"high single strand copper wire"
- 90 Items Found
Fire Retardant Cable Round BTTRZ 4×10 mm² + 1×6 mm² Mineral Insulated Copper Cable
Fire Retardant Cable Round BTTRZ 4×10 mm² + 1×6 mm² Mineral Insulated Copper Cable Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...
25 Mm2 Fire Resistant Cable 4x25mm2+1x16mm2 Mineral Insulated Copper
0.6/1kV Mineral Insulated Cable BTTRZ 4x25mm²+1x16mm² Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV Rated ...
3x400mm2 Medium Voltage Cable XLPE Armored XLPE Wire 26KV 35kV
YJLV22 3x400mm² Aluminum XLPE Armored HV Cable 26/35kV for Urban Power Distribution Cable Designation & Meaning Code Meaning 26/35 kV Rated voltage: U₀ = 26 kV (phase-to-earth), U = 35 kV (phase-to-phase) YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Lü = aluminium) V PVC ...
3*70mm2 Medium High Voltage Power Cable 8.5KV 15Kv Armored For Underground Distribution
3*70mm2 Medium High Voltage Power Cable 8.5KV 15Kv Armored For Underground Distribution Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ XLPE insulation V PVC inner sheath 22 Steel tape armour + PVC outer sheath 8.7/15 kV Rated voltage U₀/U = 8.7 kV / 15 kV 3×70 mm² Three cores ...
High Capacity Mv Armoured Cable 150mm2 XLPE 3 Core Aluminum Cable
High Capacity Aluminum Cable 3 Core 150mm² YJLV22 8.7/10kV Armored XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...
Low Voltage 2 Cores Cable 2 X 10mm2 Stranded Copper Fire Resistant PVC Insulated Sheathed
Low Voltage Power Cable 0.6/1kv YJV-2*10mm² Stranded Copper XLPE Insulation Fire-Resistant PVC Outer Sheath Cable Designation & Meaning Code Meaning ZC Flame retardant C — IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 2×10 mm² Two cores, 10 mm² copper ...
2x16mm2 2 Core Fiber Optic Cable IEC Full Gauge Copper PVC Sheath For Power Engineering
ZR-YJV 2*16mm² Flame Retardant 2 Core Cable,0.6/1kV IEC Standard Full Gauge Copper,XLPE Anti-Aging PVC Sheath for Power Engineering Cable Designation & Meaning Code Meaning ZC Flame retardant C — IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 2×16 mm² Two ...
Polyolefin Single Core Earth Cable ZR-YJV 1 X 35mm2 Single Conductor 0.6/1kV Indoor Power
Polyolefin Single Core Earth Cable ZR-YJV 1 X 35mm2 Single Conductor 0.6/1kV Indoor Power Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 1×35 mm² One core of 35 mm² copper conductor Construction : ...
Copper 4 Cores Cable 3x10mm² + 1x6mm2 For Three Phase Power Wiring
3+1 Core ZR-YJV Flame Retardant Copper Cable 3x10mm²+1x6mm² for Three Phase Power Wiring Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer ...