RVVP 2x0.75mm² Shielded Signal Cable Braided Copper Low Noise Communication Wire 300/500V

RVVP 2x0.75mm² Shielded Signal Cable Braided Copper Low Noise Communication Wire 300/500V

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
RVVP 2x0.75mm²

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
100000 meters per month

Product Summary

RVVP 2x0.75mm² Shielded Signal Cable Braided Copper Low Noise Communication Wire 300/500V Cable Designation & Meaning Code Meaning R Flexible conductor (Class 5 fine-stranded) V PVC insulation V PVC sheath P Copper wire shield (braid or braid+aluminium foil) 2×0.75 mm² Two cores, each 0.75 mm² ...

Product Details

Conductor (×2):
Copper, Class 5 Fine-stranded Flexible, Nominal 24×∅0.20 Mm (0.75 Mm² Per Core), Conductor Ø ≈ 1.2–1.5 Mm
Insulation (per core):
PVC (polyvinyl Chloride)​ Compound, Nominal Thickness 0.6 Mm, Colour: Red​ (signal/power +) And Black​ (signal/power −) Or As Specified
Lay-up:
Two Cores Twisted Together With PVC Filler To Form Round Core Bundle
Shield:
Copper Wire Braid, Coverage 80% (typical), Or Copper Braid + Aluminium Polyester Tape (optional)
Outer sheath:
PVC (polyvinyl Chloride)​ Compound, Nominal Thickness 0.9 Mm (typical), Colour: Grey​ Or Black​ (round Profile)
Conductor nominal area:
0.75 Mm² (Cu)
Number of cores:
2
Conductor material:
Copper (Cu)
Conductor class:
Class 5 Fine-stranded Flexible
Conductor construction:
24×∅0.20 Mm (typical)
Conductor diameter (approx.):
1.2–1.5 Mm
Insulation thickness (per core):
0.6 Mm
Shield coverage:
80%
Outer sheath thickness:
0.9 Mm
Overall cable diameter:
6.0 – 7.5 Mm
Design outer diameter:
≈ 6.8 Mm
Approx. weight:
0.055 – 0.075 Kg/m (55–75 Kg/km)
Design weight:
≈ 65 Kg/km
Cable shape:
Round

Product Description

RVVP 2x0.75mm² Shielded Signal Cable Braided Copper Low Noise Communication Wire 300/500V

Cable Designation & Meaning

Code

Meaning

R

Flexible conductor (Class 5 fine-stranded)

V

PVC insulation

V

PVC sheath

P

Copper wire shield (braid or braid+aluminium foil)

2×0.75 mm²

Two cores, each 0.75 mm² copper


Construction: Two fine-stranded flexible copper conductors, each PVC insulated, laid up with fillers to form a round core assembly, wrapped with copper braid shield (typically 85%–90% coverage), and extruded with a common round PVC outer sheath.

Applicable Standards

  • JB/T 8734.5-2016 — Rated voltages up to and including 450/750 V PVC insulated cables and cords for fixed wiring and flexible applications — Part 5: Shielded flexible cables
  • GB/T 5023.5-2008 / IEC 60227-5 — Polyvinyl chloride insulated cables — Flexible cables (cords)
  • GB/T 3956 / IEC 60228 — Conductors (Class 5 flexible copper)
  • GB/T 2951 / IEC 60811 — Insulating and sheathing materials — Common test methods
  • GB/T 18380 / IEC 60332-1 — Flame retardant (single cable, passes)
  • GB/T 5441 — Communication cable test methods (shielding effectiveness reference)

RVVP 2x0.75mm² Shielded Signal Cable Braided Copper Low Noise Communication Wire 300/500V


RVVP 2×0.75 mm² — Miniature Shielded Flexible PVC Control Cable — Specification & Engineering Data

1. Overview & Ratings. RVVP 2×0.75 is a miniature shielded flexible PVC control cable rated 300/500 V, 70 °C continuous. Built per GB/T 9330 / IEC 60227. Two 0.75 mm² very fine-stranded copper conductors (~24×0.20 mm) enclosed in a copper wire braid shield (≥ 80% coverage) and PVC outer sheath. Designed for low-level sensor and signal circuits. Finished OD ≈ 6.0 mm, ≈ 65 kg/km, 100 m coils.


