1.0mm2 Solid Copper Conductor Annealed 18 Awg Bare Copper Wire

Basic Properties

country of origin
China
brand name
TD
certificate
CE
product model
BV-1.0mm²

Trading Properties

moq
100 meters
unit price
USD 0.13-0.16/Meter
payment method
T/T,L/C
supply capacity
100000 rolls per month

Product Summary

BV 1.0 mm² / 18 AWG — Technical Specification Category Parameter Value / Description Product Identity​ Model Number BV (equivalent to 60227 IEC 01 / IEC 05) Product Name Copper Conductor PVC Insulated Single-Core Building Wire Standards Compliance GB/T 5023.3-2008, JB/T 8734.2-2016 Certification CCC ...

Product Details

Highlight:

annealed 18 awg bare copper wire

,

1.0mm2 copper wire solid

,

1.0mm2 18 awg bare copper wire

Copper Conductor:
99.99% Oxygen-free Copper
Insulated:
PVC
Specification:
1.0mm²/18 AWG
Voltage:
400V-750V
Color:
Yellow
Package:
100 Meters Per Roll
Certification:
CE/ISO
Rated Temperature:
0℃-70℃
Cross Section:
1.0mm²
Model:
Building Wire

Product Description

BV 1.0 mm² / 18 AWG — Technical Specification

 

Category

Parameter

Value / Description

Product Identity​

Model Number

BV (equivalent to 60227 IEC 01 / IEC 05)

 

Product Name

Copper Conductor PVC Insulated Single-Core Building Wire

 

Standards Compliance

GB/T 5023.3-2008, JB/T 8734.2-2016

 

Certification

CCC (China Compulsory Certification)

 

Brand / Origin

TD / Anhui, China

Ratings​

Rated Voltage (U₀/U)

450/750 V

 

Temperature Rating

70 °C maximum continuous operating temperature

 

Minimum Installation Temp.

0 °C (recommended; some compounds allow −15 °C)

 

Short-Circuit Temp. (max 5s)

160 °C

Conductor​

Nominal Cross-Section

1.0 mm²

 

AWG Equivalent

18 AWG (approx. 0.823 mm² — not a 1:1 match)

 

Conductor Material

Annealed Copper (Class 1 or Class 2)

 

Conductor Type

Solid (Class 1) — or 7-strand flexible (Class 2) on request

 

Conductor Diameter (solid)

1.13 mm (nominal)

 

20 °C DC Resistance (max)

≤ 18.1 Ω/km (Class 1 solid)

Insulation​

Insulation Material

PVC (Polyvinyl Chloride), Type V-75 or V-70

 

Insulation Thickness (nominal)

0.6 mm

 

Insulation Color Options

Red, Black, Blue, Yellow/Green, White, Brown, Grey, Orange

Dimensions​

Average Overall Diameter (max)

2.8 mm

 

Approx. Weight

~13–15 kg/km

Electrical Performance​

Withstand Voltage Test

2000 V AC, 5 min, no breakdown

 

Insulation Resistance (70 °C, min)

≥ 0.010 MΩ·km

Current-Carrying Capacity​

In Free Air (single cable, 30 °C ambient)

~14–15 A

 

In Conduit / Enclosed (30 °C ambient)

~11 A

 

UL/NEC 18 AWG Reference (THHN/THWN-2)

14 A @ 60 °C / 15 A @ 75 °C (for comparison only)

Mechanical & Safety​

Flame Retardant Grade

Passes GB/T 18380.1 (single vertical)

 

IP Level

IP20 (bare wire — protection depends on conduit/trunking)

 

Bending Radius (min)

≥ 4 × overall diameter (~11 mm)

 

Smoke & Toxicity

Standard PVC — not low-smoke, not halogen-free

Application​

Primary Use

Indoor fixed wiring, lighting circuits, socket circuits, control panels

 

Typical Installation

Conduit, trunking, behind drywall, switchgear internal wiring

 

Suitable Environments

Residential, commercial, light industrial (dry or damp, not wet)

 

Not Suitable For

Direct burial, outdoor exposure, fire-rated emergency circuits

Cross-Reference​

If Fire-Resistant Needed

Use NH-BV​ (fire-resistant PVC)

 

If LSZH Needed

Use WDZ-BYJ​ or WDZBN-BYJ​ (XLPE, halogen-free)

 

If Flexible Needed

Use BVR​ 1.0 mm² (Class 5 stranded)

 

1.0mm2 Solid Copper Conductor Annealed 18 Awg Bare Copper Wire

 

Performance Highlights

Electrical Performance

  • Rated Voltage 450/750 V​ — Suitable for 220/380 V single-phase and three-phase distribution systems, as well as low-voltage control and signaling circuits.

  • Low Conductor Resistance​ — Maximum DC resistance at 20 °C of ≤ 18.1 Ω/km, ensuring minimal voltage drop and efficient power transmission over typical building run lengths.

  • Excellent Dielectric Strength​ — Withstands 2000 V AC for 5 minutes​ without breakdown, providing a robust safety margin above normal operating voltage.

  • Stable Insulation Resistance​ — Maintains a minimum insulation resistance of ≥ 0.010 MΩ·km at 70 °C, preventing leakage current even under sustained load conditions.

1.0mm2 Solid Copper Conductor Annealed 18 Awg Bare Copper Wire

Thermal & Current-Carrying Capability

  • 70 °C Continuous Operating Temperature​ — The PVC insulation is formulated for long-term thermal stability at 70 °C ambient-rated service, with a short-circuit withstand capability of up to 160 °C for 5 seconds.

