ZR-YJV 4*150mm² Flame Retardant Copper Power Cable for Industrial Power Distribution

ZR-YJV 4*150mm² Flame Retardant Copper Power Cable for Industrial Power Distribution

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
ZR-YJV 4*150mm²

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
10000 meters per month

Product Summary

ZR-YJV 4*150mm² Flame Retardant Copper Power Cable for Industrial Power Distribution Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×150 mm² Four equal cores of 150 mm² copper conductor Constructio...

Product Details

Highlight:

zr-yjv 4 cores cable

,

zr-yjv 25 sq mm 4 core cable

,

copper 4 cores cable

Conductor (×4):
Bare Annealed Copper, Class 2 Stranded, Commonly 37×∅2.25 Mm (also 19×∅3.20 Mm Compact / 30×2.55 Mm), Conductor Ø ≈ 15.0–16.5 Mm Depending On Compaction
Conductor nominal area (per core):
150 Mm²
Number of cores:
4
Conductor construction:
Class 2, 37×∅2.25 Mm,IEC 60228 / GB/T 3956, Min. 15 Wires
Conductor diameter (approx.):
15.0–16.5 Mm
Insulation (×4):
XLPE
Insulation thickness:
1.4 Mm (150 Mm² Class)
Diameter over insulated core:
17.8–19.3 Mm,conductor + 2×1.4
Filler / binder:
FR PP Filler + FR Tape
Outer sheath:
Flame-retardant PVC (ZR Grade)
Sheath thickness:
2.3 Mm (GB/T 12706 Multi-core 150 Mm² Class)
Overall cable diameter:
41.0 – 48.0 Mm
Design outer diameter:
≈ 44.0 Mm
Approx. weight:
5200 – 6600 Kg/km
Design weight:
≈ 5600 Kg/km

Product Description

ZR-YJV 4*150mm² Flame Retardant Copper Power Cable for Industrial Power Distribution

Cable Designation & Meaning

Code

Meaning

ZC

Flame retardant Class C 

YJ

Cross-linked polyethylene (XLPE) insulation

V

Polyvinyl chloride (PVC) sheath 

4×150 mm²

Four equal cores of 150 mm² copper conductor


Construction: Four 150 mm² copper conductors (3 phase + 1 neutral), XLPE insulation, PVC outer sheath. No metallic screen/armour as standard (can be added on request).


ZR-YJV 4*150mm² Flame Retardant Copper Power Cable for Industrial Power Distribution


ZC-YJV 4×150 mm² — LV Flame-Retardant Four-Core Power Cable — Specification

1. Overview & Ratings. ZC-YJV 4×150 is a heavy four-wire LV main feeder cable rated 0.6/1 kV (Um 1.2), 90 °C working, ZC class C PVC sheath: four equal 150 mm² compacted copper cores (L1/L2/L3 + N), dry-cured XLPE, unarmored, 2+2 lay. OD ≈ 35 mm, ≈ 5600 kg/km (est.), ≈ 300 A per core free air at 30 °C (est.). Scope: heavy main feeders, large motor banks, transformer secondaries and plant distribution trunks — not 950°C fire duty.


2. Construction Stack (Inner → Outer, expanded).


Layer / Feature Build Function
Conductors L1/L2/L3/N 4×150 compacted Cu, Class 2, ≈37 strands R ≤0.124 Ω/km all cores
Strand compaction Concentric layers rolled compact per core Compact heavy bundle, clean lugs
XLPE insulation Dry-cured PE, ≈1.8 mm Uniform 90°C dielectric
Core identification L1/L2/L3/N color-coded insulation Correct sequence at switchboard
2+2 core laying Four equal cores in two pairs Round heavy finished bundle
PVC ZC sheath Class C, ≈1.8 mm overall Self-extinguishes, prints clear


3. Electrical Characteristics. All 150 cores R ≤ 0.124 Ω/km @20 °C. Test 3.5 kV AC / 5 min; ≈ 300 A per core (est., air 30 °C); short-circuit ≈ 16 kA / 1 s (est.); 50/60 Hz; unscreened; low-loss XLPE; high stable insulation resistance.

Insulation & Sheath Data

Property

Value

Insulation material

XLPE (cross-linked polyethylene)

Outer sheath material

PVC (ST₂)

Long-term service temp.

90 °C (continuous)

Max. conductor temp. (normal)

90 °C

Short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Test voltage AC (5 min)

3.5 kV

Dielectric strength

≥ 20 kV/mm

Volume resistivity @20 °C

≥ 1×10¹⁴ Ω·cm

Shield

None as standard (can be added)

Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

GB/T 12706.1 / IEC 60502-1

Max. system voltage

1.2 kV AC

—

Test voltage AC (5 min)

3.5 kV

Routine test

DC resistance @20 °C

≤ 0.124 Ω/km per core

GB/T 3956 Class 2 Cu max (150 mm²)

AC resistance @90 °C (est.)

≈ 0.159 Ω/km per core

—

Current rating in air (30 °C)

3-phase: 330 A​

4×150, touching, in free air

Current rating in tray (30 °C)

3-phase: 360 A​

4×150, spaced 2×OD

Current rating buried in ground (20 °C, thermal resistivity 1.2 K·m/W)

3-phase: 340 A​

direct buried

Current rating in conduit (30 °C)

3-phase: 290 A​

—

Short-circuit current (1 s, Cu, 250 °C)

≈ 16.5 kA (16,500 A) per core

—

Capacitance (core-to-sheath, approx.)

≈ 0.26 µF/km

XLPE

Inductive reactance (approx.)

≈ 0.08 Ω/km

at 50 Hz

Frequency

50/60 Hz AC

—


Reference values: 4×150 at 330 A three-phase, 400 V → max load ≈ 198 kW​ (cos φ = 0.8). Suitable for extra-large three-phase distribution with full-size neutral, heavy industrial equipment, and main building feeders.


4. Thermal & Flame. 90 °C continuous, 250 °C short-time; ZC class C self-extinguishing — flame retardancy, not 950°C integrity; survives large-unit start-stop cycling; indoor preferred, UV jacket optional.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

90 °C (continuous)

Max. short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Min. installation ambient temp.

0 °C (below 0 °C requires preheating)

Service ambient range

−20 °C to +90 °C

Flexing temp. range

0 °C to +90 °C

Fire Performance (ZC-YJV — Flame Retardant C)

Property

Value / Requirement

Flame retardant

GB/T 18380.12 / IEC 60332-1-2​ (single cable, self-extinguishing)

Flame retardant class

Class C​ (ZC) per GB/T 19666

Halogen content

Contains halogen (PVC sheath)

Smoke density

Not low-smoke (PVC)

Corrosivity

Corrosive (PVC)

Toxicity

Toxic fumes when burned (PVC)

EMI shielding

None (no metallic screen/armour)


5. Installation Practice & Handling. Hydraulic crimp 150 mm² lugs on all four cores, heavy glands to ≈35 mm OD, torque per table; bend ≥ 15×OD ≈ 525 mm; apply conduit-fill and tray-grouping derating; keep the bundle tidy; verify four-core continuity, phase sequence, neutral and insulation before energizing.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 15 × OD → ≈ 578 mm at Ø38.5 mm

four-core unarmoured

Max. pulling tension

2,250 N per core (150 mm² × 15 N/mm²)

Cu conductor limit

Direct burial

Suitable (with sand bedding)

—

Surface mounting

Heavy-duty cable tray, ladder, cleats

—

Conduit ID

≥ 80 mm

—

Fixing

heavy-duty cleats, cable ties

—

Impact resistance

Moderate

—

Water resistance

Good (PVC sheath)

—

UV resistance

Fair (PVC degrades outdoors, use UV-resistant PVC or conduit)

—

Flex life

Good (Class 2 stranded)

fixed installation

Termination note

Standard compression lugs or mechanical connectors

—


6. Typical Service Applications. Heavy main feeders, large motor banks, transformer secondaries, plant distribution trunks and large-unit supply circuits.

ZR-YJV 4*150mm² Flame Retardant Copper Power Cable for Industrial Power Distribution


7. Testing & QA Regime (16 items). Routine: DC resistance on all cores, 3.5 kV withstand, insulation resistance, continuity, insulation and sheath thickness, dimensional check, strand construction, eccentricity, color ID, print legibility, mass, jacket finish, packing inspection. Type: ZC flame test, short-circuit rating.


