"and other insulations flexible copper wire conductor"
Please try a different search term or browse our product categories.
Green Copper Control Wire BV 2.5mm2 PVC Insulated Electrical Building Cable
Green BV 2.5mm² PVC Insulated Copper Control Wire Electrical Building Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain copper conductor (solid or ...
PV1-F 6.0mm² TUV 1500V DC Solar Cable UV Resistant Weatherproof PV Wire
PV1-F 6.0mm² TUV 1500V DC Solar Cable UV Resistant Weatherproof PV Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor, ...
3x300mm2 Medium Voltage Power Cable Al XLPE Super Heavy Aluminum Cable
Super Heavy Aluminum Cable YJLV22 3x300mm² 8.7/10kV 8.7/15kV Armored XLPE MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7...
Transport Hub Main Power Cable YJV22 3x240mm² 8.7/15kV Armored MV XLPE
Transport Hub Main Power Cable YJV22 3x240mm² 8.7/15kV Armored MV XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...
Mega Industrial Main Cable YJV22 3x120mm² 8.7/15kV Armored MV XLPE
Mega Industrial Main Cable YJV22 3x120mm² 8.7/15kV Armored MV XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV; U...
4x185mm2+1x150mm2 Fire Resistant Cable 0.6KV 1KV Mineral Insulated Copper Cable
Super Fire Cable BTTRZ 4x185mm²+1x150mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...
4+1 Core Fire Resistant Cable 120mm2+1x95mm2 BTTRZ Fire Substation Cable
Fire Substation Cable 4+1 Core 120mm²+1x95mm² BTTRZ Fire Resistant Mineral Insulated Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6...
Large Fire Rated Wire 4x95mm2+1x70mm2 Mineral Insulated Heating Cable
Large Fire Cable BTTRZ 4x95mm²+1x70mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV ...