Tinned Copper Photovoltaic Solar Cable Solar Panel UV Resistant PV Wire

Tinned Copper Photovoltaic Solar Cable Solar Panel UV Resistant PV Wire

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC/TUV/UV
product model
H1Z2Z2-K 4.0 mm²

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
100000 meters per month

Product Summary

Solar Panel Cable H1Z2Z2-K 4.0mm² TUV 1500V DC UV Resistant PV Wire Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) Z Halogen...

Product Details

Highlight:

tinned copper photovoltaic solar cable

,

photovoltaic solar cable solar panel

,

uv resistant pv wire

Conductor:
Tinned Copper, Class 5 Fine-stranded Flexible, Nominal 56×∅0.30 Mm (4.0 Mm²), Conductor Ø ≈ 3.0 Mm
Insulation:
Halogen-free Cross-linked Polyolefin (XLPO), Nominal Thickness 0.8 Mm (typical), Colour: Black
Outer sheath:
Halogen-free Cross-linked Polyolefin (XLPO), Nominal Thickness 0.8 Mm (typical), Colour: Black​ (red Available For Polarity Identification)
Conductor nominal area:
4.0 Mm² (Cu, Tinned)
Number of cores:
1
Conductor material:
Tinned Copper (Cu)
Conductor class:
Class 5 Flexible
Conductor construction:
56×∅0.30 Mm (typical)
Conductor diameter (approx.):
3.0 Mm
Insulation thickness:
0.8 Mm
Outer sheath thickness:
0.8 Mm
Overall cable diameter:
5.2 – 6.0 Mm
Design outer diameter:
≈ 5.6 Mm
Approx. weight:
0.055 – 0.070 Kg/m (55–70 Kg/km)
0.055 – 0.070 kg/m (55–70 kg/km):
≈ 62 Kg/km
Cable shape:
Round

Product Description

Solar Panel Cable H1Z2Z2-K 4.0mm² TUV 1500V DC UV Resistant PV Wire

Cable Designation & Meaning

 

Code

Meaning

H

Harmonized cable (H)

1

Rated voltage 1 kV AC (U₀/U = 1/1 kV reference)

Z

Halogen-free compound (Z = halogen-free)

2

Insulation layer — cross-linked halogen-free compound (XLPO)

Z

Halogen-free compound (Z = halogen-free)

2

Sheath layer — cross-linked halogen-free compound (XLPO)

2

Sheath layer — cross-linked halogen-free compound (XLPO)

K

Flexible conductor (Class 5 fine-stranded)

4.0 mm²

Nominal cross-sectional area of conductor

 

Construction: Tinned copper conductor, halogen-free cross-linked polyolefin (XLPO) insulation and sheath, single-core flexible photovoltaic DC cable.

 

Note on designation: H1Z2Z2-K is the EN 50618 / TÜV 2 PfG 1169/08.2007 designation. It is functionally equivalent to PV1-F 4.0 mm² but uses the harmonized cable coding system.

Applicable Standards

  • EN 50618:2014 — Electric cables for photovoltaic systems (DC rated voltage 1.8 kV)
  • IEC 62930 — Photovoltaic system cables (single-core, XLPO insulated, rated up to 1.5 kV DC)
  • TÜV 2 PfG 1169/08.2007 — TÜV specification for PV cables
  • IEC 60228 / GB/T 3956 — Conductors (Class 5 flexible, tinned copper)
  • IEC 60332-1 — Flame retardant (single cable)
  • IEC 61034 — Smoke density (low smoke)
  • IEC 60754 — Halogen content (halogen-free)
  • IEC 60811 — Insulating and sheathing materials — Common test methods

Tinned Copper Photovoltaic Solar Cable Solar Panel  UV Resistant PV Wire

Tinned Copper Photovoltaic Solar Cable Solar Panel  UV Resistant PV Wire

H1Z2Z2-K 1×4.0 mm² (v2, thin-wall compact) — Harmonised Photovoltaic DC Cable Specification & Engineering Data

1. Product Overview & Rating Summary. H1Z2Z2-K 1×4.0 v2 is the thin-wall compact build of the harmonised European photovoltaic DC cable rated 0.6/1.0 kV DC (max system voltage 1.8 kV), built and certified to EN 50618 / HD 6036 with the HAR certification mark. This v2 uses reduced wall thickness — 0.7 mm inner halogen-free XLPE insulation plus 0.7 mm outer halogen-free cross-linked polyolefin sheath (vs v1's 0.8+0.8 mm) — giving a smaller finished diameter of about 4.9 mm, lighter mass of about 42 kg/km, and slightly higher ampacity of about 46 A. It is the choice for space-constrained European rooftop PV installations where the cable must pull through thin conduit or narrow trunking. Supplied in 50 m small coils for DIY retail.

