"and other insulations flexible copper wire conductor"
Please try a different search term or browse our product categories.
Kabel fotowoltaiczny TUV 1kV H1Z2Z2-K 4mm2 Pv
1500V DC Solar Wire H1Z2Z2-K 4.0mm² TUV XLPE Photovoltaic Cable Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) Z Halogen-free ...
Kabel zasilający YJV22 średniego napięcia 3x150mm2 Miedziany kabel opancerzony MV 15kV
YJV22 3x150mm² Copper XLPE Armored MV Cable 8.7/15kV Reliable Underground Power Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath 22 Steel tape armoured (double steel tape) 3×150 mm² Three cores, each 150 mm² copper Construction: Copper ...
Kabel Aluminiowy YJLV22 XLPE 3x70mm² 8.7/15kV Zbrojony Kabel Zasilający SN
Aluminum XLPE Cable YJLV22 3x70mm² 8.7/15kV Armored MV Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...
Aluminiowy przewodnik XLPE Kabel 3 rdzeń 25mm2 YJLV22 8,7/10kV Pancerny
Aluminum Conductor XLPE Cable 3 Core 25mm² YJLV22 8.7/10kV Armored Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...
Ciężki kabel MV YJV22 3x150mm2 8,7/15kV Cable XLPE
Heavy Gauge MV Cable YJV22 3x150mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...
Mega Industrial Main Cable YJV22 3x120mm2 8,7/15kV Pancerny MV XLPE
Mega Industrial Main Cable YJV22 3x120mm² 8.7/15kV Armored MV XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV; U...
Podstawowy kabel dystrybucyjny 3 rdzenia 70mm2 YJV22 8,7/10kV Pancerny XLPE
Primary Distribution Cable 3 Core 70mm² YJV22 8.7/10kV Armored XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV; ...
4x185mm2+1x150mm2 Kabel ognioodporny 0.6KV 1KV Kabel miedziany izolowany minerałem
Super Fire Cable BTTRZ 4x185mm²+1x150mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...