC and certification packages for building-wiring tenders.

9. Packaging, Storage & Logistics
Cut to requested length on export-grade coils; both ends sealed against moisture. Coils are wrapped in waterproof film and cardboard, labelled with BV designation, cross-section, green colour, length, weight, production date and reel number. Common lengths 100/200/500/1000 m; custom cuts available. Store indoors at -10 to +40 °C, below 75% RH, away from sunlight, solvents and chemical vapours. Keep the film on until installation to preserve the jacket surface; green pigment is reasonably stable indoors, but prolonged sun exposure and solvent contact can still dull or stain it. Shipping terms FOB Shanghai/Nanjing/Qingdao; CIF and DAP on request. Sample lead 5–7 days, bulk 15–25 days. Different colours are packed and labelled in separate lots.

10. Procurement Specification
Order wording: "BV 1×2.5 pure copper, plain green insulation". Ask for the routine 2000 V AC withstand record and the DC resistance certificate for the specific green lot. Note this is a bare pure copper fixed-wiring variant for dry indoor use; for damp or outdoor service, select a tinned or appropriate insulated variant instead. Before ordering, confirm with the project colour schedule whether plain green is the assigned auxiliary or phase in that region — and never substitute it for the green-yellow striped protective earth conductor. State any regional certification requirements (CE, etc.) at order time. Terms: 30% T/T deposit, balance against B/L copy. Documents: MTC, ROHS/REACH, COO, commercial invoice, packing list.
11. Cable Industry FAQ
Q1: What does "BV" designate? B denotes copper conductor, V denotes PVC insulation; BV is the standard Chinese code for a single-core PVC insulated fixed-wiring wire, corresponding to plain building wire under IEC 60227 practice.
Q2: Is plain green the protective earth wire? No. Protective earthing uses green-yellow striped insulation only. Plain green is an auxiliary or phase conductor; using it as PE violates wiring safety rules.
Q3: Why specify a green jacket? Green provides a dedicated, stable circuit identity in panel and raceway wiring, matching the contractor's colour schedule; its medium tone also keeps the installed run looking tidy.
Q4: Solid or stranded conductor? Solid Class 1 pure annealed copper wire, Ø 1.78 mm; DC resistance ≤ 7.41 Ω/km at 20 °C.
Q5: What is the rated voltage? 450/750 V, intended for low-voltage fixed indoor lighting, socket and panel circuits.
Q6: How much current does 2.5 mm² carry? ≈ 20–25 A in conduit, up to ≈ 32 A in free air, derated for grouping and enclosure; match against local wiring rules and the upstream protective device.
Q7: Why pure copper rather than tinned? Bare pure copper offers the highest conductivity for dry indoor fixed contacts; tinned copper is normally reserved for damp or exposed locations where corrosion could attack bare copper.
Q8: Does green discolour in storage? Green pigment is reasonably stable indoors, but keep coils wrapped and away from direct sun and solvents; prolonged exposure can dull the shade or leave stains.
Q9: Is there any shielding on BV? None — BV is an unshielded single-core building wire. EMI-sensitive signal circuits call for a shielded RVVP multiconductor cable instead.
Q10: What certification ships with the coil? Routine 2000 V AC test record, DC resistance certificate and MTC, with shade uniformity noted on the appearance inspection.
Q11: When should BVR be chosen over BV? For frequent flexing, vibrating equipment connections or tight panel gaps, choose the stranded BVR variant; BV solid is best suited to straight, stationary fixed runs.