3*70mm2 Medium High Voltage Power Cable 8.5KV 15Kv Armored For Underground Distribution

3*70mm2 Medium High Voltage Power Cable 8.5KV 15Kv Armored For Underground Distribution

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
ZC-YJV22 3*70mm²

Trading Properties

moq
100 meters
payment method
L/C,T/T
supply capacity
5000 Meters Per Month

Product Summary

3*70mm2 Medium High Voltage Power Cable 8.5KV 15Kv Armored For Underground Distribution Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ XLPE insulation V PVC inner sheath 22 Steel tape armour + PVC outer sheath 8.7/15 kV Rated voltage U₀/U = 8.7 kV / 15 kV 3×70 mm² Three cores ...

Product Details

Highlight:

8.5KV High Voltage Power Cable

,

15Kv High Voltage Power Cable

,

Underground Distribution Armored Power Cable

Conductor:
Class 2 Compacted Stranded Annealed Copper, 70 Mm² → 18/2.32 Mm (or Equivalent Circular Compacted), Conductor Ø ≈ 9.9 Mm
Conductor screen:
Extruded Semi-conductive XLPE-based Layer, ≈ 0.6 Mm
Insulation:
XLPE (cross-linked Polyethylene), Nominal Thickness 4.5 Mm​ (per 8.7/15 KV Class, GB/T 12706.2), Insulation Ø ≈ 20.2 Mm
Insulation screen:
Extruded Semi-conductive Layer + Copper Tape Screen (≈0.1 Mm) Helically Lapped, Bonded To Insulation
Core bedding / fill:
PP Rope Fill, Non-hygroscopic, Round-up To 3-core Assembly
Inner sheath (bedding):
PVC (90 °C Grade, Flame-retardant ZC Type), Nominal ≈ 1.8 Mm
Armour:
Double Galvanised Steel Tape, 2 × 0.5 Mm (total ≈ 1.0 Mm), Reverse-lapped
Outer sheath:
PVC, Flame-retardant Class C (ZC), Black, Nominal Thickness ≈ 3.1 Mm
Overall diameter:
≈ 59–61 Mm​ (maker-dependent, 59.1 Mm Typical)
Weight:
≈ 5 210 – 5 538 Kg/km​ (Cu, With Steel Tape + PVC)
Rated voltage U₀/U:
8.5/15 KV​ (conductor-to-earth / Conductor-to-conductor)
Highest system voltage Uₘ:
17.5 KV​ (per IEC 60038 / IEC 60502-2)
AC withstand (routine):
30.5 KV, 5 Min

Product Description

3*70mm2 Medium High Voltage Power Cable 8.5KV 15Kv Armored For Underground Distribution

Cable Designation & Meaning

Code

Meaning

ZC

Flame retardant Class C 

YJ

XLPE insulation 

V

PVC inner sheath 

22

Steel tape armour + PVC outer sheath 

8.7/15 kV

Rated voltage U₀/U = 8.7 kV / 15 kV

3×70 mm²

Three cores of 70 mm² copper conductor


Construction: Three 70 mm² compacted copper conductors, XLPE insulation on each core, copper tape screen over each core, PVC inner sheath over laid-up cores, steel tape armour, PVC outer sheath.

Applicable Standards

  • GB/T 12706.3-2020 / IEC 60502-2 — Power cables with extruded insulation for rated voltages from 6 kV up to 30 kV
  • GB/T 3956-2008 / IEC 60228 — Conductors of insulated cables (Class 2 compacted circular)
  • GB/T 18380.3 / IEC 60332-3-24 — Flame retardant (Category C)
  • GB/T 2951-2008 / IEC 60811 — Common test methods for insulating and sheathing materials
  • GB/T 3048-2007 — Test methods for electric cables
  • GB/T 19216 — Fire resistance (optional)

3*70mm2 Medium High Voltage Power Cable 8.5KV 15Kv Armored For Underground Distribution

ZC-YJV22 8.7/15 kV 3×70 mm² — Medium-Voltage XLPE Steel-Tape Armoured Power Cable — Specification

1. Overview & Ratings. ZC-YJV22 8.7/15 kV 3×70 is a medium-voltage armoured power cable: three 70 mm² compacted copper cores with a three-layer co-extruded conductor screen + XLPE insulation + insulation screen, cabled triangularly over PVC bedding, double steel-tape armour and a black PVC sheath. Rated 8.7/15 kV, 90 °C XLPE. OD ≈ 58 mm, ≈ 8500 kg/km (est.), ≈ 210 A per core at 30 °C (est.). Class C flame-retardant — an ordinary MV distribution cable, not a 950 °C fire-rated circuit. Scope: 10 kV feeders, ring main units, substation-to-plant supply.


2. Construction Stack (Inner → Outer, expanded).


Layer / Feature Build Function
Conductor (×3) 3×70 compacted Cu, class 2 R ≤0.268 Ω/km @20°C
Conductor screen Extruded semiconducting, ≈0.8 mm Smooths field at conductor
XLPE insulation ≈4.5 mm, 90 °C MV dielectric
Insulation screen Bonded semiconducting Outer field control
Bedding / inner sheath PVC ≈1.5 mm Bed for armour
Double steel-tape armour Two tapes, ≈54 mm Crush/impact protection
PVC outer sheath ≈2.5 mm, black UV Environmental jacket


3. Electrical Characteristics. R ≤0.268 Ω/km @20 °C. Power-frequency withstand 21 kV AC / 5 min; partial discharge ≤10 pC at rated voltage; ≈210 A per core (est.); short-circuit ≈16 kA/1s (est.); lightning impulse type-tested; 50/60 Hz.

Insulation & Sheath Data

Property

Value

Insulation material

XLPE (Cross-linked Polyethylene)

Inner sheath material

PVC (Type ST2)

Outer sheath material

PVC (Type ST2)

Armour material

Steel tape (double layer)

Long-term service temp.

90 °C (continuous)

Max. conductor temp. (normal)

90 °C

Short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Test voltage AC (5 min)

30.5 kV (phase-to-phase)

Partial discharge test

≤ 10 pC at 13 kV

Dielectric strength

≥ 25 kV/mm

Volume resistivity @20 °C

≥ 1×10¹⁵ Ω·cm

Shield

Copper tape screen per core + steel tape armour (earthable)

Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

8.7 / 15 kV

GB/T 12706.3 / IEC 60502-2

Max. system voltage Um

17.5 kV

—

Test voltage AC (5 min)

30.5 kV

Routine test

DC resistance @20 °C

≤ 0.268 Ω/km per core

GB/T 3956 Class 2 Cu max (70 mm²)

AC resistance @90 °C (est.)

≈ 0.34 Ω/km per core

—

Current rating in air (30 °C)

Three-phase AC: 230 A​ (per phase core)

3×70, touching, in free air

Current rating in tray (30 °C)

Three-phase AC: 250 A​ (per phase core)

3×70, spaced

Current rating buried (20 °C, 0.8 m depth)

Three-phase AC: 210 A​ (per phase core)

direct buried, thermal resistivity 1.0 K·m/W

Single-phase current capacity

Single-phase AC: 230 A​ (L-N, if applicable)

—

DC current capacity

230 A​ per core

—

Short-circuit current (1 s, Cu, 250 °C)

≈ 7,700 A per core

—

Capacitance (core-to-screen, approx.)

≈ 0.25 µF/km

XLPE

Inductive reactance (approx.)

≈ 0.10 Ω/km

at 50 Hz

Frequency

50/60 Hz AC

—


Reference values: ZC-YJV22 8.7/15 kV 3×70 at 230 A three-phase, 10 kV → max load ≈ 3.99 MVA​ (cos φ = 1.0). At 15 kV line-to-line → max load ≈ 5.98 MVA​ (cos φ = 1.0). Suitable for medium-voltage power distribution in industrial plants, substations, and underground buried circuits.


4. Thermal & Flame. 90 °C normal, 250 °C short-time; Class C self-extinguishing. It is ordinary MV cable — not fire-survival; choose fire-rated cable for life-safety circuits.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

90 °C (continuous)

Max. short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Min. installation ambient temp.

0 °C (PVC) / −20 °C (with pre-heating)

Service ambient range

−20 °C to +90 °C

Flexing temp. range

0 °C to +90 °C

Fire Performance (ZC-YJV22 — Flame Retardant Class C)

Property

Value / Requirement

Flame retardant

GB/T 18380.3 / IEC 60332-3-24​ (Category C, flame propagation limited)

Flame retardant class

Class C​ (ZC)

Halogen content

Contains halogen (PVC sheath)

Smoke density

Not low-smoke

Corrosivity

Corrosive (PVC)

Toxicity

Toxic fumes when burned

EMI shielding

Steel tape armour provides partial shielding


5. Installation Practice & Handling. Bend ≥ 15×OD ≈ 870 mm; use qualified MV terminations and joints to keep the system PD-free; earth the steel-tape armour at both ends; direct bury, duct or tray; test insulation after pulling.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 15 × OD → ≈ 870 mm at Ø58.0 mm

armoured cable

Max. pulling tension

1,050 N per core (70 mm² × 15 N/mm²)

Cu conductor limit

Direct burial

Suitable​ (steel tape armour protects against mechanical damage)

—

Surface mounting

Cable tray, conduit, trench

—

Trench width

≥ 300 mm

—

Fixing

heavy-duty cable clamps, brackets

—

Impact resistance

High​ (steel tape armour)

—

Water resistance

Limited (PVC sheath)

—

UV resistance

Poor (PVC degrades outdoors, use UV-resistant or conduit)

—

Flex life

Limited (Class 2 compacted, not flexible)

fixed installation only

Termination note

Heat-shrink terminations, cold-shrink terminations, or pre-moulded joints (MV rated)

—


6. Typical Service Applications. 10 kV distribution feeders, ring main units, substation-to-plant MV supply, mines and industrial MV networks.


3*70mm2 Medium High Voltage Power Cable 8.5KV 15Kv Armored For Underground Distribution


7. Testing & QA Regime (16 items). Routine: DC resistance, partial discharge, 21 kV withstand, insulation resistance, conductor construction, insulation/sheath thickness, dimensional check, armour check, print legibility, mass, appearance, packing. Type: flame class, impulse withstand, bending.


Cable Parameters


YJV22-3×70 mm² 8.7/10 kV (and 8.7/15 kV variant) — Full Parameter Sheet 
Medium-voltage power cable · Cu conductor / XLPE insulation / copper-tape screen / double-steel-tape armour (type 22) / PVC outer sheath · per GB/T 12706.2 · 3 cores · finished Ø ≈ 68 mm (10 kV) / ≈ 71 mm (15 kV)
Section Parameter Value Unit Remarks / Standard
01 · Identification

Cable type YJV22 — Cu conductor / XLPE insulation / double-steel-tape armour / PVC outer sheath

Rated voltage (U0/U) 8.7/10 kV AC 50 Hz; Um = 12 kV (10 kV grade)

Alternative voltage grade 8.7/15 kV AC 50 Hz; Um = 17.5 kV (15 kV grade) — thicker XLPE

Number of cores 3 × 70 — 3 phase cores (70 mm²) — no separate neutral in MV cable

Conductor material Annealed copper, compacted stranded — Class 2 stranded per GB/T 3956

Conductor screen Extruded semi-conducting XLPE — Conductor screen layer (radial field control)

Insulation material Cross-linked polyethylene (XLPE) — 90 °C continuous, 250 °C short-circuit

Insulation screen Extruded semi-conducting, strippable — Outer screen layer

Metallic screen Copper tape, lapped — 0.1 × 25 mm Cu tape; equipotential earth

Armour Double galvanised steel tape — Type 22 armour — mechanical protection

Outer sheath PVC (ST2), flame-retardant — UV- and abrasion-resistant

Standard reference GB/T 12706.2 / IEC 60502-2; GB/T 3956 — Medium-voltage power cables 1.8/3 kV to 26/35 kV
02 · Conductor

Stranding — 70 mm² Compacted stranded copper — Class 2, circular compacted

Strand count (typical) 19 × 2.14 mm (or equivalent) — Compacted after stranding

Conductor diameter ≈ 10.5 mm After compacting (est.)

DC resistance @ 20 °C ≤ 0.268 Ω/km Maximum per GB/T 3956 Class 2

AC resistance @ 50 Hz (≈ 90 °C) ≈ 0.35 Ω/km Skin/proximity effect included

Conductor screen thickness ≈ 0.8 mm Extruded semi-conducting layer
03 · Insulation

Insulation type Cross-linked polyethylene (XLPE) — Extruded, triple-layer co-extrusion

Insulation thickness — 8.7/10 kV 4.5 mm Nominal, per GB/T 12706.2

Insulation thickness — 8.7/15 kV 5.5 mm Thicker for 15 kV grade

Core Ø over insulation — 10 kV ≈ 21.1 mm 10.5 + 2×(0.8+4.5+0.8)

Core Ø over insulation screen — 15 kV ≈ 23.1 mm 10.5 + 2×(0.8+5.5+0.8)

Insulation screen thickness ≈ 0.8 mm Strippable semi-conducting

Impulse withstand (BIL) — 10 kV 75 kV Lightning impulse test

Impulse withstand (BIL) — 15 kV 95 kV Lightning impulse test
04 · Metallic Screen & Filler

Screen material Annealed copper tape — Lapped with overlap

Screen tape dimensions 0.1 × 25 mm Two layers lapped (typical)

Screen function Equipotential earth / fault-current path — Earthed at terminations

Filler material PP / jute rope, flame-retardant — Fills interstices for round cable

Bedding / binder tape Semi-conducting or non-woven tape — Holds bundle; anti-corrosion layer

Assembled bundle Ø — 10 kV ≈ 58 mm Before inner sheath (est.)

Assembled bundle Ø — 15 kV ≈ 62 mm Before inner sheath (est.)
05 · Inner Sheath & Armour

Inner sheath / bedding PVC or PE extruded — Corrosion barrier under armour

Inner sheath thickness ≈ 1.5 mm Over bundle

Armour type Double steel tape (type 22) — Double-tape helical armour

Armour tape thickness 2 × 0.5 mm Galvanised steel, lapped

Armour function Mechanical protection against crush / impact — Permits direct burial / tray

Armour diameter — 10 kV ≈ 62 mm Over inner sheath (est.)
06 · Outer Sheath

Jacket material PVC, ST2, flame-retardant — GB/T 12706.1

Jacket thickness 2.5 mm Minimum over armour

Overall finished diameter — 10 kV ≈ 68 mm Cross-referenced industry sample

Overall finished diameter — 15 kV ≈ 71 mm Thicker insulation version

Approx. cable mass — 10 kV ≈ 7200 kg/km Cu + XLPE + steel + PVC

Approx. cable mass — 15 kV ≈ 7400 kg/km Heavier due to thicker insulation

Jacket colour Black (standard) — UV-resistant carbon-black PVC

Mass per 100 m — 10 kV ≈ 720 kg/100 m For drum loading
07 · Electrical

Rated voltage U0/U 8.7/10 kV AC 50 Hz; Um = 12 kV

Maximum system voltage Um (10 kV) 12 kV —

DC resistance @ 20 °C ≤ 0.268 Ω/km 70 mm² Cu Class 2

Insulation resistance ≥ 1000 MΩ·km XLPE at 20 °C

Capacitance (typical) ≈ 0.42 μF/km Per core (est.)

Dissipation factor tan δ (at U0) ≤ 0.001 — XLPE, 20 °C

Routine test voltage (AC) — 10 kV 21.5 kV / 5 min — Power-frequency withstand

Routine test voltage (AC) — 15 kV 30.5 kV / 5 min — Power-frequency withstand

Air ampacity @ 25 °C ≈ 230 A 3 cores loaded, Cu, in free air (est.)

Buried ampacity @ 25 °C soil ≈ 225 A 3 cores loaded, Cu, direct burial (est.)
08 · Thermal & Fire

Max continuous conductor temp. 90 °C Normal service

Short-circuit temp. (≤ 5 s) 250 °C XLPE limit

Fire behaviour Flame-retardant (PVC jacket) — GB/T 18380.34 class A

Service ambient range −20 to +50 °C Fixed installation

Thermal resistance (soil) 1.2 K·m/W Reference burial conditions

Short-circuit rating (1 s) ≈ 10.2 kA 70 mm² Cu at 250 °C
09 · Installation

Min bending radius ≥ 15 × OD ≈ 1020 mm Fixed installation (armoured)

Laying temperature ≥ 0 °C Pre-heat below 0 °C

Laying methods Tray, direct burial, conduit, duct — Armour permits direct burial

Armour earthing Both ends earthed — Steel armour must be earthed

Copper screen earthing At both ends (or single point for cross-bonding) — MV cable screen bonding

Termination / joints Heat-shrink or cold-shrink MV kits — Separable connectors / outdoor terminations

Special tools Cable cutter, crimping tool, torque wrench — MV lugs required
10 · Packing

Standard supply length 500 or 1000 m/drum Custom cut lengths available

Reel / packing type Wooden-steel drum — Sealed ends against moisture

Surface marking YJV22, 8.7/10 kV, 3×70, supplier, year, metre marks — Per GB/T 6995

Storage conditions Dry, covered, −20 to +40 °C — Sealed ends; protect from UV

Transport Drums secured against rolling — Heavy cable, do not drag


Cable Test Parameters


Test Parameters — YJV22-3×70 mm² 8.7/10 kV (and 8.7/15 kV)
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance GB/T 3048.4, 20 °C ≤ 0.268 Ω/km (70 mm² Cu) Routine
2 Power-frequency withstand (routine) 21.5 kV AC, 5 min (10 kV grade) No breakdown Routine
3 Power-frequency withstand (15 kV grade) 30.5 kV AC, 5 min No breakdown Routine
4 Partial discharge test At 1.5 U0 = 13 kV (10 kV grade) ≤ 20 pC at 1.73 U0 Routine
5 Dissipation factor tan δ At U0, 20 °C tan δ ≤ 0.001 Routine
6 Insulation resistance GB/T 3048.5 ≥ 1000 MΩ·km Routine
7 Dimensional check Micrometer / micrometer microscope Insulation ≥ 4.5 mm (10 kV); jacket ≥ 2.5 mm Routine
8 Impulse voltage test (BIL) ±75 kV, 10 impulses (10 kV grade) No breakdown at 75 kV Type
9 Impulse voltage test (15 kV grade) ±95 kV, 10 impulses No breakdown at 95 kV Type
10 Heating cycle / load loss 3 cycles U0 + rated current No damage; tan δ stable Type
11 Bending test 15 × OD mandrel, 3 cycles No damage to insulation or sheath Type
12 Short-circuit temperature test 250 °C, 5 s equivalent No insulation collapse Type
13 Flame propagation GB/T 18380.34 class A No vertical flame spread Type
14 Sheath / armour continuity Continuity meter Steel armour and Cu tape continuous Routine
15 Voltage test after ageing After thermal ageing cycle Withstands 2.5 U0 AC Type
16 Marking legibility Visual + rubbing YJV22 / 8.7/10 kV / 3×70 / metre marks legible Routine


Cable Cross Section Structure


3*70mm2 Medium High Voltage Power Cable 8.5KV 15Kv Armored For Underground Distribution

YJV22-3×70 mm² 8.7/10 kV — Cross-Section Construction Diagram (Schematic)
MV layered build-up: Cu conductor → conductor screen → XLPE insulation → insulation screen → Cu-tape screen → filler → bedding → double-steel-tape armour → PVC jacket · 8.7/10 kV (8.7/15 kV variant noted) · finished Ø ≈ 68 mm
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor (Cu) ×3 Annealed compacted stranded copper, Class 2 — 19×2.14 mm equivalent per core — ≈ 10.5 Power conductor; R ≤ 0.268 Ω/km at 20 °C
2 Conductor screen Extruded semi-conducting XLPE, co-extruded with insulation ≈ 0.8 ≈ 12.1 Eliminates air gaps; smooth radial field
3 XLPE insulation Cross-linked polyethylene, triple-layer co-extrusion 4.5 (10 kV) / 5.5 (15 kV) ≈ 21.1 / ≈ 23.1 Main dielectric; 90 °C continuous
4 Insulation screen Strippable semi-conducting XLPE ≈ 0.8 ≈ 22.7 / ≈ 24.7 Outer screen; equipotential
5 Copper-tape screen Annealed Cu tape, lapped, 0.1 × 25 mm ≈ 0.1 tape ≈ 22.9 / ≈ 24.9 Earth path / fault-current return
6 Filler & bedding PP/PE rope filler + non-woven binder tape — ≈ 58 / ≈ 62 bundle Round shape; anti-corrosion bedding
7 Inner sheath PVC/PE extruded bedding over bundle ≈ 1.5 ≈ 61 / ≈ 65 Corrosion barrier under armour
8 Steel armour (type 22) Double galvanised steel tape, helically lapped 2 × 0.5 ≈ 62 / ≈ 66 Mechanical crush / impact protection
9 PVC outer jacket ST2 PVC, flame-retardant, black 2.5 ≈ 68 / ≈ 71 (finished) UV, abrasion and chemical protection
Key Dimensions & Properties (expanded)
Finished cable diameter (10 kV) ≈ 68 mm Cross-referenced industry sample

Finished cable diameter (15 kV) ≈ 71 mm Thicker XLPE variant

Approx. cable mass (10 kV) ≈ 7200 kg/km Cu + XLPE + steel + PVC

Approx. cable mass (15 kV) ≈ 7400 kg/km Heavier due to thicker insulation

Nominal voltage rating 8.7/10 kV AC 50 Hz; Um = 12 kV

Alternative voltage grade 8.7/15 kV Um = 17.5 kV; 5.5 mm XLPE

Max continuous conductor temp. 90 °C Normal service

Short-circuit temp. (≤5 s) 250 °C XLPE limit

Impulse withstand (BIL) 75 (10 kV) / 95 (15 kV) kV Lightning impulse

Min bending radius ≥ 15 × OD ≈ 1020 mm Fixed installation

DC resistance @ 20 °C ≤ 0.268 Ω/km 70 mm² Cu

Insulation resistance ≥ 1000 MΩ·km XLPE

Routine test voltage 21.5 kV AC / 5 min — 10 kV grade; 30.5 kV for 15 kV

Air ampacity @ 25 °C ≈ 230 A 3 cores loaded, Cu (est.)

Mass per 100 m (10 kV) ≈ 720 kg/100 m For drum loading

Schematic — not to exact scale. Finished Ø ≈ 68 mm (10 kV) and weight ≈ 7200 kg/km from cross-referenced industry samples; conductor/insulation diameters per GB/T 12706.2 and GB/T 3956; ampacity 230 A is an engineering estimate. The 8.7/15 kV variant uses 5.5 mm XLPE insulation, ≈ 71 mm OD and ≈ 7400 kg/km. Values marked (est.) require confirmation against the factory test certificate.


Cable Construction Description


Construction Description — YJV22-3×70 mm² 8.7/10 kV 
Layer-by-layer MV build-up narrative · 8.7/10 kV (and 8.7/15 kV variant) · Cu / triple-extruded XLPE / Cu-tape screen / double-steel-tape armour / PVC jacket · finished Ø ≈ 68 mm
1. Product Identity & Ratings
YJV22-3×70 is a medium-voltage (MV) power cable rated 8.7/10 kV (Um = 12 kV) at 50 Hz, built around three 70 mm² compacted-stranded copper conductors, each with a triple-extruded semi-conducting screen / XLPE insulation / semi-conducting screen system, a lapped copper-tape screen, and an overall double-galvanised-steel-tape armour (type 22) with a black PVC outer jacket. The same construction is also manufactured in the 8.7/15 kV grade (Um = 17.5 kV) with thicker 5.5 mm XLPE insulation. The cable is designed for 10 kV primary distribution feeders serving 1600–2500 kVA distribution transformers and medium-voltage motors in the 400–630 kW range. Finished diameter is about 68 mm (10 kV) and nominal mass about 7200 kg/km (≈ 720 kg per 100 m). With all three cores loaded, the cable carries about 230 A in free air at 25 °C (engineering estimate).
2. Copper Conductor & Screens
Each 70 mm² conductor is compacted-stranded annealed copper (Class 2), with a strand-lay diameter of about 10.5 mm and DC resistance ≤ 0.268 Ω/km at 20 °C. A semi-conducting conductor screen (≈ 0.8 mm) is co-extruded directly over the copper to eliminate air gaps and smooth the electric field — this is essential at MV voltages because even tiny voids cause partial discharge and eventual insulation failure. The conductor screen bonds electrically to the copper conductor.
3. XLPE Insulation
Cross-linked polyethylene (XLPE) is extruded in a triple-layer co-extrusion process: conductor screen → XLPE insulation → insulation screen, all in one pass to avoid contamination. For the 8.7/10 kV grade the insulation thickness is 4.5 mm; for the 8.7/15 kV grade it is 5.5 mm. XLPE sustains 90 °C continuous conductor temperature and 250 °C short-circuit for ≤ 5 s. The outer insulation screen is strippable for termination work. Over the insulation screen a 0.1 × 25 mm copper tape is lapped to provide an equipotential earth and fault-current return path.
4. Bedding, Steel Armour & PVC Jacket
Three screened cores are cabled round with PP/PE rope filler and a non-woven binder tape, giving a bundle of about 58 mm (10 kV). A PVC/PE inner bedding (≈ 1.5 mm) is extruded over the bundle, then a double layer of 0.5 mm galvanised steel tape is helically lapped — this is the type-22 armour that protects against crush and impact and permits direct burial. Finally a 2.5 mm black PVC (ST2) outer jacket is extruded over the armour to the ≈ 68 mm finish, providing UV, abrasion and chemical resistance.
5. Site Handling & Operational Notes
• Observe the 15 × OD minimum bending radius (≈ 1020 mm).  • The steel armour must be earthed at both ends; the copper-tape screen must be bonded per MV practice (both ends or cross-bonded).  • Use heat-shrink or cold-shrink MV termination kits — do not treat as LV cable.  • Service ambient −20 to +50 °C; conductor up to 90 °C continuous.  • Routine test 21.5 kV AC / 5 min (10 kV); impulse withstand 75 kV.  • At ≈ 720 kg/100 m, plan drum jacks and rated pulling gear.


