RVVP 3x1.5mm2 Braided Copper Shielded Control Cable Stable Signal for Circuits 300/500V
Product Summary
Product Details
RVVP 3x1.5mm2 shielded control cable
,braided copper shielded 3 core cable
,300/500V flexible control cable
Product Description
RVVP 3x1.5mm2 Braided Copper Shielded Control Cable Stable Signal for Circuits 300/500V
Cable Designation & Meaning
|
Code |
Meaning |
|---|---|
|
R |
Flexible cord |
|
V |
PVC insulation |
|
V |
PVC sheath |
|
P |
Copper braid shield |
|
3×1.5 mm² |
Three cores of 1.5 mm² copper conductor |
Construction: Three 1.5 mm² fine-stranded copper conductors, PVC insulation on each core, laid up together, tinned copper braid shield (≥80% coverage) over the laid-up cores, PVC outer sheath.
Applicable Standards
- GB/T 5023.5-2008 / IEC 60227-5 — Polyvinyl chloride insulated cables — Flexible cables (cords)
- GB/T 3956-2008 / IEC 60228 — Conductors of insulated cables (Class 5 flexible)
- GB/T 18380.3 / IEC 60332-3 — Flame retardant (Category A/B/C as specified)
- GB/T 5023.2-2008 / IEC 60227-2 — Test methods
RVVP 3×1.0 mm² — Flexible Shielded Signal+Power Cable — Specification
1. Overview & Ratings
RVVP 3×1.5 is a 3-core shielded control+signal cable rated 300/500 V. It uses pure annealed bare copper (not tinned) for both the conductor and braid, maximizing conductivity. The three 1.5 mm² cores are laid up in a triangular formation and handle motor auxiliary circuits, larger solenoid valves, and 3-wire sensors over longer distances. The braid suppresses EMI/RFI from nearby VFDs and motors. OD ≈ 10.0 mm, ≈ 95 kg/km (est.), ≈ 10–13 A. Max conductor temperature 70 °C, -15 to +70 °C. Intended for dry indoor control and signal circuits; for damp or outdoor duty, specify tinned copper variant.
2. Construction Stack (Inner → Outer, expanded)
| Feature | Build | Function |
|---|---|---|
| Conductor (×3) | Pure annealed Cu, Class 5, 30×0.25 mm per core | R ≤ 13.3 Ω/km, control + signal |
| Insulation | PVC ≈ 0.7 mm per core | 300/500 V dielectric, 3-colour coding |
| Inner sheath | PVC + filler ≈ 0.7 mm | Round bedding for triangular core lay |
| Braid shield | Pure Cu, ≈ 85% coverage | Low transfer impedance for control + signal |
| Outer jacket | PVC ≈ 1.0 mm | Robust oil/abrasion protection |
3. Electrical Characteristics
DC resistance ≤ 13.3 Ω/km at 20 °C per GB/T 3956 Class 5 pure copper — roughly 32% lower than 1.0 mm², making it suitable for motor auxiliary and larger solenoid loads. Rated voltage 300/500 V. Estimated ampacity ≈ 10–13 A in free air at 30 °C. Insulation resistance ≥ 20 MΩ·km. Routine AC withstand test at 2000 V for 5 minutes. Typical capacitance ≈ 160 pF/m at 1 kHz. The pure copper braid provides ≈ 60–70 dB shielding at 30–1000 MHz. Voltage drop ≈ 1.33 V per 100 m at 10 A — suitable for 24 V DC motor auxiliary runs up to 50 m.
