logo
Anhui Tongdu International Trade Co., Ltd.
Online Service

Online Service

Contact Person
+86 19056002718
WeChat QR Code
Follow Us

3x120mm2 Medium Voltage Power Cable 8.7kV 15kV Aluminum Mc Cable

3x120mm2 Medium Voltage Power Cable 8.7kV 15kV Aluminum Mc Cable

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
YJLV22-3x120mm²

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
100000 meters per month

Product Summary

Industrial Main Aluminum Cable YJLV22 3x120mm² 8.7/15kV Armored MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor​ (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated ...

Product Details

Highlight:

3x120mm2 medium voltage power cable

,

medium voltage power cable 8.7kv

,

15kv aluminum mc cable

Conductor (×3):
Aluminium, Class 2 Stranded Circular, Typical 19×∅2.83 Mm (120 Mm²), Conductor Ø ≈ 14.2–15.5 Mm
Conductor screen:
Extruded Semi-conductive Compound (XLPE-based)
Insulation:
XLPE (cross-linked Polyethylene), Nominal Thickness 4.5 Mm​ (8.7/10 KV & 8.7/15 KV)
Insulation screen:
Extruded Semi-conductive Compound (strippable Or Bonded)
Metallic screen (per core):
Copper Tape, Copper Wire, Or Combined Copper Tape + Wire, Min. Cross-section 16 Mm² (typically 1×0.1 Mm Copper Tape Overlapping)
Filler & bedding:
PVC Filler + PVC Inner Bedding (tape Wrap Or Extruded), Thickness ≈ 1.5–2.0 Mm
Armour:
Double Steel Tape, 0.5 Mm × 2
Outer sheath:
PVC (polyvinyl Chloride), Nominal Thickness 2.5–3.0 Mm (typical), Color: BlacK
Conductor nominal area:
120 Mm² (Al)
Number of cores:
3
Conductor material:
Aluminium (Al)
Conductor class:
Class 2 Stranded
Conductor construction:
19×∅2.83 Mm (typical)
Conductor diameter (approx.):
14.2–15.5 Mm
Conductor screen thickness:
0.5 Mm
Insulation thickness:
4.5 Mm
Insulation screen thickness:
0.5 Mm
Diameter over insulated core (approx.):
21.2–22.5 Mm
Metallic screen:
Copper Tape 0.1 Mm Overlapping
Inner bedding thickness:
1.5–2.0 Mm
Outer sheath thickness:
2.5–3.0 Mm
Overall cable diameter:
58 – 67 Mm
Design outer diameter:
≈ 61.5 Mm
Approx. weight:
6.8 – 8.4 Kg/m (6800–8400 Kg/km)
Design weight:
≈ 7600 Kg/km

Product Description

Industrial Main Aluminum Cable YJLV22 3x120mm² 8.7/15kV Armored MV

Cable Designation & Meaning

 

Code

Meaning

YJ

XLPE (cross-linked polyethylene) insulation

L

Aluminium conductor​ (Al)

V

PVC inner bedding / outer sheath

22

Steel tape armour (double steel tape, overlapping) + PVC sheath

8.7/10 kV

Rated voltage U₀/U = 8.7/10 kV; Uₘ = 12 kV

8.7/15 kV

Rated voltage U₀/U = 8.7/15 kV; Uₘ = 17.5 kV

3×120 mm²

Three power cores, each 120 mm² aluminium (3-core, no neutral, no PE)

 

Construction: XLPE insulated, aluminium conductor, steel-tape armoured, PVC sheathed, three-core medium-voltage power cable.

Applicable Standards

  • GB/T 12706.2-2020 / IEC 60502-2 — Power cables with extruded insulation and their accessories for rated voltages from 6 kV up to 30 kV
  • GB/T 3956 / IEC 60228 — Conductors (Class 2 stranded circular, aluminium)
  • GB/T 2951 / IEC 60811 — Insulating and sheathing materials — Common test methods
  • GB/T 3048 — Test methods for electric cables
  • GB/T 18380 / IEC 60332 — Flame retardant tests (Category C or B available)

3x120mm2 Medium Voltage Power Cable 8.7kV 15kV Aluminum Mc Cable

3x120mm2 Medium Voltage Power Cable 8.7kV 15kV Aluminum Mc Cable

YJLV22-3×120 mm² 8.7/10 kV (and 8.7/15 kV) — Cable Specification & Engineering Data 