Cable Parameter


ZR-YJV 4×150 mm² — Flame-Retardant Four-Core Power Cable (0.6/1 kV) · Product Parameters
CU / XLPE / PVC · 4 × 150 mm² · GB/T 12706.1, IEC 60502-1, GB/T 3956, GB/T 19666 · nominal values for reference
Overall Ø  ≈ 50.9 mm Approx. weight  ≈ 6435 kg/km (Al ≈ 2669)
DC resistance  ≤ 0.124 Ω/km @ 20 °C (per core) Ampacity  ≈ 325 A (air) / 345 A (buried) @ 25 °C
No. Parameter Value Unit Notes / Standard Reference
1 · Identification
1 Product name Flame-retardant copper-conductor XLPE-insulated PVC-sheathed power cable (four-core) — ZR-YJV; halogen-containing flame-retardant
2 Model ZR-YJV 4×150 — 4 cores × 150 mm²; CU / XLPE / PVC
3 Design standards GB/T 12706.1; IEC 60502-1 — Conductor GB/T 3956; fire GB/T 19666
4 Rated voltage U0/U 0.6/1 kV Um = 1.2 kV; AC 50 Hz
5 Core arrangement 4 cores (L1/L2/L3 + N) — Three phases + neutral
6 Nominal cross-section 150 mm² Per core, GB/T 3956
2 · Conductor
1 Material Plain annealed copper — High conductivity
2 Class Class 2 (stranded) — GB/T 3956 / IEC 60228
3 Stranding (per core) 37 × 2.26 mm (37/2.26) — 1+6+12+18 concentric rings
4 Conductor diameter ≈ 15.80 mm Per core (7 × 2.26)
5 Max. DC resistance @ 20 °C 0.124 Ω/km GB/T 3956 Class 2 Cu
3 · Insulation
1 Material Cross-linked polyethylene (XLPE) — Thermally cross-linked
2 Nominal thickness 1.4 mm GB/T 12706.1 (150 mm² step)
3 Diameter over insulation ≈ 18.60 mm Per core (calculated)
4 · Assembly
1 Core lay-up Four cores around dry central filler + binder tape — Round bundle
2 Diameter over lay-up ≈ 44.9 mm Calculated
5 · Sheath
1 Material Flame-retardant PVC, ST2 — Black (or as ordered)
2 Nominal thickness 2.3 mm GB/T 12706.1 / Mingda four-core table
3 Overall diameter ≈ 50.9 mm Mingda 50.9
4 Approx. cable weight ≈ 6435 kg/km Mingda 6435 (Al ≈ 2669)
6 · Electrical
1 DC conductor resistance 0.124 Ω/km GB/T 3956 @ 20 °C, per core
2 Routine voltage test 3.5 kV / 5 min — No breakdown; 50 Hz AC
3 Insulation resistance ≥ 36.7 MΩ·km Finished cable @ 20 °C
4 XLPE volume resistivity ≥ 1 × 10¹² Ω·cm Material level
5 Capacitance (approx.) ≤ 0.45 μF/km Per core
6 Ampacity — air @ 25 °C (4 cores) ≈ 325 A Mingda; 3×150 agrees
7 Ampacity — buried @ 25 °C ≈ 345 A Mingda; soil resistivity dependent
7 · Thermal
1 Continuous conductor temperature 90 °C XLPE class
2 Short-circuit temperature (≤ 5 s) 250 °C GB/T 12706.1 / IEC 60502-1
3 Ambient service range -20 to +45 °C Per datasheet family
4 Min. laying temperature 0 °C Pre-heat below 0 °C
8 · Fire (ZR)
1 Flame-retardant class ZC by default ("ZR") — GB/T 19666; halogen-containing PVC
2 Single-cable flame test Pass — GB/T 18380.12
3 Bunched flame test — class C Char ≤ 2.5 m — GB/T 18380.35; 20 min; ≥ 1.5 L/m
4 Halogen content Halogen-containing — LSZH needs WDZ-YJY
9 · Installation
1 Min. bending radius (multi-core) ≥ 15 × OD — GB 50168 practice
2 Laying methods Conduit, tray, trench, duct, trunking — Mechanical protection where buried
3 Site test after installation DC 4U0 = 2.4 kV / 15 min — Q/GDW 13244.1-2018
10 · Packing
1 Standard delivery length 100 m per coil/drum — Custom lengths available
2 Marking Model, voltage, maker, year, length marks — GB/T 6995 / project spec


Cable Test Parameter


ZR-YJV 4×150 mm² — Test / Verification Parameters (per GB/T 12706.1 & IEC 60502-1)
Stage Test Item Method / Standard Acceptance Criterion Notes
Routine Conductor DC resistance GB/T 3956 (IEC 60228) ≤ 0.124 Ω/km @ 20 °C (per core) Every production length
Routine Power-frequency withstand voltage GB/T 12706.1 / IEC 60502-1 3.5 kV AC / 5 min, no breakdown Conductor-to-earth/water
Routine Construction check GB/T 2951 Ins. ≥ 1.4 mm; sheath ≥ 2.3 mm; OD within tolerance Thickness & diameter
Sample Hot set test — XLPE GB/T 12706.1 §16.3.13 / GB/T 2951.11 200 ± 3 °C, 15 min, 0.2 MPa: load elongation ≤ 175 %; permanent ≤ 15 % Cross-linking degree
Sample Conductor construction & diameter GB/T 3956 Class 2; 37 × 2.26 mm; Ø ≈ 15.80 mm Per batch
Type Single-cable flame test GB/T 18380.12 No flame spread to top reference ZR property
Type Bunched flame test — class C GB/T 18380.35 Char ≤ 2.5 m; 20 min; ≥ 1.5 L/m ZC class
Type Bending test GB/T 12706.1 No damage on specified mandrel Multi-core rule
Post-install DC withstand test Q/GDW 13244.1-2018 2.4 kV DC / 15 min, no breakdown New installations
Optional Insulation resistance @ 20 °C Factory method ≥ 36.7 MΩ·km Not routine in GB/T 12706.1
Optional XLPE volume resistivity Material test ≥ 1 × 10¹² Ω·cm Material reference


Cable Cross Section Structure

ZR-YJV 4*150mm² Flame Retardant Copper Power Cable for Industrial Power Distribution

ZR-YJV 4×150 mm² — Cable Cross-Section Structure (Schematic)
Four-core construction from conductor to outer sheath · nominal values per GB/T 12706.1 / IEC 60502-1 · not to exact scale
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor (Cu) × 4 Annealed copper, Class 2 stranded — 37 × 2.26 mm per core (37/2.26, 1+6+12+18), nominal 150 mm² per core — ≈ 15.80 (Ø per core) Current-carrying element; max DC resistance ≤ 0.124 Ω/km @ 20 °C (per core)
2 Insulation (XLPE) × 4 Cross-linked polyethylene 1.4 ≈ 18.60 (Ø per core, over insulation) Dielectric barrier; rated 90 °C continuous; withstands 3.5 kV / 5 min
3 Core lay-up Four insulated cores laid up around central non-hygroscopic filler; binder tape — ≈ 44.9 (Ø over lay-up, calc.) Forms a round assembly for sheathing
4 Outer sheath (PVC) Flame-retardant PVC, ST2 type, black 2.3 ≈ 50.9 (Ø overall) Mechanical & moisture protection; flame retardance ZC (ZR) per GB/T 19666
Key Dimensions & Properties
Overall diameter ≈ 50.9 mm Mingda four-core unarmored table

Approx. cable weight ≈ 6435 kg/km Mingda 6435 (Al ≈ 2669)

Rated voltage 0.6/1 kV AC 50 Hz; max system voltage Um = 1.2 kV

Max conductor temperature 90 / 250 °C Continuous / short-circuit (≤ 5 s)

Min. bending radius (multi-core) ≥ 15 × OD — OD = actual cable diameter

Flame-retardant class ZC (ZR) — GB/T 19666

Schematic — not to exact scale. Nominal values for reference; confirm against factory test certificate.


Product Structure Introduction


Product Structure Introduction — ZR-YJV 4×150 mm² 
Four-core layered construction description, from conductor to outer sheath · per GB/T 12706.1 & IEC 60502-1 · CU / XLPE / PVC · 0.6/1 kV
1. Cable General Description
ZR-YJV 4×150 is a halogen-containing flame-retarding four-core cable, rated 0.6/1 kV, with four 150 mm² copper conductors, XLPE dielectric and an ST2 PVC outer cover. It is designed and type-tested per GB/T 12706.1 / IEC 60502-1, uses GB/T 3956 conductor grading and carries a ZC flame class under GB/T 19666. It measures ≈ 50.9 mm over the sheath, weighs ≈ 6435 kg/km, and 100 m coils or drums are customary.
The four loaded cores pass roughly 325 A in air at 25 °C, which suits heavy risers, plant switchboards and motor sub-feeds.
2. Conductor Design & Build
A 150 mm² core consists of thirty-seven 2.26 mm annealed copper wires (37/2.26), arranged in the 1+6+12+18 concentric pattern of Class 2 and compacted to ≈ 15.80 mm. The DC resistance limit is 0.124 Ω/km at 20 °C; the four-ring pack provides a firm, round core for crimping and glanding.
3. Insulation Design & Build
XLPE is extruded at 1.4 mm — the 150 mm² wall step of GB/T 12706.1 — making each core ≈ 18.60 mm over insulation. The compound is rated for 90 °C continuous duty and 250 °C for five seconds in fault; it keeps volume resistivity at or above 1×10¹² Ω·cm and passes the 3.5 kV AC five-minute routine proof.
4. Assembly, Filling & Jacketing
The four cores are stranded around a dry, non-hygroscopic central filler, secured by binder tape to about 44.9 mm, and jacketed with 2.3 mm of flame-retarded ST2 PVC to close at 50.9 mm. ZC fire behaviour follows from GB/T 18380.12 and GB/T 18380.35; halogen-bearing PVC means LSZH duty should specify WDZ-YJY.
5. Site, Storage & Maintenance Notes
• Do not bend inside 15 × OD.  • Carry out the DC 4U0 = 2.4 kV / 15 min site test before switching on.  • Service band −20 to +45 °C; warm drums for pulls under 0 °C.  • Adjust the 325 A / 345 A reference for ambient, grouping and burial conditions.  • Use lugs and glands sized for the 15.80 mm core and 50.9 mm jacket.


8. Factory Advantages.

  • Equal-size four-core build — full 150 neutral handles unbalance and harmonic return without extra selection.
  • Stable XLPE cure — even cross-linking keeps the 90°C dielectric consistent on long main feeders.
  • Dosed ZC compound — self-extinguishing jacket protects switchrooms and plant rooms.
  • Length-on-demand — cut to exact main feeder meter with sealed ends.
  • Uniform resistance log — all four cores' R recorded to lot for balanced performance.
  • Continuous print line — type, size, ZC, voltage and length readable along the run.
  • Phase-color option — L1/L2/L3/N colors reduce wiring errors at switchboards.
  • Heavy drum pack — heavy section on a rated wooden drum, moisture-sealed ends.
  • Certified QA pack — routine + type test record shipped per batch for commissioning.


ZR-YJV 4*150mm² Flame Retardant Copper Power Cable for Industrial Power Distribution


9. Packaging, Storage & Logistics. Cut to measured main feeder length on a heavy wooden drum with sealed ends; continuous marking; store dry indoor on drum supports, shaded, avoid direct UV.


ZR-YJV 4*150mm² Flame Retardant Copper Power Cable for Industrial Power Distribution


10. Procurement Specification. State "ZC-YJV 4×150", length, class C, core colors; note full-size neutral suits harmonics and unbalance; request the uniform resistance log and 16-item QA record. Est. values confirmed against the factory certificate; not fire-rated.


11. Cable Industry FAQ.

  • Q1: How does 4×150 differ from 4×70? Heavier section: cores 150 vs 70 mm²; OD 35 vs 26 mm, mass 5600 vs 3300 kg/km, core current 300 vs 175 A, R 0.124 vs 0.268 Ω/km; built for main feeders and motor banks rather than mid-heavy branch circuits.
  • Q2: Why a full-size neutral here? A 150 neutral matches the phases to absorb large-unit unbalance and VFD/rectifier harmonics on a four-wire feeder.
  • Q3: Is ZC fire-resistant? No. Class C self-extinguishes; it does not hold live at 950°C/180min.
  • Q4: Core DC resistance? ≤0.124 Ω/km at 20°C on every 150 core.
  • Q5: Screen or armor? Unscreened standard; add braid near VFD EMI; steel-tape armor for buried ground-crushing duty.
  • Q6: Current per core? ≈300 A (est.) free air 30°C; derate in crowded ducts and trays.
  • Q7: Bending? ≈525 mm (15×OD); use bending tools and sheaves.
  • Q8: Connectors? 150 mm² lugs on all four cores; gland to ≈35 mm OD.
  • Q9: Indoor or outdoor? Indoor preferred; specify UV-stabilized jacket for exposed runs.
  • Q10: Packing? Heavy wooden drum with moisture-sealed ends.
  • Q11: What proof ships? Uniform resistance log + 16-test record; est. values confirmed against certificate.