Insulation & Sheath Data
|
Property |
Value |
|---|---|
|
Insulation material |
PVC (Type TI2) |
|
Outer sheath material |
PVC (Type TM2) |
|
Shield material |
Tinned copper braid |
|
Long-term service temp. |
70 °C (continuous) |
|
Max. conductor temp. (normal) |
70 °C |
|
Short-circuit temp. (≤5 s) |
160 °C |
|
Emergency overload temp. |
100 °C (≤1 h) |
|
Test voltage AC (5 min) |
2.0 kV |
|
Dielectric strength |
≥ 20 kV/mm |
|
Volume resistivity @20 °C |
≥ 1×10¹² Ω·cm |
|
Shield |
Pure copper braid, ≥ 80% coverage (EMI/RFI protection) |
Electrical Parameters
|
Parameter |
Value |
Note |
|---|---|---|
|
Rated voltage U₀/U |
300 / 300 V |
GB/T 5023.5 (control/signal) |
|
Max. system voltage |
350 V AC / 500 V DC |
— |
|
Test voltage AC (5 min) |
2.0 kV |
Routine test |
|
DC resistance @20 °C |
≤ 13.3 Ω/km per core |
GB/T 3956 Class 5 Cu max (1.5 mm²) |
|
AC resistance @70 °C (est.) |
≈ 16.6 Ω/km per core |
— |
|
Current rating in air (30 °C) |
Control/low-power: 10 A per core (recommended max.) |
conservative control rating |
|
Current rating in tray (30 °C) |
Control/low-power: 12 A per core |
— |
|
DC current capacity |
10 A per core |
— |
|
Short-circuit current (1 s, Cu, 160 °C) |
≈ 165 A per core |
— |
|
Capacitance (core-to-core, approx.) |
≈ 0.14 µF/km |
PVC |
|
Capacitance (core-to-shield, approx.) |
≈ 0.22 µF/km |
PVC |
|
Inductive reactance (approx.) |
≈ 0.07 Ω/km |
at 50 Hz |
|
Frequency |
DC / up to 100 MHz (signal) |
— |
|
Characteristic impedance (approx.) |
50 – 70 Ω |
signal reference |
|
Attenuation (at 1 MHz, approx.) |
≈ 0.6 dB/100 m |
— |
Reference values: RVVP 3×1.5 at 10 A per core, 24 V DC → max load ≈ 240 W per core (low-power device supply). At 230 V AC → max load ≈ 2,300 VA per core (not recommended for power).
4. Thermal & Flame Behaviour
Operating range -15 to +70 °C continuous. Short-circuit withstand up to 160 °C for ≤ 5 seconds. PVC insulation and jacket are flame-retardant per IEC 60332-1. The cable is halogen-containing (PVC), emitting HCl gas on burning — avoid in enclosed switchrooms. For public or enclosed spaces, specify LSZH alternatives. The 1.0 mm Type ST jacket is oil- and abrasion-resistant for machine and panel wiring. Note: bare pure copper oxidizes in humid environments — install in dry indoor or conduit-protected locations. UV resistance is limited.
Temperature Characteristics
|
Property |
Value |
|---|---|
|
Max. conductor operating temp. |
70 °C (continuous) |
|
Max. short-circuit temp. (≤5 s) |
160 °C |
|
Emergency overload temp. |
100 °C (≤1 h) |
|
Min. installation ambient temp. |
−15 °C |
|
Service ambient range |
−15 °C to +70 °C |
|
Flexing temp. range |
−5 °C to +70 °C |
Fire Performance (RVVP — PVC, Non-Low-Smoke)
|
Property |
Value / Requirement |
|---|---|
|
Flame retardant |
GB/T 18380.3 / IEC 60332-3 (Category A/B/C as specified) |
|
Halogen content |
Contains halogen (PVC) |
|
Smoke density |
Not low-smoke (IEC 61034-2 not applicable) |
|
Corrosivity |
Corrosive (HCl emission from PVC) |
|
Toxicity |
Toxic fumes when burned (CO, HCl) |
|
EMI shielding |
Excellent (tinned copper braid, ≥85% coverage) |
|
UV resistance |
Poor (PVC degrades outdoors, use conduit or UV-resistant) |
|
Water resistance |
Limited (PVC sheath) |
5. Installation Practice & Handling
Minimum bending radius ≥ 6×OD ≈ 60 mm for fixed installation; 12×OD ≈ 120 mm for drag-chain applications. The 10.0 mm OD and 95 kg/km make the cable robust yet flexible for routing in control panels, through conduits and along machine frames. When terminating, connect the braid shield to earth at one end (or both ends per system design) using a shield gland or drain wire. Use ferrules on the 30-strand conductors. Route the cable away from high-power motor cables by at least 250 mm. After installation, verify insulation resistance, shield continuity and 3-wire polarity before energizing.