1. Product Overview & Rating Summary. YJLV22-3×120 is an extra-large-size medium-voltage (MV) power cable rated 8.7/10 kV (Um = 12 kV) at 50 Hz, built around three 120 mm² compacted-stranded ALUMINIUM conductors, each with a triple-extruded semi-conducting screen / XLPE insulation / semi-conducting screen system, a lapped copper-tape screen, and an overall double-galvanised-steel-tape armour (type 22) with a black PVC outer jacket. The "L" in YJLV22 distinguishes the aluminium conductor from the copper YJV22 — same insulation and armour system, but at roughly one-third the weight and one-third the conductor cost. The same construction is also manufactured in the 8.7/15 kV grade (Um = 17.5 kV) with thicker 5.5 mm XLPE insulation. The cable is designed for 10 kV distribution mains serving 6300–10000 kVA distribution transformers and MV motors in the 2500–4000 kW range. Finished diameter is about 85 mm (10 kV) and nominal mass about 9300 kg/km (≈ 930 kg per 100 m). With all three cores loaded, the cable carries about 270 A in free air at 25 °C (engineering estimate). At this cross-section the aluminium conductor approaches the practical upper limit for 10 kV trunk feeders; beyond this size most projects either switch to copper or move to 26/35 kV feeders.

 

2. Layer-by-Layer Construction (Conductor to Outer Jacket).

Layer Construction Wall Diameter
Conductor (Al) ×3 Compacted stranded annealed Al, Class 2 — 30×2.25 mm equivalent — ≈ 15.0 mm
Conductor screen Extruded semi-conducting XLPE, co-extruded ≈ 0.8 mm ≈ 16.6 mm
XLPE insulation Cross-linked polyethylene, triple-extruded 4.5 mm (10 kV) / 5.5 mm (15 kV) ≈ 28.0 / ≈ 30.0 mm
Insulation screen Strippable semi-conducting XLPE ≈ 0.8 mm ≈ 29.6 / ≈ 31.6 mm
Copper-tape screen 0.1 × 25 mm annealed Cu tape, lapped ≈ 0.1 mm tape ≈ 29.8 / ≈ 31.8 mm
Filler & bedding PP/PE rope + non-woven binder — ≈ 75 / ≈ 78 mm bundle
Inner sheath PVC/PE extruded bedding ≈ 1.5 mm ≈ 78 / ≈ 81 mm
Steel armour (type 22) Double galvanised steel tape, helical lapped 2 × 0.5 mm ≈ 79 / ≈ 82 mm
PVC outer jacket ST2 PVC, flame-retardant, black 2.8 mm ≈ 85 / ≈ 88 mm (finished)

 

3. Electrical Characteristics. Each 120 mm² aluminium conductor is held to a maximum DC resistance of 0.253 Ω/km at 20 °C — about 21% lower resistance than the 95 mm² aluminium version, which translates directly into higher ampacity and lower voltage drop on long MV runs. Every length survives the routine 21.5 kV AC power-frequency proof held for five minutes (30.5 kV for the 15 kV grade). Partial discharge at 1.5 U0 must not exceed 20 pC. Dissipation factor tan δ ≤ 0.001 at U0. Insulation resistance ≥ 1000 MΩ·km, typical capacitance ≈ 0.75 μF/km. Impulse withstand (BIL) is 75 kV for the 10 kV grade and 95 kV for the 15 kV grade. With all three cores energised, reference loading is about 270 A in free air at 25 °C, about 260 A direct-buried.

Insulation Data

Property

Value

Material

XLPE (cross-linked polyethylene)

Nominal thickness

4.5 mm

Long-term service temp.

90 °C

Short-circuit temp. (≤5 s)

250 °C​ (Al conductor limit per IEC 60228)

Emergency overload temp.

130 °C

Routine test voltage (AC, 5 min)

22 kV (8.7/10 kV); 30.5 kV (8.7/15 kV)

Type-test voltage (AC)

30 kV (8.7/10 kV); 45 kV (8.7/15 kV)

Partial discharge test

≤ 10 pC at 1.73 U₀ (15 kV)

Tan δ (dissipation factor)

≤ 0.004 at 20 °C

Electrical Parameters

 

Parameter

Value (8.7/10 kV)

Value (8.7/15 kV)

Note

Rated voltage U₀/U

8.7 / 10 kV

8.7 / 15 kV

—

Max. system voltage Uₘ

12 kV

17.5 kV

—

Test voltage AC (5 min)

22 kV

30.5 kV

Routine

Type-test voltage

30 kV

45 kV

—

DC resistance @20 °C

≤ 0.253 Ω/km

≤ 0.253 Ω/km

GB/T 3956 Class 2 Al max, 120 mm²

AC resistance @90 °C (est.)

≈ 0.323 Ω/km

≈ 0.323 Ω/km

per core

Capacitance (approx.)

≈ 0.34 µF/km

≈ 0.34 µF/km

per core to screen

Inductive reactance (approx.)

