RVVP 2x2.5mm² Braided Shielded Flexible Control Cable EMI Noise Protection 300/500V Copper

RVVP 2x2.5mm² Braided Shielded Flexible Control Cable EMI Noise Protection 300/500V Copper

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
RVVP 2x2.5mm²

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
100000 meters per month

Product Summary

RVVP 2x2.5mm² Braided Shielded Flexible Control Cable EMI Noise Protection 300/500V Copper Cable Designation & Meaning Code Meaning R Flexible conductor (Class 5 fine-stranded) V PVC insulation V PVC sheath P Copper wire shield (braid or braid+aluminium foil) 2×2.5 mm² Two cores, each 2.5 mm² copper ...

Product Details

Conductor (×2):
Copper, Class 5 Fine-stranded Flexible, Nominal 35×∅0.30 Mm (2.5 Mm² Per Core), Conductor Ø ≈ 2.2–2.6 Mm
Insulation (per core):
PVC (polyvinyl Chloride)​ Compound, Nominal Thickness 0.8 Mm, Colour: Red​ (signal/power +) And Black​ (signal/power −) Or As Specified
Lay-up:
Two Cores Twisted Together With PVC Filler To Form Round Core Bundle
Shield:
Copper Wire Braid, Coverage 85%–90% (typical), Or Copper Braid + Aluminium Polyester Tape (optional)
Outer sheath:
PVC (polyvinyl Chloride)​ Compound, Nominal Thickness 1.2 Mm (typical), Colour: Grey​ Or Black​ (round Profile)
Conductor nominal area:
2.5 Mm² (Cu)
Number of cores:
2
Conductor material:
Copper (Cu)
Conductor class:
Class 5 Fine-stranded Flexible
Conductor construction:
35×∅0.30 Mm (typical)
Conductor diameter (approx.):
2.2–2.6 Mm
Insulation thickness (per core):
0.8 Mm
Shield coverage:
80%
Outer sheath thickness:
1.2 Mm
Overall cable diameter:
9.5 – 12.0 Mm
Design outer diameter:
≈ 10.5 Mm
Approx. weight:
0.14 – 0.18 Kg/m (140–180 Kg/km)
Design weight:
≈ 160 Kg/km
Cable shape:
Round

Product Description

RVVP 2x2.5mm² Braided Shielded Flexible Control Cable EMI Noise Protection 300/500V Copper

Cable Designation & Meaning

Code

Meaning

R

Flexible conductor (Class 5 fine-stranded)

V

PVC insulation

V

PVC sheath

P

Copper wire shield (braid or braid+aluminium foil)

2×2.5 mm²

Two cores, each 2.5 mm² copper


Construction: Two fine-stranded flexible copper conductors, each PVC insulated, laid up with fillers to form a round core assembly, wrapped with copper braid shield (typically 85%–90% coverage), and extruded with a common round PVC outer sheath.

Applicable Standards

  • JB/T 8734.5-2016 — Rated voltages up to and including 450/750 V PVC insulated cables and cords for fixed wiring and flexible applications — Part 5: Shielded flexible cables
  • GB/T 5023.5-2008 / IEC 60227-5 — Polyvinyl chloride insulated cables — Flexible cables (cords)
  • GB/T 3956 / IEC 60228 — Conductors (Class 5 flexible copper)
  • GB/T 2951 / IEC 60811 — Insulating and sheathing materials — Common test methods
  • GB/T 18380 / IEC 60332-1 — Flame retardant (single cable, passes)
  • GB/T 5441 — Communication cable test methods (shielding effectiveness reference)

RVVP 2x2.5mm² Braided Shielded Flexible Control Cable EMI Noise Protection 300/500V Copper


RVVP 2×2.5 mm² — Shielded Flexible PVC Control Cable — Specification & Engineering Data

1. Overview & Ratings. RVVP 2×2.5 is a shielded flexible PVC control cable rated 300/500 V, 70 °C continuous. Built per GB/T 9330 / IEC 60227. Two 2.5 mm² fine-stranded copper conductors enclosed in a copper wire braid shield (≥ 80% coverage) and PVC outer sheath. Designed for signal and measurement circuits in interference-prone environments. Finished OD ≈ 8.0 mm, ≈ 130 kg/km, 100 m coils.