Mechanical & Installation Parameters
|
Parameter |
Value |
Remarks |
|---|---|---|
|
Minimum bending radius |
≥ 6 × OD → ≈ 54 mm at Ø9.0 mm |
flexible cable |
|
Max. pulling tension |
22.5 N per core (1.5 mm² × 15 N/mm²) |
Cu conductor limit |
|
Direct burial |
Not recommended (PVC, non-UV, water ingress) |
— |
|
Surface mounting |
Cable tray, conduit, trunking, DIN rail |
— |
|
Conduit ID |
≥ 25 mm |
— |
|
Fixing |
cable ties, clamps, clips |
— |
|
Impact resistance |
Low (PVC) |
— |
|
Water resistance |
Limited (PVC sheath) |
— |
|
UV resistance |
Poor (indoor/conduit only) |
— |
|
Flex life |
Excellent (Class 5 fine-stranded) |
flexible routing |
|
Termination note |
Screw terminals, compression lugs, IDC connectors |
— |
6. Typical Service Applications
Motor auxiliary circuits (brake, encoder, thermal sensor), larger solenoid valve and actuator power, 3-wire pressure and temperature sensors over longer runs (30–50 m), PLC I/O control wiring with auxiliary power, and interconnection between control panels and field instruments. The 1.5 mm² cross-section carries enough current for motor brake coils and larger solenoids while the braid shield suppresses EMI from nearby VFDs and servo drives. Particularly suitable for packaging machines, textile machinery, and production lines where motor control and signal circuits share the same cable. Not for: mains AC power distribution, high-speed fieldbus, direct burial, or outdoor UV-exposed runs.

7. Testing & Quality Assurance Regime
Routine tests (100% production): DC resistance, AC voltage withstand (2000 V/5 min), insulation resistance, conductor construction, wall thickness, dimensional check, print legibility, mass per length, visual appearance, and packing. Type tests (per batch / material change): shield coverage, heat aging (100 °C/7 days), cold bend (-15 °C), jacket tensile, flame retardancy, and shielding effectiveness. Every coil ships with mill test certificate, ROHS and REACH declarations. The 300/500 V rating uses a 2000 V withstand test.
Cable Parameters
| RVVP 3×1.5 mm² — Full Parameter Sheet | ||||
| Shielded flexible control+signal cable · 300/500 V · pure annealed Cu Class 5 · PVC insulation/jacket · pure Cu braid ≈ 85% · 3-core triangular lay-up · GB/T 9330 / IEC 60227 | ||||
| Section | Parameter | Value | Unit | Remarks / Standard |
| 01 · Identification | ||||
| Cable type | RVVP | — | Flexible pure Cu, PVC ins., PVC jacket, braid shield | |
| Rated voltage (U0/U) | 300/500 | V | Control / signal / motor auxiliary | |
| Number of cores | 3 | — | 3 cores, triangular lay-up, colour-coded | |
| Nominal cross-section | 1.5 | mm² | Per core, Class 5 flexible | |
| Conductor material | Pure annealed copper (bare) | — | Class 5 per GB/T 3956, not tinned | |
| Insulation material | PVC (Type SP) | — | 70 °C rated, 0.7 mm wall | |
| Shield | Pure copper braid | — | ≈ 85% coverage, low transfer impedance | |
| Outer jacket material | PVC (Type ST) | — | Oil/abrasion resistant, 1.0 mm | |
| Standard reference | GB/T 9330 / IEC 60227 / UL 2464 | — | Harmonized control cable | |
| 02 · Conductor | ||||
| Stranding | 30 × 0.25 mm | — | Class 5 pure copper per core | |
| Conductor diameter | ≈ 1.55 | mm | Per core, strand-lay | |
| DC resistance @ 20 °C | ≤ 13.3 | Ω/km | Maximum per GB/T 3956 (pure Cu) | |
| Conductor surface | Bare pure copper | — | Not tinned; for dry indoor use | |
| 03 · Insulation | ||||
| Insulation type | PVC (Type SP) | — | Soft PVC, 70 °C | |
| Insulation thickness | ≈ 0.7 | mm | Nominal | |
| Insulated core Ø | ≈ 3.0 | mm | Per core | |
| Insulation resistance | ≥ 20 | MΩ·km | At 20 °C | |
| 04 · Shield & Inner Sheath | ||||
| Inner sheath material | PVC + polyester filler | — | Bedding over triangular core lay | |
| Inner sheath thickness | ≈ 0.7 | mm | Nominal | |