2. Construction Stack (Conductor → Outer).

Layer Build Wall Diameter
Conductors (×2) Very fine-stranded annealed Cu, Class 5, 2×0.75 mm² — ≈ 1.1 mm each
PVC insulation Polyvinyl chloride, per core ≈ 0.6 mm ≈ 2.3 mm each
Copper braid shield Tinned copper wire braid, ≥ 80% coverage ≈ 0.4 mm ≈ 5.0 mm
PVC outer sheath PVC, dark/black ≈ 1.0 mm ≈ 6.0 mm (finished)


3. Electrical Characteristics. DC resistance ≤ 24.5 Ω/km at 20 °C (flexible Cu 0.75 mm²); test voltage 2.0 kV AC / 5 min; insulation resistance ≥ 20 MΩ·km. Shield resistance ≤ 20 Ω/km. Nominal ampacity ≈ 7 A (low-power signal). Mutual capacitance ≤ 200 pF/m.

Insulation & Sheath Data

Property

Value

Insulation material

PVC (polyvinyl chloride), Type TI1/TI2

Outer sheath material

PVC (polyvinyl chloride), Type TM1/TM2

Long-term service temp.

70 °C (continuous, both insulation & sheath)

Short-circuit temp. (≤5 s)

160 °C (Cu conductor limit for PVC)

Emergency overload temp.

105 °C (short term)

Test voltage AC (5 min)

2.0 kV (routine test, 300/500 V class)

Dielectric strength

≥ 15 kV/mm (room temp.)

Shielding effectiveness

≥ 60 dB at 30 MHz – 100 MHz (typical copper braid)

Transfer impedance

≤ 100 mΩ/m at 10 MHz (typical)


Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

300 / 500 V

JB/T 8734.5 / GB/T 5023.5

Max. system voltage

500 V AC

—

Test voltage AC (5 min)

2.0 kV

Routine test (core-to-core, core-to-shield)

DC resistance @20 °C

≤ 26.0 Ω/km

GB/T 3956 Class 5 Cu max, 0.75 mm²

AC resistance @70 °C (est.)

≈ 33.0 Ω/km

per core

Current rating in air (30 °C)

7 A​

2-core, open air, reference value

Current rating in tray (30 °C)

6 A​

bundled with other cables

Current rating in conduit (30 °C)

5 A​

enclosed

Short-circuit current (1 s, Cu, 160 °C)

≈ 0.085 kA (85 A)

0.75 mm² Cu

Capacitance (core-to-core, approx.)

≈ 110 pF/m

PVC insulation

Capacitance (core-to-shield, approx.)

≈ 160 pF/m

collective shield

Inductive reactance (approx.)

≈ 0.08 Ω/km

at 50 Hz

Frequency

50/60 Hz AC (signal up to ~10 MHz)

—



Reference values: 2×0.75 mm² at 5–7 A, single-phase 230 V → max load ≈ 1.15–1.6 kW. Primarily intended for signal and low-current control​ (mA to ~1 A levels), not power distribution.


4. Thermal & Mechanical. 70 °C continuous; 160 °C short-circuit (≤ 5 s); ambient −15~+70 °C. Bend ≥ 6 × OD ≈ 36 mm. The extremely fine stranding gives excellent flexibility for tight routing.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

70 °C (continuous)

Max. short-circuit temp. (≤5 s)

160 °C (Cu conductor, PVC limit)

Emergency overload temp.

105 °C (not recommended for continuous)

Min. installation ambient temp.

0 °C (PVC); below 0 °C pre-heating required

Service ambient range

−15 °C to +70 °C (PVC insulation & sheath)

Flexing temp. range

+5 °C to +70 °C (recommended for repeated bending)

Fire survival

Standard (flame retardant single cable)


Fire Performance (RVVP — Standard)

Property

Value / Requirement

Flame retardant

IEC 60332-1 (single cable, passes)

Halogen content

Contains halogen (PVC insulation & sheath)

Smoke density

Standard (non-low-smoke)

Corrosivity

Corrosive (PVC)

Fire survival (circuit integrity)

Not applicable (standard version)

EMI shielding

Yes​ (copper braid, 85%–90% coverage)


RVVP 2x0.75mm² Shielded Signal Cable Braided Copper Low Noise Communication Wire 300/500V

Shielding Performance

Parameter

Value

Note

Shield type

Copper wire braid (bare or tinned)

—

Coverage

85%–90% (typical)

>90% available on request

Optional

Copper braid + aluminium polyester tape (dual shield)

for high EMI environments

Drain wire

Not required (braid is continuous)

—

Shielding effectiveness

≥ 60 dB @ 30–100 MHz

typical braid

Transfer impedance

≤ 100 mΩ/m @ 10 MHz

—

Application

EMI/RFI protection for signal and control circuits

—


RVVP 2x0.75mm² Shielded Signal Cable Braided Copper Low Noise Communication Wire 300/500V


5. Installation Practice & Handling. Use micro-connectors and small crimp ferrules. Ground shield at one or both ends. At 65 kg/km, very light — half the weight of RVVP 2×2.5. Indoor use. Low-power signal only.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 6 × OD → ≈ 41 mm at Ø6.8 mm

flexible conductor, shielded

Max. pulling tension

60 N

fine-stranded Cu (handle gently)

Direct burial

Not recommended​ (no mechanical protection; use conduit)

—

Surface mounting

Good (round profile, cable ties or clips)

—

Conduit ID

≥ 12 mm

—

Fixing

cable ties, clamps, trunking

—

Impact resistance

Low (PVC sheath only)

protect with conduit in exposed areas

Water resistance

Moisture-resistant (PVC)

not waterproof

UV resistance

Poor (PVC degrades in sunlight)

indoor use only

Flex life

High​ (Class 5 fine-stranded, designed for occasional flexing)

—

Termination note

Strip sheath, fold braid back over outer sheath, use heat-shrink or copper strap for shield termination; ferrules recommended for fine-stranded conductors

shield must be grounded at one end (or both, depending on application)


6. Typical Service Applications. Sensor leads, microphone/audio cables, data lines, alarm circuits, micro-control interconnection — anywhere microvolt-level signals must be protected from electromagnetic noise in confined spaces.


RVVP 2x0.75mm² Shielded Signal Cable Braided Copper Low Noise Communication Wire 300/500V


7. Testing & QA Regime. Routine: conductor DC resistance, 2.0 kV AC withstand, insulation resistance, shield coverage check, dimensional check. Type: heating test, repeated bending test, flame retardancy, mutual capacitance measurement.


Cable Parameters

RVVP 2×0.75 mm² — Miniature Shielded Flexible PVC Control Cable — Full Parameter Sheet
Miniature shielded · 2× thin flexible Cu / PVC insulation / copper braid shield / PVC sheath · 300/500 V · 70 °C · ≈ 6.0 mm · low-power signal
Section Parameter Value Unit Remarks / Standard
01 · Identification

Cable type RVVP — miniature shielded flexible PVC control cable — Signal / low-power

Rated voltage (U0/U) 300/500 V Signal / control

Number of cores 2 × 0.75 — 2-core

Conductor material Annealed copper, fine-stranded — Class 5 flexible

Insulation material PVC (polyvinyl chloride) — Per core

Shield type Copper wire braid (P) — ≥ 80% coverage

Sheath material PVC (outer, dark) — Flexible

Standard GB/T 9330 / IEC 60227 — Control cable

Application Low-level signal, sensor, audio, data transmission — Miniature
02 · Conductor (Flexible Cu)

Conductor type Fine-stranded annealed copper — Class 5 flexible

Conductor area 2 × 0.75 mm² 2-core miniature

Stranding construction ≈ 24 × 0.20 mm (approx.) — Very fine

DC resistance @ 20 °C ≤ 24.5 Ω/km Cu 0.75 mm² flexible

Conductor weight per km ≈ 14 kg/km 2×0.75 Cu

Conductor diameter ≈ 1.1 mm Very thin
03 · Insulation & Shield

Insulation type PVC (per core) — General-purpose

Insulation thickness ≈ 0.6 mm 300/500 V

Insulated core OD ≈ 2.3 mm Per core

Shield type Copper wire braid — P = shield

Shield coverage ≥ 80 % EMI protection

Shield diameter ≈ 5.0 mm Over cores
04 · Sheath

Sheath type PVC outer sheath — Flexible

Sheath thickness ≈ 1.0 mm Miniature

Finished outer diameter ≈ 6.0 mm Overall

Sheath color Dark / black — Standard
05 · Electrical

Rated voltage (U0/U) 300/500 V Signal / control

Max voltage 500 V Phase-to-phase

DC resistance @ 20 °C ≤ 24.5 Ω/km Flexible Cu 0.75

Test voltage (AC) 2.0 kV / 5 min — Routine

Insulation resistance ≥ 20 MΩ·km PVC

Nominal current (ampacity) ≈ 7 A Low-power signal

Shield resistance ≤ 20 Ω/km Braid shield
06 · Thermal

Max conductor temp. 70 °C PVC rated

Short-circuit temp. 160 °C Max 5 s

Ambient range -15 ~ +70 °C Indoor

Laying temperature ≥ -10 °C Flexible
07 · Mechanical & Shield

Min bending radius (fixed) ≥ 6 × OD ≈ 36 mm Miniature

Flexibility Excellent — Very fine strands

Shield attenuation EMI/RFI protected — Copper braid

Cable weight per km ≈ 65 kg/km Very light
08 · Installation

Laying methods Sensor leads, panel internal wiring, audio cables, low-level signal — Miniature

Connectors Crimp ferrules / micro-connectors — Small gauge

Shield termination Ground at one or both ends — Per system

Bend radius ≥ 6 × OD ≈ 36 mm — Very flexible
09 · Packing

Standard supply length 100 m / coil m Miniature

Reel / packing type Coil, wrapped — Plastic bag

Surface marking RVVP, 2×0.75, 300/500V, GB/T 9330 — Continuous printing

Approx. cable weight ≈ 65 kg/km 2-core miniature shielded
10 · Applications

Typical use Sensor signal, audio interconnection, data lines, alarm circuits, micro-control — Low-power signal

Max system voltage 500 V 300/500 V

Application level Signal / low-power — Miniature


Cable Test Parameters


Test Parameters — RVVP 2×0.75 mm² Miniature Shielded Control Cable
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance GB/T 3956, 20 °C ≤ 24.5 Ω/km (flexible Cu 0.75) Routine
2 Voltage test (AC) 2.0 kV AC, 5 min No breakdown Routine
3 Insulation resistance 500 V DC ≥ 20 MΩ·km Routine
4 Insulation thickness Micrometer ≥ 0.6 mm Routine
5 Shield coverage Visual / microscopic ≥ 80% braid coverage Routine
6 Shield continuity Per GB/T 9330 Shield electrically continuous Routine
7 Heating test 70 °C conductor, 2 h No damage Type
8 Flexibility / bending test 6× OD, repeated cycles No damage Type
9 Flame retardancy IEC 60332-1 Self-extinguishing Type
10 Dimensional check Caliper OD ≈ 6.0 mm Routine
11 Mutual capacitance Per GB/T 9330 ≤ 200 pF/m Type
12 Printing legibility Visual Marking readable Routine


Cable Cross Section Structure


RVVP 2x0.75mm² Shielded Signal Cable Braided Copper Low Noise Communication Wire 300/500V


RVVP 2×0.75 mm² — Cross-Section Construction Diagram (Schematic)
Miniature shielded: 2×thin flexible Cu → PVC insulation → copper braid shield → PVC sheath · 300/500 V · ≈ 6.0 mm
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductors (×2) Fine-stranded annealed Cu, Class 5, 2×0.75 mm² — ≈ 1.1 each R ≤ 24.5 Ω/km
2 PVC insulation Polyvinyl chloride, per core ≈ 0.6 ≈ 2.3 each 300/500 V rated
3 Copper braid shield Tinned copper wire braid, ≥ 80% coverage ≈ 0.4 ≈ 5.0 EMI/RFI protection
4 PVC outer sheath PVC, dark/black ≈ 1.0 ≈ 6.0 Outer protection
Key Dimensions & Properties (expanded)
Finished cable diameter ≈ 6.0 mm Overall

Approx. cable mass ≈ 65 kg/km Miniature

Nominal voltage rating 300/500 V Signal / control

Max conductor temp. 70 °C PVC rated

Short-circuit temp. 160 °C Max 5 s

Min bending radius (fixed) ≥ 6 × OD ≈ 36 mm Very flexible

DC resistance @ 20 °C ≤ 24.5 Ω/km Flexible Cu 0.75

Test voltage (AC) 2.0 kV / 5 min — Routine

Nominal current (ampacity) ≈ 7 A Low-power signal

Shield coverage ≥ 80 % Copper braid

Shield resistance ≤ 20 Ω/km Braid

Number of cores 2 — Signal pair

Standard GB/T 9330 / IEC 60227 — Control cable

Application Low-level signal / sensor — Miniature

Schematic — not to exact scale. Finished OD ≈ 6.0 mm and weight ≈ 65 kg/km from cross-referenced industry samples. RVVP 2×0.75 is a miniature shielded flexible control cable for low-level signal transmission. Values marked (est.) require confirmation against the factory test certificate.


Construction Description


Construction Description — RVVP 2×0.75 mm² miniature shielded control cable
Layer-by-layer miniature shielded control cable: 2×thin flexible Cu / PVC insulation / copper braid shield / PVC sheath · 300/500 V · 70 °C · ≈ 6.0 mm
1. Product Identity & Ratings
RVVP 2×0.75 is a miniature shielded flexible PVC control cable rated 300/500 V, 70 °C continuous. Built per GB/T 9330 / IEC 60227. Two 0.75 mm² very fine-stranded copper conductors enclosed in a copper wire braid shield (≥ 80% coverage) and PVC outer sheath. Designed for low-level signal circuits. Finished OD ≈ 6.0 mm, mass ≈ 65 kg/km, 100 m coils.
2. Two Very Fine Flexible Copper Conductors
Two 0.75 mm² very fine-stranded annealed copper conductors (Class 5, ~24×0.20 mm). DC resistance ≤ 24.5 Ω/km at 20 °C. The extremely fine stranding gives excellent flexibility for tight routing in sensor leads and panel wiring.
3. Copper Braid Shield
Tinned copper wire braid woven over the insulated cores with ≥ 80% coverage. The shield blocks EMI/RFI from nearby power cables and equipment — critical for microvolt-level sensor signals that are easily corrupted by noise.
4. PVC Outer Sheath
PVC outer sheath ≈ 1.0 mm thick, dark/black. Provides mechanical protection and environmental resistance. The miniature flexible sheath bends easily for tight spaces and small connectors.
5. Site Handling & Operational Notes
• Bend radius 6×OD (≈ 36 mm).  • Use micro-connectors and crimp ferrules.  • Ground shield at one or both ends.  • At 65 kg/km, very light.  • Indoor use.  • Low-power signal only (≈ 7 A max).


8. Standards & Conformity. GB/T 9330 (plastic insulated control cables); IEC 60227 (international); GB/T 3956 (Class 5 flexible conductors). Rated 300/500 V.


9. Packaging, Storage & Logistics. 100 m per coil, plastic wrapped. Continuous marking: RVVP, 2×0.75, 300/500V, GB/T 9330. Store dry, indoor.


RVVP 2x0.75mm² Shielded Signal Cable Braided Copper Low Noise Communication Wire 300/500V


10. Procurement Specification. State "RVVP 2×0.75" + length. Specify shield coverage requirement (≥ 80%). Confirm against factory test certificate.


11. Cable Industry FAQ.

  • Q1: What is the difference between RVVP 2×0.75 and RVVP 2×2.5? The 0.75 mm² version is half the cross-section, 25% thinner (6.0 vs 8.0 mm), half the weight (65 vs 130 kg/km), and one-third the ampacity (7 vs 16 A). It is for low-level signals; the 2.5 mm² version is for control circuits carrying more current.
  • Q2: Why use 0.75 mm² instead of 2.5 mm²? When the signal current is tiny (sensor outputs, microphone-level audio), 0.75 mm² is sufficient and much lighter, more flexible, and easier to route in tight spaces. The higher resistance (24.5 vs 7.41 Ω/km) is irrelevant for microamp-level signals.
  • Q3: What signals can it carry? Low-level sensor signals (4–20 mA loops, thermocouple mV signals), audio interconnection, low-speed data lines, alarm contacts. It is not for power circuits.
  • Q4: Can I use RVVP 2×0.75 for 4–20 mA sensors? Yes — 4–20 mA loop currents are well within its capability, and the shield protects the analog signal from industrial noise.
  • Q5: Is the shield the same as RVVP 2×2.5? Yes — copper wire braid ≥ 80% coverage. The shield diameter is smaller (5.0 vs 7.0 mm) because it wraps smaller cores.
  • Q6: What connectors are used? Micro-connectors, small D-sub, or crimp ferrules. The 1.1 mm conductor diameter requires smaller ferrules than the 2.0 mm conductors in RVVP 2×2.5.
  • Q7: What is the bending radius? 6×OD ≈ 36 mm — even more flexible than the 48 mm of the 2×2.5 version.
  • Q8: Can it be used outdoors? No — PVC sheath is not UV-resistant. For outdoor use, use outdoor-rated cable.
  • Q9: How long can the cable run be? For 4–20 mA loops, typically up to a few hundred meters depending on loop impedance. For high-frequency signals, keep runs short to avoid capacitance effects.
  • Q10: What if I need to carry more current? Step up to RVVP 2×2.5 (16 A) or larger. The 0.75 mm² conductor cannot safely carry more than ~7 A.
  • Q11: How is this different from unshielded RVV? RVV has no shield — use it when there is no nearby noise source. RVVP 2×0.75 adds the copper braid shield for environments with VFDs, motors, or power cables nearby.