≈ 0.12 Ω/km

≈ 0.12 Ω/km

at 50 Hz, 3-core

Current rating in air (30 °C)

≈ 225 – 250 A

≈ 225 – 250 A

per core, 3-core (Al)

Current rating buried (20 °C)

≈ 195 – 220 A

≈ 195 – 220 A

direct buried, 3-core

Short-circuit current (1 s, Al, 250 °C)

≈ 12.0 kA (12000 A)

≈ 12.0 kA (12000 A)

120 mm² Al

Frequency

50/60 Hz AC

50/60 Hz AC

—

Reference values: 120 mm² Al at 235 A, 3-phase 10 kV → max balanced load ≈ 4.07 MVA. Voltage drop at 235 A ≈ 7.6 V/km per core (≈0.076% per 100 m).

Temperature Characteristics

Property

Value

Max. conductor operating temp.

90 °C (continuous)

Max. short-circuit temp. (≤5 s)

250 °C (Al conductor)

Emergency overload temp.

130 °C

Min. installation ambient temp.

0 °C (PVC sheath); below 0 °C pre-heating required

Service ambient range

−20 °C to +90 °C (with PVC sheath)

Fire survival

Standard (non-fire-rated); optional fire-resistant version available (ZC-YJLV22)

 

4. Thermal Response & Flame Behaviour. XLPE insulation sustains a 90 °C continuous conductor temperature, with short-circuit capability up to 250 °C for ≤ 5 s. The cable is rated for service ambients between −20 and +50 °C. PVC jacket provides flame-retardant performance per GB/T 18380.34 class A. Short-circuit rating at 250 °C for 1 s is about 8.1 kA for the 120 mm² aluminium conductor — about 27% higher than the 95 mm² version, now matching the fault levels typical of urban 10 kV distribution networks. Thermal resistance of reference burial soil is 1.2 K·m/W.

Fire Performance (YJLV22 — Standard)

Property

Value / Requirement

Flame retardant

GB/T 18380.3 Category C (ZC), Category B (ZB) available

Halogen content

Contains halogen (PVC sheath)

Smoke density

Standard (non-low-smoke)

Corrosivity

Corrosive (PVC sheath)

Fire survival (circuit integrity)

Not applicable (standard version); use ZA-YJLV22 for flame-retardant A

 

5. Installation Practice & Handling. Bends must not fall below 15 times the actual outer diameter — about 1275 mm for this size. The steel armour must be earthed at both ends; the copper-tape screen must be bonded per MV practice. Critically, the aluminium conductors must be terminated with bimetallic Al-Cu lugs — direct contact between aluminium and copper in the presence of moisture causes galvanic corrosion and joint failure. MV heat-shrink or cold-shrink termination kits are mandatory. Laying temperature must not fall below 0 °C. At about 930 kg per 100 m, this is at the practical upper limit for aluminium MV cable; forklifts, winches, rated pulling grips and multiple laying crews are essential.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 15 × OD → ≈ 923 mm at Ø61.5 mm

static installation

Max. pulling tension

7200 N

Al conductor has ~60% of Cu tensile strength; use proper pulling grips

Direct burial

Suitable

steel tape armour provides mechanical protection

Conduit ID

≥ 1.5 × OD → ≥ 93 mm; use 100 mm, 110 mm or 125 mm

—

Fixing

cable clamps, steel straps

—

Impact resistance

High

steel tape armour absorbs mechanical shock

Water resistance

Moisture-resistant (PVC sheath + inner bedding)

not fully watertight; use YJLV32 for wet locations

Armour type

Double steel tape, overlapping

galvanized or mill finish

Armour short-circuit rating

≈ 5 kA (1 s, steel tape)

—

Termination note

Al conductors require Al-compatible lugs​ (bimetallic or Al-Cu transition)

critical for installation

 

6. Typical Service Applications. This YJLV22-3×120 aluminium MV cable is the extra-large-size cost-effective choice for 10 kV / 15 kV distribution mains where mechanical strength and burial protection are needed and loads are heavy: 6300–10000 kVA distribution transformer primary feeds in CBD commercial districts, high-rise building 10 kV incoming mains, large industrial park trunk feeders, 10 kV main feeds to very large industrial plants and process workshops, MV motor branch feeds for motors in the 2500–4000 kW range (very large pumps, fans, compressor stations, mill drives, crusher and conveyor drives, main ventilation fans), township and county 10 kV overhead-to-underground trunk feeders, municipal water-supply and wastewater 10 kV trunk mains, large PV / solar-farm 10 kV collection mains, mining and quarry 10 kV heavy-duty power supply lines, and any circuit where the lightweight aluminium conductor reduces installation and support-structure costs relative to copper. Approved installation methods include direct burial, cable tray, concrete duct, and indoor MV cable trench.

 

3x120mm2 Medium Voltage Power Cable 8.7kV 15kV Aluminum Mc Cable

 

7. Testing & Quality Assurance Regime. Routine tests on every length include conductor DC resistance ≤ 0.253 Ω/km at 20 °C, the 21.5 kV AC / 5 min withstand (30.5 kV for 15 kV grade), partial discharge ≤ 20 pC at 1.5 U0, tan δ ≤ 0.001, insulation resistance ≥ 1000 MΩ·km, conductor continuity across all three cores, steel-armour and copper-screen continuity, and dimensional inspection. Sample and type tests comprise impulse withstand at ±75 kV (or ±95 kV for 15 kV), heating-cycle load-loss test, bending at 15 × OD, short-circuit to 250 °C, flame spread GB/T 18380.34 class A, and voltage re-test after thermal ageing. A factory test certificate accompanies each drum.

 

Cable Parameters

 

YJLV22-3×120 mm² 8.7/10 kV (and 8.7/15 kV variant) — Full Parameter Sheet (English)
Medium-voltage power cable · ALUMINIUM conductor / XLPE insulation / copper-tape screen / double-steel-tape armour (type 22) / PVC outer sheath · per GB/T 12706.2 · 3 cores · finished Ø ≈ 85 mm (10 kV) / ≈ 88 mm (15 kV)
Section Parameter Value Unit Remarks / Standard
01 · Identification
  Cable type YJLV22 — Al conductor / XLPE insulation / double-steel-tape armour / PVC outer sheath
  Rated voltage (U0/U) 8.7/10 kV AC 50 Hz; Um = 12 kV (10 kV grade)
  Alternative voltage grade 8.7/15 kV AC 50 Hz; Um = 17.5 kV (15 kV grade) — thicker XLPE
  Number of cores 3 × 120 — 3 phase cores (120 mm²) — no separate neutral in MV cable
  Conductor material Compacted stranded ALUMINIUM — Class 2 stranded per GB/T 3956; lighter, lower cost than Cu
  Conductor screen Extruded semi-conducting XLPE — Conductor screen layer (radial field control)
  Insulation material Cross-linked polyethylene (XLPE) — 90 °C continuous, 250 °C short-circuit
  Insulation screen Extruded semi-conducting, strippable — Outer screen layer
  Metallic screen Copper tape, lapped — 0.1 × 25 mm Cu tape; equipotential earth
  Armour Double galvanised steel tape — Type 22 armour — mechanical protection
  Outer sheath PVC (ST2), flame-retardant — UV- and abrasion-resistant
  Standard reference GB/T 12706.2 / IEC 60502-2; GB/T 3956 — Medium-voltage power cables 1.8/3 kV to 26/35 kV
02 · Conductor (Aluminium)
  Stranding — 120 mm² Compacted stranded aluminium — Class 2, circular compacted
  Strand count (typical) 30 × 2.25 mm (or 19 × 2.80 mm equivalent) — Compacted after stranding
  Conductor diameter ≈ 15.0 mm After compacting (est.)
  DC resistance @ 20 °C ≤ 0.253 Ω/km Maximum per GB/T 3956 Class 2 (Al)
  AC resistance @ 50 Hz (≈ 90 °C) ≈ 0.37 Ω/km Skin/proximity effect included
  Conductor screen thickness ≈ 0.8 mm Extruded semi-conducting layer
  Conductor weight per km ≈ 324 kg/km Aluminium density 2.70 g/cm³
03 · Insulation
  Insulation type Cross-linked polyethylene (XLPE) — Extruded, triple-layer co-extrusion
  Insulation thickness — 8.7/10 kV 4.5 mm Nominal, per GB/T 12706.2
  Insulation thickness — 8.7/15 kV 5.5 mm Thicker for 15 kV grade
  Core Ø over insulation — 10 kV ≈ 28.0 mm 15.0 + 2×(0.8+4.5+0.8)
  Core Ø over insulation screen — 15 kV ≈ 30.0 mm 15.0 + 2×(0.8+5.5+0.8)
  Insulation screen thickness ≈ 0.8 mm Strippable semi-conducting
  Impulse withstand (BIL) — 10 kV 75 kV Lightning impulse test
  Impulse withstand (BIL) — 15 kV 95 kV Lightning impulse test
04 · Metallic Screen & Filler
  Screen material Annealed copper tape — Lapped with overlap
  Screen tape dimensions 0.1 × 25 mm Two layers lapped (typical)