| Shield type | Pure Cu braid | — | Woven over inner sheath | |
| Shield coverage | ≈ 85 | % | Typical | |
| Shielding effectiveness | ≈ 60–70 | dB | At 30–1000 MHz | |
| 05 · Outer Jacket | ||||
| Jacket material | PVC (Type ST) | — | Oil/abrasion resistant | |
| Jacket thickness | ≈ 1.0 | mm | Nominal | |
| Overall finished diameter | ≈ 10.0 | mm | 3-core shielded control+signal | |
| Approximate cable mass | ≈ 95 | kg/km | Pure Cu + PVC + braid | |
| Mass per 100 m | ≈ 9.5 | kg/100 m | For coil loading | |
| 06 · Electrical | ||||
| Rated voltage | 300/500 | V | Control / signal | |
| Test voltage (AC) | 2000 | V AC | 5 min routine | |
| DC resistance @ 20 °C | ≤ 13.3 | Ω/km | Per GB/T 3956 (pure Cu) | |
| Ampacity (free air) | ≈ 10–13 | A | 1.5 mm², 70 °C | |
| Voltage drop @ 10 A / 100 m | ≈ 1.33 | V | I × R | |
| Capacitance (core-core) | ≈ 160 | pF/m | At 1 kHz | |
| 07 · Thermal & Mechanical | ||||
| Max continuous conductor temp. | 70 | °C | Normal service | |
| Short-circuit temp. (≤5 s) | 160 | °C | Copper limit | |
| Min. ambient temp. | -15 | °C | Fixed installation | |
| Min. bending radius | ≥ 6 × OD ≈ 60 | mm | Fixed; 12× for moving | |
| Halogen content | Halogen-containing | — | PVC compound | |
| 08 · Flame & Environment | ||||
| Flame retardancy | IEC 60332-1 | — | Single vertical flame | |
| Oil resistance | Good | — | Type ST PVC | |
| UV resistance | Limited | — | Indoor / conduit use | |
| Corrosion resistance | Limited (bare Cu) | — | Dry indoor only; use tinned for damp/outdoor | |
| ROHS / REACH | Compliant | — | EU 2011/65/EU | |
Cable Test Parameters
| Test Parameters — RVVP 3×1.5 mm² | ||||
| No. | Test Item | Test Condition / Method | Requirement | Type |
| 1 | Conductor DC resistance | GB/T 3956, 20 °C | ≤ 13.3 Ω/km | Routine |
| 2 | AC voltage withstand | 2000 V AC, 5 min | No breakdown | Routine |
| 3 | Insulation resistance | 500 V megohmmeter | ≥ 20 MΩ·km | Routine |
| 4 | Conductor construction | Visual + strand count | 30 × 0.25 mm pure Cu per core | Routine |
| 5 | Wall thickness | Micrometer cross-section | Ins. ≈ 0.7 mm; jacket ≈ 1.0 mm | Routine |
| 6 | Dimensional check | Caliper | OD ≈ 10.0 mm | Routine |
| 7 | Print legibility | Visual + rubbing | Marks legible | Routine |
| 8 | Mass per unit length | Weighing | ≈ 95 kg/km | Routine |
| 9 | Appearance | Visual | Smooth, no blisters | Routine |
| 10 | Packing | Visual | Coil, sealed ends, labelled | Routine |
| 11 | Shield coverage | Unwrap + count | ≥ 80% (≈ 85%) | Type |
| 12 | Heat aging test | 7 days at 100 °C | Retention ≥ 70% | Type |
| 13 | Cold bend test | -15 °C, 4 h mandrel | No cracking | Type |
| 14 | Jacket tensile test | Universal tester | Meets GB/T 9330 min. | Type |
| 15 | Flame retardancy | IEC 60332-1 | Self-extinguish | Type |
| 16 | Shielding effectiveness | Triaxial / open-field | ≥ 60 dB at 30–1000 MHz | Type |
Cable Cross Section Structure

| RVVP 3×1.5 mm² — Cross-Section Construction Diagram (Schematic) | |||||
| Layered build-up: pure copper Class 5 conductors (3 cores) → PVC insulation → inner PVC sheath → pure copper braid shield → PVC outer jacket · 300/500 V shielded control+signal cable · motor auxiliary / larger solenoids / 3-wire sensors · EMI/RFI protection · -15~+70 °C | |||||
| No. | Layer | Material / Construction | Nominal Thickness (mm) | Diameter (mm) | Function / Remarks |
| 1 | Conductor (×3) | Pure annealed copper, Class 5 flexible — 30 × 0.25 mm strands per core | — | ≈ 1.55 (per core) | Control + signal; R ≤ 13.3 Ω/km; bare pure copper for high conductivity |
| 2 | Insulation (per core) | PVC compound (Type SP), extruded over each conductor, colour-coded | ≈ 0.7 | ≈ 3.0 (per insulated core) | Electrical insulation; 300/500 V rated; colour-coded for 3-wire identification |