  • Reliable Ampacity​ — Delivers approximately 14–15 A in free air​ and ~11 A when installed in conduit​ (30 °C ambient), making it ideal for lighting branch circuits, small appliance outlets, and control wiring.

  • Controlled Thermal Aging​ — The PVC compound exhibits low thermal deformation and high resistance to embrittlement over decades of service life.

1.0mm2 Solid Copper Conductor Annealed 18 Awg Bare Copper Wire

Mechanical Durability

  • Solid Copper Conductor (Class 1)​ — 1.13 mm diameter annealed copper rod delivers high tensile strength and dimensional stability. The solid construction resists stretching during pulling and maintains secure terminations under screw-clamp connections.

  • Uniform Insulation Extrusion​ — 0.6 mm nominal PVC wall thickness is applied via precision extrusion, producing a smooth, concentric profile with an average overall diameter not exceeding 2.8 mm​ — compact enough for dense conduit fills.

  • Good Flexibility for Installation​ — While solid, the 1.0 mm² gauge offers manageable bending characteristics with a minimum bend radius of 4× diameter (~11 mm), suitable for standard conduit bends and panel routing.

  • Abrasion & Impact Resistance​ — The PVC jacket provides effective protection against minor mechanical abrasion, crushing, and impact when installed in conduit or trunking.

1.0mm2 Solid Copper Conductor Annealed 18 Awg Bare Copper Wire

Safety Characteristics

  • Flame Retardant​ — Passes GB/T 18380.1​ single-cable vertical flame test, self-extinguishing once the ignition source is removed, limiting flame spread along the cable length.

  • Electrical Isolation​ — High-quality PVC formulation ensures consistent dielectric properties, protecting against accidental contact and short circuits.

  • Color-Coded Identification​ — Available in Red, Black, Blue, Yellow/Green (earth), White, Brown, Grey, and Orange for intuitive phase, neutral, and protective conductor identification per regional wiring codes.

1.0mm2 Solid Copper Conductor Annealed 18 Awg Bare Copper Wire

1.0mm2 Solid Copper Conductor Annealed 18 Awg Bare Copper Wire

Environmental & Chemical Resistance

  • Moisture Tolerance​ — Suitable for dry to damp locations (not wet or submerged). Performs reliably in typical indoor humidity conditions.

  • Chemical Stability​ — Resistant to common household and industrial chemicals including mild acids, alkalis, oils, and solvents at ambient temperatures.

  • UV Limitation​ — Not rated for prolonged direct sunlight exposure; outdoor or rooftop runs require UV-protective conduit or raceway.

  • Service Life​ — Expected service life of 25+ years​ under normal indoor installation conditions with proper derating.

1.0mm2 Solid Copper Conductor Annealed 18 Awg Bare Copper Wire

Installation & Handling

Aspect

Recommendation

Installation Method

Conduit, trunking, cable tray (covered), behind drywall, inside switchgear & distribution boards

Termination

Screw terminals, push-in connectors, crimp lugs (strip insulation 8–10 mm)

Pulling Tension (max)

≤ 50 N (avoid sharp bends during pull)

Minimum Install Temp.

0 °C (below 0 °C, warm wire or use cold-flexible compound)

Storage

Cool, dry location; avoid direct sun and stacking heavier reels on top

Reel Lengths

Typically 100 m, 200 m, 500 m (custom lengths available)

 

Color Selection

1.0mm2 Solid Copper Conductor Annealed 18 Awg Bare Copper Wire

 

Application Scope

Primary Applications:

  • Residential lighting and small-power circuits

  • Commercial office fit-out wiring (switches, sockets, controls)

  • Internal wiring of distribution boards, consumer units, and switchgear

  • Control panel interconnections and instrumentation loops

  • HVAC control circuits and thermostat wiring

1.0mm2 Solid Copper Conductor Annealed 18 Awg Bare Copper Wire

 

1.0mm2 Solid Copper Conductor Annealed 18 Awg Bare Copper Wire

 

Typical Projects:

  • Apartment buildings, villas, and townhouses

  • Schools, retail stores, and restaurants

  • Light industrial workshops and warehouses

  • Renovation and retrofit of legacy electrical installations

1.0mm2 Solid Copper Conductor Annealed 18 Awg Bare Copper Wire

1.0mm2 Solid Copper Conductor Annealed 18 Awg Bare Copper Wire

Product Selection Guide

 

If your project requires…

Recommended alternative

Fire-resistant circuit integrity (emergency lighting, fire pumps)

NH-BV​ or WDZBN-BYJ​

Low-smoke, zero-halogen for public occupancy buildings

WDZ-BYJ​ or WDZBN-BYJ​

90 °C operating temperature

BYJ​ (XLPE insulated)

Flexible stranded conductor for vibration/tight bends

BVR​ 1.0 mm² (Class 5)

Direct burial or outdoor exposed run

Use armored cable or UV-rated jacketed type


Quality Assurance

Every production batch undergoes in-process and final inspection covering:

  • Conductor resistance measurement

  • Insulation thickness and concentricity verification

  • High-voltage withstand test (spark test or immersion)

  • Flame retardancy sampling

  • Dimensional and visual inspection

Test reports and Certificate of Compliance (CoC)​ are available upon request, referencing batch number and manufacturing date.


Summary

The BV 1.0 mm² / 18 AWG​ building wire represents the industry-standard choice for general-purpose fixed electrical wiring where cost-effectiveness, proven safety, and regulatory compliance are priorities. It combines a low-resistance solid copper core with durable PVC insulation to deliver stable, maintenance-free performance across the full service life of a building's electrical infrastructure. For projects demanding enhanced fire safety, low-smoke, or higher temperature ratings, the same manufacturer offers direct upgrade paths within the WDZ, NH, and BYJ​ product families.