2. Construction Stack (Conductor → Outer).

Layer Build Wall Diameter
Conductors (×2) Fine-stranded annealed Cu, Class 5, 2×2.5 mm² — ≈ 2.0 mm each
PVC insulation Polyvinyl chloride, per core ≈ 0.7 mm ≈ 3.4 mm each
Copper braid shield Tinned copper wire braid, ≥ 80% coverage ≈ 0.5 mm ≈ 7.0 mm
PVC outer sheath PVC, dark/black ≈ 1.2 mm ≈ 8.0 mm (finished)


3. Electrical Characteristics. DC resistance ≤ 7.41 Ω/km at 20 °C (flexible Cu 2.5 mm²); test voltage 2.0 kV AC / 5 min; insulation resistance ≥ 20 MΩ·km. Shield resistance ≤ 20 Ω/km. Nominal ampacity ≈ 16 A (control circuit). Mutual capacitance ≤ 200 pF/m.

Insulation & Sheath Data

Property

Value

Insulation material

PVC (polyvinyl chloride), Type TI1/TI2

Outer sheath material

PVC (polyvinyl chloride), Type TM1/TM2

Long-term service temp.

70 °C (continuous, both insulation & sheath)

Short-circuit temp. (≤5 s)

160 °C (Cu conductor limit for PVC)

Emergency overload temp.

105 °C (short term)

Test voltage AC (5 min)

2.0 kV (routine test, 300/500 V class)

Dielectric strength

≥ 15 kV/mm (room temp.)

Shielding effectiveness

≥ 60 dB at 30 MHz – 100 MHz (typical copper braid)

Transfer impedance

≤ 100 mΩ/m at 10 MHz (typical)

Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

300 / 500 V

JB/T 8734.5 / GB/T 5023.5

Max. system voltage

500 V AC

—

Test voltage AC (5 min)

2.0 kV

Routine test (core-to-core, core-to-shield)

DC resistance @20 °C

≤ 7.98 Ω/km

GB/T 3956 Class 5 Cu max, 2.5 mm²

AC resistance @70 °C (est.)

≈ 10.1 Ω/km

per core

Current rating in air (30 °C)

18 A​

2-core, open air, reference value

Current rating in tray (30 °C)

16 A​

bundled with other cables

Current rating in conduit (30 °C)

15 A​

enclosed

Short-circuit current (1 s, Cu, 160 °C)

≈ 0.28 kA (280 A)

2.5 mm² Cu

Capacitance (core-to-core, approx.)

≈ 120 pF/m

PVC insulation

Capacitance (core-to-shield, approx.)

≈ 180 pF/m

collective shield

Inductive reactance (approx.)

≈ 0.08 Ω/km

at 50 Hz

Frequency

50/60 Hz AC (signal up to ~10 MHz)

—

Reference values: 2×2.5 mm² at 15–18 A, single-phase 230 V → max load ≈ 3.5–4.1 kW. Signal applications typically carry mA to ~1 A levels.


4. Thermal & Mechanical. 70 °C continuous; 160 °C short-circuit (≤ 5 s); ambient −15~+70 °C. Bend ≥ 6 × OD ≈ 48 mm. Copper braid shield blocks EMI/RFI from nearby power cables and equipment.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

70 °C (continuous)

Max. short-circuit temp. (≤5 s)

160 °C (Cu conductor, PVC limit)

Emergency overload temp.

105 °C (not recommended for continuous)

Min. installation ambient temp.

0 °C (PVC); below 0 °C pre-heating required

Service ambient range

−15 °C to +70 °C (PVC insulation & sheath)

Flexing temp. range

+5 °C to +70 °C (recommended for repeated bending)

Fire survival

Standard (flame retardant single cable)

Fire Performance (RVVP — Standard)

Property

Value / Requirement

Flame retardant

IEC 60332-1 (single cable, passes)

Halogen content

Contains halogen (PVC insulation & sheath)

Smoke density

Standard (non-low-smoke)

Corrosivity

Corrosive (PVC)

Fire survival (circuit integrity)

Not applicable (standard version)

EMI shielding

Yes​ (copper braid, 85%–90% coverage)

RVVP 2x2.5mm² Braided Shielded Flexible Control Cable EMI Noise Protection 300/500V Copper

Shielding Performance

Parameter

Value

Note

Shield type

Copper wire braid (bare or tinned)

—

Coverage

85%–90% (typical)

>90% available on request

Optional

Copper braid + aluminium polyester tape (dual shield)

for high EMI environments

Drain wire

Not required (braid is continuous)

—

Shielding effectiveness

≥ 60 dB @ 30–100 MHz

typical braid

Transfer impedance

≤ 100 mΩ/m @ 10 MHz

—

Application

EMI/RFI protection for signal and control circuits

—


RVVP 2x2.5mm² Braided Shielded Flexible Control Cable EMI Noise Protection 300/500V Copper


5. Installation Practice & Handling. Use shielded connectors. Ground shield at one end (low-frequency signals) or both ends (high-frequency). Do not run shielded and unshielded cables in the same tray. At 130 kg/km, very light. Indoor use only.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 6 × OD → ≈ 63 mm at Ø10.5 mm

flexible conductor, shielded

Max. pulling tension

200 N

fine-stranded Cu (handle gently)

Direct burial

Not recommended​ (no mechanical protection; use conduit)

—

Surface mounting

Good (round profile, cable ties or clips)

—

Conduit ID

≥ 16 mm

—

Fixing

cable ties, clamps, trunking

—

Impact resistance

Low (PVC sheath only)

protect with conduit in exposed areas

Water resistance

Moisture-resistant (PVC)

not waterproof

UV resistance

Poor (PVC degrades in sunlight)

indoor use only

Flex life

High​ (Class 5 fine-stranded, designed for occasional flexing)

—

Termination note

Strip sheath, fold braid back over outer sheath, use heat-shrink or copper strap for shield termination; ferrules recommended for fine-stranded conductors

shield must be grounded at one end (or both, depending on application)


6. Typical Service Applications. Instrument signal transmission, sensor wiring, PLC control circuits, audio interconnection, data acquisition, alarm systems — anywhere low-level signals must be protected from electromagnetic interference.


RVVP 2x2.5mm² Braided Shielded Flexible Control Cable EMI Noise Protection 300/500V Copper


7. Testing & QA Regime. Routine: conductor DC resistance, 2.0 kV AC withstand, insulation resistance, shield coverage check, dimensional check. Type: heating test, bending test, flame retardancy, mutual capacitance measurement.


Cable Parameters


RVVP 2×2.5 mm² — Shielded Flexible PVC Control Cable — Full Parameter Sheet 
Shielded control cable · 2× flexible Cu / PVC insulation / copper braid shield / PVC sheath · 300/500 V · 70 °C · ≈ 8.0 mm · EMI protection
Section Parameter Value Unit Remarks / Standard
01 · Identification

Cable type RVVP — shielded flexible PVC control cable — Shielded control

Rated voltage (U0/U) 300/500 V Signal / control

Number of cores 2 × 2.5 — 2-core

Conductor material Annealed copper, fine-stranded — Class 5 flexible

Insulation material PVC (polyvinyl chloride) — Per core

Shield type Copper wire braid (P) — ≥ 80% coverage

Sheath material PVC (outer, dark) — Flexible

Standard GB/T 9330 / IEC 60227 — Control cable

Application Signal transmission, instrumentation, interference-prone areas — Control / measurement
02 · Conductor (Flexible Cu)

Conductor type Fine-stranded annealed copper — Class 5 flexible

Conductor area 2 × 2.5 mm² 2-core

Stranding construction ≈ 50 × 0.20 mm (approx.) — Very flexible

DC resistance @ 20 °C ≤ 7.41 Ω/km Cu 2.5 mm² flexible

Conductor weight per km ≈ 48 kg/km 2×2.5 Cu

Conductor diameter ≈ 2.0 mm Flexible stranded
03 · Insulation & Shield

Insulation type PVC (per core) — General-purpose

Insulation thickness ≈ 0.7 mm 300/500 V

Insulated core OD ≈ 3.4 mm Per core

Shield type Copper wire braid — P = shield

Shield coverage ≥ 80 % EMI protection

Shield diameter ≈ 7.0 mm Over cores
04 · Sheath

Sheath type PVC outer sheath — Flexible

Sheath thickness ≈ 1.2 mm Control cable

Finished outer diameter ≈ 8.0 mm Overall

Sheath color Dark / black — Standard
05 · Electrical

Rated voltage (U0/U) 300/500 V Signal / control

Max voltage 500 V Phase-to-phase

DC resistance @ 20 °C ≤ 7.41 Ω/km Flexible Cu 2.5

Test voltage (AC) 2.0 kV / 5 min — Routine

Insulation resistance ≥ 20 MΩ·km PVC

Nominal current (ampacity) ≈ 16 A Control circuit

Shield resistance ≤ 20 Ω/km Braid shield
06 · Thermal

Max conductor temp. 70 °C PVC rated

Short-circuit temp. 160 °C Max 5 s

Ambient range -15 ~ +70 °C Indoor

Laying temperature ≥ -10 °C Flexible
07 · Mechanical & Shield

Min bending radius (fixed) ≥ 6 × OD ≈ 48 mm Shielded

Flexibility Good — Class 5 fine strands

Shield attenuation EMI/RFI protected — Copper braid

Shield grounding One or both ends — Per system design
08 · Installation

Laying methods Instrument panels, equipment interconnection, signal circuits — Control cable

Connectors Crimp lugs / ferrules / D-sub connectors — Shielded

Shield termination Ground shield at one end (low freq) or both ends (high freq) — Per system

Bend radius ≥ 6 × OD ≈ 48 mm — Shielded
09 · Packing

Standard supply length 100 m / coil m Control cable

Reel / packing type Coil, wrapped — Plastic bag

Surface marking RVVP, 2×2.5, 300/500V, GB/T 9330 — Continuous printing

Approx. cable weight ≈ 130 kg/km 2-core shielded
10 · Applications

Typical use Instrument signal, sensor wiring, PLC control, audio interconnection, interference-prone environments — Control / measurement

Max system voltage 500 V 300/500 V

Application level Control / signal — Low voltage


Cable Test Parameters


Test Parameters — RVVP 2×2.5 mm² Shielded Control Cable
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance GB/T 3956, 20 °C ≤ 7.41 Ω/km (flexible Cu 2.5) Routine
2 Voltage test (AC) 2.0 kV AC, 5 min No breakdown Routine
3 Insulation resistance 500 V DC ≥ 20 MΩ·km Routine
4 Insulation thickness Micrometer ≥ 0.7 mm Routine
5 Shield coverage Visual / microscopic ≥ 80% braid coverage Routine
6 Shield continuity Per GB/T 9330 Shield electrically continuous Routine
7 Heating test 70 °C conductor, 2 h No damage Type
8 Flexibility / bending test 6× OD, cycles No damage Type
9 Flame retardancy IEC 60332-1 Self-extinguishing Type
10 Dimensional check Caliper OD ≈ 8.0 mm Routine
11 Mutual capacitance Per GB/T 9330 ≤ 200 pF/m Type
12 Printing legibility Visual Marking readable Routine


Cable Cross Section Structure


RVVP 2x2.5mm² Braided Shielded Flexible Control Cable EMI Noise Protection 300/500V Copper

RVVP 2×2.5 mm² — Cross-Section Construction Diagram (Schematic)
Shielded control cable: flexible Cu conductors → PVC insulation → copper braid shield → PVC sheath · 300/500 V · ≈ 8.0 mm
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductors (×2) Fine-stranded annealed Cu, Class 5, 2×2.5 mm² — ≈ 2.0 each R ≤ 7.41 Ω/km
2 PVC insulation Polyvinyl chloride, per core ≈ 0.7 ≈ 3.4 each 300/500 V rated
3 Copper braid shield Tinned copper wire braid, ≥ 80% coverage ≈ 0.5 ≈ 7.0 EMI/RFI protection
4 PVC outer sheath PVC, dark/black ≈ 1.2 ≈ 8.0 Outer protection
Key Dimensions & Properties (expanded)
Finished cable diameter ≈ 8.0 mm Overall

Approx. cable mass ≈ 130 kg/km 2-core shielded

Nominal voltage rating 300/500 V Signal / control

Max conductor temp. 70 °C PVC rated

Short-circuit temp. 160 °C Max 5 s

Min bending radius (fixed) ≥ 6 × OD ≈ 48 mm Shielded

DC resistance @ 20 °C ≤ 7.41 Ω/km Flexible Cu 2.5

Test voltage (AC) 2.0 kV / 5 min — Routine

Nominal current (ampacity) ≈ 16 A Control circuit

Shield coverage ≥ 80 % Copper braid

Shield resistance ≤ 20 Ω/km Braid

Number of cores 2 — Signal pair

Standard GB/T 9330 / IEC 60227 — Control cable

Application Signal / instrumentation — EMI-protected

Schematic — not to exact scale. Finished OD ≈ 8.0 mm and weight ≈ 130 kg/km from cross-referenced industry samples. RVVP 2×2.5 is a shielded flexible control cable for signal transmission in interference-prone environments. Values marked (est.) require confirmation against the factory test certificate.


Construction Description


Construction Description — RVVP 2×2.5 mm² shielded control cable
Layer-by-layer shielded control cable: 2×flexible Cu / PVC insulation / copper braid shield / PVC sheath · 300/500 V · 70 °C · ≈ 8.0 mm
1. Product Identity & Ratings
RVVP 2×2.5 is a shielded flexible PVC control cable rated 300/500 V, 70 °C continuous. Built per GB/T 9330 / IEC 60227. The copper wire braid shield provides EMI/RFI protection for signal and measurement circuits. Finished OD ≈ 8.0 mm, mass ≈ 130 kg/km, 100 m coils.
2. Two Flexible Copper Conductors
Two 2.5 mm² fine-stranded annealed copper conductors (Class 5, ~50×0.20 mm). DC resistance ≤ 7.41 Ω/km at 20 °C. The flexible construction allows routing around equipment and panels.
3. Copper Braid Shield
Tinned copper wire braid woven over the insulated cores with ≥ 80% coverage. The shield blocks electromagnetic interference (EMI) and radio-frequency interference (RFI) from nearby power cables and equipment — critical for low-level signal circuits.
4. PVC Outer Sheath
PVC outer sheath ≈ 1.2 mm thick, dark/black. Provides mechanical protection and environmental resistance. The flexible sheath bends easily for panel wiring and equipment interconnection.
5. Site Handling & Operational Notes
• Bend radius 6×OD (≈ 48 mm).  • Ground shield at one end (low-frequency) or both ends (high-frequency).  • Use shielded connectors.  • At 130 kg/km, very light.  • Indoor use.  • Do not mix shielded and unshielded in same tray.


8. Standards & Conformity. GB/T 9330 (plastic insulated control cables); IEC 60227 (international); GB/T 3956 (Class 5 flexible conductors). Rated 300/500 V.


9. Packaging, Storage & Logistics. 100 m per coil, plastic wrapped. Continuous marking: RVVP, 2×2.5, 300/500V, GB/T 9330. Store dry, indoor.


RVVP 2x2.5mm² Braided Shielded Flexible Control Cable EMI Noise Protection 300/500V Copper


10. Procurement Specification. State "RVVP 2×2.5" + length. Specify shield coverage requirement (≥ 80%). Confirm against factory test certificate.


11. Cable Industry FAQ.

  • Q1: What does "RVVP" mean? R = flexible (soft); V = PVC insulation; V = PVC sheath; P = shielded (copper braid). It is a shielded flexible control cable.
  • Q2: What is the difference between RVVP and RVV? RVV is unshielded. RVVP adds a copper wire braid shield over the insulated cores. Use RVVP when nearby power cables or motors could induce noise into signal circuits.
  • Q3: Why use a shielded cable? In industrial environments, power cables, VFDs, and motors radiate electromagnetic noise. The copper braid shield absorbs this noise and prevents it from corrupting low-level sensor or control signals.
  • Q4: Should the shield be grounded at one end or both ends? For low-frequency signals (< 1 MHz), ground at one end only to avoid ground loops. For high-frequency signals (> 1 MHz), ground at both ends for better high-frequency shielding.
  • Q5: What is the difference between this and YJV22 power cable? YJV22 is a large armored power cable (62 mm, 8200 kg/km, 370 A) for high-power distribution. RVVP is a small shielded control cable (8 mm, 130 kg/km, 16 A) for low-level signal circuits. They serve completely different purposes.
  • Q6: Can RVVP carry power? It can carry limited power (≈ 16 A), but that is not its purpose. Use RVVP for signal and control. For power, use RVV or YJV.
  • Q7: What is the shield coverage? ≥ 80% copper braid coverage. Higher coverage provides better shielding but reduces flexibility.
  • Q8: Can I use RVVP outdoors? No — PVC sheath is not UV-resistant. For outdoor use, use outdoor-rated cable.
  • Q9: What connectors should I use? Use shielded connectors (D-sub, M12, etc.) that maintain the shield continuity through the connector. Do not break the shield at the connector.
  • Q10: Can I run RVVP parallel to power cables? Avoid it if possible. If unavoidable, maintain at least 200 mm separation and cross at 90°. The shield helps but does not eliminate all interference.
  • Q11: What is the bending radius? 6×OD ≈ 48 mm — flexible enough for panel wiring and equipment interconnection.