ZR-YJV 1*185mm² Flame Retardant Copper Cable,0.6/1kV XLPE Insulation PVC Sheath for Building Wiring

ZR-YJV 1*185mm² Flame Retardant Copper Cable,0.6/1kV XLPE Insulation PVC Sheath for Building Wiring

Basic Properties

country of origin
China
brand name
TD
certificate
CE/ISO/CCC
product model
ZR-YJV 1*185mm²

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
10000 meters per month

Product Summary

ZR-YJV 1*185mm² Flame Retardant Copper Cable,0.6/1kV XLPE Insulation PVC Sheath for Building Wiring Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Outer Sheathed. ZR-YJV 1×185 mm² — Specification Sheet 1. General Description. The ZR-YJV 1×185 is a single-core, flame-retardant cable of CU/XLPE...

Product Details

Conductor:
Bare Annealed Copper, Class 2 Stranded Circular, 37×∅2.52 Mm​ (typical), Conductor Ø ≈ 17.6 Mm
Conductor nominal area:
185 Mm²
Conductor construction:
Class 2, 37×∅2.52 Mm​ Min. 37 Wires Per GB/T 3956 (>95 Mm²)
Conductor diameter (approx.):
17.6 Mm
Insulation:
XLPE Compound, Extruded
Insulation nominal thickness:
1.2mm
Diameter over insulation (approx.):
20.0 Mm (17.6 + 2×1.2)
Filler / binder​:
Flame-retardant (FR) Non-hygroscopic Tape / PP Mesh​
Outer sheath:
Flame-retardant PVC Compound (ZR Grade)​ — Contains Halogen, Not Low-smoke
Sheath nominal thickness:
1.4mm
Overall cable diameter:
25.5 – 26.5 Mm​,PVC Density; Use 26.0 Mm For Design
Approx. weight:
1,550 – 1,650 Kg/km​,PVC Heavier Than PO; Use ≈ 1,600 Kg/km
Long-term service temperature:
90 °C
Short-circuit temperature (≤5 s):
250 °C
Emergency overload:
105–130 °C (limited Duration)
Routine test:
3.5 KV AC / 5 Min; Type Test 4.0 KV
Volume resistivity @90 °C:
≥ 10¹² Ω·cm

Product Description

ZR-YJV 1*185mm² Flame Retardant Copper Cable,0.6/1kV XLPE Insulation PVC Sheath for Building Wiring


Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Outer Sheathed.

ZR-YJV 1×185 mm² — Specification Sheet 

1. General Description. The ZR-YJV 1×185 is a single-core, flame-retardant cable of CU/XLPE/PVC construction rated 0.6/1 kV (Um = 1.2 kV), 50 Hz, intended for heavy low-voltage distribution. It conforms to GB/T 12706.1 / IEC 60502-1; core sizing to GB/T 3956 / IEC 60228; flame behaviour to GB/T 19666 / GB/T 18380 (default class ZC).


ZR-YJV 1*185mm² Flame Retardant Copper Cable,0.6/1kV XLPE Insulation PVC Sheath for Building Wiring


2. Layer-by-Layer Build. From the centre outward:

Layer Material & arrangement Wall Diameter
Core Annealed copper, Class 2, 37 × 2.52 mm (37/2.52, 1+6+12+18), 185 mm² — ≈ 15.3 mm (compacted; up to ≈ 17 mm round-lay)
Dielectric Cross-linked polyethylene 1.6 mm ≈ 18.5 mm over insulation
Jacket Flame-retarded PVC, ST2, black 2.0 mm ≈ 22.5 mm overall

Weight ≈ 1944 kg/km (the copper alone ≈ 1645 kg/km); OD 22.5–23 mm (some makers quote up to 25 mm with tolerance).


3. Electrical Ratings. DC resistance ≤ 0.0991 Ω/km @ 20 °C; routine AC withstand 3.5 kV / 5 min; XLPE volume resistivity ≥ 1×10¹² Ω·cm; insulation resistance typically ≥ 36.7 MΩ·km; capacitance ≤ 0.45 μF/km. Reference ampacity ≈ 530 A in air (30 °C, single core) and ≈ 480 A buried; final ratings follow GB/T 16895 / IEC 60364 derating.


Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

Uₘ = 1.2 kV

Test voltage AC (5 min)

3.5 kV​

Routine

Type-test voltage

4.0 kV

IEC 60502

DC resistance @20 °C (Class 2 Cu)​

≤ 0.0991 Ω/km​

GB/T 3956 / IEC 60228 max

AC resistance @90 °C (est.)

≈ 0.129 Ω/km

copper temp. coefficient

Current rating in air (30–40 °C, single circuit, single-core)

≈ 505 – 520 A​

PVC sheath; design ≈ 505 A​

Direct buried (20 °C, soil 1.0 K·m/W, 0.7 m)

≈ 460 – 475 A​

design ≈ 460 A​

Short-circuit current (1 s adiabatic, Cu, 250 °C)

≈ 21.39 kA

reference

Frequency

50/60 Hz AC (DC usable)

—


4. Thermal & Mechanical Limits. Continuous conductor 90 °C; short-circuit 250 °C (≤ 5 s); ambient −20 to +45 °C; laying ≥ 0 °C; minimum bend radius 20 × OD for single-core work.


ZR-YJV 1×185 mm² Flame-Retardant Copper-Conductor XLPE-Insulated PVC-Sheathed Power Cable — Product Parameters (0.6/1 kV)
Construction: CU / XLPE / PVC  •  Standards: GB/T 12706.1, IEC 60502-1 (cable), GB/T 3956 (conductor), GB/T 19666 & GB/T 18380 (flame retardance)  •  Nominal values for reference — confirm against factory test certificate
No. Category Parameter Value Unit Notes / Standard Reference
A. Product Identification
1 Identification Product name Flame-retardant copper-conductor XLPE-insulated PVC-sheathed power cable — Designation ZR-YJV; "ZR" = flame-retardant (halogen-containing)
2 Identification Model designation ZR-YJV 1×185 — Cu / XLPE / PVC
3 Identification Design standards GB/T 12706.1; IEC 60502-1 — Conductor: GB/T 3956 / IEC 60228; flame retardance: GB/T 19666, GB/T 18380; safety: CCC / production licence
4 Identification Rated voltage U0/U 0.6/1 kV Max system voltage Um = 1.2 kV
5 Identification Rated frequency 50 Hz AC power distribution
6 Identification Number of cores 1 — Single-core cable
7 Identification Nominal cross-sectional area 185 mm² Nominal conductor cross-section per GB/T 3956
B. Cable Construction (from conductor to outer sheath)
8 Conductor Material Plain annealed copper (Cu) — High-conductivity electrolytic / oxygen-free copper
9 Conductor Conductor class Class 1 or Class 2 (typical: Class 2, stranded) — GB/T 3956 / IEC 60228
10 Conductor Typical stranding construction 37 wires × 2.52 mm (37/2.52, lay-up 1+6+12+18) — Class 2 round stranded; nominal section ≈ 185 mm²
11 Conductor Conductor diameter ≈ 15.3 mm ≈ 15.3 mm compact (15.3–17.0 mm across stranding practice)
12 Conductor Max. DC resistance of conductor at 20 °C 0.0991 Ω/km GB/T 3956, Class 2 copper; acceptance criterion for 185 mm²
13 Insulation Material Cross-linked polyethylene (XLPE) — Thermally cross-linked; natural/transparent colour
14 Insulation Nominal insulation thickness 1.6 mm GB/T 12706.1 / IEC 60502-1 (0.6/1 kV, 185 mm²)
15 Insulation Diameter over insulation ≈ 18.5 mm ≈ 15.3 + 2 × 1.6 (calculated, compact conductor)
16 Sheath Material Flame-retardant polyvinyl chloride (PVC, ST2 type) — Colour: black (or as ordered)
17 Sheath Nominal sheath thickness 2.0 mm GB/T 12706.1 / IEC 60502-1 (cabhr & Hongqi tables)
18 Dimensions Approx. overall diameter 22.5 mm ≈ 22.5 mm (22.5–23 mm; some makers list up to 25 mm incl. tolerance)
