"1 electrical building wires"
- 90 Items Found
ZR-YJV 4×70mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution
ZR-YJV 4×70mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×70 mm² Four equal cores of 70 mm² copper ...
5x16mm2 5 Cores Cable Copper Xlpe Insulated Armoured For Building MEP Works
5*16mm² Flame Retardant Power Cable ZR-YJV Copper Conductor for Building MEP Works Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 5×16 mm² Five equal cores of 16 mm² copper conductor Construction : ...
DC Solar Wire 6.0mm² PV1-F TUV UV Resistant Photovoltaic Cable PV String Main Cable
DC Solar Wire 6.0mm² PV1-F TUV UV Resistant Photovoltaic Cable PV String Main Cable Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper ...
RVVP 2x1.5mm² Shielded Control Panel Wire Braided Copper Relay Circuit EMI Protection 300/500V
RVVP 2x1.5mm² Shielded Control Panel Wire Braided Copper Relay Circuit EMI Protection 300/500V Cable Designation & Meaning Code Meaning R Flexible conductor (Class 5 fine-stranded) V PVC insulation V PVC sheath P Copper wire shield (braid or braid+tape) 2×1.5 mm² Two cores, each 1.5 mm² copper ...
ZR-YJV 1*50mm² Flame Retardant Cable, 0.6/1kV Pure Copper XLPE Insulation PVC Sheath for Power Wiring
ZR-YJV 1*50mm² Flame Retardant Cable, 0.6/1kV Pure Copper XLPE Insulation PVC Sheath for Power Wiring Code Mean:ZR-Flame Retardant, YJ-XLPE Insulation, V-PVC Outer Sheathed. ZR-YJV 1×50 mm² — Detailed Product Introduction ZR-YJV 1×50 is a flame-retardant, copper-conductor, XLPE-insulated, PVC...
Copper Conductor Flame Retardant XLPE Cable ZR-YJV 3×95mm²+1×50mm² for Site Power Wiring
Copper Conductor Flame Retardant XLPE Cable ZR-YJV 3×95mm²+1×50mm² for Site Power Wiring Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 3×95 mm² + 1×50 mm² Three phase cores of 95 mm² + one neutral ...
4x10mm2+1x6mm2 XLPE Copper Cable 0.6kV 1kV Flame Retardant
ZR-YJV 4x10mm²+1x6mm² XLPE Copper Cable 0.6/1kV Flame Retardant Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×10 mm² + 1×6 mm² Four cores of 10 mm² (3 phase + 1 neutral) + one earth core of 6 mm² ...
High Rise Building Main Cable ZR-YJV 4x95mm²+1x50mm² XLPE Copper Flame Retardant
High Rise Building Main Cable ZR-YJV 4x95mm²+1x50mm² XLPE Copper Flame Retardant Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×95 mm² + 1×50 mm² Four cores of 95 mm² (3 phase + 1 neutral) + one ...
5 Core Multi Core Control Cable 0.75mm2 RVV For Building Automation
Multi Core Control Cable 5 Core 0.75mm² RVV for Building Automation Cable Designation & Meaning Code Meaning RVV R = Flexible copper conductor (Class 5), V = PVC insulation, V = PVC sheath 300/500 V Rated voltage U₀/U = 300/500 V; Uₘ = 500 V 5×0.75 mm² Five flexible cores, each 0.75 mm² copper ...