  Screen function Equipotential earth / fault-current path — Earthed at terminations
  Filler material PP / jute rope, flame-retardant — Fills interstices for round cable
  Bedding / binder tape Semi-conducting or non-woven tape — Holds bundle; anti-corrosion layer
  Assembled bundle Ø — 10 kV ≈ 75 mm Before inner sheath (est.)
  Assembled bundle Ø — 15 kV ≈ 78 mm Before inner sheath (est.)
05 · Inner Sheath & Armour
  Inner sheath / bedding PVC or PE extruded — Corrosion barrier under armour
  Inner sheath thickness ≈ 1.5 mm Over bundle
  Armour type Double steel tape (type 22) — Double-tape helical armour
  Armour tape thickness 2 × 0.5 mm Galvanised steel, lapped
  Armour function Mechanical protection against crush / impact — Permits direct burial / tray
  Armour diameter — 10 kV ≈ 79 mm Over inner sheath (est.)
06 · Outer Sheath
  Jacket material PVC, ST2, flame-retardant — GB/T 12706.1
  Jacket thickness 2.8 mm Minimum over armour
  Overall finished diameter — 10 kV ≈ 85 mm Cross-referenced industry sample
  Overall finished diameter — 15 kV ≈ 88 mm Thicker insulation version
  Approx. cable mass — 10 kV ≈ 9300 kg/km Al + XLPE + steel + PVC (lightweight)
  Approx. cable mass — 15 kV ≈ 9600 kg/km Heavier due to thicker insulation
  Jacket colour Black (standard) — UV-resistant carbon-black PVC
  Mass per 100 m — 10 kV ≈ 930 kg/100 m For drum loading
07 · Electrical
  Rated voltage U0/U 8.7/10 kV AC 50 Hz; Um = 12 kV
  Maximum system voltage Um (10 kV) 12 kV —
  DC resistance @ 20 °C ≤ 0.253 Ω/km 120 mm² Al Class 2
  Insulation resistance ≥ 1000 MΩ·km XLPE at 20 °C
  Capacitance (typical) ≈ 0.75 μF/km Per core (est.)
  Dissipation factor tan δ (at U0) ≤ 0.001 — XLPE, 20 °C
  Routine test voltage (AC) — 10 kV 21.5 kV / 5 min — Power-frequency withstand
  Routine test voltage (AC) — 15 kV 30.5 kV / 5 min — Power-frequency withstand
  Air ampacity @ 25 °C ≈ 270 A 3 cores loaded, Al, in free air (est.)
  Buried ampacity @ 25 °C soil ≈ 260 A 3 cores loaded, Al, direct burial (est.)
08 · Thermal & Fire
  Max continuous conductor temp. 90 °C Normal service
  Short-circuit temp. (≤ 5 s) 250 °C XLPE limit
  Fire behaviour Flame-retardant (PVC jacket) — GB/T 18380.34 class A
  Service ambient range −20 to +50 °C Fixed installation
  Thermal resistance (soil) 1.2 K·m/W Reference burial conditions
  Short-circuit rating (1 s) ≈ 8.1 kA 120 mm² Al at 250 °C
09 · Installation
  Min bending radius ≥ 15 × OD ≈ 1275 mm Fixed installation (armoured)
  Laying temperature ≥ 0 °C Pre-heat below 0 °C
  Laying methods Tray, direct burial, conduit, duct — Armour permits direct burial
  Armour earthing Both ends earthed — Steel armour must be earthed
  Copper screen earthing At both ends (or single point for cross-bonding) — MV cable screen bonding
  Termination / joints Al-Cu transition lugs required — Al conductor — use bimetallic lugs to avoid galvanic corrosion
  Special tools Cable cutter, crimping tool, torque wrench — MV lugs required; winch / cable grip essential
10 · Packing
  Standard supply length 500 or 1000 m/drum Custom cut lengths available
  Reel / packing type Wooden-steel drum — Sealed ends against moisture
  Surface marking YJLV22, 8.7/10 kV, 3×120, supplier, year, metre marks — Per GB/T 6995
  Storage conditions Dry, covered, −20 to +40 °C — Sealed ends; protect from UV
  Transport Drums secured against rolling — Heavy cable; forklift / crane required

 

Cable Test Parameters

 

Test Parameters — YJLV22-3×120 mm² 8.7/10 kV (and 8.7/15 kV)
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance GB/T 3048.4, 20 °C ≤ 0.253 Ω/km (120 mm² Al) Routine
2 Power-frequency withstand (routine) 21.5 kV AC, 5 min (10 kV grade) No breakdown Routine
3 Power-frequency withstand (15 kV grade) 30.5 kV AC, 5 min No breakdown Routine
4 Partial discharge test At 1.5 U0 = 13 kV (10 kV grade) ≤ 20 pC at 1.73 U0 Routine
5 Dissipation factor tan δ At U0, 20 °C tan δ ≤ 0.001 Routine
6 Insulation resistance GB/T 3048.5 ≥ 1000 MΩ·km Routine
7 Dimensional check Micrometer / micrometer microscope Insulation ≥ 4.5 mm (10 kV); jacket ≥ 2.8 mm Routine
8 Impulse voltage test (BIL) ±75 kV, 10 impulses (10 kV grade) No breakdown at 75 kV Type
9 Impulse voltage test (15 kV grade) ±95 kV, 10 impulses No breakdown at 95 kV Type
10 Heating cycle / load loss 3 cycles U0 + rated current No damage; tan δ stable Type
11 Bending test 15 × OD mandrel, 3 cycles No damage to insulation or sheath Type
12 Short-circuit temperature test 250 °C, 5 s equivalent No insulation collapse Type
13 Flame propagation GB/T 18380.34 class A No vertical flame spread Type
14 Sheath / armour continuity Continuity meter Steel armour and Cu tape continuous Routine
15 Voltage test after ageing After thermal ageing cycle Withstands 2.5 U0 AC Type
16 Marking legibility Visual + rubbing YJLV22 / 8.7/10 kV / 3×120 / metre marks legible Routine

 

Cable Cross Section Structure

 

3x120mm2 Medium Voltage Power Cable 8.7kV 15kV Aluminum Mc Cable

 

 

YJLV22-3×120 mm² 8.7/10 kV — Cross-Section Construction Diagram (Schematic)
MV layered build-up: ALUMINIUM conductor → conductor screen → XLPE insulation → insulation screen → Cu-tape screen → filler → bedding → double-steel-tape armour → PVC jacket · 8.7/10 kV (8.7/15 kV variant noted) · finished Ø ≈ 85 mm
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor (Al) ×3 Compacted stranded ALUMINIUM, Class 2 — 30×2.25 mm equivalent per core — ≈ 15.0 Power conductor; R ≤ 0.253 Ω/km at 20 °C
2 Conductor screen Extruded semi-conducting XLPE, co-extruded with insulation ≈ 0.8 ≈ 16.6 Eliminates air gaps; smooth radial field
3 XLPE insulation Cross-linked polyethylene, triple-layer co-extrusion 4.5 (10 kV) / 5.5 (15 kV) ≈ 28.0 / ≈ 30.0 Main dielectric; 90 °C continuous
4 Insulation screen Strippable semi-conducting XLPE ≈ 0.8 ≈ 29.6 / ≈ 31.6 Outer screen; equipotential
5 Copper-tape screen Annealed Cu tape, lapped, 0.1 × 25 mm ≈ 0.1 tape ≈ 29.8 / ≈ 31.8 Earth path / fault-current return
6 Filler & bedding PP/PE rope filler + non-woven binder tape — ≈ 75 / ≈ 78 bundle Round shape; anti-corrosion bedding
7 Inner sheath PVC/PE extruded bedding over bundle ≈ 1.5 ≈ 78 / ≈ 81 Corrosion barrier under armour
8 Steel armour (type 22) Double galvanised steel tape, helically lapped 2 × 0.5 ≈ 79 / ≈ 82 Mechanical crush / impact protection
9 PVC outer jacket ST2 PVC, flame-retardant, black 2.8 ≈ 85 / ≈ 88 (finished) UV, abrasion and chemical protection
Key Dimensions & Properties (expanded)
Finished cable diameter (10 kV) ≈ 85 mm Cross-referenced industry sample    
Finished cable diameter (15 kV) ≈ 88 mm Thicker XLPE variant    
Approx. cable mass (10 kV) ≈ 9300 kg/km Al + XLPE + steel + PVC (lightweight)    
Approx. cable mass (15 kV) ≈ 9600 kg/km Heavier due to thicker insulation    
Nominal voltage rating 8.7/10 kV AC 50 Hz; Um = 12 kV    
Alternative voltage grade 8.7/15 kV Um = 17.5 kV; 5.5 mm XLPE    
Max continuous conductor temp. 90 °C Normal service    
Short-circuit temp. (≤5 s) 250 °C XLPE limit    
Impulse withstand (BIL) 75 (10 kV) / 95 (15 kV) kV Lightning impulse    
Min bending radius ≥ 15 × OD ≈ 1275 mm Fixed installation    
DC resistance @ 20 °C ≤ 0.253 Ω/km 120 mm² Al    
Insulation resistance ≥ 1000 MΩ·km XLPE    
Routine test voltage 21.5 kV AC / 5 min — 10 kV grade; 30.5 kV for 15 kV    
Air ampacity @ 25 °C ≈ 270 A 3 cores loaded, Al (est.)    
Mass per 100 m (10 kV) ≈ 930 kg/100 m For drum loading    
Schematic — not to exact scale. Finished Ø ≈ 85 mm (10 kV) and weight ≈ 9300 kg/km from cross-referenced industry samples; conductor/insulation diameters per GB/T 12706.2 and GB/T 3956; ampacity 270 A is an engineering estimate for ALUMINIUM conductors. The 8.7/15 kV variant uses 5.5 mm XLPE insulation, ≈ 88 mm OD and ≈ 9600 kg/km. Values marked (est.) require confirmation against the factory test certificate. Al conductors require bimetallic Al-Cu lugs at terminations. At this size the cable approaches the practical upper limit for aluminium MV trunk feeders.