19 Dimensions Approx. cable weight ≈ 1944 kg/km cabhr / Hongqi / Lvbao agree at 1944 kg/km (copper core alone ≈ 1645 kg/km)
C. Electrical Performance
20 Electrical Max. DC conductor resistance at 20 °C 0.0991 Ω/km GB/T 3956; routine measurement
21 Electrical Power-frequency withstand voltage (routine test) 3.5 kV / 5 min, no breakdown — AC 50 Hz; per GB/T 12706.1 / IEC 60502-1
22 Electrical Insulation resistance (finished cable, 20 °C) ≥ 36.7 MΩ·km Typical finished-cable reference for 0.6/1 kV XLPE cables; varies with geometry and manufacturer test method
23 Electrical XLPE volume resistivity at 20 °C ≥ 1 × 10¹² Ω·cm Material-level requirement (manufacturer reference)
24 Electrical Capacitance (single-core, approx.) ≤ 0.45 μF/km Manufacturer reference value
25 Electrical Reference ampacity — in air, 30 °C, single core ≈ 530 A cabhr table (530 A); depends on laying, grouping, ambient — apply correction factors per GB/T 16895 / IEC 60364
26 Electrical Reference ampacity — direct burial, 25 °C ≈ 480 A cabhr table; depends on soil thermal resistivity and depth
D. Thermal Performance
27 Thermal Max. continuous conductor temperature 90 °C XLPE insulation temperature class
28 Thermal Max. conductor temperature under short-circuit (≤ 5 s) 250 °C Per GB/T 12706.1 / IEC 60502-1
29 Thermal Ambient service temperature range -20 to +45 °C Per Qifan datasheet family; check project specification
30 Thermal Min. installation (laying) temperature 0 °C Pre-heat the cable if ambient is below 0 °C
E. Flame Retardance (ZR)
31 Flame retardance Flame-retardant class ZC (class C) by default for "ZR" — GB/T 19666; ZA / ZB available on request; halogen-containing PVC (not LSZH)
32 Flame retardance Single-cable vertical flame-spread test Pass — GB/T 18380.12
33 Flame retardance Bunched flame-spread test (class C) Char extent ≤ 2.5 m above burner bottom edge — GB/T 18380.35: non-metallic volume ≥ 1.5 L/m; flame application 20 min
34 Flame retardance Halogen content Halogen-containing (PVC) — For low-smoke, zero-halogen requirement select WDZ-YJY (LSZH) type
F. Installation
35 Installation Min. bending radius — single-core cable 20 × OD — Qifan & Huaneng datasheets; OD = actual cable diameter
36 Installation Laying methods Conduit, tray, cable trench, tunnel, duct, supported/suspended aerial — Also direct burial with mechanical protection where permitted
37 Installation Site withstand test after installation DC 4U0 = 2.4 kV, 15 min (recommended) — Per utility procurement standard Q/GDW 13244.1-2018; practice may vary by project
G. Packing & Delivery
38 Packing Standard delivery length 100 m per coil/drum (or as ordered) — Typical industry practice; custom lengths available
39 Packing Cable marking Model, rated voltage, manufacturer, year of manufacture, sequential length marks — Per GB/T 6995 / project specification
40 Packing Packing form Wooden drum / coil / export packing — As per customer requirement


5. Fire Performance. Passes GB/T 18380.12 (single vertical burn) and class-C bunched burn GB/T 18380.35 (char ≤ 2.5 m; ≥ 1.5 L/m non-metallic) → class ZC per GB/T 19666. PVC = halogen-bearing; use WDZ-YJY for LSZH projects.


