"1kv 3 cores cable"
- 60 Items Found
Building Power Distribution 2 Core Power Cable Braided Flex Oxygen Free Copper
ZR-YJV 2*10mm² Flame Retardant 2 Core Power Cable,0.6/1kV Oxygen-Free Copper,XLPE Insulation PVC Sheath for Building Power Distribution Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Outer Sheathed. ZR-YJV 2×10 mm² — Technical Description 1. Product Class. The ZR-YJV 2×10 is a two-core flame...
25 Mm2 Fire Resistant Cable 4x25mm2+1x16mm2 Mineral Insulated Copper
0.6/1kV Mineral Insulated Cable BTTRZ 4x25mm²+1x16mm² Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV Rated ...
4x70mm2+1x35mm2 Fire Resistant Cable 1KV 1.2KV Bare Copper Mineral Insulated Cable
Heavy Duty Fire Cable BTTRZ 4x70mm²+1x35mm² Mineral Insulated 0.6/1kV Cable Designation & Meaning Code Meaning BTTRZ Flexible mineral-insulated copper-sheathed fire-resistant cable 4×70 mm² Four cores of 70 mm² copper conductor (3 phase + 1 neutral) +1×35 mm² One core of 35 mm² copper conductor ...
2x16mm2 2 Core Fiber Optic Cable IEC Full Gauge Copper PVC Sheath For Power Engineering
ZR-YJV 2*16mm² Flame Retardant 2 Core Cable,0.6/1kV IEC Standard Full Gauge Copper,XLPE Anti-Aging PVC Sheath for Power Engineering Cable Designation & Meaning Code Meaning ZC Flame retardant C — IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 2×16 mm² Two ...
2 X 50mm2 2 Core Shielded Cable Pvc Jacket Wire For Construction Power
ZR-YJV 2*50mm² Flame Retardant 2 Core Cable, 0.6/1kV Stranded Copper, XLPE Insulation PVC Jacket for Construction Power Cable Designation & Meaning Code Meaning ZC Flame retardant C — IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 2×50 mm² Two cores, 50 mm² ...
ZR-YJV 1*185mm² Flame Retardant Copper Cable,0.6/1kV XLPE Insulation PVC Sheath for Building Wiring
ZR-YJV 1*185mm² Flame Retardant Copper Cable,0.6/1kV XLPE Insulation PVC Sheath for Building Wiring Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Outer Sheathed. ZR-YJV 1×185 mm² — Specification Sheet 1. General Description. The ZR-YJV 1×185 is a single-core, flame-retardant cable of CU/XLPE...
ZR-YJV 1*240mm² Fire Retardant Single Conductor Cable, 0.6/1kV Pure Copper, XLPE PVC Sheath for Indoor Power Wiring
ZR-YJV 1*240mm² Fire Retardant Single Conductor Cable, 0.6/1kV Pure Copper, XLPE PVC Sheath for Indoor Power Wiring Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Outer Sheathed ZR-YJV 1×240 mm² — Product Briefing 1. What It Is. The ZR-YJV 1×240 is the heavy feeder class of the flame...
XLPE Insulated 4 Core Shielded Cable Copper Power ZR-YJV 4x300mm2 For Power Transmission
XLPE Insulated Flame Retardant Copper Cable ZR-YJV 4*300mm² for Power Transmission Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — ...
OEM Copper Xlpe Cable 4 Core Heat Resistant Flex 3×50mm2+1×25mm2 For Heavy Duty
Flame Retardant Copper Conductor ZR-YJV 3×50mm²+1×25mm² for Heavy-Duty Three Phase Supply Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 3×50 mm² + 1×25 mm² Three phase cores of 50 mm² + one neutral ...