logo
Anhui Tongdu International Trade Co., Ltd.
Online Service

Online Service

Contact Person
+86 19056002718
WeChat QR Code
Follow Us
Search Results For:

"high single strand copper wire"

- 90 Items Found
Quality Underground Distribution High Voltage Power Cable 3 Core 35mm2 YJV22 XLPE factory

Underground Distribution High Voltage Power Cable 3 Core 35mm2 YJV22 XLPE

Underground Distribution Cable 3 Core 35mm² YJV22 8.7/15kV Armored XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...

Quality Copper Core 5 Core Shielded Cable 4x50mm2+1x25mm2 XLPE Flame Retardant 0.6/1kV factory

Copper Core 5 Core Shielded Cable 4x50mm2+1x25mm2 XLPE Flame Retardant 0.6/1kV

Copper Core 4+1 Cable ZR-YJV 4x50mm²+1x25mm² XLPE Flame Retardant 0.6/1kV Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×50 mm² + 1×25 mm² Four cores of 50 mm² (3 phase + 1 neutral) + one earth ...

Quality PV1-F 4.0mm² TUV Certified Solar Cable 1500V DC UV Resistant Photovoltaic Wire factory

PV1-F 4.0mm² TUV Certified Solar Cable 1500V DC UV Resistant Photovoltaic Wire

PV1-F 4.0mm² TUV Certified Solar Cable 1500V DC UV Resistant Photovoltaic Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 4.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper ...

Quality 1500V Solar Pv Cable Halogen Free Class 5 Flexible PV Photovoltaic Wire factory

1500V Solar Pv Cable Halogen Free Class 5 Flexible PV Photovoltaic Wire

H1Z2Z2-K 6.0mm² TUV 1500V DC Solar Main Cable UV Resistant PV Photovoltaic Wire Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) ...

Quality 1*25mm² Single Core Cable, 0.6/1kV XLPE Insulation PVC Sheath for Indoor Power Wiring factory

1*25mm² Single Core Cable, 0.6/1kV XLPE Insulation PVC Sheath for Indoor Power Wiring

ZR-YJV 1*25mm² Flame Retardant Single Core Cable, 0.6/1kV Pure Copper XLPE Insulation PVC Sheath for Indoor Power Wiring ZR-YJV 1×25 mm² — Detailed Product Introduction Cable Designation & Meaning Code Meaning ZC Flame retardant C— IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) ...

Quality 2 X 50mm2 2 Core Shielded Cable Pvc Jacket Wire For Construction Power factory

2 X 50mm2 2 Core Shielded Cable Pvc Jacket Wire For Construction Power

ZR-YJV 2*50mm² Flame Retardant 2 Core Cable, 0.6/1kV Stranded Copper, XLPE Insulation PVC Jacket for Construction Power Cable Designation & Meaning Code Meaning ZC Flame retardant C — IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 2×50 mm² Two cores, 50 mm² ...

Quality ZR-YJV 3x240mm²+1x120mm² XLPE Copper Cable 0.6/1kV Flame Retardant factory

ZR-YJV 3x240mm²+1x120mm² XLPE Copper Cable 0.6/1kV Flame Retardant

ZR-YJV 3x240mm²+1x120mm² XLPE Copper Cable 0.6/1kV Flame Retardant Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 3×240 mm² + 1×120 mm² Three phase cores of 240 mm² + one neutral core of 120 mm² ...

Quality 4+1 Core 4*16mm² + 1*10mm² Copper Power Cable ZR-YJV XLPE Flame Retardant 0.6/1kV factory

4+1 Core 4*16mm² + 1*10mm² Copper Power Cable ZR-YJV XLPE Flame Retardant 0.6/1kV

4+1 Core 4*16mm² + 1*10mm² Copper Power Cable ZR-YJV XLPE Flame Retardant 0.6/1kV Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×16 mm² + 1×10 mm² Four cores of 16 mm² (3 phase + 1 neutral) + one ...

Quality High Rise Building Main Cable ZR-YJV 4x95mm²+1x50mm² XLPE Copper Flame Retardant factory

High Rise Building Main Cable ZR-YJV 4x95mm²+1x50mm² XLPE Copper Flame Retardant

High Rise Building Main Cable ZR-YJV 4x95mm²+1x50mm² XLPE Copper Flame Retardant Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×95 mm² + 1×50 mm² Four cores of 95 mm² (3 phase + 1 neutral) + one ...

Prev 2 3 4 5 6 Next