 

Cable Construction Description

 

Construction Description — YJLV22-3×120 mm² 8.7/10 kV 
Layer-by-layer MV build-up narrative · 8.7/10 kV (and 8.7/15 kV variant) · ALUMINIUM / triple-extruded XLPE / Cu-tape screen / double-steel-tape armour / PVC jacket · finished Ø ≈ 85 mm
1. Product Identity & Ratings
YJLV22-3×120 is an extra-large-size medium-voltage (MV) power cable rated 8.7/10 kV (Um = 12 kV) at 50 Hz, built around three 120 mm² compacted-stranded ALUMINIUM conductors, each with a triple-extruded semi-conducting screen / XLPE insulation / semi-conducting screen system, a lapped copper-tape screen, and an overall double-galvanised-steel-tape armour (type 22) with a black PVC outer jacket. The 'L' in YJLV22 distinguishes the aluminium conductor from copper (YJV22). The same construction is also manufactured in the 8.7/15 kV grade (Um = 17.5 kV) with thicker 5.5 mm XLPE insulation. The cable is designed for 10 kV distribution mains serving 6300–10000 kVA distribution transformers and MV motors in the 2500–4000 kW range. Finished diameter is about 85 mm (10 kV) and nominal mass about 9300 kg/km (≈ 930 kg per 100 m). With all three cores loaded, the cable carries about 270 A in free air at 25 °C (engineering estimate).
2. Aluminium Conductor & Screens
Each 120 mm² conductor is compacted-stranded aluminium (Class 2), with a strand-lay diameter of about 15.0 mm and DC resistance ≤ 0.253 Ω/km at 20 °C — roughly 21% lower resistance than the 95 mm² aluminium version. Aluminium is roughly one-third the weight of copper and one-third the cost, but it has roughly 60% lower conductivity — hence the larger cross-section needed for a given current. A semi-conducting conductor screen (≈ 0.8 mm) is co-extruded directly over the aluminium to eliminate air gaps and smooth the electric field. The conductor screen bonds electrically to the aluminium.
3. XLPE Insulation
Cross-linked polyethylene (XLPE) is extruded in a triple-layer co-extrusion process: conductor screen → XLPE insulation → insulation screen, all in one pass to avoid contamination. For the 8.7/10 kV grade the insulation thickness is 4.5 mm; for the 8.7/15 kV grade it is 5.5 mm. XLPE sustains 90 °C continuous conductor temperature and 250 °C short-circuit for ≤ 5 s. The outer insulation screen is strippable for termination work. Over the insulation screen a 0.1 × 25 mm copper tape is lapped to provide an equipotential earth and fault-current return path.
4. Bedding, Steel Armour & PVC Jacket
Three screened cores are cabled round with PP/PE rope filler and a non-woven binder tape, giving a bundle of about 75 mm (10 kV). A PVC/PE inner bedding (≈ 1.5 mm) is extruded over the bundle, then a double layer of 0.5 mm galvanised steel tape is helically lapped — this is the type-22 armour that protects against crush and impact and permits direct burial. Finally a 2.8 mm black PVC (ST2) outer jacket is extruded over the armour to the ≈ 85 mm finish, providing UV, abrasion and chemical resistance.
5. Site Handling & Operational Notes
• Observe the 15 × OD minimum bending radius (≈ 1275 mm).  • The steel armour must be earthed at both ends; the copper-tape screen must be bonded per MV practice.  • Use bimetallic Al-Cu lugs at all terminations — direct Al-to-Cu contact causes galvanic corrosion.  • Service ambient −20 to +50 °C; conductor up to 90 °C continuous.  • Routine test 21.5 kV AC / 5 min (10 kV); impulse withstand 75 kV.  • At ≈ 930 kg/100 m, this is at the practical upper limit for aluminium MV cable; forklifts, winches and rated pulling grips are essential. Beyond 120 mm², most projects switch to copper or to 26/35 kV-grade feeders.

 

 

8. Factory Advantages

 

3x120mm2 Medium Voltage Power Cable 8.7kV 15kV Aluminum Mc Cable

 

9. Packaging, Storage & Logistics. Standard delivery is 500 m or 1000 m per wooden-steel drum, with bespoke cut lengths available on request. Each drum carries type (YJLV22), voltage, size, supplier identity, production year and sequential metre marking per GB/T 6995. Storage should be in dry, covered premises at −20 to +40 °C, shielded from direct sunlight and moisture; drum end seals must remain intact until installation. MV cable terminations and joints should be scheduled immediately after laying to avoid prolonged exposure of the cut aluminium ends. At this size each drum is very heavy and requires forklift or crane handling.

 

3x120mm2 Medium Voltage Power Cable 8.7kV 15kV Aluminum Mc Cable

 

10. Procurement Specification. State "YJLV22-8.7/10 kV-3×120" (or "YJLV22-8.7/15 kV-3×120" for the thicker-insulation grade) together with the required length or drum arrangement. Always order bimetallic Al-Cu lugs and MV termination kits at both ends — do not substitute pure copper lugs on aluminium conductors. Always request the factory test certificate, which must include the partial-discharge and impulse-withstand reports, to confirm the actual diameter, weight and conductor resistances for the production batch.

 

11. Cable Industry FAQ.

  • Q1: How does 120 mm² aluminium compare to 95 mm² aluminium? 120 mm² raises the reference ampacity from about 230 A to about 270 A (+17%), and lowers the DC resistance from 0.320 Ω/km to 0.253 Ω/km (−21%). It is the standard upgrade when the load grows beyond the 4000–6300 kVA transformer band and enters the 6300–10000 kVA range. The jacket also steps up from 2.6 mm to 2.8 mm. Weight rises from 7700 to 9300 kg/km. Beyond 120 mm², most projects either switch to copper or move to 26/35 kV feeders.
  • Q2: Why choose aluminium (YJLV22) over copper (YJV22)? Aluminium costs roughly one-third of copper per metre at the same cross-section and weighs roughly one-third, which reduces both material cost and installation labour for long MV runs. The trade-off is higher resistance — for the same ampacity you typically need to upsize by one or two cross-section steps. For heavily-loaded suburban, industrial-park and rural distribution mains, YJLV22 remains the standard cost-optimised choice up to around 120 mm².
  • Q3: What does the "L" in YJLV22 mean? "L" = aluminium conductor. Without the L, YJV22 uses copper. The "22" still means double-steel-tape armour over PVC jacket — identical mechanical and fire protection.
  • Q4: Why must I use bimetallic lugs? Aluminium and copper form a galvanic cell when directly connected in the presence of moisture. Over years this corrodes the aluminium at the joint, increasing resistance and eventually overheating. Bimetallic Al-Cu lugs have an aluminium barrel on the conductor side and a copper flange on the equipment side, isolating the two metals.
  • Q5: When do I choose 8.7/10 kV vs 8.7/15 kV? Choose 8.7/10 kV for nominal 10 kV distribution networks (Um = 12 kV). Choose 8.7/15 kV for nominal 15 kV networks (Um = 17.5 kV) or where the system may be up-rated — the thicker 5.5 mm XLPE gives a larger safety margin.
  • Q6: Why is there no separate neutral core? At MV distribution voltages, three-phase currents are balanced and the system is typically solidly or resistance-earthed; the copper-tape screen provides the earth path. A separate neutral is not required in standard 3-core MV construction.
  • Q7: Can this cable be directly buried? Yes — the double-steel-tape armour provides crush protection, and the PVC jacket is moisture-resistant. Direct burial depth and covering must follow the local MV cable installation code.
  • Q8: What is partial discharge and why is it tested? Partial discharge (PD) is tiny electrical sparks inside the insulation caused by voids or contaminants. At 1.5 U0, PD must be ≤ 20 pC. High PD values predict early insulation failure and are the most sensitive factory-quality indicator.
  • Q9: Why is the routine test 21.5 kV and not 10 kV? Routine tests apply a power-frequency withstand voltage higher than the rated voltage (typically 2.5 U0 = 21.75 kV, rounded to 21.5 kV) to catch manufacturing defects before site installation.
  • Q10: Is the short-circuit rating adequate? At 120 mm² aluminium, the 1 s short-circuit rating is about 8.1 kA — now matching urban 10 kV fault levels. For very high-fault-level networks (major substations, ring mains), upsizing to 150 mm² aluminium or switching to copper is recommended.
  • Q11: What service life can be expected? When installed, terminated and operated within the stated temperature, voltage and current ratings, XLPE-insulated MV cables — aluminium or copper — are designed for a service life of around 30 years in fixed installation. The dominant failure mode is moisture or PD at terminations, so professional jointing and proper bimetallic lugs are critical.