"low voltage power cable low voltage power cord"
- 89 Items Found
2 X 70mm2 2 Cores Cable ZR-YJV Flame Retardant PVC Insulation Jacket 0.6/1kV
ZR-YJV 2*70mm² Flame Retardant 2 Core Cable, 0.6/1kV, XLPE Insulation PVC Jacket for Construction Power Cable Designation & Meaning Code Meaning ZC Flame retardant C — IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 2×70 mm² Two cores, 70 mm² copper conductor ...
Copper Conductor 4 Cores Cable ZR-YJV 4x240mm2 Flame Retardant Cable For Industrial
Copper Conductor 4 Cores Cable ZR-YJV 4x240mm2 Flame Retardant Cable For Industrial Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×240 mm² Four cores of 240 mm² copper conductor each Construction ...
Copper 4 Cores Cable 3x10mm² + 1x6mm2 For Three Phase Power Wiring
3+1 Core ZR-YJV Flame Retardant Copper Cable 3x10mm²+1x6mm² for Three Phase Power Wiring Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer ...
4x70mm2+1x35mm2 Fire Resistant Cable 1KV 1.2KV Bare Copper Mineral Insulated Cable
Heavy Duty Fire Cable BTTRZ 4x70mm²+1x35mm² Mineral Insulated 0.6/1kV Cable Designation & Meaning Code Meaning BTTRZ Flexible mineral-insulated copper-sheathed fire-resistant cable 4×70 mm² Four cores of 70 mm² copper conductor (3 phase + 1 neutral) +1×35 mm² One core of 35 mm² copper conductor ...
4+1 Core Fire Resistant Cable 120mm2+1x70mm2 BTTRZ Fire Substation Cable
Fire Substation Cable 4+1 Core 120mm²+1x70mm² BTTRZ Fire Resistant Mineral Insulated Cable Designation & Meaning Code Meaning BTTRZ Flexible mineral-insulated copper-sheathed fire-resistant cable 4×120 mm² Four cores of 120 mm² copper conductor (3 phase + 1 neutral) +1×70 mm² One core of 70 mm² ...
BTTRZ Flame Retardant Cable 4x150mm2+1x70mm2 Mineral Insulated Cable
Ultra Fire Cable BTTRZ 4x150mm²+1x70mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ Flexible mineral-insulated copper-sheathed fire-resistant cable 4×150 mm² Four cores of 150 mm² copper conductor (3 phase + 1 neutral) +1×70 mm² One core of 70 mm² copper ...
4x185mm2+1x195mm2 Fire Resistant Cable 0.6KV 1KV Mineral Insulated Copper Cable
Super Fire Cable BTTRZ 4x185mm²+1x95mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ Flexible mineral-insulated copper-sheathed fire-resistant cable 4×185 mm² Four cores of 185 mm² copper conductor (3 phase + 1 neutral) +1×95 mm² One core of 95 mm² copper ...
ZR-YJV 4*16mm² Fire Retardant Four Conductor Cable, 0.6/1kV, XLPE PVC Sheath for Indoor Power Wiring
ZR-YJV 4*16mm² Fire Retardant Four Conductor Cable, 0.6/1kV, XLPE PVC Sheath for Indoor Power Wiring Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×16 mm² Four equal cores of 16 mm² copper ...
3+1 Core Flame Retardant 4 Cores Cable For Factory Three Phase Main Power
ZR-YJV 3+1 Core Flame Retardant Copper Cable 3x16mm²+1x10mm² for Factory Three-Phase Main Power Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC ...