"1 electrical building wires pvc or lszh low smoke zero halogen"
- 70 Items Found
ZR-YJV 1*185mm² Flame Retardant Copper Cable,0.6/1kV XLPE Insulation PVC Sheath for Building Wiring
ZR-YJV 1*185mm² Flame Retardant Copper Cable,0.6/1kV XLPE Insulation PVC Sheath for Building Wiring Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Outer Sheathed. ZR-YJV 1×185 mm² — Specification Sheet 1. General Description. The ZR-YJV 1×185 is a single-core, flame-retardant cable of CU/XLPE...
Large Fire Rated Wire 4x95mm2+1x50mm2 Mineral Insulated Heating Cable
Large Fire Cable BTTRZ 4x95mm²+1x50mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ Flexible mineral-insulated copper-sheathed fire-resistant cable 4×95 mm² Four cores of 95 mm² copper conductor (3 phase + 1 neutral) +1×50 mm² One core of 50 mm² copper ...
ZR-YJV 1*240mm² Fire Retardant Single Conductor Cable, 0.6/1kV Pure Copper, XLPE PVC Sheath for Indoor Power Wiring
ZR-YJV 1*240mm² Fire Retardant Single Conductor Cable, 0.6/1kV Pure Copper, XLPE PVC Sheath for Indoor Power Wiring Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Outer Sheathed ZR-YJV 1×240 mm² — Product Briefing 1. What It Is. The ZR-YJV 1×240 is the heavy feeder class of the flame...
ZR-YJV 1*50mm² Flame Retardant Cable, 0.6/1kV Pure Copper XLPE Insulation PVC Sheath for Power Wiring
ZR-YJV 1*50mm² Flame Retardant Cable, 0.6/1kV Pure Copper XLPE Insulation PVC Sheath for Power Wiring Code Mean:ZR-Flame Retardant, YJ-XLPE Insulation, V-PVC Outer Sheathed. ZR-YJV 1×50 mm² — Detailed Product Introduction ZR-YJV 1×50 is a flame-retardant, copper-conductor, XLPE-insulated, PVC...
1.0mm2 Solid Copper Conductor Annealed 18 Awg Bare Copper Wire
1.0mm2 Solid Copper Conductor Annealed 18 Awg Bare Copper Wire BV 1.0 mm² / 18 AWG — Technical Specification Category Parameter Value / Description Product Identity Model Number BV (equivalent to 60227 IEC 01 / IEC 05) Product Name Copper Conductor PVC Insulated Single-Core Building Wire Standards ...
0.75mm2 RVV 3 Core Flexible Cable Appliance Power Cord Stranded Ground Wire
Grounding Flexible Control Cable 3 Core 0.75mm² RVV for Appliance Power Cord Cable Designation & Meaning Code Meaning RVV R = Flexible copper conductor (Class 5), V = PVC insulation, V = PVC sheath 300/500 V Rated voltage U₀/U = 300/500 V; Uₘ = 500 V 3×0.75 mm² Three flexible cores, each 0.75 mm² ...
Equipment Grounding 3 Core Flexible Cable 3x1.0mm2 Pvc Insulated Multi Strand Wire
Equipment Grounding Cord RVV 3x1.0mm² PVC Stranded Copper Flexible Cable Designation & Meaning Code Meaning RVV R = Flexible copper conductor (Class 5), V = PVC insulation, V = PVC sheath 300/500 V Rated voltage U₀/U = 300/500 V; Uₘ = 500 V 3×1.0 mm² Three flexible cores, each 1.0 mm² copper ...
Access Control 5 Core Flexible Cable RVV 5x1.0mm2 PVC Stranded Copper Flexible
Access Control Cable RVV 5x1.0mm² PVC Stranded Copper Flexible Cable Designation & Meaning Code Meaning RVV R = Flexible copper conductor (Class 5), V = PVC insulation, V = PVC sheath 300/500 V Rated voltage U₀/U = 300/500 V; Uₘ = 500 V 5×1.0 mm² Five flexible cores, each 1.0 mm² copper conductor ...
Industrial Equipment 5 Core Flexible Cable RVV 5x2.5mm2 PVC Stranded Copper
Industrial Equipment Cable RVV 5x2.5mm² PVC Stranded Copper Flexible Cable Designation & Meaning Code Meaning RVV R = Flexible copper conductor (Class 5), V = PVC insulation, V = PVC sheath 300/500 V Rated voltage U₀/U = 300/500 V; Uₘ = 500 V 5×2.5 mm² Five flexible cores, each 2.5 mm² copper ...