| 3 | Inner sheath | PVC compound, extruded over the three laid-up cores, round filler | ≈ 0.7 | ≈ 8.0 (before braid) | Round and bed the triangular core lay; mechanical protection; bedding for braid |
| 4 | Braid shield | Pure copper wire braid, ≈ 85% coverage, laid over inner sheath | ≈ 0.45 (effective) | ≈ 9.0 | EMI/RFI shielding; low transfer impedance for control + signal circuits |
| 5 | Outer jacket | PVC compound (Type ST), black or grey, extruded over braid | ≈ 1.0 | ≈ 10.0 (finished) | Outer mechanical protection; oil-, abrasion-resistant; printed markings |
| Key Dimensions & Properties (expanded) | |||||
| Finished cable diameter | ≈ 10.0 | mm | 3-core shielded control+signal cable (est.) | ||
| Approximate cable mass | ≈ 95 | kg/km | Pure Cu + PVC + braid build-up | ||
| Nominal voltage rating | 300/500 | V | Control / signal / motor auxiliary | ||
| Max continuous conductor temp. | 70 | °C | Normal service | ||
| Min. ambient / installation temp. | -15 | °C | Fixed installation | ||
| DC resistance @ 20 °C | ≤ 13.3 | Ω/km | Class 5 pure copper, GB/T 3956 | ||
| Core count × cross-section | 3 × 1.5 | mm² | 3 cores, triangular lay-up | ||
| Shield coverage | ≈ 85 | % | Pure copper braid | ||
| Insulation resistance | ≥ 20 | MΩ·km | PVC at 20 °C | ||
| Test voltage (AC) | 2000 V AC / 5 min | — | Routine withstand test | ||
| Flame retardancy | IEC 60332-1 | — | Single vertical flame | ||
| Shielding effectiveness | ≈ 60–70 | dB | At 30–1000 MHz | ||
| Jacket colour | Black / grey / custom | — | Standard: black | ||
| Mass per 100 m | ≈ 9.5 | kg/100 m | For coil / drum loading | ||
| Reference standard | GB/T 9330 / IEC 60227 / UL 2464 | — | Harmonized control cable | ||
| Schematic — not to exact scale. Finished Ø ≈ 10.0 mm and weight ≈ 95 kg/km from cross-referenced industry samples; conductor stranding 30/0.25 mm per core, 3-core triangular lay-up, and braid coverage ≈ 85%. Pure copper (not tinned) for maximum conductivity. Est. values confirmed against factory type certificate. | |||||
Construction Description
| Construction Description — RVVP 3×1.5 mm² | |||
| Layer-by-layer build-up narrative · 300/500 V shielded control+signal cable · GB/T 9330 / IEC 60227 · pure annealed copper / PVC insulation / pure copper braid shield / PVC outer jacket | |||
| 1. Product Identity & Ratings | |||
| RVVP 3×1.5 is a 3-core shielded control+signal cable rated 300/500 V. It uses pure annealed copper (not tinned) for both the conductor and braid, maximizing conductivity. The three 1.5 mm² cores are laid up in a triangular formation and handle motor auxiliary circuits, larger solenoid valves, and 3-wire sensors over longer distances. OD ≈ 10.0 mm, ≈ 95 kg/km. Max 70 °C, -15 to +70 °C. For dry indoor use; specify tinned variant for damp/outdoor. | |||
| 2. Pure Copper Conductor (×3) | |||
| Each 1.5 mm² core is stranded from 30 pure annealed copper wires of 0.25 mm in a Class 5 flexible lay-up. Pure copper (bare, not tinned) delivers the highest conductivity: DC resistance ≤ 13.3 Ω/km at 20 °C — roughly 32% lower than 1.0 mm², making it suitable for motor auxiliary and larger solenoid loads. The 30-wire stranding keeps the cable flexible for panel dressing. | |||
| 3. PVC Insulation | |||
| Each conductor receives a 0.7 mm Type SP PVC extrusion, colour-coded for 3-wire identification — typically brown/blue/yellow-green or red/black/white. The thicker 0.7 mm wall (vs 0.6 mm on smaller sizes) provides extra dielectric margin for motor auxiliary circuits. Insulation resistance ≥ 20 MΩ·km. | |||
| 4. Inner Sheath + Braid Shield | |||
| The three insulated cores are laid up in a triangular formation with round fillers to keep the cable round, then bedded with a 0.7 mm PVC inner sheath. Over this, a pure copper braid is woven at ≈ 85% coverage. The braid provides EMI/RFI shielding for motor auxiliary circuits and sensitive signals, diverting interference to ground through the shield drain. | |||
| 5. Outer PVC Jacket | |||
| A 1.0 mm Type ST PVC jacket completes the build, yielding an OD of ≈ 10.0 mm — a step up from the 1.0 mm² version to match the larger core. The jacket is oil- and abrasion-resistant, flame-retardant per IEC 60332-1, and printed with product type, cross-section, voltage, metre mark and manufacturer. For drag-chain duty, specify RVVSP variant. |
8. Factory Advantages
Pure annealed copper conductor at 30×0.25 mm stranding delivers maximum conductivity with Class 5 flexibility. Lower DC resistance (13.3 vs 19.5 Ω/km) supports motor auxiliary and longer runs. 0.7 mm insulation and 1.0 mm jacket provide robust dielectric and mechanical protection. Pure copper braid at ≈ 85% coverage provides low transfer impedance. 3-core triangular lay-up combines control, signal and ground in one cable. Colour-coded cores prevent wiring errors. 100% routine electrical QA on every reel. Cut-to-length on coils with sealed ends. Full traceability with MTC and certification support for industrial machinery tenders.

9. Packaging, Storage & Logistics
Cut to customer-specified length on export-grade coils, with both ends heat-sealed to prevent moisture ingress. Coils wrapped in waterproof film and corrugated cardboard, labelled with product type, core count, cross-section, length, weight, production date and reel number. Standard lengths 100/200/500/1000 m. Store dry indoor, -10 to +40 °C, below 75% RH, away from direct sunlight and chemical solvents. FOB Shanghai/Nanjing/Qingdao; CIF and DAP available. Sample lead time 5–7 days; bulk production 15–25 days.

10. Procurement Specification
State cable designation "RVVP 3×1.5 pure copper", required length per coil, and core colour preference (e.g. brown/blue/yellow-green). Request the routine AC withstand test record (2000 V) and shield coverage certificate for the specific batch. Note that this is a pure copper (bare) control+signal variant for dry indoor use — for damp or outdoor applications, specify the tinned copper variant. Specify any regional certification requirements (UL 2464, CE, etc.) at order time. Payment: 30% T/T deposit, balance against B/L copy. Documents: MTC, ROHS/REACH, COO, commercial invoice, packing list.
11. Cable Industry FAQ
Q1: Why choose 1.5 mm² over 1.0 mm²? Lower DC resistance (13.3 vs 19.5 Ω/km), higher ampacity (10–13 A vs 6–8 A), and enough current for motor brake coils and larger solenoid valves.
Q2: Can it power motor brake coils? Yes — the 1.5 mm² core can carry 10–13 A, enough for typical motor brake coils and larger solenoid valves while the other two cores handle signal and ground.
Q3: How long can the control run be? At 24 V DC and 10 A load, voltage drop is ≈ 1.33 V per 100 m — suitable for runs up to 50 m with acceptable voltage loss.
Q4: What is the voltage rating? 300/500 V, suitable for low-voltage control and signal circuits.
Q5: Why pure copper instead of tinned? Bare pure copper has higher conductivity than tinned copper, ideal for control and signal circuits where every ohm matters.
Q6: Is it suitable for outdoor use? No — limited UV resistance and bare copper oxidize in humidity. Use indoors or in UV-protected conduits.
Q7: How do you ground the shield? Connect braid to earth at one end (or both ends per system design) using a shield gland or drain wire.
Q8: What is the bending radius? ≥ 6×OD ≈ 60 mm for fixed; 12× for moving applications.
Q9: What is the temperature range? -15 to +70 °C continuous.
Q10: What proof ships? Routine AC test record (2000 V) + shield coverage certificate + MTC.
Q11: When should I step up to 3×2.5? For larger motor circuits, longer runs (50+ m), or higher current loads (15+ A), step up to RVVP 3×2.5 mm².