8. Factory Advantages.

  • Three-layer co-extrusion — conductor screen, XLPE and insulation screen built in line for clean field control.
  • Routine PD gate — every length partial-discharge tested to ≤10 pC.
  • Steel-tape armour — crush/impact protection for direct burial and ducts.
  • Class C flame retardant — meets common MV wiring fire rules.
  • XLPE 90 °C — higher ampacity per copper than PVC.
  • Black UV jacket — outdoor stable for tray and exposed runs.
  • Withstand + impulse records — routine and type test evidence.
  • Length-on-drum — cut to the exact MV feeder run.
  • Certified support pack — documentation for distribution tenders.

3*70mm2 Medium High Voltage Power Cable 8.5KV 15Kv Armored For Underground Distribution


9. Packaging, Storage & Logistics. Cut to feeder length on heavy wooden drums with sealed ends; store dry indoor, shaded, avoid UV.


3*70mm2 Medium High Voltage Power Cable 8.5KV 15Kv Armored For Underground Distribution


10. Procurement Specification. State "ZC-YJV22 8.7/15 kV 3×70", length, laying method (bury/duct/tray) and the required MV terminations/joints; request the routine PD/withstand records and type test. Est. values and exact PD/impulse/withstand limits confirmed against the factory type certificate.


11. Cable Industry FAQ.

  • Q1: How is this MV cable different from a 0.6/1 kV YJV? It has a much thicker XLPE wall (≈4.5 mm) plus conductor and insulation semiconducting screens to control the MV electric field, and steel-tape armour — the rating is 8.7/15 kV for 10 kV networks, not 0.6/1 kV.
  • Q2: What are conductor and insulation screens? Semiconducting layers that smooth the electric field at the conductor and at the insulation boundary — essential to avoid partial discharge at MV.
  • Q3: What is the PD test? Partial discharge ≤10 pC at rated voltage; it is the key MV quality gate confirmed on every length.
  • Q4: DC resistance? ≤0.268 Ω/km at 20 °C per 70 mm² copper core.
  • Q5: Is it fire-rated (950 °C)? No — it is Class C flame-retardant self-extinguishing; use a fire-rated cable (e.g. BTTRZ) for life-safety circuits.
  • Q6: Current rating? ≈210 A per core (est.) at 30 °C; derate by laying method and grouping.
  • Q7: Bending? ≈870 mm (15×OD) — armoured MV needs a large bend radius.
  • Q8: What terminations? Qualified MV terminations and joints; ordinary LV joints break the PD-free rating.
  • Q9: Can it be buried? Yes — steel-tape armour suits direct burial, ducts and trays.
  • Q10: Packing? Heavy wooden drums with sealed ends.
  • Q11: What proof ships? Routine PD and withstand records plus the type certificate; est. values confirmed against it.