ZR-YJV 1*185mm² Flame Retardant Copper Cable,0.6/1kV XLPE Insulation PVC Sheath for Building Wiring


6. Factory & Site Testing. Routine: resistance, 3.5 kV/5 min, dimensions (ins. ≥ 1.6 mm, sheath ≥ 2.0 mm). Sample: XLPE hot-set (200 ± 3 °C / 15 min / 0.2 MPa — load elongation ≤ 175 %, permanent ≤ 15 %). Type: flame + bending. Site: DC 4U0 = 2.4 kV / 15 min (Q/GDW 13244.1-2018 practice).


ZR-YJV 1×185 mm² — Test / Verification Parameters (per GB/T 12706.1 & IEC 60502-1)
Test Stage Test Item Method / Standard Requirement / Acceptance Criterion Notes
Routine test Conductor DC resistance measurement GB/T 3956 (IEC 60228) ≤ 0.0991 Ω/km at 20 °C Measured on every production length
Routine test Power-frequency withstand voltage GB/T 12706.1 / IEC 60502-1 3.5 kV AC, 5 min, no breakdown Applied between conductor and water/earth; 50 Hz
Routine test Construction check — insulation & sheath thickness, outer diameter GB/T 2951 Within GB/T 12706.1 tolerances Insulation ≥ 1.6 mm nominal; sheath ≥ 2.0 mm nominal
Sample test Hot set (thermal elongation) test — XLPE insulation GB/T 12706.1 §16.3.13 / GB/T 2951.11 200 ± 3 °C, 15 min, stress 0.2 MPa: elongation under load ≤ 175 %; permanent elongation after cooling ≤ 15 % Verifies degree of cross-linking
Sample test Conductor construction & diameter check GB/T 3956 Class 2; 37 × 2.52 mm; Ø ≈ 15.3 mm Sampled per batch
Type test Single-cable vertical flame-spread test (flame retardance) GB/T 18380.12 No flame spread; charring does not reach top reference point ZR / ZC flame-retardant property
Type test Bunched flame-spread test, class C GB/T 18380.35 Char extent ≤ 2.5 m above burner bottom edge; flame application 20 min; non-metallic volume ≥ 1.5 L/m Class ZC per GB/T 19666
Type test Bending test (mechanical) GB/T 12706.1 Bend around specified mandrel without insulation/sheath damage Mandrel diameter related to cable OD
Post-installation DC withstand test after installation Q/GDW 13244.1-2018 (recommended practice) 4U0 = 2.4 kV DC, 15 min, no breakdown For new installations; verify project specification
Optional Insulation resistance measurement at 20 °C Manufacturer test method ≥ 36.7 MΩ·km (typical finished-cable value) Not a routine item in GB/T 12706.1; confirm with factory
Optional XLPE volume resistivity at 20 °C Manufacturer / material test ≥ 1 × 10¹² Ω·cm Material-level reference


7.Cross Section Structure


ZR-YJV 1*185mm² Flame Retardant Copper Cable,0.6/1kV XLPE Insulation PVC Sheath for Building Wiring


ZR-YJV 1×185 mm² — Cable Cross-Section Structure (Schematic)
Layers from conductor to outer sheath · nominal values per GB/T 12706.1 / IEC 60502-1 · not to exact scale






No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor (Cu) Annealed copper, Class 2 stranded — 37 × 2.52 mm (37/2.52, 1+6+12+18), nominal 185 mm² — ≈ 15.3 (Ø) Current-carrying element; max DC resistance ≤ 0.0991 Ω/km @ 20 °C
2 Insulation (XLPE) Cross-linked polyethylene 1.6 ≈ 18.5 (Ø over insulation) Dielectric barrier; rated 90 °C continuous; withstands 3.5 kV / 5 min
3 Outer sheath (PVC) Flame-retardant PVC, ST2 type, black 2 ≈ 22.5 (Ø overall) Mechanical & moisture protection; flame retardance ZC (ZR) per GB/T 19666
Key Dimensions & Properties
Overall diameter 22.5 mm 22.5–23 mm (up to 25 mm incl. tolerance); cabhr 22.5; Hongqi 23

Approx. cable weight ≈ 1944 kg/km cabhr / Hongqi / Lvbao agree; Cu core alone ≈ 1645 kg/km

Rated voltage 0.6/1 kV AC 50 Hz; max system voltage Um = 1.2 kV

Max conductor temperature 90 / 250 °C Continuous / short-circuit (≤ 5 s)

Min. bending radius (single-core) 20 × OD — OD = actual cable diameter

Flame-retardant class ZC (ZR) — GB/T 19666


Product Structure Introduction — ZR-YJV 1×185 mm² (English)
Layered construction description, from conductor to outer sheath · per GB/T 12706.1 & IEC 60502-1 · CU / XLPE / PVC · 0.6/1 kV




1. Product Outline
The ZR-YJV 1×185 is a heavy-duty single-conductor power cable for 0.6/1 kV AC circuits. Its build order is simple: a stranded copper core, an extruded XLPE dielectric and a fire-retarding PVC sheath. Conformance is claimed to GB/T 12706.1 / IEC 60502-1 for the cable itself, GB/T 3956 / IEC 60228 for the core, and GB/T 19666 plus GB/T 18380 for the flame-retardant behaviour. The default “ZR” level is ZC.
Typical cross-section: 22.5 mm across and roughly 1944 kg/km in mass; drums are standardised at 100 m. It is a fixed-installation product, not intended for continuous flexing.




2. Layer 1 — The Copper Conductor
Annealed copper is stranded to Class 2 with thirty-seven 2.52 mm wires (37/2.52, arranged 1+6+12+18) to reach 185 mm². The fine-wire bundle improves flexibility and makes bending around trays easier, while the DC resistance at 20 °C stays at or below 0.0991 Ω/km. Compaction trims the core to about 15.3 mm; a non-compacted build can measure up to roughly 17 mm.




3. Layer 2 — The XLPE Insulation
A 1.6 mm coat of cross-linked polyethylene surrounds the core, lifting the diameter over insulation to about 18.5 mm. Because the material is cross-linked, it no longer melts at thermoplastic temperatures: the cable runs continuously at 90 °C and tolerates 250 °C for five seconds under fault. The dielectric layer must also pass 3.5 kV AC for 5 minutes on every production length, supported by a volume resistivity of at least 1×10¹² Ω·cm.




4. Layer 3 — The PVC Outer Sheath
The finish is a 2.0 mm black PVC sheath made with flame-retardant (ST2) compound, taking the overall diameter to ≈ 22.5 mm. It shields the dielectric from water, scrapes and impacts and is the source of the ZC rating — verified by the single vertical burn (GB/T 18380.12) and the category-C bunched burn (GB/T 18380.35, char cap 2.5 m). As with all PVC jackets, halogen is present; WDZ-YJY is the zero-halogen alternative.




5. Practical Notes for Users
• Minimum bend radius 20 × OD for single-core handling.  • Site DC test 4U0 = 2.4 kV / 15 min before commissioning.  • Ambient limit −20 to +45 °C; warm the drum below 0 °C.  • De-rate ampacity for bundling and soil conditions.  • Match glands, lugs and joint kits to the actual core diameter after confirming the factory certificate.


8. Installation Care Points. Unreel without twisting; keep bends ≥ 20 × OD; avoid dragging the sheath over sharp metal; protect from UV outdoors; verify insulation before energising; size lugs and glands against the actual core diameter.


9. Intended Usage. Main feeders, large motor circuits, transformer tails, switchboard risers and industrial sub-mains at 0.6/1 kV — trays, conduits, trenches, tunnels and ducts; indoor or sheltered outdoor.


ZR-YJV 1*185mm² Flame Retardant Copper Cable,0.6/1kV XLPE Insulation PVC Sheath for Building Wiring


10. Supply & Order Data. Standard 100 m per drum/coil, standard marking. Order as ZR-YJV 0.6/1 kV 1×185 + length + drum type. Confirm all figures with the factory certificate before installation.


ZR-YJV 1*185mm² Flame Retardant Copper Cable,0.6/1kV XLPE Insulation PVC Sheath for Building Wiring


ZR-YJV 1*185mm² Flame Retardant Copper Cable,0.6/1kV XLPE Insulation PVC Sheath for Building Wiring