 

2. Layer-by-Layer Construction (Conductor to Outer).

Layer Construction Wall Diameter
Conductor Flexible stranded tinned Cu, Class 5 — 56 × 0.30 mm — ≈ 2.5 mm
Inner insulation Halogen-free cross-linked polyethylene (XLPE), Z2, thin-wall 0.7 mm ≈ 3.9 mm
Outer sheath Halogen-free cross-linked polyolefin, Z2, black, thin-wall 0.7 mm ≈ 4.9 mm (finished)
Armour None — unarmoured flexible cable — —

 

3. Electrical Characteristics. The 4.0 mm² tinned-copper Class 5 conductor uses 56 × 0.30 mm tinned wires, giving a maximum DC resistance of 4.49 Ω/km at 20 °C. Routine proof is 3.5 kV AC / 5 minutes (or 6.5 kV DC / 15 minutes). Insulation resistance ≥ 200 MΩ·km. With the single core in free air at 30 °C, reference loading is about 46 A; at 60 °C ambient the rating derates to about 36 A. The voltage drop on a 100 m two-pole run at 46 A is about 4.1 V loop. Conductor loss at 46 A is about 3.0 W per metre at 90 °C.

Insulation & Sheath Data

Property

Value

Material

XLPO (cross-linked polyolefin), halogen-free

Insulation nominal thickness

0.8 mm

Sheath nominal thickness

0.8 mm

Long-term service temp.

−40 °C to +120 °C​ (continuous)

Short-circuit temp. (≤5 s)

280 °C​ (Cu conductor limit)

Emergency overload temp.

150 °C (short term)

Weather resistance

Excellent — UV resistant, ozone resistant, hydrolysis resistant

Flame retardant

IEC 60332-1 (single cable)

Smoke density

IEC 61034 (low smoke)

Halogen content

IEC 60754 (halogen-free, non-corrosive)

Oil resistance

EN 50618 Annex B (optional)

Acid & alkali resistance

Good

Electrical Parameters

 

Parameter

Value

Note

Rated voltage AC (U₀/U)

1.0 / 1.0 kV

EN 50618 reference (AC rating)

Rated voltage DC

1.5 kV​

EN 50618 / IEC 62930 primary rating

Test voltage AC (50 Hz, 5 min)

6.5 kV

Routine test

DC test voltage

15 kV DC (for type test)

—

DC resistance @20 °C

≤ 5.09 Ω/km

IEC 60228 Class 5 max, 4.0 mm²

AC resistance @90 °C (est.)

≈ 6.48 Ω/km

—

AC resistance @120 °C (est.)

≈ 7.30 Ω/km

max service temp

Capacitance (approx.)

≈ 0.18 µF/km

conductor to sheath

Inductive reactance (approx.)

negligible

single-core DC application

Current rating in free air (60 °C ambient)

55 A​

single cable, DC

Current rating in free air (ambient corrected)

≈ 44 A​ at 70 °C ambient

typical rooftop condition

Current rating in conduit (air)

≈ 41 A​

bundled cables

Short-circuit current (1 s, Cu, 280 °C)

≈ 0.44 kA (440 A)

4.0 mm² Cu

Frequency

DC (primary) / 50–60 Hz AC (secondary)

—

Reference values: 4.0 mm² Cu at 44 A, DC 1000 V → max DC power ≈ 44 kW per string (2 strings in parallel = 88 kW). Voltage drop at 44 A ≈ 22.4 mV/A·m (≈2.24% per 10 m at 44 A, 1000 V).

Temperature Characteristics

Property

Value

Max. conductor operating temp. (continuous)

120 °C

Max. short-circuit temp. (≤5 s)

280 °C (Cu conductor)

Emergency overload temp.

150 °C (short term)

Min. installation ambient temp.

−40 °C​ (cold-flexible, no pre-heating required)

Service ambient range

−40 °C to +120 °C​ (with XLPO)

Fire survival

Standard (flame retardant single cable); optional fire-rated version available

 

 

4. Thermal Response & Flame Behaviour. Halogen-free cross-linked XLPE sustains a 90 °C continuous conductor temperature, with short-circuit capability up to 250 °C for ≤ 5 s. The cable is rated for service ambients between −40 °C and +90 °C and is cold-bend tested at −40 °C. The black carbon-loaded outer sheath is UV-resistant (1000 h UV preconditioning), ozone-resistant, and flame-retardant to IEC 60332-1 (single-cable vertical flame, self-extinguishing). The Z2 designation means the cable releases no halogen acid gas (IEC 60754, ≤ 0.5% HCl equivalent) and low smoke (IEC 61034, light transmittance ≥ 60%) when burned.

Fire Performance (H1Z2Z2-K — Standard)

Property

Value / Requirement

Flame retardant

IEC 60332-1 (single cable, passes)

Halogen content

Halogen-free​ (IEC 60754)

Smoke density

Low smoke​ (IEC 61034)

Corrosivity

Non-corrosive​ (IEC 60754)

Toxicity

Low (halogen-free materials)

Fire survival (circuit integrity)

Not applicable (standard PV cable); use fire-rated DC cable if required

 

5. Installation Practice & Handling. Minimum bend radius is 4 × OD (≈ 20 mm) for fixed installation, 6 × OD (≈ 29 mm) if repeatedly flexed. The reduced outer diameter (≈ 4.9 mm vs v1's ≈ 5.1 mm) makes this v2 easier to pull through thin conduit and narrow trunking in space-constrained European rooftop installations. Use PV4 / MC4-type connectors crimped with the dedicated PV crimping tool. Polarity (+ / −) and the HAR mark are printed along the black sheath. Laying temperature must not fall below −40 °C. At about 4.2 kg per 100 m, the cable is light and supplied in 50 m small coils — ideal for DIY residential PV.

 

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 4 × OD → ≈ 22.4 mm at Ø5.6 mm

static installation

Min. bending radius (installed)

≥ 2 × OD → ≈ 11.2 mm

dynamic (flexing)

Max. pulling tension

160 N

fine-stranded Cu, use proper grips

Direct burial

Suitable​ (UV & moisture resistant)

—

Conduit ID

≥ 1.5 × OD → ≥ 8.4 mm; use 16 mm or 20 mm

—

Fixing

cable ties (UV-resistant), clamps

—

Impact resistance

Moderate

flexible cable, not armoured

Water resistance

Excellent​ (XLPO sheath, IP67 rated connectors)

suitable for outdoor/wet

UV resistance

Excellent​ (EN 50618, 720 h UV test)

outdoor exposed

Ozone resistance

Excellent​ (IEC 60811-403)

—

Termination note

Use MC4 connectors​ (compatible 4.0 mm²) or copper lugs

strip length 10–12 mm

 

Tinned Copper Photovoltaic Solar Cable Solar Panel  UV Resistant PV Wire

 

6. Typical Service Applications. This thin-wall compact build is the default interconnection cable for: European rooftop PV with thin conduit pulls, narrow trunking installations, space-constrained installs, DIY residential PV, balcony PV, and any PV project where conduit fill ratio is tight. The reduced wall thickness (vs v1's 0.8+0.8 mm) is specified when the cable must pass through limited-diameter conduit or crowded trunking without excessive pulling force.

 

Tinned Copper Photovoltaic Solar Cable Solar Panel  UV Resistant PV Wire

 

7. Testing & Quality Assurance Regime. Routine tests on every coil include conductor DC resistance ≤ 4.49 Ω/km at 20 °C, the 3.5 kV AC / 5 min withstand, the 6.5 kV DC / 15 min withstand, insulation resistance ≥ 200 MΩ·km, dimensional check (inner insulation ≥ 0.7 mm; outer sheath ≥ 0.7 mm; OD ≈ 4.9 mm), and visual marking. Type tests include UV preconditioning (1000 h), thermal ageing (135 °C / 168 h), cold bend at −40 °C, heat shock at 150 °C, single-cable flame per IEC 60332-1, halogen acid gas per IEC 60754, smoke density per IEC 61034, ozone resistance, abrasion resistance, and tinned-copper strip check.

 

Cable Parameters

 

H1Z2Z2-K 1×4.0 mm² — Harmonised Photovoltaic DC Cable — Full Parameter Sheet 
Harmonised PV cable · tinned copper flexible conductor (Class 5) / double-layer halogen-free cross-linked insulation + sheath · 0.6/1.0 kV DC · IEC 60332-1 · HAR certified · per EN 50618 / HD 6036 · finished Ø ≈ 5.1 mm
Section Parameter Value Unit Remarks / Standard
01 · Identification
  Cable type H1Z2Z2-K (harmonised PV cable) — Harmonised European PV cable, single core, flexible
  Rated voltage (U0/U) 0.6/1.0 kV DC; for PV array interconnection
  Number of cores 1 × 4.0 — Single core (one + and one − per string)
  Conductor material Tinned annealed copper — Class 5 flexible per EN 60228
  Insulation material Halogen-free cross-linked polyethylene (XLPE) — Z2 = halogen-free, UV/ozone resistant
  Outer sheath material Halogen-free cross-linked polyolefin — Z2 = halogen-free, weather jacket
  Flame retardancy IEC 60332-1 (single-cable vertical flame) — Single-cable self-extinguishing
  Certification HAR (harmonised) — EN 50618 / HD 6036 harmonised standard
02 · Conductor (Tinned Copper)
  Stranding — 4.0 mm² Flexible stranded tinned copper — Class 5 per EN 60228
  Strand count (typical) 56 × 0.30 mm Tinned copper wires
  Conductor diameter ≈ 2.5 mm After stranding (est.)
  DC resistance @ 20 °C ≤ 4.49 Ω/km Maximum per EN 60228 Class 5
  Conductor screen None — LV DC cable
  Conductor weight per km ≈ 42 kg/km Copper density 8.89 g/cm³
03 · Insulation & Sheath (Double-Layer)
  Inner insulation type Halogen-free cross-linked polyethylene (XLPE) — Z2 = halogen-free
  Inner insulation thickness 0.8 mm Nominal
  Outer sheath type Halogen-free cross-linked polyolefin — Z2 = halogen-free weather jacket
  Outer sheath thickness 0.8 mm Nominal
  Finished outer diameter ≈ 5.1 mm 2.5 + 2×0.8 + 2×0.8
  Colour Black (standard) — UV-resistant carbon-black
04 · Electrical
  Rated voltage (DC) 0.6/1.0 kV Max system voltage 1.8 kV DC
  DC resistance @ 20 °C ≤ 4.49 Ω/km 4.0 mm² Cu Class 5
  Insulation resistance ≥ 200 MΩ·km XLPE at 20 °C
  Conductor loss (at 45 A) ≈ 2.9 W/m I²R at 90 °C
  Routine test voltage (AC) 3.5 kV / 5 min — Power-frequency withstand
  Voltage test (DC) 6.5 kV / 15 min — DC withstand test
05 · Thermal & Weather
  Max continuous conductor temp. 90 °C Standard rated
  Short-circuit temp. (≤ 5 s) 250 °C XLPE limit
  Min installation temp. -40 °C Cold-bend test
  Service ambient range -40 to +90 °C European / temperate climates
  UV resistance 1000 h UV preconditioning — Per EN 50618
  Ozone resistance Yes — Tested per EN 50618
  Halogen-free Yes — Z2 = halogen-free (IEC 60754)
  Flame retardancy IEC 60332-1 (single-cable) — Vertical flame, self-extinguishing
06 · Mechanical
  Min bending radius (fixed) ≥ 4 × OD ≈ 20 mm Flexible cable
  Min bending radius (flexing) ≥ 6 × OD ≈ 31 mm If repeatedly moved
  Tensile strength (insulation) ≥ 15.0 MPa After ageing at 135 °C
  Abrasion resistance Yes — Tinned strands resist oxidation
  Oil / fuel resistance Limited — Avoid prolonged contact
07 · Ampacity
  Air ampacity (open, 30 °C) ≈ 45 A Single core, free air
  Air ampacity (open, 60 °C) ≈ 35 A Derating at high ambient
  Voltage drop (per 100 m @ 45 A) ≈ 2.0 V Two-pole loop ≈ 4.0 V
08 · Installation
  Laying methods Rooftop PV, ground-mount, cable tray, conduit — European PV installations
  Connectors PV4 / MC4-type — Crimped with dedicated tool
  Polarity Marked on sheath — + / − printed along length
  Special tools PV crimper, cable cutter, torque wrench — MC4 connectors require dedicated tool
09 · Packing
  Standard supply length 100 m / coil (retail) m European DIY / residential PV
  Reel / packing type Coil (residential) / drum (utility) — Sealed ends against moisture
  Surface marking H1Z2Z2-K, 1×4.0, 0.6/1.0 kV, +/−, HAR, metre marks, year — Continuous printing
  Storage conditions Dry, covered, −20 to +40 °C — Protect from UV during storage
10 · Applications
  Typical use European rooftop PV, residential / commercial PV, utility-scale PV, ground-mount PV, barn / agricultural PV — European / temperate climates
  Max system voltage 1.8 kV DC Open-circuit Voc at lowest temp
  String current rating Up to 45 A Per string fusing

 

Cable Test Parameters

 

Test Parameters — H1Z2Z2-K 1×4.0 mm² (double-layer halogen-free)
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance EN 60228, 20 °C ≤ 4.49 Ω/km (4.0 mm² Cu) Routine
2 Power-frequency withstand 3.5 kV AC, 5 min No breakdown Routine
3 DC withstand test 6.5 kV DC, 15 min No breakdown Routine
4 Insulation resistance At 500 V DC, 20 °C ≥ 200 MΩ·km Routine
5 Dimensional check Micrometer Inner insulation ≥ 0.8 mm; outer sheath ≥ 0.8 mm; OD ≈ 5.1 mm Routine
6 UV preconditioning 1000 h UV exposure No cracking / embrittlement Type
7 Thermal ageing 168 h at 135 °C No cracking after bend test Type
8 Cold bend test −40 °C, mandrel 4×OD No cracks Type
9 Heat shock 15 min at 150 °C No cracking Type
10 Single-cable flame IEC 60332-1 vertical flame Self-extinguishing Type
11 Halogen acid gas IEC 60754-1/-2 ≤ 0.5% HCl equivalent Type
12 Smoke density IEC 61034-2 Light transmittance ≥ 60% Type
13 Ozone resistance Ozone chamber test No cracking Type
14 Abrasion resistance Tape abrasion test Per EN 50618 Type
15 Tinned copper check Strip test on strands Uniform tin coating Routine
16 Marking legibility Visual + rubbing H1Z2Z2-K / 1×4.0 / HAR / metre marks Routine

 

Cable Cross Section Structure

 

Tinned Copper Photovoltaic Solar Cable Solar Panel  UV Resistant PV Wire

 

H1Z2Z2-K 1×4.0 mm² — Cross-Section Construction Diagram (Schematic)
Harmonised PV cable build-up: tinned copper flexible conductor → inner halogen-free XLPE insulation → outer halogen-free cross-linked polyolefin sheath · 0.6/1.0 kV DC · IEC 60332-1 · finished Ø ≈ 5.1 mm
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor Flexible stranded tinned copper, Class 5 — 56 × 0.30 mm — ≈ 2.5 Power conductor; R ≤ 4.49 Ω/km at 20 °C
2 Inner insulation Halogen-free cross-linked polyethylene (XLPE), Z2 0.8 ≈ 4.1 Main electrical insulation; halogen-free
3 Outer sheath Halogen-free cross-linked polyolefin, Z2, black 0.8 ≈ 5.1 (finished) Weather jacket; UV/ozone resistant; halogen-free
4 (No armour) — — — Unarmoured — flexible cable for PV use
Key Dimensions & Properties (expanded)
Finished cable diameter ≈ 5.1 mm 2.5 + 2×0.8 + 2×0.8    
Approx. cable mass ≈ 45 kg/km Cu + XLPE + sheath    
Nominal voltage rating 0.6/1.0 kV DC PV array DC    
Max system voltage 1.8 kV DC Open-circuit Voc    
Max continuous conductor temp. 90 °C Standard rated    
Short-circuit temp. (≤5 s) 250 °C XLPE limit    
Min installation temp. -40 °C Cold-bend tested    
Min bending radius ≥ 4 × OD ≈ 20 mm Fixed installation    
DC resistance @ 20 °C ≤ 4.49 Ω/km 4.0 mm² Cu Class 5    
Insulation resistance ≥ 200 MΩ·km XLPE    
Routine test voltage (AC) 3.5 kV / 5 min — Power-frequency withstand    
Routine test voltage (DC) 6.5 kV / 15 min — DC withstand    
Air ampacity @ 30 °C ≈ 45 A Single core, free air (est.)    
Flame retardancy IEC 60332-1 — Single-cable vertical flame    
Halogen-free Yes (Z2) — IEC 60754 / IEC 61034    
UV resistance 1000 h — Per EN 50618    
Schematic — not to exact scale. Finished Ø ≈ 5.1 mm and weight ≈ 45 kg/km from cross-referenced industry samples; conductor/insulation dimensions per EN 50618 and EN 60228; ampacity 45 A is an engineering estimate for single core in free air. H1Z2Z2-K is the harmonised European equivalent of PV1-F — the key difference is the double-layer construction (inner halogen-free XLPE insulation + outer halogen-free cross-linked polyolefin sheath), both rated Z2 (halogen-free). The HAR certification mark confirms compliance with the harmonised European standard. Always use PV4/MC4-type connectors crimped with the dedicated tool. Values marked (est.) require confirmation against the factory test certificate.

 

Construction Description

 

Construction Description — H1Z2Z2-K 1×4.0 mm² (harmonised double-layer halogen-free)
Layer-by-layer PV build-up · tinned copper flexible / inner halogen-free XLPE insulation + outer halogen-free cross-linked polyolefin sheath · 0.6/1.0 kV DC · IEC 60332-1 · finished Ø ≈ 5.1 mm
1. Product Identity & Ratings
H1Z2Z2-K 1×4.0 is the harmonised European photovoltaic DC cable rated 0.6/1.0 kV DC (max system voltage 1.8 kV), built and certified to EN 50618 / HD 6036 with the HAR (harmonised) certification mark. Unlike PV1-F (which uses a single-layer insulation that doubles as the weather jacket), H1Z2Z2-K uses a double-layer construction: an inner halogen-free XLPE insulation plus an outer halogen-free cross-linked polyolefin sheath, both rated Z2 (halogen-free). This double-layer design provides enhanced mechanical protection and weather resistance. Finished diameter is about 5.1 mm, mass about 45 kg/km, and it is supplied in 100 m coils (residential) or drums (utility).
2. Tinned Copper Flexible Conductor
The 4.0 mm² conductor is Class 5 flexible stranded tinned copper — 56 individual 0.30 mm tinned wires — giving a conductor diameter of about 2.5 mm and a maximum DC resistance of 4.49 Ω/km at 20 °C. The fine-strand construction gives the cable excellent flexibility for routing on rooftop racking, and the tin plating protects the copper strands against oxidation and atmospheric corrosion over decades of outdoor service.
3. Inner Halogen-Free XLPE Insulation
The conductor is fully enclosed in a 0.8 mm layer of halogen-free cross-linked polyethylene (XLPE). This inner layer provides the primary electrical insulation — it is the layer that withstands the 3.5 kV AC routine test. The Z2 designation means the insulation contains no halogen compounds, so when burned it releases no hydrochloric acid gas. The irradiation process cross-links the polymer chains, giving XLPE a 90 °C continuous conductor temperature rating (short-circuit up to 250 °C for ≤ 5 s).
4. Outer Halogen-Free Cross-Linked Sheath
Over the inner insulation is a 0.8 mm layer of halogen-free cross-linked polyolefin — the outer weather jacket. This outer sheath provides mechanical protection against abrasion, UV radiation, ozone, and weathering. It is the layer that faces the outside environment. The black carbon-loaded sheath is UV-resistant (1000 h UV preconditioning). The double-layer design (insulation + sheath) is the key structural difference from PV1-F, which uses a single-layer insulation that doubles as the jacket.
5. Site Handling & Operational Notes
• Use PV4 / MC4-type connectors crimped with the dedicated PV crimping tool — never substitute generic lugs.  • Observe the 4 × OD minimum bend radius (≈ 20 mm); if flexed repeatedly, use 6 × OD.  • Service range −40 to +90 °C; conductor up to 90 °C continuous.  • Routine test 3.5 kV AC / 5 min.  • UV preconditioning: 1000 h UV exposure per EN 50618.  • Halogen-free: IEC 60754 acid gas ≤ 0.5% HCl; IEC 61034 smoke transmittance ≥ 60%.  • At ≈ 4.5 kg per 100 m, the cable is light and supplied in 100 m coils — ideal for residential European rooftop PV.  • The HAR mark confirms harmonised European compliance — required for projects that specify harmonised cables.

 

8. Factory Advantages.

 

Tinned Copper Photovoltaic Solar Cable Solar Panel  UV Resistant PV Wire

 

Tinned Copper Photovoltaic Solar Cable Solar Panel  UV Resistant PV Wire

 

9. Packaging, Storage & Logistics. Standard delivery is 50 m per small coil (DIY retail / residential), also 100 m coils or drums on request. Each coil carries continuous marking: H1Z2Z2-K, 1×4.0, 0.6/1.0 kV, + / −, HAR, thin-wall, supplier identity, production year, and sequential metre marks. Storage should be in dry, covered premises at −20 to +40 °C, shielded from direct sunlight.

 

Tinned Copper Photovoltaic Solar Cable Solar Panel  UV Resistant PV Wire

 

10. Procurement Specification. State "H1Z2Z2-K 1×4.0 mm² 0.6/1.0 kV DC — thin-wall compact build, 50 m small coil" together with the required length. Always order PV4 / MC4-type connectors and the dedicated crimping tool at the same time. Always request the factory test certificate. Specify this v2 thin-wall build for space-constrained / thin conduit installs; for standard racking with ample clearance, the v1 0.8+0.8 mm build provides more mechanical margin.

 

11. Cable Industry FAQ.

  • Q1: What is the difference between this v2 thin-wall build and the v1 standard build? The v2 uses 0.7 mm inner insulation + 0.7 mm outer sheath (total 1.4 mm double-wall), while the v1 uses 0.8+0.8 mm (total 1.6 mm). The v2 has a smaller finished diameter (≈ 4.9 mm vs ≈ 5.1 mm), lighter weight (≈ 42 kg/km vs ≈ 45 kg/km), and slightly higher ampacity (≈ 46 A vs ≈ 45 A) due to better heat dissipation through the thinner wall.
  • Q2: Why use thin-wall cable in rooftop PV? In European rooftop installations, PV cables often must pull through thin conduit already shared with AC wiring, or through narrow trunking in eaves and loft spaces. The 0.2 mm reduction in outer diameter (≈ 4.9 vs ≈ 5.1 mm) can be the difference between a successful pull and a jammed cable in crowded conduit.
  • Q3: Does the reduced wall thickness compromise electrical safety? No — the 0.7 mm inner insulation still withstands the 3.5 kV AC routine test and meets all EN 50618 dimensional requirements. The outer sheath provides weather protection; the inner layer provides electrical insulation.
  • Q4: Why use 50 m small coils? The 50 m coil format is designed for DIY residential PV and balcony PV installations, where the installer typically needs 20–40 m of cable per string. The small coil is easier to handle on a rooftop than a 100 m drum.
  • Q5: Why is it single-core, not two-core? PV strings carry DC at up to 1.8 kV. Running + and − in separate single-core cables keeps the installation modular and avoids loop-current heating in shared conductors.
  • Q6: Why use tinned copper? Tinning protects the copper strands against oxidation and atmospheric corrosion over decades of outdoor service.
  • Q7: Why use MC4 connectors? MC4 (PV4) connectors are weather-sealed, polarised, and rated for 1.5 kV DC. They are crimped with the dedicated tool — hand-twisted terminals are the #1 failure point in PV DC arrays.
  • Q8: When should I choose v1 instead of v2? Choose v1 (0.8+0.8 mm) when the cable runs exposed on racking with risk of abrasion, or when mechanical margin is important. Choose v2 (0.7+0.7 mm) when the cable must pull through thin conduit or narrow trunking where every millimetre of diameter matters.
  • Q9: What is the maximum string voltage? H1Z2Z2-K is rated for 1.8 kV DC system voltage, covering 1500 V PV strings.
  • Q10: How long does it last? When properly installed with correct connectors, H1Z2Z2-K is designed for a 25-year outdoor service life matching the solar module warranty.
  • Q11: Is the thin-wall build cheaper than v1? Yes — the reduced wall thickness saves material, making v2 about 5–8% lower cost per metre than v1. It is worth the premium in space-constrained installs; for standard racking, both are functionally equivalent.