4x10mm2+1x6mm2 XLPE Copper Cable 0.6kV 1kV Flame Retardant
ZR-YJV 4x10mm²+1x6mm² XLPE Copper Cable 0.6/1kV Flame Retardant Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×10 mm² + 1×6 mm² Four cores of 10 mm² (3 phase + 1 neutral) + one earth core of 6 mm² ...
Copper Core 5 Core Shielded Cable 4x50mm2+1x25mm2 XLPE Flame Retardant 0.6/1kV
Copper Core 4+1 Cable ZR-YJV 4x50mm²+1x25mm² XLPE Flame Retardant 0.6/1kV Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×50 mm² + 1×25 mm² Four cores of 50 mm² (3 phase + 1 neutral) + one earth ...
ZR-YJV 1*240mm² Fire Retardant Single Conductor Cable, 0.6/1kV Pure Copper, XLPE PVC Sheath for Indoor Power Wiring
ZR-YJV 1*240mm² Fire Retardant Single Conductor Cable, 0.6/1kV Pure Copper, XLPE PVC Sheath for Indoor Power Wiring Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Outer Sheathed ZR-YJV 1×240 mm² — Product Briefing 1. What It Is. The ZR-YJV 1×240 is the heavy feeder class of the flame...
ZR-YJV 3x300mm²+1x150mm² XLPE Copper Cable 0.6/1kV Flame Retardant
ZR-YJV 3x300mm²+1x150mm² XLPE Copper Cable 0.6/1kV Flame Retardant Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 3×300 mm² + 1×150 mm² Three phase cores of 300 mm² + one neutral core of 150 mm² ...
RVVP 3x1.5mm2 Braided Copper Shielded Control Cable Stable Signal for Circuits 300/500V
RVVP 3x1.5mm2 Braided Copper Shielded Control Cable Stable Signal for Circuits 300/500V Cable Designation & Meaning Code Meaning R Flexible cord V PVC insulation V PVC sheath P Copper braid shield 3×1.5 mm² Three cores of 1.5 mm² copper conductor Construction : Three 1.5 mm² fine-stranded copper ...
120kg/Km Stranded Copper Wire 4 Core Cable RVV 4x1.5mm2 PVC Flexible Rvv Wire Cable
Stranded Copper 4 Core Cable RVV 4x1.5mm² PVC Flexible 300/500V Cable Designation & Meaning Code Meaning RVV R = Flexible copper conductor (Class 5), V = PVC insulation, V = PVC sheath 300/500 V Rated voltage U₀/U = 300/500 V; Uₘ = 500 V 4×1.5 mm² Four flexible cores, each 1.5 mm² copper conductor ...
5 Core Multi Core Control Cable 0.75mm2 RVV For Building Automation
Multi Core Control Cable 5 Core 0.75mm² RVV for Building Automation Cable Designation & Meaning Code Meaning RVV R = Flexible copper conductor (Class 5), V = PVC insulation, V = PVC sheath 300/500 V Rated voltage U₀/U = 300/500 V; Uₘ = 500 V 5×0.75 mm² Five flexible cores, each 0.75 mm² copper ...
4 Core Industrial Power Cable 10mm2 RVV PVC Flexible Stranded Copper
Industrial Power Cable 4 Core 10mm² RVV PVC Flexible Stranded Copper 300/500V Cable Designation & Meaning Code Meaning RVV R = Flexible copper conductor (Class 5), V = PVC insulation, V = PVC sheath 300/500 V Rated voltage U₀/U = 300/500 V; Uₘ = 500 V 4×10 mm² Four flexible cores, each 10 mm² copper ...
WDZBN-YJY 5 Core 3x50mm²+2x25mm² Low Smoke Halogen Free Fire Resistant XLPE Cable 0.6/1kV
WDZBN-YJY 5 Core 3x50mm²+2x25mm² Low Smoke Halogen Free Fire Resistant XLPE Cable 0.6/1kV Cable Designation & Meaning Code Meaning 0.6/1 kV Rated voltage: U₀ = 0.6 kV (phase-to-earth), U = 1 kV (phase-to-phase) WD Low-smoke, zero-halogen (LSZH) ZB Flame retardant Category B (IEC 60332-3-23, Class B) ...